期刊文献+
共找到1,149篇文章
< 1 2 58 >
每页显示 20 50 100
Nd:YAG water mist laser treatment for giant gestational gingival tumor: A case report
1
作者 Hong-Yu Chen Jun-Ji Xu +1 位作者 Xiu-Lin Chang Pei Wu 《World Journal of Clinical Cases》 SCIE 2024年第11期1974-1979,共6页
BACKGROUND This case of gestational gingival tumor is huge and extremely rare in clinical practice.As the growth location of this gingival tumor is in the upper anterior tooth area,it seriously affects the pregnant wo... BACKGROUND This case of gestational gingival tumor is huge and extremely rare in clinical practice.As the growth location of this gingival tumor is in the upper anterior tooth area,it seriously affects the pregnant woman's speech and food,causing great pain to the patient.The use of Nd:YGA water mist laser to remove the gingival tumor resulted in minimal intraoperative bleeding,minimal adverse reactions,and good postoperative healing,which is worthy of clinical promotion and application.CASE SUMMARY The patient,a pregnant woman,reported a large lump in her mouth on the first day of postpartum treatment.Based on medical history and clinical examination,the diagnosis was diagnosed as gestational gingival tumor.Postoperative pathological biopsy also confirmed this diagnosis.The use of Nd:YAG water mist laser to remove the tumor resulted in minimal intraoperative bleeding,clear surgical field of view,short surgical time,and good postoperative healing.CONCLUSION In comparison to traditional surgery,Nd:YAG water mist laser surgery is minimally invasive,minimizes cell damage,reduces bleeding,ensures a clear field of vision,and virtually eliminates postoperative edema,carbonization,and the risk of cross infection.It has unique advantages in oral soft tissue surgery for pregnant patients.Therefore,the clinical application of Nd:YAG water mist laser for the treatment of gestational gingival tumors is an ideal choice. 展开更多
关键词 Gestational gingival tumor Nd:YAG water mist laser Granulomatous gingival tumor Minimally invasive dentistry Pregnancy related diseases Oral soft tissue surgery Case report
下载PDF
Numerical Simulation Analysis of the Transformer Fire Extinguishing Process with a High-Pressure Water Mist System under Different Conditions 被引量:1
2
作者 Haowei Yao Youxin Li +7 位作者 Kefeng Lv Dong Wang Jinguang Zhang Zhenyu Zhan Zhenyu Wang Huaitao Song Xiaoge Wei Hengjie Qin 《Computer Modeling in Engineering & Sciences》 SCIE EI 2023年第7期733-747,共15页
To thoroughly study the extinguishing effect of a high-pressure water mist fire extinguishing system when a transformer fire occurs,a 3D experimental model of a transformer is established in this work by employing Fir... To thoroughly study the extinguishing effect of a high-pressure water mist fire extinguishing system when a transformer fire occurs,a 3D experimental model of a transformer is established in this work by employing Fire Dynamics Simulator(FDS)software.More specifically,by setting different parameters,the process of the highpressure water mist fire extinguishing system with the presence of both diverse ambient temperatures and water mist sprinkler laying conditions is simulated.In addition,the fire extinguishing effect of the employed high-pressure water mist system with the implementation of different strategies is systematically analyzed.The extracted results show that a fire source farther away fromthe centerline leads to a lower local temperature distribution.In addition,as the ambient temperature increases,the temperature above the fire source decreases,while the temperature and the concentrationof theupperflue gas layer bothdecrease.Interestingly,after thehigh-pressurewatermist sprinkler begins to operate,both the temperature distribution above the fire source and the concentration of the flue gas decrease,which indicates that the high-pressure water mist system plays the role of cooling and dust removal.By comparing various sprinkler laying methods,it is found that the lower sprinkler height has a better effect on the temperature above the fire source,the temperature of the upper flue gas layer,and the concentration of the flue gas.Moreover,when the sprinkler is spread over thewhole transformer,the cooling effect on both the temperature above the fire source and the temperature of the upper flue gas layer is good,whereas the change in the concentration of the flue gas above the fire source is not obvious compared to the case where the sprinkler is not fully spread. 展开更多
关键词 Transformer fire high-pressure water mist TEMPERATURE flue gas concentration
下载PDF
Combined effects of obstacle and fine water mist on gas explosion characteristics 被引量:5
3
作者 Xiaoping Wen Mengming Wang +2 位作者 Fahui Wang Minggao Yu Haoxin Deng 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2021年第12期131-140,共10页
