A field study on the estimation and analysis of iron stability in drinking water distribution system was carried out in a city of China. The stability of iron ion was estimated by pC-pH figure. It was found that iron ...A field study on the estimation and analysis of iron stability in drinking water distribution system was carried out in a city of China. The stability of iron ion was estimated by pC-pH figure. It was found that iron ion was unstable, with a high Fe (OH)3 precipitation tendency and obvious increase in turbidity. The outer layer of the corrosion scale was compact, while the inner core was porous. The main composition of the scale was iron, and the possible compound constitutes of the outer scale were α-FeOH, γ-FeOOH, α-Fe2O3, γ-F2O3, FeCl3, while the inner were Fe3O4, FeCl2, FeCO3. According to the characteristics of the corrosion scale, it was thought that the main reason for iron instability was iron release from corrosion scale. Many factors such as pipe materials, dissolved oxygen and chlorine residual affect iron release. Generally, higher iron release occurred with lower dissolved oxygen or chlorine residual concentration, while lower iron release occurred with higher dissolved oxygen or chlorine residual concentration. The reason was considered that the passivated out layer of scale of ferric oxide was broken down by reductive reaction in a condition of low oxidants concentration, which would result more rapid corrosion of the nine and red water phenomenon.展开更多
The water distribution system of one residential district in Tianjin is taken as an example to analyze the changes of water quality.Partial least squares(PLS) regression model,in which the turbidity and Fe are regarde...The water distribution system of one residential district in Tianjin is taken as an example to analyze the changes of water quality.Partial least squares(PLS) regression model,in which the turbidity and Fe are regarded as control objectives,is used to establish the statistical model.The experimental results indicate that the PLS regression model has good predicted results of water quality compared with the monitored data.The percentages of absolute relative error(below 15%,20%,30%) are 44.4%,66.7%,100%(turbidity) and 33.3%,44.4%,77.8%(Fe) on the 4th sampling point;77.8%,88.9%,88.9%(turbidity) and 44.4%,55.6%,66.7%(Fe) on the 5th sampling point.展开更多
Water leaving the treatment works is usually of a high quality but its properties change during the transportation stage. Increasing awareness of the quality of the service provided within the water industry today and...Water leaving the treatment works is usually of a high quality but its properties change during the transportation stage. Increasing awareness of the quality of the service provided within the water industry today and assessing the reliability of the water quality in a distribution system has become a major significance for decision on system operation based on water quality in distribution networks. Using together a water age model, a chlorine decay model and a model of acceptable maximum water age can assess the reliability of the water quality in a distribution system. First, the nodal water age values in a certain complex distribution system can be calculated by the water age model. Then, the acceptable maximum water age value in the distribution system is obtained based on the chlorine decay model. The nodes at which the water age values are below the maximum value are regarded as reliable nodes. Finally, the reliability index on the percentile weighted by the nodal demands reflects the reliability of the water quality in the distribution system. The approach has been applied in a real water distribution network. The contour plot based on the water age values determines a surface of the reliability of the water quality. At any time, this surface is used to locate high water age but poor reliability areas, which identify parts of the network that may be of poor water quality. As a result, the contour water age provides a valuable aid for a straight insight into the water quality in the distribution system.展开更多
A leak detection method based on Bayesian theory and Fisher’s law was developed for water distribution systems. A hydraulic model was associated with the parameters of leaks (location, extent). The randomness of para...A leak detection method based on Bayesian theory and Fisher’s law was developed for water distribution systems. A hydraulic model was associated with the parameters of leaks (location, extent). The randomness of parameter values was quantified by probability density function and updated by Bayesian theory. Values of the parameters were estimated based on Fisher’s law. The amount of leaks was estimated by back propagation neural network. Based on flow characteristics in water distribution systems, the location of leaks can be estimated. The effectiveness of the proposed method was illustrated by simulated leak data of node pressure head and flow rate of pipelines in a test pipe network, and the leaks were spotted accurately and renovated on time.展开更多
