期刊文献+
共找到136篇文章
< 1 2 7 >
每页显示 20 50 100
Optimal operation of water supply systems with tanks based on genetic algorithm 被引量:6
1
作者 俞亭超 张土乔 李洵 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2005年第8期886-893,共8页
In view of the poor water supply system’s network properties, the system’s complicated network hydraulic equations were replaced by macroscopic nodal pressure model and the model of relationship between supply flow ... In view of the poor water supply system’s network properties, the system’s complicated network hydraulic equations were replaced by macroscopic nodal pressure model and the model of relationship between supply flow and water source head. By using pump-station pressure head and initial tank water levels as decision variables, the model of optimal allocation of water supply between pump-sources was developed. Genetic algorithm was introduced to deal with the model of optimal allocation of water supply. Methods for handling each constraint condition were put forward, and overcome the shortcoming such as premature convergence of genetic algorithm; a solving method was brought forward in which genetic algorithm was combined with simulated annealing technology and self-adaptive crossover and mutation probabilities were adopted. An application example showed the feasibility of this algorithm. 展开更多
关键词 water supply system Optimal operation Genetic algorithm TANK
下载PDF
Evaluation and optimization of secondary water supply system renovation 被引量:5
2
作者 TIAN Yi-mei SI Yan-jie +1 位作者 LI Hong WU Mi-fang 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2007年第9期1488-1494,共7页
Due to pollution in second water supply system (SWSS),nine renovation alternative plans were proposed and com-prehensive evaluations of different plan based on Analytical Hierarchy Process (AHP) were presented in this... Due to pollution in second water supply system (SWSS),nine renovation alternative plans were proposed and com-prehensive evaluations of different plan based on Analytical Hierarchy Process (AHP) were presented in this paper. Comparisons of advantages and disadvantages among the plans of SWSS renovations provided solid foundation for selecting the most appro-priate plan for engineering projects. In addition,a mathematical model of the optimal combination of renovation plans has been set up and software Lingo was used to solve the model. As a case study,the paper analyzed 15 buildings in Tianjin City. After simulation of the SWSS renovation system,an optimal scheme was obtained,the result of which indicates that 10 out of those 15 buildings need be renovated in priority. The renovation plans selected for each building are the ones ranked higher in the com-prehensive analysis. The analysis revealed that the optimal scheme,compared with two other randomly calculated ones,increased the percentage of service population by 19.6% and 13.6% respectively,which significantly improved social and economical benefits. 展开更多
关键词 Secondary water supply system (SWSS) Renovation plan Analytical Hierarchy Process (AHP) Hierarchical model OPTIMIZATION
下载PDF
Optimal Dispatching of Large-scale Water Supply System 被引量:3
3
作者 吕谋 SONG Shuang +1 位作者 Zhao Hongbin ZHANG Tuqiao 《High Technology Letters》 EI CAS 2003年第2期21-26,共6页
This paper deals with the use of optimal control techniques in large-scale water distribution networks. According to the network characteristics and actual state of the water supply system in China, the implicit model... This paper deals with the use of optimal control techniques in large-scale water distribution networks. According to the network characteristics and actual state of the water supply system in China, the implicit model, which may be solved by utilizing the hierarchical optimization method, is established. In special, based on the analyses of the water supply system containing variable-speed pumps, a software tool has been developed successfully. The application of this model to the city of Shenyang (China) is compared to experiential strategy. The results of this study show that the developed model is a very promising optimization method to control the large-scale water supply systems. 展开更多
关键词 optimal dispatching water supply system water networks implicit model hierarchical optimization
下载PDF
Method of Distinguishing Hydrologic Drought for Water Supply System 被引量:2
4