Combined effects of obstacles and fine water mist on a methane-air explosion of a semi-closed pipe were investigated experimentally.In this study,the diameter of the water mist,the location,and the number of obstacles... Combined effects of obstacles and fine water mist on a methane-air explosion of a semi-closed pipe were investigated experimentally.In this study,the diameter of the water mist,the location,and the number of obstacles was considered.The results demonstrated that 5 μm water mist present a significant suppression affected while 45 μm shows a slight promotion effected on a gas explosion of the condition without obstacles.In the presence of an obstacle,however,the inhibitory effect of 5 μm water veils of mist dropped significantly during flame propagation,and the effect of 45 μm water veils of mist changed from the enhancement of inhibition,and its inhibitory effect was significant.The inhibitory effect of 45 μm water veils of mist on gas explosion weakened firstly and then enhanced with the increasing distance between obstacle location from the ignition location as well as in several obstacles. 展开更多
关键词 Fine water mist Gas explosion suppression OBSTACLE Couple effects
下载PDF
Performance assessment of water mist applied in gas burning suppression in underground coal mine 被引量:6
4
作者 余明高 郑立刚 +3 位作者 刘志超 潘荣锟 贾海林 袁俊 《Journal of Coal Science & Engineering(China)》 2006年第2期48-52,共5页
The main objective of the present study was introduced water mist suppressiontechnology to prevent and control gas burning which occurred during drilling at Wu20160working-face in No.10 coal mine of Pingdingshan Ltd..... The main objective of the present study was introduced water mist suppressiontechnology to prevent and control gas burning which occurred during drilling at Wu20160working-face in No.10 coal mine of Pingdingshan Ltd..Based on the self-developed ex-periment platform,a series of fire suppression tests to evaluate the performance of a watermist system were conducted.The detailed measurements of the spray characteristics,i.e.,the Sauter Mean Diameter(SMD),the velocity and spray angle which are the main pa-rameters considered in the Study,were obtained by using LS-2000 Sizer.The amount ofwater consumed and the water flux density distribution over the cross section downstreamthe nozzle exit were measured by cup collector method.The operating pressure of thewater mist nozzle is set to 0.5 MPa,the droplet SMD of 104 pm,the water flux density dis-tribution from 0.71 to 8.47 L/(m^2.min),the average velocity of 2.14 m/s.The experimentalresults show that the averaged time required for extinguishment is 3.14 s,and the corre-sponding amount of water used during fire test is about 0.11 kg.The gas fire suppressionsystem reduces the temperature in combustion chamber of the experimental apparatusbelow the ignition point of the gas,which can effectively avoid the occurrence of the gasfire in coal mine. 展开更多
关键词 gas burning water mist coal mine fire suppression performance assessment
下载PDF
Coal combustion restrained by ultra-fine water mist in confined space 被引量:1
5
作者 YU Ming-gao YANG Ke +2 位作者 JIA Hai-lin LU Chang LU Lai-xiang 《Mining Science and Technology》 EI CAS 2009年第5期574-579,共6页
In order to apply ultra-fine water mist technology on spontaneous coal combustion in the goaf of a coal mine, we built a small scale compartment with ultra-fine water mist for restraining coal combustion in a confined... In order to apply ultra-fine water mist technology on spontaneous coal combustion in the goaf of a coal mine, we built a small scale compartment with ultra-fine water mist for restraining coal combustion in a confined space and then investigated the restraining efficiency and related factors. The study obtained the following results: a descending rate of heat release, an increase in 02, the production of CO2 decreased gradually, while the production of CO increased dramatically and quickly and then decreased; ultimately it tended to become stable after the discharge of an ultra-fine water mist. The technology showed that the ultra-fine water mist can effectively reduce the heat release rate of coal and the rate to generate components. We found that the restraining effect relied on the mist flux, the discharge time and other factors. A sufficient amount of mist has a better effect compared to an insufficient amount of mist. To combat coal combustion, the greater the discharge time, the better coal flames are extinguished. 展开更多
关键词 ultra-fine water mist coal combustion mist flux discharge time
下载PDF
Research on the effect of the component proportion in the new water mist additive on firefighting performance 被引量:1
6
作者 Ji Huanle Zhang Qingsong +1 位作者 Wu Binbin Liang Tianshui 《Engineering Sciences》 EI 2013年第6期85-90,共6页
