The testing of thirteen reinforeed concrete (RC) beams strengthened by epoxy-bonded glass fiber reinforced plastic plate (GFRP) shows that the RC beam and the GFRP plate with epoxy bonding on it can work fairly we...The testing of thirteen reinforeed concrete (RC) beams strengthened by epoxy-bonded glass fiber reinforced plastic plate (GFRP) shows that the RC beam and the GFRP plate with epoxy bonding on it can work fairly well in coordination to eaeh other. But there is relative slipping between RC beam and GFRP plate. And the strain of GFRP and steel rebar of RC beam satisfies the quasi-plane-hypothesis, that is, the strain of longitudinal fiher that parallels to the neutral axis of plated beam within the scope of effective height ( h0 ) of the cross section is in direct proportion to the distance from the fiber to the neutral axis. The strain of GFRP and steel rebar satisfies the equation: εGFRP=Kεsteel.展开更多
Glass fiber reinforced plastics geogrid has a wide application in the field of soil reinforcement because of its high strength, good toughness, and resistance to environmental stress, creep resistance and strong stabi...Glass fiber reinforced plastics geogrid has a wide application in the field of soil reinforcement because of its high strength, good toughness, and resistance to environmental stress, creep resistance and strong stability. In order to get high-powered glass fiber reinforced plastics geogrid and its mechanical characteristics, the properties and physical mechanical index of geogrid have been got through the study of its raw material, production process and important quality index. The analysis and study have been made to the geogrid's mechanical properties with loading speed, three-axial compression, temperature tensile test and FLAC3D numerical simulation, thus obtain the mechanical parameters of its displacement time curve, breaking strength and elongation at break. Some conclusions can be drawn as follows: (a) Using glass fiber materials, knurling and coated projection process, the f^acture strength and corrosion resistance of geogrid are greatly improved and the interlocking bite capability of soil is enhanced. (b) The fracture strength of geogrid is related to temperature and loading rate. When the surrounding rock pressure is fixed, the strength and anti-deformation ability of reinforced soil are significantly enhanced with increasing reinforced layers. (c) The pullout test shows the positive correlation between geogrid displacement and action time. (d) As a new reinforced material, the glass fiber reinforced plastics geogrid is not mature enough in theoretical research and practical experience, so it has become an urgent problem both in theoretical study and practical innovation.展开更多
The damage formation and evolution of glass fiber reinforced plastics( GFRP) bar on mechanical properties were mainly evaluated by theoretical analysis and numerical calculations which lack of test basis of damage pro...The damage formation and evolution of glass fiber reinforced plastics( GFRP) bar on mechanical properties were mainly evaluated by theoretical analysis and numerical calculations which lack of test basis of damage process. The two different matrices of unsaturated polyester and vinylester GFRP bars were selected to carry out a series of macro-mesoscopic physical and mechanical tests to analyze the tensile progressive damage process on a multiscale. The formation of apparent crack,the bonding of internal components as well as the strain change were all reflected damage evolution of GFRP bar,and a certain correlation existed between them. Wherein the matrix has an obvious impact on the damage of bar,the component stress transfer effect of vinylester bar is better than unsaturated polyester from crack propagation observation and scanning electron microscopy( SEM). The cyclic loading tests quantitatively reflect the difference of damage accumulation between different matrix bars,and the failure load of bars decreases nearly 10%.展开更多
Three cumulative damage models are examined for the case of cyclic loading of AISI 6150 steel, S2 glass fibre/epoxy and E glass fibre/epoxy composites. The Palmgren-Miner, Broutman-Sahu and Hashin-Rotem models are com...Three cumulative damage models are examined for the case of cyclic loading of AISI 6150 steel, S2 glass fibre/epoxy and E glass fibre/epoxy composites. The Palmgren-Miner, Broutman-Sahu and Hashin-Rotem models are compared to determine which of the three gives the most accurate estimation of the fatigue life of the materials tested. In addition, comparison of the fatigue life of the materials shows the superiority of AISI 6150 steel and S2 glass fibre/epoxy at lower mean stresses, and that of steel to the composites at higher mean stresses.展开更多
The assembled form of thick-wall glass fiber reinforced plastics (GFRP) tube and 0Cr18Ni9 austenitic stainless steel pipes was designed as the radius thermal-insulating and load-supporting structure in cryogenic vesse...The assembled form of thick-wall glass fiber reinforced plastics (GFRP) tube and 0Cr18Ni9 austenitic stainless steel pipes was designed as the radius thermal-insulating and load-supporting structure in cryogenic vessels. In order to study the thermal leakage and gap changes on the support structure, as well as radius temperature and stress distribution on GFRP tube, an experimental investigation has been taken. The results indicate that the support structure is proved to fit well as thermal-insulating and load-supporting part in cryo-genic vessels, furthermore has high security during cryogenic applications.展开更多
基金Sponsored by the Natural Science Foundation of Henan Province(Grant No.004041700).
