An effective method was proposed to establish the continuous cooling transformation(CCT) diagrams of aluminum alloys using in situ voltage measurement.The voltage change of samples with predefined dimension was reco...An effective method was proposed to establish the continuous cooling transformation(CCT) diagrams of aluminum alloys using in situ voltage measurement.The voltage change of samples with predefined dimension was recorded under the constant current state during continuous cooling.Solutionizing time,together with starting and finishing temperatures of phase transformation of the alloy can be obtained from relationships of voltage vs time and temperature.A critical cooling rate without detectable phase transition during continuous cooling can be determined.Continuous cooling transformation diagrams of tested samples can be established conveniently based on these results.Microstructure observation and differential scanning calorimetry(DSC) testing were applied to verify the reliability of continuous cooling transformation diagram.展开更多
The current voltage (IV) characteristics are greatly influenced by the dispersion effects in A1GaN/CaN high electron mobility transistors. The direct current (DC) IV and pulsed IV measurements are performed to giv...The current voltage (IV) characteristics are greatly influenced by the dispersion effects in A1GaN/CaN high electron mobility transistors. The direct current (DC) IV and pulsed IV measurements are performed to give a deep investigation into the dispersion effects, which are mainly related to the trap and self-heating mechanisms. The results show that traps play an important role in the kink effects, and high stress can introduce more traps and defects in the device. With the help of the pulsed IV measurements, the trapping effects and self-heating effects can be separated. The impact of time constants on the dispersion effects is also discussed. In order to achieve an accurate static DC IV measurement, the steady state of the bias points must be considered carefully to avoid the dispersion effects.展开更多
A fast automatic AC-DC switch is designed and fabricated mainly by a microcontroller and three double poles single throw reed relays.This new switch is introduced to establish a fully automated system for AC-DC measur...A fast automatic AC-DC switch is designed and fabricated mainly by a microcontroller and three double poles single throw reed relays.This new switch is introduced to establish a fully automated system for AC-DC measurements through ACDC transfer standards for the first time at the National Institute for standards(N IS)in Egypt.The implemented circuit of theautomatic AC-DC switch and its protection are presented in details.An AC voltage source is calibrated against DC voltagesource by using the demonstrated automatic switch as an application The calibrated voltage ranges are2V,6V,20V and60V as examples.The uncertainty budget is also evaluated for the calibrated values.展开更多
An automated multi-range multipliers(range resistors)system is established for the AC voltage measurements by using a thermal voltage converter.It is performed automatically by selecting the appropriate multiplier w...An automated multi-range multipliers(range resistors)system is established for the AC voltage measurements by using a thermal voltage converter.It is performed automatically by selecting the appropriate multiplier whose voltage range contains the voltage to be measured without changing it manually through a new designed system.It consists of control part through a micro-controller controlled by specified prepared Lab-VIEW program and switching part through electronic relays in one circuit as clearly described in this work.It is used for measuring the ac voltage in the range from 1 V to 200 V.Also,it can be used for the voltage ranges up to 1 000 V by putting some factors into consideration.The AC-DC transfer differences for these multipliers combined with thermal voltage converter are determined automatically against another standard thermal voltage converter by using another Lab-VIEW program.展开更多
We investigate the effects of (N,N’-diphenyl)-N,N’-bis(1-naphthyl)-1,1’-biphenyl-4,4’-diamine (NPB) buffer layers on charge collection in inverted ZnO/MEH-PPV hybrid devices. The insertion of a 3-nm NPB thin...We investigate the effects of (N,N’-diphenyl)-N,N’-bis(1-naphthyl)-1,1’-biphenyl-4,4’-diamine (NPB) buffer layers on charge collection in inverted ZnO/MEH-PPV hybrid devices. The insertion of a 3-nm NPB thin layer enhances the efficiency of charge collection by improving charge transport and reducing the interface energy barrier, resulting in better device performances. S-shaped light J–V curve appears when the thickness of the NPB layer reaches 25 nm, which is induced by the inefficient charge extraction from MEH-PPV to Ag. Capacitance–voltage measurements are performed to further investigate the influence of the NPB layer on charge collection from both simulations and experiments.展开更多