A combined first and second-order model, which includes bulk decay and wall decay, was developed to describe chlorine decay in water distribution systems. In the model the bulk decay has complex relationships with tot...A combined first and second-order model, which includes bulk decay and wall decay, was developed to describe chlorine decay in water distribution systems. In the model the bulk decay has complex relationships with total organic carbon (TOC), the initial chlorine concentration and the temperature. Except for the initial stages they can be simplified into a linear increase with TOC, a linear decrease with initial chlorine concentration and an exponential relationship with the temperature. The model also explains why chlorine decays rapidly in the initial stages. The parameters of model are determined by deriving the best fitness with experimental data. And the accuracy of model has been verified by using the experimental data and the monitoring data in a distribution system.展开更多
In order to compare two advanced multi-objective evolutionary algorithms,a multi-objective water distribution problem is formulated in this paper.The multi-objective optimization has received more attention in the wat...In order to compare two advanced multi-objective evolutionary algorithms,a multi-objective water distribution problem is formulated in this paper.The multi-objective optimization has received more attention in the water distribution system design.On the one hand the cost of water distribution system including capital,operational,and maintenance cost is mostly concerned issue by the utilities all the time;on the other hand improving the performance of water distribution systems is of equivalent importance,which is often conflicting with the previous goal.Many performance metrics of water networks are developed in recent years,including total or maximum pressure deficit,resilience,inequity,probabilistic robustness,and risk measure.In this paper,a new resilience metric based on the energy analysis of water distribution systems is proposed.Two optimization objectives are comprised of capital cost and the new resilience index.A heuristic algorithm,speedconstrained multi-objective particle swarm optimization( SMPSO) extended on the basis of the multi-objective particle swarm algorithm,is introduced to compare with another state-of-the-art heuristic algorithm,NSGA-II.The solutions are evaluated by two metrics,namely spread and hypervolume.To illustrate the capability of SMPSO to efficiently identify good designs,two benchmark problems( two-loop network and Hanoi network) are employed.From several aspects the results demonstrate that SMPSO is a competitive and potential tool to tackle with the optimization problem of complex systems.展开更多
Systems that have big transmission line may have problem on changes of pressure in the distribution system. Because pressure rate changes have been too much between water treatment plant and dead ends in distribution ...Systems that have big transmission line may have problem on changes of pressure in the distribution system. Because pressure rate changes have been too much between water treatment plant and dead ends in distribution system. This study is to analyze the effects pressure changes on the water quality in water distribution systems. It is located in south west of Ahwaz in IRAN. Ahwaz has five water treatment plants. In Ahwaz, two methods will be utilized. In the first method, samples will be taken from different locations in other to examine the quality of water in the distribution systems and the other method involves the use of simulation of models EPANET. Based on the EPANET model analysis of the water distribution system of Ahwaz as shown in result above the systems has large transmission line and exten- sive networks. So, the distance travelled and residence times have been causing to increase bacterial growth (HPC), chlorine consumption and hydraulic change (pressure) in water distribution system in Ahwaz. Pressure has a reversed relationship with bacterial growth (HPC) and Pressure has a direct relationship with residual chlorine. Pressure change has been causing to increase chlorine consumption more. So, Kw hasn’t any relationship with pressure and bacterial growth (HPC). The result of pressure changes among others can decrease in chlorine content and hydraulic factors, because the systems may be extensive and thus possess complex networks and hangs in quantity cause pressure of flow. Hence hydraulic changes (pressure) could affect of water quality in the water distribution system.展开更多
After the declaration of the first case of Legionnaire's disease in Cameroon in 2007, the Centre Pasteur of Cameroon implemented the detection method for Legionella. The introduction of this new method was put in pla...After the declaration of the first case of Legionnaire's disease in Cameroon in 2007, the Centre Pasteur of Cameroon implemented the detection method for Legionella. The introduction of this new method was put in places in order to investigate Legionella spp. colonization of water distribution systems (WDS) of large buildings including hospitals, hotels and Off Shore Exploitations Sites (OSES) in an attempt to identify risk factors for Legionella spp. Water systems of 6 hotels, 6 hospitals and 6 ships were investigated for the presence of Legionella spp.. A total of 130 samples were collected, 77 from hotels, 27 from hospitals and 26 from ships. 51 Legionella spp. were isolated from 41 (31.54%) water samples. Of a total of 51 positive isolates, 40/51 (78.4%) were L. pneumophila with 21 (52.5%) Legionellapneumophila serogroup (sg) 1, 16 (40%) L. pneumophila sg 5, 2 (5%) L. pneumophila sg 6, 1 (2.5%) L. pneumophila sg 7 and 11/51 Legionella spp. with 10 (90%) L. anisa, 1 (10%) Legionella dumoffii. 5 L. pneumophila sg 1 were associated with 5 L. pneumophila sg 5 and 4 L. pneumophila sg 1 were associated with 4 L. anisa. These results showed that WDS of hospitals, hotels and ships can be heavily colonized by Legionella spp. and may present a risk of Legionnaires' disease. Based on these preliminary results, we have just put in place a Legionella survey protocol in Cameroon.展开更多