文摘The testing of thirteen reinforeed concrete (RC) beams strengthened by epoxy-bonded glass fiber reinforced plastic plate (GFRP) shows that the RC beam and the GFRP plate with epoxy bonding on it can work fairly well in coordination to eaeh other. But there is relative slipping between RC beam and GFRP plate. And the strain of GFRP and steel rebar of RC beam satisfies the quasi-plane-hypothesis, that is, the strain of longitudinal fiher that parallels to the neutral axis of plated beam within the scope of effective height ( h0 ) of the cross section is in direct proportion to the distance from the fiber to the neutral axis. The strain of GFRP and steel rebar satisfies the equation: εGFRP=Kεsteel.
基金Funded by National Natural Science Foundation of China(No.41372289)the Shandong Province Higher Educational Science and Technology Program(No.12LH03)+1 种基金the China's Post-doctoral Science Fund(No.2012M521365)the SDUST Research Fund
文摘Glass fiber reinforced plastics geogrid has a wide application in the field of soil reinforcement because of its high strength, good toughness, and resistance to environmental stress, creep resistance and strong stability. In order to get high-powered glass fiber reinforced plastics geogrid and its mechanical characteristics, the properties and physical mechanical index of geogrid have been got through the study of its raw material, production process and important quality index. The analysis and study have been made to the geogrid's mechanical properties with loading speed, three-axial compression, temperature tensile test and FLAC3D numerical simulation, thus obtain the mechanical parameters of its displacement time curve, breaking strength and elongation at break. Some conclusions can be drawn as follows: (a) Using glass fiber materials, knurling and coated projection process, the f^acture strength and corrosion resistance of geogrid are greatly improved and the interlocking bite capability of soil is enhanced. (b) The fracture strength of geogrid is related to temperature and loading rate. When the surrounding rock pressure is fixed, the strength and anti-deformation ability of reinforced soil are significantly enhanced with increasing reinforced layers. (c) The pullout test shows the positive correlation between geogrid displacement and action time. (d) As a new reinforced material, the glass fiber reinforced plastics geogrid is not mature enough in theoretical research and practical experience, so it has become an urgent problem both in theoretical study and practical innovation.
基金National Natural Science Foundation of China(No.51278391)Huazhong University of Science and Technology Analytical and Testing Center,China
文摘The damage formation and evolution of glass fiber reinforced plastics( GFRP) bar on mechanical properties were mainly evaluated by theoretical analysis and numerical calculations which lack of test basis of damage process. The two different matrices of unsaturated polyester and vinylester GFRP bars were selected to carry out a series of macro-mesoscopic physical and mechanical tests to analyze the tensile progressive damage process on a multiscale. The formation of apparent crack,the bonding of internal components as well as the strain change were all reflected damage evolution of GFRP bar,and a certain correlation existed between them. Wherein the matrix has an obvious impact on the damage of bar,the component stress transfer effect of vinylester bar is better than unsaturated polyester from crack propagation observation and scanning electron microscopy( SEM). The cyclic loading tests quantitatively reflect the difference of damage accumulation between different matrix bars,and the failure load of bars decreases nearly 10%.
文摘Three cumulative damage models are examined for the case of cyclic loading of AISI 6150 steel, S2 glass fibre/epoxy and E glass fibre/epoxy composites. The Palmgren-Miner, Broutman-Sahu and Hashin-Rotem models are compared to determine which of the three gives the most accurate estimation of the fatigue life of the materials tested. In addition, comparison of the fatigue life of the materials shows the superiority of AISI 6150 steel and S2 glass fibre/epoxy at lower mean stresses, and that of steel to the composites at higher mean stresses.
文摘The assembled form of thick-wall glass fiber reinforced plastics (GFRP) tube and 0Cr18Ni9 austenitic stainless steel pipes was designed as the radius thermal-insulating and load-supporting structure in cryogenic vessels. In order to study the thermal leakage and gap changes on the support structure, as well as radius temperature and stress distribution on GFRP tube, an experimental investigation has been taken. The results indicate that the support structure is proved to fit well as thermal-insulating and load-supporting part in cryo-genic vessels, furthermore has high security during cryogenic applications.