We measure the half-wave voltage of LiNbO3 phase modulators in a 26-GHz wideband frequency range, and then analyze it by the phase modulation photonic peak gain linked to the interferometric demodu- lation. The optica...We measure the half-wave voltage of LiNbO3 phase modulators in a 26-GHz wideband frequency range, and then analyze it by the phase modulation photonic peak gain linked to the interferometric demodu- lation. The optical interferometer is constructed with two 50:50 couplers and two fiber arms with a l-m difference in fiber length. The photonic link gain peaks are frequency dependent, as indicated by the differential time delay in the interferometer. The procedure described is a new and practical half-wave voltage measurement method that can accurately predict the nonlinear frequency characteristics of the phase modulator. Moreover, the method can be applied to various types of LiNbO3 phase modulators.展开更多
The growing integration of distributed energy resources(DERs)in distribution grids raises various reliability issues due to DER's uncertain and complex behaviors.With large-scale DER penetration in distribution gr...The growing integration of distributed energy resources(DERs)in distribution grids raises various reliability issues due to DER's uncertain and complex behaviors.With large-scale DER penetration in distribution grids,traditional outage detection methods,which rely on customers report and smart meters'“last gasp”signals,will have poor performance,because renewable generators and storage and the mesh structure in urban distribution grids can continue supplying power after line outages.To address these challenges,we propose a datadriven outage monitoring approach based on the stochastic time series analysis with a theoretical guarantee.Specifically,we prove via power flow analysis that dependency of time-series voltage measurements exhibits significant statistical changes after line outages.This makes the theory on optimal change-point detection suitable to identify line outages.However,existing change point detection methods require post-outage voltage distribution,which are unknown in distribution systems.Therefore,we design a maximum likelihood estimator to directly learn distribution parameters from voltage data.We prove the estimated parameters-based detection also achieves optimal performance,making it extremely useful for fast distribution grid outage identifications.Furthermore,since smart meters have been widely installed in distribution grids and advanced infrastructure(e.g,PMU)has not widely been available,our approach only requires voltage magnitude for quick outage identification.Simulation results show highly accurate outage identification in eight distribution grids with 17 configurations with and without DERs using smart meter data.展开更多
文摘An effective method was proposed to establish the continuous cooling transformation(CCT) diagrams of aluminum alloys using in situ voltage measurement.The voltage change of samples with predefined dimension was recorded under the constant current state during continuous cooling.Solutionizing time,together with starting and finishing temperatures of phase transformation of the alloy can be obtained from relationships of voltage vs time and temperature.A critical cooling rate without detectable phase transition during continuous cooling can be determined.Continuous cooling transformation diagrams of tested samples can be established conveniently based on these results.Microstructure observation and differential scanning calorimetry(DSC) testing were applied to verify the reliability of continuous cooling transformation diagram.
基金Project supported by the National Basic Research Program of China (Grant No.2010CB327503)the National Natural Science Foundation of China (Grant No.60890191)
文摘The current voltage (IV) characteristics are greatly influenced by the dispersion effects in A1GaN/CaN high electron mobility transistors. The direct current (DC) IV and pulsed IV measurements are performed to give a deep investigation into the dispersion effects, which are mainly related to the trap and self-heating mechanisms. The results show that traps play an important role in the kink effects, and high stress can introduce more traps and defects in the device. With the help of the pulsed IV measurements, the trapping effects and self-heating effects can be separated. The impact of time constants on the dispersion effects is also discussed. In order to achieve an accurate static DC IV measurement, the steady state of the bias points must be considered carefully to avoid the dispersion effects.
