Objective: To investigate the effectiveness of the plate screw internal fixation technique on the clinical outcomes of patients with traumatic fractures of long bones in the lower extremities. Methods: From January 20...Objective: To investigate the effectiveness of the plate screw internal fixation technique on the clinical outcomes of patients with traumatic fractures of long bones in the lower extremities. Methods: From January 2022 to December 2023, 70 patients with traumatic fractures of long bones in the lower extremities were admitted to the hospital and randomly divided into two groups: the control group and the observation group, each consisting of 35 cases. The control group underwent traditional closed interlocking intramedullary nailing, while the observation group received internal fixation with steel plates and screws. Relevant surgical indicators, treatment effectiveness, and postoperative complication rates were compared between the two groups. Results: The observation group exhibited significantly short surgical duration (80.65 ± 5.01 vs. 88.36 ± 5.26 minutes), fracture healing time (13.27 ± 0.32 vs. 15.52 ± 0.48 weeks), and hospitalization days (10.49 ± 1.13 vs. 16.57 ± 1.15 days) compared to the control group (P = 0.000). The effective treatment rate was significantly higher in the observation group (29/82.86%) than in the control group (21/60.00%), with a significant difference observed (χ2 = 4.480, P = 0.034). Additionally, the complication rate in the observation group (2/5.71%) was significantly lower than that in the control group (8/22.86%), with a correlated difference (χ2 = 4.200, P = 0.040). Conclusion: The plate screw internal fixation technique demonstrates significant clinical efficacy in treating traumatic fractures of long bones in the lower extremities. It improves the healing rate, reduces complications, and represents a safe and effective treatment strategy worthy of widespread use and application.展开更多
Objective:To compare the efficacy of open reduction and volar locking plate internal fixation with closed reduction and external fixation in the treatment of distal radius fractures by using meta analysis.Methods:The ...Objective:To compare the efficacy of open reduction and volar locking plate internal fixation with closed reduction and external fixation in the treatment of distal radius fractures by using meta analysis.Methods:The databases of CNKI,Wanfang,Weipu,Chinese biomedical literature,Pubmed,Embase,and Cochrane Library were retrieved,and the randomized controlled studies that directly compared the efficacy of plate internal fixation and closed reduction external fixation in the treatment of distal radius fractures published publicly from the establishment of the database to April 2023 were collected.The two researchers independently screened the retrieved literature according to the inclusion and exclusion criteria,extracted data,used Cochrane risk bias assessment tool for quality assessment,and used RevMan 5.4 software for meta analysis.Results:A total of 10 randomized controlled trials were included,all of which were in English.There were 1042 patients in total,and 9 of them were rated as low risk.Meta analysis results showed that one year after the treatment of distal radius fracture with volar locking plate internal fixation,DASH score[MD=-5.64,95%CI(-7.21,-4.06),P<0.00001];One year later,PRWE score[MD=-5.90,95%CI(-8.88,-2.92),P=0.001];Palm flexion[MD=5.92,95%CI(1.29,10.55),P=0.01];Pronation[MD=2.48,95%CI(0.59,4.36),P=0.01];Postrotation[MD=4.73,95%CI(2.15,7.31),P=0.0003];Grip strength[MD=0.61,95%CI(0.12,1.10),P=0.02];palmar tilt angle[MD=9.84,95%CI(5.66,14.02),P<0.00001];Radial inclination[MD=4.33,95%CI(2.97,5.69),P<0.00001]was superior to closed reduction plaster or splint external fixation.One year later,the European Five dimensional Health Scale(EQ-5D-5L)score[MD=0.02,95%CI(-0.01,0.05),P=0.27];Back extension[MD=2.22,95%CI(-4.15,8.59),P=0.49];Ulnar deviation[MD=3.49,95%CI(-0.80,7.78),P=0.11];Radial deviation[MD=2.05,95%CI(-2.39,6.50),P=0.37];Ulnar variance[MD=-1.14,95%CI(-3.16,0.88),P=0.27];There was no significant difference in complications[MD=0.77,95%CI(0.54,1.10),P=0.16](P>0.05).Conclusion:Based on the current clinical data,internal fixation with volar locking plate is more conducive to mid-term DASH score and grip strength recovery than closed reduction plaster or splint external fixation,but there is no significant difference in the quality of life and complications of patients.For adult distal radius fractures,surgical indications should be carefully grasped,and non operative treatment should be given priority.展开更多
Objective:To analyze the effect of locking compression plate on the success rate of operation and the time of postoperative recovery.Methods:120 patients with limb fractures from March 2018 to March 2020 were randomly...Objective:To analyze the effect of locking compression plate on the success rate of operation and the time of postoperative recovery.Methods:120 patients with limb fractures from March 2018 to March 2020 were randomly divided into control group(60 cases)and observation group(60 cases).The control group was treated with plate screw internal fixation,The observation group used locking compression plate internal fixation,Compare the effect of treatment,the success rate of operation and the time of postoperative recovery.results:compared the effective rate of the two groups,the observation group(93.33%)was significantly higher than the control group(75.00%).Compared with the two groups,the success rate of operation and the time of postoperative recovery,the observed composition power was higher than that of the control group,and the postoperative recovery time was lower than that of the control group,P<0.05.Conclusion:The use of locking compression plate for the treatment of limb fracture can significantly increase the probability of successful operation,shorten the recovery time after operation,the overall curative effect is ideal,and the clinical popularization value is high.展开更多
文摘Objective: To investigate the effectiveness of the plate screw internal fixation technique on the clinical outcomes of patients with traumatic fractures of long bones in the lower extremities. Methods: From January 2022 to December 2023, 70 patients with traumatic fractures of long bones in the lower extremities were admitted to the hospital and randomly divided into two groups: the control group and the observation group, each consisting of 35 cases. The control group underwent traditional closed interlocking intramedullary nailing, while the observation group received internal fixation with steel plates and screws. Relevant surgical indicators, treatment effectiveness, and postoperative complication rates were compared between the two groups. Results: The observation group exhibited significantly short surgical duration (80.65 ± 5.01 vs. 88.36 ± 5.26 minutes), fracture healing time (13.27 ± 0.32 vs. 15.52 ± 0.48 weeks), and hospitalization days (10.49 ± 1.13 vs. 16.57 ± 1.15 days) compared to the control group (P = 0.000). The effective treatment rate was significantly higher in the observation group (29/82.86%) than in the control group (21/60.00%), with a significant difference observed (χ2 = 4.480, P = 0.034). Additionally, the complication rate in the observation group (2/5.71%) was significantly lower than that in the control group (8/22.86%), with a correlated difference (χ2 = 4.200, P = 0.040). Conclusion: The plate screw internal fixation technique demonstrates significant clinical efficacy in treating traumatic fractures of long bones in the lower extremities. It improves the healing rate, reduces complications, and represents a safe and effective treatment strategy worthy of widespread use and application.