Water mist technology provides efficient firefighting performance while there is still room for improvement. So varieties of additives have been studied in recent years both at home and abroad. The self-made additives... Water mist technology provides efficient firefighting performance while there is still room for improvement. So varieties of additives have been studied in recent years both at home and abroad. The self-made additives are used to compare the firefighting performance of diesel and heptane fire in open space. By adjusting the concentration of substance in the additives and conducting the experiment under the pressure of 0.3 MPa,0.5 MPa and 0.7 MPa,extinguish time and temperature are measured in the experiment. Through the experiments using different fuels,it can be found when the fuel is heptane that has a lower ignition point and a higher evaporation rate, the water mist additive can still significantly improve the firefighting performance. According to the data based on different concentrations of fluorinated surfactants,we find that fluorinated surfactants are the main substance to improve the performances by changing physical property of water mist. Optimal proportion of the additives for firefighting performance is found by experiment results. 展开更多
关键词 water mist additive firefighting performance additive proportion fire extinguishing mechanisms
下载PDF
A Numerical Study on the Extinguishing Performances of High-Pressure Water Mist on Power-Transformer Fires for Different Flow Rates and Particle Velocities
7
作者 Yongheng Ku Jinguang Zhang +2 位作者 Zhenyu Wang Youxin Li Haowei Yao 《Fluid Dynamics & Materials Processing》 EI 2021年第6期1077-1090,共14页
In order to study the extinguishing performance of high-pressure-water-mist-based systems on the fires originating from power transformers the PyroSim software is used.Different particle velocities and flow rates are ... In order to study the extinguishing performance of high-pressure-water-mist-based systems on the fires originating from power transformers the PyroSim software is used.Different particle velocities and flow rates are considered.The evolution laws of temperature around transformer,flue gas concentration and upper layer temperature of flue gas are analyzed under different boundary conditions.It is shown that the higher the particle velocity is,the lower the smoke concentration is,the better the cooling effect on the upper layer temperature of flue gas layer is,the larger the flow rate is and the better the cooling effect is. 展开更多
关键词 High-pressure water mist transformer fire particle velocity smoke concentration
下载PDF
Suppression of methane/air explosion by water mist with potassium halide additives driven by CO2 被引量:4
8
作者 Wei Tan Dong Lü +2 位作者 Liyan Liu Guorui Zhu Nan Jiang 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2019年第11期2742-2748,共7页
To enhance the explosion suppression effects of water mist, various potassium halide additives were tested in a confined vessel filled with a 10% mixture of methane/air. Air and CO2(0.7 MPa) were used as driver gases.... To enhance the explosion suppression effects of water mist, various potassium halide additives were tested in a confined vessel filled with a 10% mixture of methane/air. Air and CO2(0.7 MPa) were used as driver gases. The results revealed that halide additives exhibit considerable suppression effects on explosion overpressure. A30% KI mist decreased the explosion overpressure by 27.46% compared with the suppression by pure water mist under the same conditions. When CO2 is used as the driver gas, it will dissolve in water under high pressure.The synergistic effect of a CO2 solution with an effective additive afforded significant suppression. Under the same conditions, the overpressures suppressed by a mist of 30% KI + 0.7 MPa CO2 solution decreased by 33.53% compared with those suppressed by pure water mist driven by air. The synergistic suppression effect is much better than that of a 0.7 MPa CO2 solution mist or 30% KI mist alone. The multicomponent additives can be considered when suppressing methane/air explosions with pressure-formed water mist. 展开更多
关键词 METHANE Explosion SUPPRESSION water mist HALIDE CO2
下载PDF
Implications of fine water mist environment on the post-detonation processes of a PE4 explosive charge in a semi-confined blast chamber 被引量:6
9
作者 Zetu Jiba Tleyane Jonas Sono Frederik Johannes Mostert 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2018年第5期366-372,共7页