文摘A fast automatic AC-DC switch is designed and fabricated mainly by a microcontroller and three double poles single throw reed relays.This new switch is introduced to establish a fully automated system for AC-DC measurements through ACDC transfer standards for the first time at the National Institute for standards(N IS)in Egypt.The implemented circuit of theautomatic AC-DC switch and its protection are presented in details.An AC voltage source is calibrated against DC voltagesource by using the demonstrated automatic switch as an application The calibrated voltage ranges are2V,6V,20V and60V as examples.The uncertainty budget is also evaluated for the calibrated values.
文摘An automated multi-range multipliers(range resistors)system is established for the AC voltage measurements by using a thermal voltage converter.It is performed automatically by selecting the appropriate multiplier whose voltage range contains the voltage to be measured without changing it manually through a new designed system.It consists of control part through a micro-controller controlled by specified prepared Lab-VIEW program and switching part through electronic relays in one circuit as clearly described in this work.It is used for measuring the ac voltage in the range from 1 V to 200 V.Also,it can be used for the voltage ranges up to 1 000 V by putting some factors into consideration.The AC-DC transfer differences for these multipliers combined with thermal voltage converter are determined automatically against another standard thermal voltage converter by using another Lab-VIEW program.
基金Project supported by the National Basic Research Program of China(Grant No.2010CB327704)the National Natural Science Foundation of China(Grant No.51272022)+2 种基金the Program for New Century Excellent Talents in University of Ministry of Education of China(Grant No.NCET-10-0220)the Research Fund for the Doctoral Program of Higher Education,China(Grant No.20120009130005)the Fundamental Research Funds for the Central Universities,China(Grant No.2012JBZ001)
文摘We investigate the effects of (N,N’-diphenyl)-N,N’-bis(1-naphthyl)-1,1’-biphenyl-4,4’-diamine (NPB) buffer layers on charge collection in inverted ZnO/MEH-PPV hybrid devices. The insertion of a 3-nm NPB thin layer enhances the efficiency of charge collection by improving charge transport and reducing the interface energy barrier, resulting in better device performances. S-shaped light J–V curve appears when the thickness of the NPB layer reaches 25 nm, which is induced by the inefficient charge extraction from MEH-PPV to Ag. Capacitance–voltage measurements are performed to further investigate the influence of the NPB layer on charge collection from both simulations and experiments.
基金supported by the Chinese Defense Advance Research Program of Science and Technology,China under Grant No.6906005003
文摘We measure the half-wave voltage of LiNbO3 phase modulators in a 26-GHz wideband frequency range, and then analyze it by the phase modulation photonic peak gain linked to the interferometric demodu- lation. The optical interferometer is constructed with two 50:50 couplers and two fiber arms with a l-m difference in fiber length. The photonic link gain peaks are frequency dependent, as indicated by the differential time delay in the interferometer. The procedure described is a new and practical half-wave voltage measurement method that can accurately predict the nonlinear frequency characteristics of the phase modulator. Moreover, the method can be applied to various types of LiNbO3 phase modulators.
文摘The growing integration of distributed energy resources(DERs)in distribution grids raises various reliability issues due to DER's uncertain and complex behaviors.With large-scale DER penetration in distribution grids,traditional outage detection methods,which rely on customers report and smart meters'“last gasp”signals,will have poor performance,because renewable generators and storage and the mesh structure in urban distribution grids can continue supplying power after line outages.To address these challenges,we propose a datadriven outage monitoring approach based on the stochastic time series analysis with a theoretical guarantee.Specifically,we prove via power flow analysis that dependency of time-series voltage measurements exhibits significant statistical changes after line outages.This makes the theory on optimal change-point detection suitable to identify line outages.However,existing change point detection methods require post-outage voltage distribution,which are unknown in distribution systems.Therefore,we design a maximum likelihood estimator to directly learn distribution parameters from voltage data.We prove the estimated parameters-based detection also achieves optimal performance,making it extremely useful for fast distribution grid outage identifications.Furthermore,since smart meters have been widely installed in distribution grids and advanced infrastructure(e.g,PMU)has not widely been available,our approach only requires voltage magnitude for quick outage identification.Simulation results show highly accurate outage identification in eight distribution grids with 17 configurations with and without DERs using smart meter data.