作者 冯平 韩松 李绍飞 《Transactions of Tianjin University》 EI CAS 2005年第5期371-375,共5页
It is very common to design water supply system to adjust runoff. Thus it will not meet the practical needs if only the hydrologic drought in natural basin is studied. In practice the natural water balance and water d... It is very common to design water supply system to adjust runoff. Thus it will not meet the practical needs if only the hydrologic drought in natural basin is studied. In practice the natural water balance and water deficits must be researched, i. e. . the adjusting effects of the water supply sys- tem such as a reservoir should be considered, and the drought event be distinguished according to the special system. The problem of drought identification under adjusted runoff was investigated in this study. By considering water transfer during different periods, a method to distinguish hydrologic drought for the water supply system was developed, and a standard drought severity index SWDSI was proposed. The method has been applied in Pan Jiakou water supply system in China. From 1953 to 1997,a total of 14 hydrologic droughts were identified in the water supply system, among which there were 3 severe droughts, 6 moderate droughts and 5 light droughts. The results are in good agreement with the historic drought records. 展开更多
关键词 DROUGHT water supply system - SWDSI drought identification RUNOFF
下载PDF
Geostatistical Studies of Space-Temporal Variation in Selected Quality Parameters in Klodzko Water Supply System (SW Part of Poland)
5
作者 Barbara Namyslowska-Wilczyfiska 《Journal of Geological Resource and Engineering》 2015年第2期57-81,共25页
Selected results of research connected with the development of a (3D) geostatistical hydrogeocbemical model of the Klodzko city area, dedicated to the spatial and time variation in the quality parameters in the Klod... Selected results of research connected with the development of a (3D) geostatistical hydrogeocbemical model of the Klodzko city area, dedicated to the spatial and time variation in the quality parameters in the Klodzko water supply system (SW part of Poland) have been presented. The research covers the period 2007-2011. Spatial analyses of the variation in three quality parameters, i.e. Fe iron (g/m3) content, Mn manganese (g/m3) content and NI-I4+ ammonium ion (g/m3) content, were carried out. Spatial and time variation in the parameters was analyzed on the basis of the data (2007-2011). The input for the studies was the chemical determinations of the quality parameters of water samples taken in the Klodzko water supply system area (also treated water) in different periods of time. These data were subjected to spatial analyses using geostatistical methods. The parameters of the assumed theoretical models of directional semivariograms functions of the studied regionalized variables, were used in the ordinary (block) kriging estimation. Generally, the behaviour of the quality parameters in the Klodzko water supply system has been found to vary in space and time. Thanks to the multivariate spatial analyses some regularities in the variation in the water supply system in the Klodzko city area have been identified. In the considered time interval, the shapes of the directional Fe iron content semivariogram show a tendency to vary periodically. The courses of the directional semivariograms of Mn manganese content and NI-I4+ ammonium ion content show some tendencies towards directional variation over the passing years. There are visible distinct increasing trends of variability for Mn content and stronger variation are observed for NH4+ ion content. The kriging estimation results were used to determine the levels of elevated values 2* of the water quality parameters in the years 2007-2011 and to forecast these values for the years 2012-2014. The maximum values Z* of the quality parameters were stated for the years: 2007, 2008-2009 and 2012 (the decreasing trend in Fe iron content averages Z* variation towards the year 2012, the increasing trend in Mn content averages Z* variation towards the year 2012 and the increasing trend in NH4+ ion content averages Z* variation towards the years 2008-2009 and then the decreasing trend towards the year 2012). 展开更多
关键词 Treated water water supply system quality parameters spatio-temporal variation GEOSTATISTICS directional semivariogram ordinary kriging.