The effects of a fine water mist environment in a semi-confined blast chamber on the chemical and thermodynamic processes following detonation of a 20 g PE4 explosive charge have been investigated.The effects were qua... The effects of a fine water mist environment in a semi-confined blast chamber on the chemical and thermodynamic processes following detonation of a 20 g PE4 explosive charge have been investigated.The effects were quantified by the analysis of pressure profiles recorded where several parameters including arrival time of the shock at the sensors, peak overpressures, specific impulse of the positive phase, period of the negative phase and the specific impulse of the multiple reflections were quantified.The effect of the fine water mist on the arrival time, peak pressures and the specific impulse of the positive phase agrees with previous findings in literature. In this paper, the focus is on the implications of the fine water mist on the negative phase and the impulse of multiple pressure reflections. The period of the negative phase was found to have increased by 40% and with higher negative peak pressure in the mist condition compared to the atmospheric condition. The activities of the multiple pressure reflections were found to have decreased considerably, both in number and in amplitude leading to lower impulses(by about 60%) for the water mist conditions. 展开更多
关键词 FINE water mist BLAST mitigation Semi-confined BLAST chamber Negative phase PRESSURE Multiple PRESSURE reflections
下载PDF
A Study on Flow Structure around a Bridge Beam and Behavior of Sea Water Mist 被引量:1
10
作者 Masaaki Ishikawa 《Open Journal of Fluid Dynamics》 2017年第3期340-347,共8页
Okinawa in the subtropical islands enclosed in the ocean has a problem that corrosion of structures progresses quickly because of high temperature, high humidity and adhesion of sea-water mists flying from sea. Author... Okinawa in the subtropical islands enclosed in the ocean has a problem that corrosion of structures progresses quickly because of high temperature, high humidity and adhesion of sea-water mists flying from sea. Author is interested in corrosion of bridge made of weatherability steel. Therefore, it needs to investigate the flow structure around bridge beams and behavior of sea-water mist (droplet). In this paper, flow visualization and PIV are attempted to understand the flow structures around bridge beams and, furthermore, numerical approach of motion of droplets is attempted to understand the collision of sea-water mists on the bridge wall. 展开更多
关键词 Flow Visualization PIV BEHAVIOR of SEA-water mist
下载PDF
Study on variation of smoke component concentration with water mist applying
11
作者 Fang Yudong 《Engineering Sciences》 EI 2014年第3期58-64,共7页
Interaction between water mist and fire smoke is studied by experiments in an ISO 9705 room, The variation of 02, CO and CO2 concentration is disclosed, and the mathematical models of smoke component con- centration w... Interaction between water mist and fire smoke is studied by experiments in an ISO 9705 room, The variation of 02, CO and CO2 concentration is disclosed, and the mathematical models of smoke component con- centration with water mist pressure and ventilation speed are established according to the experimental results. It is found in the experiment that the smoke component concentration will break when ventilation speed exceeds 1.5 kg/s. This paper provides necessary theory for water mist technology using in smoke restraining. 展开更多
关键词 water mist O2 CO CO2
下载PDF
Analysis of Water Mist Suppression with Foam Additive in Wind Generator
12
作者 Chen-Wei Chiu Yin-Tsz Lin Yi-Liang Shu 《Journal of Hydraulic Engineering》 2015年第1期12-26,共15页
The study adopted a 20-foot long container to simulate the situation inside a turbine cabin. Water mist sprays were installed internally and used to perform fire extinguishing tests. Under these different scenarios, s... The study adopted a 20-foot long container to simulate the situation inside a turbine cabin. Water mist sprays were installed internally and used to perform fire extinguishing tests. Under these different scenarios, several operating factors were adjusted with the results of each adjustment subsequently measured. The operating factors studied included: operating pressures, foam concentrations, cabin opening issues, and obstacles. Each of the factors was compared with the others so as to find out which combinations would be most suitable for a water mist spray system installed inside a wind turbine cabin. The presence of obstructions hinders the direct impact of the mist spray on the fire source and in average an additional 2 to 3 minutes is required to put out the fire. This study found that the effect of the foam-water ratio is linear. Regardless of the scenario, the optimum mixture ratio is 3%. The line graph shows that the most unsuitable aqueous film-forming mixture ratio is 6%. This experiment found that the main fire extinguishing mechanism of water mist spray is the cooling of a large area via water droplets. This system is very effective in bringing down the temperature. The addition of foam in water mist spray, however, impaired the effectiveness of the cooling effect although the fire control mechanism via emulsification markedly reduced the time required to put out the fire. The increase in foam magnification will considerably enhance the fire extinguishing efficiency. 展开更多
关键词 TURBINE cabins water mist water droplets foam magnification fire extinguishing efficiency.