Data obtained from a comprehensive multidisciplinary oceanographic survey in the central and northern parts of the Taiwan Strait, 24°20′-26°00′N, 118°45°-121°00′E by the Fujian Institute of...Data obtained from a comprehensive multidisciplinary oceanographic survey in the central and northern parts of the Taiwan Strait, 24°20′-26°00′N, 118°45°-121°00′E by the Fujian Institute of Oceanology during the period May, 1983 through May, 1984, showed that the distributions of dissolved oxygen (DO), nitrate, dissolved inorganic phosphate and silicate concentrations here had obvious areal and seasonal characteristics that were mainly influenced by the seasonal circulation ofthree major water systems in the Taiwan Strait-- the Taiwan Strait Warm Water (TSWW), theZhejiang-Fujian Coastal Water (ZFCW), and the Northeastern Strait Warm Water (NESWW).展开更多
Water quality within water distribution system may vary with both location and time. Water quality models are used to predict the spatial and temporal variation of water quality throughout water system. A model of res...Water quality within water distribution system may vary with both location and time. Water quality models are used to predict the spatial and temporal variation of water quality throughout water system. A model of residual chlorine decay in water pipe has been developed, given the consumption of chlorine in reactions with chemicals in bulk water, bio films on pipe wall, in corrosion process, and the mass transport of chlorine from bulk water to pipe wall. Analytical methods of the flow path from water sources to the observed point and the water age of every observed node were proposed. Model is used to predict the decay of residual chlorine in an actual distribution system. Good agreement between calculated and measured values was obtained.展开更多
As one of the most important urban lifeline systems,a water distribution system can be damaged under a strong earthquake,and the damage cannot easily be located,especially immediately after the event.This often causes...As one of the most important urban lifeline systems,a water distribution system can be damaged under a strong earthquake,and the damage cannot easily be located,especially immediately after the event.This often causes tremendous difficulties to post-earthquake emergency response and recovery activities.This paper proposes a methodology to locate seismic damage to a water distribution system by monitoring water head online at some nodes in the water distribution system.An artificial neural network-based inverse analysis method is developed to estimate the water head variations at all nodes that are not monitored based on the water head variations at the nodes that are monitored.The methodology provides a quick,effective,and practical way to locate seismic damage to a water distribution system.展开更多
A northern living strict water network was employed to investigate interaction among biological stability and classical water quality indexes. Key water quality indexes on water quality were determined by the static t...A northern living strict water network was employed to investigate interaction among biological stability and classical water quality indexes. Key water quality indexes on water quality were determined by the static test,then the correlations between biological stability and traditional water quality parameters were analyzed. Traditional water quality parameters and limited factors on bacteria were measured in summer and winter respectively. The results show that BDOC concentration change differently in summer and winter.Among classical parameters turbidity has a positive relation with BDOC but pH has a negative relation with BDOC. Total bacteria number shows a positive correlation with BDOC in the water distribution system.Residual chlorine shows a negative relation with total bacteria number. Fe content increasing will induce turbidity rising in water. To guarantee water safety,BDOC and chlorine content control must be incorporated together to restrict bacteria regrowth.展开更多
Within the biofilm and scales Legionella is less far susceptible to the effects of the most frequently used biocides. The objective of this study was to evaluate the effect of a 4-months continuous injection of a gas ...Within the biofilm and scales Legionella is less far susceptible to the effects of the most frequently used biocides. The objective of this study was to evaluate the effect of a 4-months continuous injection of a gas mixture (CO2 and inert gas) in the hot water distribution system of a large hotel colonized by L. pneumophila sg3 on limiting biofilm formation and scales and in turn Legionella growth. Before the continuous injection of the gas mixture, out of the 15 sampling points examined every month 60% were colonized by Legionella (mean concentrations of 102 cfu/L in the boilers and the return loop, and 104 cfu/L in taps and showers). One week after the injection of the gas mixture and daily fluxing of the distal outlets, the level of colonization decreased (3 cfu/L). When it was decided to flux all the distal outlets only 1 day per week the mean concentration of Legionella increased again (>104 cfu/L) in all the sampling points. Thus, cleaning of the boilers was performed and distal outlets were again fluxed daily. One week after the level of contamination decreased again (2 cfu/L). Nonetheless, the colonization was not eliminated and when fluxing of the distal outlets was not performed every day the mean concentrations of Legionella raised up to >104 cfu/L. Results indicate that the gas mixture was able to reduce the level of colonization by Legionella only because associated to the fluxing of the distal outlets.展开更多