下载PDF
Energy efficiency performance of multi-energy district heating and hot water supply system 被引量:2
6
作者 金楠 赵靖 朱能 《Journal of Central South University》 SCIE EI CAS 2012年第5期1377-1382,共6页
A district heating and hot water supply system is presented which synthetically utilizes geothermal energy,solar thermal energy and natural gas thermal energy.The multi-energy utilization system has been set at the ne... A district heating and hot water supply system is presented which synthetically utilizes geothermal energy,solar thermal energy and natural gas thermal energy.The multi-energy utilization system has been set at the new campus of Tianjin Polytechnic University(TPU),A couple of deep geothermal wells which are 2 300 m in depth were dug,Deep geothermal energy cascade utilization is achieved by two stages of plate heat exchangers(PHE) and two stages of water source heat pumps(WSHP).Shallow geothermal energy is used in assistant heating by two ground coupled heat pumps(GCHPs) with 580 vertical ground wells which are 120 m in depth.Solar thermal energy collected by vacuum tube arrays(VTAs) and geothermal energy are complementarily utilized to make domestic hot water.Superfluous solar energy can be stored in shallow soil for the GCHP utilization.The system can use fossil fuel thermal energy by two natural gas boilers(NGB) to assist in heating and making hot water.The heating energy efficiency was measured in the winter of 2010-2011.The coefficients of performance(COP) under different heating conditions are discussed.The performance of hot water production is tested in a local typical winter day and the solar thermal energy utilization factor is presented.The rusults show that the average system COP is 5.75 or 4.96 under different working conditions,and the typical solar energy utilization factor is 0.324. 展开更多
关键词 geothermal energy solar thermal energy district heating hot water supply
下载PDF
Energy efficiency in a water supply system:Energy consumption and CO_2 emission
7
作者 Helena M.RAMOS Filipe VIEIRA Dídia I.C.COVAS 《Water Science and Engineering》 EI CAS 2010年第3期331-340,共10页
This paper presents important fundamentals associated with water and energy efficiency and highlights the importance of using renewable energy sources. A model of multi-criteria optimization for energy efficiency base... This paper presents important fundamentals associated with water and energy efficiency and highlights the importance of using renewable energy sources. A model of multi-criteria optimization for energy efficiency based on water and environmental management policies, including the preservation of water resources and the control of water pressure and energy consumption through a hybrid energy solution, was developed and applied to a water supply system. The methodology developed includes three solutions: (1) the use of a water turbine in pipe systems where pressures are higher than necessary and pressure-reducing valves are installed, (2) the optimization of pumping operation according to the electricity tariff and water demand, and (3) the use of other renewable energy sources, including a wind turbine, to supply energy to the pumping station, with the remaining energy being sold to the national electric grid. The use of an integrated solution (water and energy-) proves to be a valuable input for creating benefits from available hydro energy in the water supply system in order to produce clean power, and the use of a wind source allows for the reduction of energy consumption in pumping stations, as well as of the CO2 emission to the atmosphere. 展开更多
关键词 multi-criteria optimization energy efficiency water supply renewable energy sources CO2 emission
下载PDF
Households' Assessment of the Water Quality and Services of Multi-model Urban Water Supply System in the Informal Settlements of Dar es Salaam, Tanzania
8
作者 Francis Dakyaga Alphonce G. Kyessi Joel M. Msami 《Journal of Civil Engineering and Architecture》 2018年第5期362-381,共20页
In the global south wide range of studies highlight the limitations of the single-modelled public urban water system to meeting the endogenous water preferences of the urban population. Studies also touched on the com... In the global south wide range of studies highlight the limitations of the single-modelled public urban water system to meeting the endogenous water preferences of the urban population. Studies also touched on the complementary roles of private water actors to the single-modelled public water supply system in the urban water supply network. Multiple of urban water supply systems (multi-model) co-exist in the urban landscape of global south. However, it is unclear and largely inconclusive on the suitable and satisfactory urban water supply model that meets the water consumption needs of informal settlement dwellers in the global south. This study draws the experiences of households in the informal settlements using a case-study with cross-sectional survey strategy to assess the suitability of the multi-model urban water supply system for sustainable urban water supply in the informal settlements. A total of 292 households were randomly sampled alongside 35 purposively sampled private water actors and public water departments. The data were collected through face to face interviews. Findings show that water supply services of the multi-model water supply system are inevitably suitable for the water consumption needs of informal settlements’s dwellers. The operation of the multi-model water supply system is flexible and able to accommodate the diverse water consumption preferences and choices of the different socio-economic groups in the informal settlements. We observed that multiplicity of urban water supply system increases households’ access to water but does not necessarily improve the quality of water serve in the informal settlements. The paper recommended for the formalisation and adoption of the multi-model urban water supply system to meet the growing demand for improved water supply and services in the informal settlements. 展开更多
关键词 water quality multi-model water supply informal settlements urban water supply urban poor.