下载PDF
Fire Extinct Experiments with Water Mist by Adding Additives 被引量:3
13
作者 Lijun Yang Jianbo Zhao 《Journal of Thermal Science》 SCIE EI CAS CSCD 2011年第6期563-569,共7页
The effects of fire extinguishment with water mist by adding different additives were studied.Tens of chemical substances (including alkali metal salt,dilution agent and surface active agent) were selected as additive... The effects of fire extinguishment with water mist by adding different additives were studied.Tens of chemical substances (including alkali metal salt,dilution agent and surface active agent) were selected as additives due to their different extinct mechanisms.At first the performance of fire extinguishment with single additive was studied,then the effects of the same kinds of chemical substances under the same mass fraction were compared to study their influences on the fire extinguishment factors,including extinct time,fire temperature and oxygen concentration from which the fire extinct mechanism with additives could be concluded.Based on this the experiments were conducted to study the cooperate effect of the complexity of different additives.It indicated the relations between different firefighting mechanisms and different additives were competitive.From a large number of experiments the extinct mechanism with water mist by adding additives was concluded and an optimal compounding additive was selected. 展开更多
关键词 fire extinguishment ADDITIVES water mist
原文传递
Study on fire extinguishing performance of ultrafine water mist in a cup burner 被引量:2
14
作者 LIANG TianShui LIAO GuangXuan +1 位作者 LU SiuMing WANG XiShi 《Science China(Technological Sciences)》 SCIE EI CAS 2012年第7期1982-1987,共6页
Two simplified models for predicting minimum extinguishing concentration(MEC) of ultrafine water mist(UFM)(<10 m) were developed based on limiting oxygen concentration(LOC) and combustion limit temperature(CLT),res... Two simplified models for predicting minimum extinguishing concentration(MEC) of ultrafine water mist(UFM)(<10 m) were developed based on limiting oxygen concentration(LOC) and combustion limit temperature(CLT),respectively.Experiment was conducted using a modified cup burner which can reduce the surface adsorption of UFM.Two typical liquid fuels,n-heptane and ethanol,were used in the experiment.Tests using the same scenario were repeated 20 times or 10 times according to the variance of extinguishing time.The average and the standard deviations of extinguishing time were used to evaluate the fire extinguishing performance of UFM.Experimental results agree well with the model based on LOC,and disagree with the model based on CLT.The disagreements were explained by analyzing flow behavior of UFM.It was concluded that the primary mechanism of fire extinguishment with UFM was oxygen dilution. 展开更多
关键词 water mist limiting oxygen concentration combustion limit temperature extinguishing concentration cup burner
原文传递
Experiment and Prediction of Fire Extinguishment with Water Mist in an Enclosed Room 被引量:2
15
作者 Jianbo Zhao Lijun Yang 《Journal of Thermal Science》 SCIE EI CAS CSCD 2013年第1期71-79,共9页
The correlation between oxygen concentration and fire temperature when fire was extinguished with water mist was theoretically studied. The Semenov theory was applied to analyze the critical condition when fire was ex... The correlation between oxygen concentration and fire temperature when fire was extinguished with water mist was theoretically studied. The Semenov theory was applied to analyze the critical condition when fire was extin- guished with water mist, from which the correlation could be obtained. The water mist experiments were carded out by varying the fire size, atomizer number, ceiling height, system pressure, and pre-burn time in an enclosed room. The oxygen concentration near the edge of the liquid pool and the fire temperature above the center of the liquid pool were measured. A comparison of the experimental data with the correlation was made under different conditions. The results showed that fire extinguishment was a stochastic process which could be affected by many factors. This theoretical model could predict the correlation between ftre temperature and oxygen concentration when fire was extinguished with water mist in an enclosed room and it can also be treated as a critical condition for fire extinguishment. 展开更多