Water Distribution Systems (WDSs) design and operation are usually done on a case-by-case basis. Numerous models have been proposed in the literature to solve specific problems in this field. The implementation of the...Water Distribution Systems (WDSs) design and operation are usually done on a case-by-case basis. Numerous models have been proposed in the literature to solve specific problems in this field. The implementation of these models to any real-world WDS optimization problem is left to the discretion of designers who lack the necessary tools that will guide them in the decision-making process for a given WDS design project. Practitioners are not always very familiar with optimization applied to water network design. This results in a quasi-exclusive use of engineering judgment when dealing with this issue. In order to support a decision process in this field, the present article suggests a step-by-step approach to solve the multi-objective design problem by using both engineering and optimization. A genetic algorithm is proposed as the optimization tool and the targeted objectives are: 1) to minimize the total cost (capital and operation), 2) to minimize the residence time of the water within the system and 3) to maximize a network reliability metric. The results of the case study show that preliminary analysis can significantly reduce decision variables and computational burden. Therefore, the approach will help network design practitioners to reduce optimization problems to a more manageable size.展开更多
The quality of water in water distribution system may vary with both location and time. Water quality models were used to predict spatial and temporal variation of water quality throughout the water system. Before ana...The quality of water in water distribution system may vary with both location and time. Water quality models were used to predict spatial and temporal variation of water quality throughout the water system. Before analyzing the variations of water quality, it is necessary to determine the hydrodynamics in water distribution system. Analytical methods for the flow path from water sources to the observed point and water age of every observed node are proposed. This paper makes a further study on water supply route of multi-sources water supply network system. These studies have been applied to an actual water distribution system.展开更多
Pipes serving for water distribution system for different years in northern city,were chosen as objectives for study.The shape and component of corrosion scales were measured,and formation mechanism of corrosion was a...Pipes serving for water distribution system for different years in northern city,were chosen as objectives for study.The shape and component of corrosion scales were measured,and formation mechanism of corrosion was also analyzed.The corrosion mechanism of pipes was studied on the sides of electrochemistry and microbe.The solution to eliminate corrosion scales in water distribution system was also proposed.The results show that the specific surface areas of five corrosion scales are between 41.35 and 132.3 m2/g and the dimension of corrosion scales enlarge with the increase of serving age,which could induce the decrease of water flow cross-section.展开更多
To investigate the characteristics of disinfection by-products (DBPs) in an actual water distribution system using the raw water with high bromide ion concentration, the composition and concentration of trihalometha...To investigate the characteristics of disinfection by-products (DBPs) in an actual water distribution system using the raw water with high bromide ion concentration, the composition and concentration of trihalomethanes (THMs) formed by chlorination of the water in the presence of bromide ion were measured in a city water distribution system during one year. The results show that brominated THMs contributed a great part (83%-89% ) to the index for additive toxicity (ATI) and resulted in the ATI of most of the samples exceeding WHO guideline standard for total THMs ( TTHMs), especially during the summer ( rainy season). This indicates that the chlorination of water in the presence of bromide ion leaded to high ratios of brominated THMs to TrHMs. However, a visible increase in the concentration of THMs with increasing residence time in the distribution system was not observed. Additionally, based on alternatives analysis, packed tower aeration method is proposed to reduce THMs level of the finished water leaving the treatment plant.展开更多
