By the end of 1997, totally ten 300 MW grade W-flame double arch boilers, firing anthracite or meager coal, were operating in China. These W-flame boilers were designed and supplied separately by four different manufa...By the end of 1997, totally ten 300 MW grade W-flame double arch boilers, firing anthracite or meager coal, were operating in China. These W-flame boilers were designed and supplied separately by four different manufacturers in the world, using either their own technology or foreign patent. It is shown by a recent survey that all these boilers are having a normal operation. However, there is still some room to be improved, such as boiler furnace configuration. Also, for raising the burnout rate and avoiding local slagging, furnace volume and burner layout need to be deliberated. And the tineness of pulverized coal and the air / coal ratio need to be improved. Some suggestions are made in this paper for optimizing the boiler design, Test data for the minimum stable combustion load and NOx emission are given too.展开更多
In this paper,the designed features of a W-flame coal-fired boiler are introduced.A scheme of joint primary air for two boilers is made and technical measures are also taken based on corresponding analyses and studies...In this paper,the designed features of a W-flame coal-fired boiler are introduced.A scheme of joint primary air for two boilers is made and technical measures are also taken based on corresponding analyses and studies.The scheme and the measures provide a reference for technicians to improve the efficiencies and reduce the startup costs of other similar large boilers.展开更多
文摘By the end of 1997, totally ten 300 MW grade W-flame double arch boilers, firing anthracite or meager coal, were operating in China. These W-flame boilers were designed and supplied separately by four different manufacturers in the world, using either their own technology or foreign patent. It is shown by a recent survey that all these boilers are having a normal operation. However, there is still some room to be improved, such as boiler furnace configuration. Also, for raising the burnout rate and avoiding local slagging, furnace volume and burner layout need to be deliberated. And the tineness of pulverized coal and the air / coal ratio need to be improved. Some suggestions are made in this paper for optimizing the boiler design, Test data for the minimum stable combustion load and NOx emission are given too.
文摘In this paper,the designed features of a W-flame coal-fired boiler are introduced.A scheme of joint primary air for two boilers is made and technical measures are also taken based on corresponding analyses and studies.The scheme and the measures provide a reference for technicians to improve the efficiencies and reduce the startup costs of other similar large boilers.