关键词 water mist fire temperature oxygen concentration
原文传递
Calculation of fire extinguishment time with water mist in an enclosed room 被引量:2
16
作者 Lijun Yang Jianbo Zhao Zhenyu Xu 《Journal of Thermal Science》 SCIE EI CAS CSCD 2010年第6期561-566,共6页
The fire extinguishment time is a major factor to evaluate the efficiency of fire extinguishment with water mist. In this paper the fire extinguishment time with water mist in an enclosed room is calculated. Before ad... The fire extinguishment time is a major factor to evaluate the efficiency of fire extinguishment with water mist. In this paper the fire extinguishment time with water mist in an enclosed room is calculated. Before adding water mist, the chemical kinetics plays the role in combustion, where a dimensionless math model is established by us-ing the Semenov theory. After adding water mist, the diffusion plays the role instead. Then another math model containing water mist and dominated by oxygen concentration is established. The fire temperature is integrated from Tm to extinguishment temperature TB and the extinguishment time can be obtained. The calculated values are compared with the experimental data under different conditions. The results show that this model can predict the fire extinguishment time accurately. Besides, this model also can be used to determine the critical water mist flux and evaluate which fire extinguishment mechanisms dominate the extinguishment. 展开更多
关键词 extinguishment time minimum flux water mist
原文传递
Water Content Effect on Oxides Yield in Gas and Liquid Phase Using DBD Arrays in Mist Spray 被引量:1
17
作者 陈秉岩 朱昌平 +7 位作者 费峻涛 何湘 殷澄 王媛 蒋永锋 陈龙威 高远 韩庆邦 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第1期41-50,共10页
Electric discharge in and in contact with water can accompany ultraviolet(UV)radiation and electron impact, which can generate a large number of active species such as hydroxyl radicals(OH), oxygen radical(O), o... Electric discharge in and in contact with water can accompany ultraviolet(UV)radiation and electron impact, which can generate a large number of active species such as hydroxyl radicals(OH), oxygen radical(O), ozone(O_3) and hydrogen peroxide(H_2O_2). In this paper, a nonthermal plasma processing system was established by means of dielectric barrier discharge(DBD)arrays in water mist spray. The relationship between droplet size and water content was examined,and the effects of the concentrations of oxides in both treated water and gas were investigated under different water content and discharge time. The relative intensity of UV spectra from DBD in water mist was a function of water content. The concentrations of both O_3 and nitrogen dioxide(NO_2) in DBD room decreased with increasing water content. Moreover, the concentrations of H_2O_2, O_3 and nitrogen oxides(NOx) in treated water decreased with increasing water content,and all the ones enhanced after discharge. The experimental results were further analyzed by chemical reaction equations and commented by physical principles as much as possible. At last,the water containing phenol was tested in this system for the concentration from 100 mg/L to9.8 mg/L in a period of 35 min. 展开更多
关键词 dielectric barrier discharge(DBD) water mist spray water content hydrogen peroxide ozone nitrogen oxides
下载PDF
Progress in research and application of water mist fire suppression technology 被引量:15
18
作者 LIU Jianghong, LIAO Guangxuan, LI Peide, FAN Weicheng & LU Qiang State Key Laboratory of fire Science, University of Science and Tech-nology of China, Hefei 230026, China Correspondence should be addressed to Liu Jianghong (e-mail: ljh@ ustc.edu.cn) 《Chinese Science Bulletin》 SCIE EI CAS 2003年第8期718-725,共8页
Water mist technology in fire suppression has been a subject of many investigations over the last decade. This paper introduces the concept of water mist technology and discusses its extinguishment mechanisms in compa... Water mist technology in fire suppression has been a subject of many investigations over the last decade. This paper introduces the concept of water mist technology and discusses its extinguishment mechanisms in comparison with other fire suppression systems briefly. A survey is made on the recent applications of water mist for (1) Class B spray and pool fires in machinery spaces, gas turbine enclosures, combat vehicles, and flammable liquid storage rooms; (2) Class A fires in residential occupancies, marine accommoda-tions and public spaces, heritage buildings and libraries; (3) Class C fires in electronic equipment and computer rooms; and (4) the fires in aircraft onboard cabin and cargo com-partments. The paper proceeds to review some new applica-tions of water mist for the Class K fires in commercial cook rooms. Use of water mist for total-ship protection as well as the fire protection of heavy goods vehicle shuttle trains is also investigated. At last, the up-to-date development of corresponding test to evaluate the capabilities and limitaions of water mist is discussed. 展开更多
关键词 水雾灭火技术 灭火机制 比较分析 效果评价
原文传递
Experimental Evaluation of Water Mist with Metal Chloride Additives for Suppressing CH_4 /Air Cup-Burner Flames 被引量:4
19
作者 Jianghong Liu Beihua Cong 《Journal of Thermal Science》 SCIE EI CAS CSCD 2013年第3期269-274,共6页
In order to investigate the fire suppression effectiveness of water mist with metal chloride additives, ultrafine water mists of these salts with diameters about 10μm were introduced into CH4 /air non-premixed flame ... In order to investigate the fire suppression effectiveness of water mist with metal chloride additives, ultrafine water mists of these salts with diameters about 10μm were introduced into CH4 /air non-premixed flame in the cup burner. Results showed that these droplets hard to make itself to the flame front under the cup burner flow conditions functioned as a carrier of the vaporized solid particles or its decomposed materials. The metal chloride improved fire suppression efficacy of water mist which were affected by the type and concentration of metal chloride. On a mass basis, there is a fire suppression effectiveness relationship of MgCl2 <CaCl2 <NaCl<KCl< MnCl2 <FeCl2 . The flame suppression ability of water solution/metal chlorides improves as the concentration of metal chlorides increase. However, upper additive limits exist due to the associated limiting vapour pressure of the additive. 展开更多
关键词 additive water mist FIRE suppression CH4 AIR FIRE
原文传递
Experimental studies on interaction of water mist with class K fires 被引量:4
20
作者 FANG Yudong ZHANG Yongfeng LIN Lin LIAO Guangxuan HUANG Xin CONG Beihua 《Chinese Science Bulletin》 SCIE EI CAS 2006年第24期3053-3058,共6页
Interaction of water mist with cooking oil fires is studied experimentally and theoretically. A LDV/APV system is used to measure the velocity and diameter of water mist at different pressures in the experiments,and t... Interaction of water mist with cooking oil fires is studied experimentally and theoretically. A LDV/APV system is used to measure the velocity and diameter of water mist at different pressures in the experiments,and the effect of water mist velocity and diameter on fire extinguishment efficiency is investi-gated. The experimental results show that water mist has excellent surface cooling effect; it can control and extinguish cooking oil fires quickly without re-ignition. The critical temperature (Tfo) is calculated by energy balance equation,and the fire plume momentum is calculated and compared with that of water mist in order to determine the critical velocity (νwy) of fire extinguishment. This paper provides references for cooking oil fires extinguishment with water mist. 展开更多
关键词 水雾 K级火灾 食用油 油类燃烧 重新起火 灭火效果
原文传递
上一页 1 2 58 下一页 到第
使用帮助 返回顶部