To analyze the factors affecting the leakage rate of water distribution system, we built a macroscopic "leakage rate–leakage factors"(LRLF) model. In this model, we consider the pipe attributes(quality, dia...To analyze the factors affecting the leakage rate of water distribution system, we built a macroscopic "leakage rate–leakage factors"(LRLF) model. In this model, we consider the pipe attributes(quality, diameter,age), maintenance cost, valve replacement cost, and annual average pressure. Based on variable selection and principal component analysis results, we extracted three main principle components—the pipe attribute principal component(PAPC), operation management principal component, and water pressure principal component. Of these, we found PAPC to have the most influence. Using principal component regression, we established an LRLF model with no detectable serial correlations. The adjusted R2 and RMSE values of the model were 0.717 and 2.067, respectively.This model represents a potentially useful tool for controlling leakage rate from the macroscopic viewpoint.展开更多
文摘A field study on the estimation and analysis of iron stability in drinking water distribution system was carried out in a city of China. The stability of iron ion was estimated by pC-pH figure. It was found that iron ion was unstable, with a high Fe (OH)3 precipitation tendency and obvious increase in turbidity. The outer layer of the corrosion scale was compact, while the inner core was porous. The main composition of the scale was iron, and the possible compound constitutes of the outer scale were α-FeOH, γ-FeOOH, α-Fe2O3, γ-F2O3, FeCl3, while the inner were Fe3O4, FeCl2, FeCO3. According to the characteristics of the corrosion scale, it was thought that the main reason for iron instability was iron release from corrosion scale. Many factors such as pipe materials, dissolved oxygen and chlorine residual affect iron release. Generally, higher iron release occurred with lower dissolved oxygen or chlorine residual concentration, while lower iron release occurred with higher dissolved oxygen or chlorine residual concentration. The reason was considered that the passivated out layer of scale of ferric oxide was broken down by reductive reaction in a condition of low oxidants concentration, which would result more rapid corrosion of the nine and red water phenomenon.
基金Supported by National Natural Science Foundation of China (No.50478086)Tianjin Special Scientific Innovation Foundation (No.06FZZDSH00900)
文摘The water distribution system of one residential district in Tianjin is taken as an example to analyze the changes of water quality.Partial least squares(PLS) regression model,in which the turbidity and Fe are regarded as control objectives,is used to establish the statistical model.The experimental results indicate that the PLS regression model has good predicted results of water quality compared with the monitored data.The percentages of absolute relative error(below 15%,20%,30%) are 44.4%,66.7%,100%(turbidity) and 33.3%,44.4%,77.8%(Fe) on the 4th sampling point;77.8%,88.9%,88.9%(turbidity) and 44.4%,55.6%,66.7%(Fe) on the 5th sampling point.
文摘Water leaving the treatment works is usually of a high quality but its properties change during the transportation stage. Increasing awareness of the quality of the service provided within the water industry today and assessing the reliability of the water quality in a distribution system has become a major significance for decision on system operation based on water quality in distribution networks. Using together a water age model, a chlorine decay model and a model of acceptable maximum water age can assess the reliability of the water quality in a distribution system. First, the nodal water age values in a certain complex distribution system can be calculated by the water age model. Then, the acceptable maximum water age value in the distribution system is obtained based on the chlorine decay model. The nodes at which the water age values are below the maximum value are regarded as reliable nodes. Finally, the reliability index on the percentile weighted by the nodal demands reflects the reliability of the water quality in the distribution system. The approach has been applied in a real water distribution network. The contour plot based on the water age values determines a surface of the reliability of the water quality. At any time, this surface is used to locate high water age but poor reliability areas, which identify parts of the network that may be of poor water quality. As a result, the contour water age provides a valuable aid for a straight insight into the water quality in the distribution system.
基金Supported by National Natural Science Foundation of China (No. 50278062 and 50578108)Science and Technology Innovation Funds Project of Tianjin, China (No. 08FDZDSF03200)
文摘A leak detection method based on Bayesian theory and Fisher’s law was developed for water distribution systems. A hydraulic model was associated with the parameters of leaks (location, extent). The randomness of parameter values was quantified by probability density function and updated by Bayesian theory. Values of the parameters were estimated based on Fisher’s law. The amount of leaks was estimated by back propagation neural network. Based on flow characteristics in water distribution systems, the location of leaks can be estimated. The effectiveness of the proposed method was illustrated by simulated leak data of node pressure head and flow rate of pipelines in a test pipe network, and the leaks were spotted accurately and renovated on time.