下载PDF
Water Leakages in Public Water Supply System and How to Prevent Them
9
作者 Katarina Tothova Juraj Haluska 《Journal of Life Sciences》 2013年第6期668-676,共9页
The article addresses the results of effective water losses prevention in public water supply systems, focusing on procedures for monitoring hidden leaks as the main part of losses and as the first step to control and... The article addresses the results of effective water losses prevention in public water supply systems, focusing on procedures for monitoring hidden leaks as the main part of losses and as the first step to control and prevent them. The described methodology has been applied based on a cross-border cooperation between twin capital cities Vienna and Bratislava in the Central Europe Region within the project deWaloP (Developing Water Loss Prevention) and adopted in Bratislava Water Company (BVS) in the Slovak Republic. The paper provides a complex of simple and easily available practices for analyses of water distribution measurements bringing essential information as to the necessity to use advanced procedures to actively reduce leakage. These practices involve minimum night flows analyses, hydrodynamic pressures analyses, pinpointing of water leakages by working with valves in the water network, the methodology of setting alarm limits for measured data, as well as use of advanced practices to obtain missing topologic data. As the water infrastructure in former socialistic countries are in bad technical condition and the lack of pertinent operational data is a significant obstacle to the application of a more sophisticated methodology based on GIS and other information systems, the procedures focus on using the most simple way to evaluate and control water losses. Finally, the introduction of described methodology in Bratislava Water Company after many years of unsuccessful effort even with expensive sophisticated leakage equipment brought positive outputs and the graph line of water losses level is finally going down. The use of expensive multi-correlating equipment together with human resources on the basis of implementing the above described leakage monitoring will subsequently become more effective, as it shall pinpoint major leakages, disclosure and removal of that shall significantly contribute to the effective reduction of water losses. 展开更多
关键词 Drinking water supply water losses in public pipe system water leakages distribution measurements of water flow minimum night flow evaluation.
下载PDF
Drinking water quality & health risk assessment of secondary water supply systems in residential neighborhoods
10
作者 Yating Wei Dong Hu +3 位作者 Chengsong Ye Heng Zhang Haoran Li Xin Yu 《Frontiers of Environmental Science & Engineering》 SCIE EI CSCD 2024年第2期47-62,共16页
Secondary water supply systems(SWSSs)are important components of the water supply infrastructure that ensure residents’drinking water safety.SWSSs are characterized by long detention time,warm temperature,and unreaso... Secondary water supply systems(SWSSs)are important components of the water supply infrastructure that ensure residents’drinking water safety.SWSSs are characterized by long detention time,warm temperature,and unreasonable management,which may trigger the deterioration of water quality and increase risks.In this study,drinking water quality index(DWQI)and health risk assessment(HRA)were selected and modified to quantitatively assess the water quality and health risks of SWSSs in residential neighborhoods.In total,121 seasonal water samples were selected.It was observed that the water quality was excellent with the DWQI of 0.14±0.04,excluding one sample,which was extremely poor owing to its excessive total bacterial count.The HRA results revealed that the health risks were low:negligible non-carcinogenic risk for any population;negligible and acceptable carcinogenic risk for children aged 6–17 and adults.However,samples revealed higher carcinogenic risk(7.63×10−5±3.29×10−6)for children aged 0–5,and arsenic was the major substance.Summer samples had poor water quality and higher health risks,which called for attention.To further investigate the water quality and health risks of SWSSs,monthly sampling was conducted during summer.All 24 water samples were qualified in Chinese standard(GB 5749-2022)and characterized as excellent quality.Their HRA results were consistent with the seasonal samples’and the health risks were mainly concentrated in May.Overall,our study provides a suitable framework for water quality security,advice for managers,and references for administrators in other cities. 展开更多
关键词 Drinking water quality water quality index Health risk assessment Secondary water supply systems Heavy metals
原文传递
Analysis of faulting destruction and water supply pipeline damage from the first mainshock of the February 6,2023 Türkiye earthquake doublet 被引量:1
11
作者 Xiaoqing Fan Libao Zhang +2 位作者 Juke Wang Yefei Ren Aiwen Liu 《Earthquake Science》 2024年第1期78-90,共13页