基金2022 Key Specialty Construction Project of Traditional Chinese Medicine:Traditional Chinese Orthopedics and Traumatology Department (No.962042)2020 Regional Traditional Chinese Medicine (Orthopedics and Traumatology)Diagnosis and Treatment Center (Jin Wei Zhong[2020]No.5)。
文摘Objective:To compare the efficacy of open reduction and volar locking plate internal fixation with closed reduction and external fixation in the treatment of distal radius fractures by using meta analysis.Methods:The databases of CNKI,Wanfang,Weipu,Chinese biomedical literature,Pubmed,Embase,and Cochrane Library were retrieved,and the randomized controlled studies that directly compared the efficacy of plate internal fixation and closed reduction external fixation in the treatment of distal radius fractures published publicly from the establishment of the database to April 2023 were collected.The two researchers independently screened the retrieved literature according to the inclusion and exclusion criteria,extracted data,used Cochrane risk bias assessment tool for quality assessment,and used RevMan 5.4 software for meta analysis.Results:A total of 10 randomized controlled trials were included,all of which were in English.There were 1042 patients in total,and 9 of them were rated as low risk.Meta analysis results showed that one year after the treatment of distal radius fracture with volar locking plate internal fixation,DASH score[MD=-5.64,95%CI(-7.21,-4.06),P<0.00001];One year later,PRWE score[MD=-5.90,95%CI(-8.88,-2.92),P=0.001];Palm flexion[MD=5.92,95%CI(1.29,10.55),P=0.01];Pronation[MD=2.48,95%CI(0.59,4.36),P=0.01];Postrotation[MD=4.73,95%CI(2.15,7.31),P=0.0003];Grip strength[MD=0.61,95%CI(0.12,1.10),P=0.02];palmar tilt angle[MD=9.84,95%CI(5.66,14.02),P<0.00001];Radial inclination[MD=4.33,95%CI(2.97,5.69),P<0.00001]was superior to closed reduction plaster or splint external fixation.One year later,the European Five dimensional Health Scale(EQ-5D-5L)score[MD=0.02,95%CI(-0.01,0.05),P=0.27];Back extension[MD=2.22,95%CI(-4.15,8.59),P=0.49];Ulnar deviation[MD=3.49,95%CI(-0.80,7.78),P=0.11];Radial deviation[MD=2.05,95%CI(-2.39,6.50),P=0.37];Ulnar variance[MD=-1.14,95%CI(-3.16,0.88),P=0.27];There was no significant difference in complications[MD=0.77,95%CI(0.54,1.10),P=0.16](P>0.05).Conclusion:Based on the current clinical data,internal fixation with volar locking plate is more conducive to mid-term DASH score and grip strength recovery than closed reduction plaster or splint external fixation,but there is no significant difference in the quality of life and complications of patients.For adult distal radius fractures,surgical indications should be carefully grasped,and non operative treatment should be given priority.
文摘Objective:To analyze the effect of locking compression plate on the success rate of operation and the time of postoperative recovery.Methods:120 patients with limb fractures from March 2018 to March 2020 were randomly divided into control group(60 cases)and observation group(60 cases).The control group was treated with plate screw internal fixation,The observation group used locking compression plate internal fixation,Compare the effect of treatment,the success rate of operation and the time of postoperative recovery.results:compared the effective rate of the two groups,the observation group(93.33%)was significantly higher than the control group(75.00%).Compared with the two groups,the success rate of operation and the time of postoperative recovery,the observed composition power was higher than that of the control group,and the postoperative recovery time was lower than that of the control group,P<0.05.Conclusion:The use of locking compression plate for the treatment of limb fracture can significantly increase the probability of successful operation,shorten the recovery time after operation,the overall curative effect is ideal,and the clinical popularization value is high.