基金Sponsored by Fok Ying Tung Education Foundation (No. 94004)
文摘A combined first and second-order model, which includes bulk decay and wall decay, was developed to describe chlorine decay in water distribution systems. In the model the bulk decay has complex relationships with total organic carbon (TOC), the initial chlorine concentration and the temperature. Except for the initial stages they can be simplified into a linear increase with TOC, a linear decrease with initial chlorine concentration and an exponential relationship with the temperature. The model also explains why chlorine decays rapidly in the initial stages. The parameters of model are determined by deriving the best fitness with experimental data. And the accuracy of model has been verified by using the experimental data and the monitoring data in a distribution system.
基金Sponsored by the Project of Application Technology Research and Development Plan in Heilongjiang Province(Grant No.GA13C302)
文摘In order to compare two advanced multi-objective evolutionary algorithms,a multi-objective water distribution problem is formulated in this paper.The multi-objective optimization has received more attention in the water distribution system design.On the one hand the cost of water distribution system including capital,operational,and maintenance cost is mostly concerned issue by the utilities all the time;on the other hand improving the performance of water distribution systems is of equivalent importance,which is often conflicting with the previous goal.Many performance metrics of water networks are developed in recent years,including total or maximum pressure deficit,resilience,inequity,probabilistic robustness,and risk measure.In this paper,a new resilience metric based on the energy analysis of water distribution systems is proposed.Two optimization objectives are comprised of capital cost and the new resilience index.A heuristic algorithm,speedconstrained multi-objective particle swarm optimization( SMPSO) extended on the basis of the multi-objective particle swarm algorithm,is introduced to compare with another state-of-the-art heuristic algorithm,NSGA-II.The solutions are evaluated by two metrics,namely spread and hypervolume.To illustrate the capability of SMPSO to efficiently identify good designs,two benchmark problems( two-loop network and Hanoi network) are employed.From several aspects the results demonstrate that SMPSO is a competitive and potential tool to tackle with the optimization problem of complex systems.
文摘Systems that have big transmission line may have problem on changes of pressure in the distribution system. Because pressure rate changes have been too much between water treatment plant and dead ends in distribution system. This study is to analyze the effects pressure changes on the water quality in water distribution systems. It is located in south west of Ahwaz in IRAN. Ahwaz has five water treatment plants. In Ahwaz, two methods will be utilized. In the first method, samples will be taken from different locations in other to examine the quality of water in the distribution systems and the other method involves the use of simulation of models EPANET. Based on the EPANET model analysis of the water distribution system of Ahwaz as shown in result above the systems has large transmission line and exten- sive networks. So, the distance travelled and residence times have been causing to increase bacterial growth (HPC), chlorine consumption and hydraulic change (pressure) in water distribution system in Ahwaz. Pressure has a reversed relationship with bacterial growth (HPC) and Pressure has a direct relationship with residual chlorine. Pressure change has been causing to increase chlorine consumption more. So, Kw hasn’t any relationship with pressure and bacterial growth (HPC). The result of pressure changes among others can decrease in chlorine content and hydraulic factors, because the systems may be extensive and thus possess complex networks and hangs in quantity cause pressure of flow. Hence hydraulic changes (pressure) could affect of water quality in the water distribution system.
文摘After the declaration of the first case of Legionnaire's disease in Cameroon in 2007, the Centre Pasteur of Cameroon implemented the detection method for Legionella. The introduction of this new method was put in places in order to investigate Legionella spp. colonization of water distribution systems (WDS) of large buildings including hospitals, hotels and Off Shore Exploitations Sites (OSES) in an attempt to identify risk factors for Legionella spp. Water systems of 6 hotels, 6 hospitals and 6 ships were investigated for the presence of Legionella spp.. A total of 130 samples were collected, 77 from hotels, 27 from hospitals and 26 from ships. 51 Legionella spp. were isolated from 41 (31.54%) water samples. Of a total of 51 positive isolates, 40/51 (78.4%) were L. pneumophila with 21 (52.5%) Legionellapneumophila serogroup (sg) 1, 16 (40%) L. pneumophila sg 5, 2 (5%) L. pneumophila sg 6, 1 (2.5%) L. pneumophila sg 7 and 11/51 Legionella spp. with 10 (90%) L. anisa, 1 (10%) Legionella dumoffii. 5 L. pneumophila sg 1 were associated with 5 L. pneumophila sg 5 and 4 L. pneumophila sg 1 were associated with 4 L. anisa. These results showed that WDS of hospitals, hotels and ships can be heavily colonized by Legionella spp. and may present a risk of Legionnaires' disease. Based on these preliminary results, we have just put in place a Legionella survey protocol in Cameroon.
文摘Data obtained from a comprehensive multidisciplinary oceanographic survey in the central and northern parts of the Taiwan Strait, 24°20′-26°00′N, 118°45°-121°00′E by the Fujian Institute of Oceanology during the period May, 1983 through May, 1984, showed that the distributions of dissolved oxygen (DO), nitrate, dissolved inorganic phosphate and silicate concentrations here had obvious areal and seasonal characteristics that were mainly influenced by the seasonal circulation ofthree major water systems in the Taiwan Strait-- the Taiwan Strait Warm Water (TSWW), theZhejiang-Fujian Coastal Water (ZFCW), and the Northeastern Strait Warm Water (NESWW).
基金TheNationalNaturalScienceFoundationofChina (No .5 96 780 18)
文摘Water quality within water distribution system may vary with both location and time. Water quality models are used to predict the spatial and temporal variation of water quality throughout water system. A model of residual chlorine decay in water pipe has been developed, given the consumption of chlorine in reactions with chemicals in bulk water, bio films on pipe wall, in corrosion process, and the mass transport of chlorine from bulk water to pipe wall. Analytical methods of the flow path from water sources to the observed point and the water age of every observed node were proposed. Model is used to predict the decay of residual chlorine in an actual distribution system. Good agreement between calculated and measured values was obtained.
基金National Natural Science Foundation of China under Grant No.59878032
文摘As one of the most important urban lifeline systems,a water distribution system can be damaged under a strong earthquake,and the damage cannot easily be located,especially immediately after the event.This often causes tremendous difficulties to post-earthquake emergency response and recovery activities.This paper proposes a methodology to locate seismic damage to a water distribution system by monitoring water head online at some nodes in the water distribution system.An artificial neural network-based inverse analysis method is developed to estimate the water head variations at all nodes that are not monitored based on the water head variations at the nodes that are monitored.The methodology provides a quick,effective,and practical way to locate seismic damage to a water distribution system.
基金Sponsored by Natural Science Foundation of Shandong Province(Grant No.ZR2014EL033)
文摘A northern living strict water network was employed to investigate interaction among biological stability and classical water quality indexes. Key water quality indexes on water quality were determined by the static test,then the correlations between biological stability and traditional water quality parameters were analyzed. Traditional water quality parameters and limited factors on bacteria were measured in summer and winter respectively. The results show that BDOC concentration change differently in summer and winter.Among classical parameters turbidity has a positive relation with BDOC but pH has a negative relation with BDOC. Total bacteria number shows a positive correlation with BDOC in the water distribution system.Residual chlorine shows a negative relation with total bacteria number. Fe content increasing will induce turbidity rising in water. To guarantee water safety,BDOC and chlorine content control must be incorporated together to restrict bacteria regrowth.
文摘Within the biofilm and scales Legionella is less far susceptible to the effects of the most frequently used biocides. The objective of this study was to evaluate the effect of a 4-months continuous injection of a gas mixture (CO2 and inert gas) in the hot water distribution system of a large hotel colonized by L. pneumophila sg3 on limiting biofilm formation and scales and in turn Legionella growth. Before the continuous injection of the gas mixture, out of the 15 sampling points examined every month 60% were colonized by Legionella (mean concentrations of 102 cfu/L in the boilers and the return loop, and 104 cfu/L in taps and showers). One week after the injection of the gas mixture and daily fluxing of the distal outlets, the level of colonization decreased (3 cfu/L). When it was decided to flux all the distal outlets only 1 day per week the mean concentration of Legionella increased again (>104 cfu/L) in all the sampling points. Thus, cleaning of the boilers was performed and distal outlets were again fluxed daily. One week after the level of contamination decreased again (2 cfu/L). Nonetheless, the colonization was not eliminated and when fluxing of the distal outlets was not performed every day the mean concentrations of Legionella raised up to >104 cfu/L. Results indicate that the gas mixture was able to reduce the level of colonization by Legionella only because associated to the fluxing of the distal outlets.
文摘Water Distribution Systems (WDSs) design and operation are usually done on a case-by-case basis. Numerous models have been proposed in the literature to solve specific problems in this field. The implementation of these models to any real-world WDS optimization problem is left to the discretion of designers who lack the necessary tools that will guide them in the decision-making process for a given WDS design project. Practitioners are not always very familiar with optimization applied to water network design. This results in a quasi-exclusive use of engineering judgment when dealing with this issue. In order to support a decision process in this field, the present article suggests a step-by-step approach to solve the multi-objective design problem by using both engineering and optimization. A genetic algorithm is proposed as the optimization tool and the targeted objectives are: 1) to minimize the total cost (capital and operation), 2) to minimize the residence time of the water within the system and 3) to maximize a network reliability metric. The results of the case study show that preliminary analysis can significantly reduce decision variables and computational burden. Therefore, the approach will help network design practitioners to reduce optimization problems to a more manageable size.
文摘The quality of water in water distribution system may vary with both location and time. Water quality models were used to predict spatial and temporal variation of water quality throughout the water system. Before analyzing the variations of water quality, it is necessary to determine the hydrodynamics in water distribution system. Analytical methods for the flow path from water sources to the observed point and water age of every observed node are proposed. This paper makes a further study on water supply route of multi-sources water supply network system. These studies have been applied to an actual water distribution system.
基金Sponsored by the National High Technology Research and Development Program of China(Grant No.2007AA06Z303)the Science Foundation of Harbin(Grant No.2007RFXXS022)+1 种基金Samdong Province High School Science&Technology Foundation Planning Project(Grant No.J10LE10)the Foundation of Jinan University(Grant No.XBS1014)
文摘Pipes serving for water distribution system for different years in northern city,were chosen as objectives for study.The shape and component of corrosion scales were measured,and formation mechanism of corrosion was also analyzed.The corrosion mechanism of pipes was studied on the sides of electrochemistry and microbe.The solution to eliminate corrosion scales in water distribution system was also proposed.The results show that the specific surface areas of five corrosion scales are between 41.35 and 132.3 m2/g and the dimension of corrosion scales enlarge with the increase of serving age,which could induce the decrease of water flow cross-section.
基金National High-Tech Research and Development Program of China ( 863 Program ) ( No.2007AA06Z303)
文摘To investigate the characteristics of disinfection by-products (DBPs) in an actual water distribution system using the raw water with high bromide ion concentration, the composition and concentration of trihalomethanes (THMs) formed by chlorination of the water in the presence of bromide ion were measured in a city water distribution system during one year. The results show that brominated THMs contributed a great part (83%-89% ) to the index for additive toxicity (ATI) and resulted in the ATI of most of the samples exceeding WHO guideline standard for total THMs ( TTHMs), especially during the summer ( rainy season). This indicates that the chlorination of water in the presence of bromide ion leaded to high ratios of brominated THMs to TrHMs. However, a visible increase in the concentration of THMs with increasing residence time in the distribution system was not observed. Additionally, based on alternatives analysis, packed tower aeration method is proposed to reduce THMs level of the finished water leaving the treatment plant.
基金supported by the Ministry of Science and Technology of China (No.2014ZX07203-009)the Fundamental Research Funds for the Central Universitiesthe Program for New Century Excellent Talents at the University of China
文摘To analyze the factors affecting the leakage rate of water distribution system, we built a macroscopic "leakage rate–leakage factors"(LRLF) model. In this model, we consider the pipe attributes(quality, diameter,age), maintenance cost, valve replacement cost, and annual average pressure. Based on variable selection and principal component analysis results, we extracted three main principle components—the pipe attribute principal component(PAPC), operation management principal component, and water pressure principal component. Of these, we found PAPC to have the most influence. Using principal component regression, we established an LRLF model with no detectable serial correlations. The adjusted R2 and RMSE values of the model were 0.717 and 2.067, respectively.This model represents a potentially useful tool for controlling leakage rate from the macroscopic viewpoint.