In 2023,two consecutive earthquakes exceeding a magnitude of 7 occurred in Türkiye,causing severe casualties and economic losses.The damage to critical urban infrastructure and building structures,including highw... In 2023,two consecutive earthquakes exceeding a magnitude of 7 occurred in Türkiye,causing severe casualties and economic losses.The damage to critical urban infrastructure and building structures,including highways,railroads,and water supply pipelines,was particularly severe in areas where these structures intersected the seismogenic fault.Critical infrastructure projects that traverse active faults are susceptible to the influence of fault movement,pulse velocity,and ground motions.In this study,we used a unique approach to analyze the acceleration records obtained from the seismic station array(9 strong ground motion stations)located along the East Anatolian Fault(the seismogenic fault of the MW7.8 mainshock of the 2023 Türkiye earthquake doublet).The acceleration records were filtered and integrated to obtain the velocity and displacement time histories.We used the results of an on-site investigation,jointly conducted by China Earthquake Administration and Türkiye’s AFAD,to analyze the distribution of PGA,PGV,and PGD recorded by the strong motion array of the East Anatolian Fault.We found that the maximum horizontal PGA in this earthquake was 3.0 g,and the maximum co-seismic surface displacement caused by the East Anatolian Fault rupture was 6.50 m.As the fault rupture propagated southwest,the velocity pulse caused by the directional effect of the rupture increased gradually,with the maximum PGA reaching 162.3 cm/s.We also discussed the seismic safety of critical infrastructure projects traversing active faults,using two case studies of water supply pipelines in Türkiye that were damaged by earthquakes.We used a three-dimensional finite element model of the PE(polyethylene)water pipeline at the Islahiye State Hospital and fault displacement observations obtained through on-site investigation to analyze pipeline failure mechanisms.We further investigated the effect of the fault-crossing angle on seismic safety of a pipeline,based on our analysis and the failure performance of the large-diameter Thames Water pipeline during the 1999 Kocaeli earthquake.The seismic method of buried pipelines crossing the fault was summarized. 展开更多
关键词 Türkiye earthquake fault displacement near-fault ground motion velocity pulse water supply pipeline
下载PDF
Water hammer protection for diversion systems in front of pumps in long-distance water supply projects 被引量:4
12
作者 Lin Shi Jian Zhang +3 位作者 Xiao-dong Yu Sheng Chen Wen-long Zhao Xu-yun Chen 《Water Science and Engineering》 EI CAS CSCD 2023年第2期211-218,共8页
For a water supply system with long-distance diversion pipelines, in addition to the water hammer problems that occur beyond pumps, the safety of the water diversion pipeline in front of pumps also deserves attention.... For a water supply system with long-distance diversion pipelines, in addition to the water hammer problems that occur beyond pumps, the safety of the water diversion pipeline in front of pumps also deserves attention. In this study, a water hammer protection scheme combined with an overflow surge tank and a regulating valve was developed. A mathematical model of the overflow surge tank was developed, and an analytical formula for the height of the overflow surge tank was derived. Furthermore, a practical water supply project was used to evaluate the feasibility of the combined protection scheme and analyze the sensitivity of valve regulation rules. The results showed that the combined protection scheme effectively reduced the height of the surge tank, lessened the difficulties related to construction, and reduced the necessary financial investment for the project. The two-stage closing rule articulated as fast first and then slow could minimize the overflow volume of the surge tank when the power failure occurred, while the two-stage opening rule articulated as slow first and then fast could be more conducive to the safety of the water supply system when the pump started up. 展开更多
关键词 Long-distance diversion pipeline water supply water hammer Overflow surge tank Regulating valve
下载PDF
Seismic performance evaluation of water supply pipes installed in a full-scale RC frame structure based on a shaking table test
13
作者 Wu Houli Guo Endong +2 位作者 Wang Jingyi Dai Xin Dai Chenxi 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2024年第1期163-178,共16页
As an important part of nonstructural components,the seismic response of indoor water supply pipes deserves much attention.This paper presents shaking table test research on water supply pipes installed in a full-scal... As an important part of nonstructural components,the seismic response of indoor water supply pipes deserves much attention.This paper presents shaking table test research on water supply pipes installed in a full-scale reinforced concrete(RC)frame structure.Different material pipes and different methods for penetrating the reinforced concrete floors are combined to evaluate the difference in seismic performance.Floor response spectra and pipe acceleration amplification factors based on test data are discussed and compared with code provisions.A seismic fragility study of displacement demand is conducted based on numerical simulation.The acceleration response and displacement response of different combinations are compared.The results show that the combination of different pipe materials and different passing-through methods can cause obvious differences in the seismic response of indoor riser pipes. 展开更多
关键词 water supply pipe different materials shaking table test amplification factor seismic fragility
下载PDF
Rural Resilience: A Comprehensive Study on Water Supply, Sanitation, Disease Patterns, and Hygiene Practices in Munshiganj, Bangladesh
14
作者 Jubayer Hoque Rifat Islam +6 位作者 Md. