期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
Analysis of the Pipe Heat Loss of the Water Flow Calorimetry System in EAST Neutral Beam Injector
1
作者 HU Chundong CHEN Yu +4 位作者 XU Yongjian YU Ling LI Xiang ZHANG Weitang NBI Group 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第11期1139-1142,共4页
Neutral beam injection heating is one of the main auxiliary heating methods in controllable nuclear fusion research. In the EAST neutral beam injector, a water flow calorimetry (WFC) system is applied to measure the... Neutral beam injection heating is one of the main auxiliary heating methods in controllable nuclear fusion research. In the EAST neutral beam injector, a water flow calorimetry (WFC) system is applied to measure the heat load on the electrode system of the ion source and the heat loading components of the beamline. Due to the heat loss in the return water pipe, there are some measuring errors for the current WFC system. In this paper, the errors were measured experimentally and analyzed theoretically, which lay a basis for the exact calculation of beam power deposition distribution and neutralization efficiency. 展开更多
关键词 water flow calorimetry power deposition neutral beam injection heat loss