Improved voltage tracking of autonomous microgrid technology using a combined resonant controller with lead-lag compensator adopting negative imaginary theorem 被引量:4
1
作者 Md.Yah-Ya Ul Haque Md.Rashidul Islam +1 位作者 Tanvir Ahmed Md.Rafiqul Islam Sheikh 《Protection and Control of Modern Power Systems》 2022年第1期149-164,共16页
Growing application of distributed generation units at remote places has led to the evolution of microgrid(MG)technology.When an MG system functions independently,i.e.,in autonomous mode,unpredictable loads and uncert... Growing application of distributed generation units at remote places has led to the evolution of microgrid(MG)technology.When an MG system functions independently,i.e.,in autonomous mode,unpredictable loads and uncertainties emerge throughout the system.To obtain stable and flexible operation of an autonomous MG,a rigid control mechanism is needed.In this paper,a robust high-performance controller is introduced to improve the performance of voltage tracking of an MG system and to eliminate stability problems.A combination of a resonant controller and a lead-lag compensator in a positive position feedback path is designed,one which obeys the negative imaginary(NI)theorem,for both single-phase and three-phase autonomous MG systems.The controller has excellent tracking performance.This is investigated through considering various uncertainties with different load dynamics.The feasibility and effectiveness of the controller are also determined with a comparative analysis with some well-known controllers,such as linear quadratic regulator,model predictive and NI approached resonant controllers.This confirms the superi-ority of the designed controller. 展开更多
关键词 Negative imaginary theorem Resonant controller Lead-lag compensator Autonomous microgrid voltage tracking
原文传递
Non-linear performance analysis and voltage control of MFC based on feedforward fuzzy logic PID strategy 被引量:8
2
作者 LUO Qing-zhu AN Ai-min +1 位作者 ZHANG Hao-chen MENG Fan-cheng 《Journal of Central South University》 SCIE EI CAS CSCD 2019年第12期3359-3371,共13页
Microbial fuel cell(MFC)is a kind of promising clean power supply energy equipment,but serious nonlinearities and disturbances exist when the MFC runs,and it is an important topic to guarantee that the output voltage ... Microbial fuel cell(MFC)is a kind of promising clean power supply energy equipment,but serious nonlinearities and disturbances exist when the MFC runs,and it is an important topic to guarantee that the output voltage reaches the setting value quickly and smoothly.Regulating the feeding flow is an effective way to achieve this goal,and especially,the satisfactory results can be achieved by regulating anode feeding flow.In this work,a feedforward fuzzy logic PID algorithm is proposed.The fuzzy logic system is introduced to deal with the non-linear dynamics of MFC,and corresponding PID parameters are calculated according to defuzzification.The magnitude value of the current density is used to simulate the value of the external load.The simulation results indicate that the MFC output voltage can track the setting value quickly and smoothly with the proposed feedforward fuzzy logic PID algorithm.The proposed algorithm is more efficient and robust with respect to anti-disturbance performance and tracking accuracy than other three control methods. 展开更多
关键词 microbial fuel cell feedforward fuzzy logic PID nonlinear performance analysis output voltage tracking
下载PDF
Proton exchange membrane fuel cell voltage-tracking using artificial neural networks 被引量:1
3
作者 Seyed Mehdi RAKHTALA Reza GHADERI Abolzal RANJBAR NOEI 《Journal of Zhejiang University-Science C(Computers and Electronics)》 SCIE EI 2011年第4期338-344,共7页
Transients in load and consequently in stack current have a significant impact on the performance and durability of fuel cells.The delays in auxiliary equipments in fuel cell systems (such as pumps and heaters) and ba... Transients in load and consequently in stack current have a significant impact on the performance and durability of fuel cells.The delays in auxiliary equipments in fuel cell systems (such as pumps and heaters) and back pressures degrade system performance and lead to problems in controlling tuning parameters including temperature,pressure,and flow rate.To overcome this problem,fast and delay-free systems are necessary for predicting control signals.In this paper,we propose a neural network model to control the stack terminal voltage as a proper constant and improve system performance.This is done through an input air pressure control signal.The proposed artificial neural network was constructed based on a back propagation network.A fuel cell nonlinear model,with and without feed forward control,was investigated and compared under random current variations.Simulation results showed that applying neural network feed forward control can successfully improve system performance in tracking output voltage.Also,less energy consumption and simpler control systems are the other advantages of the proposed control algorithm. 展开更多
关键词 Feed forward control Neural network Proton exchange membrane (PEM) fuel cell Terminal voltage tracking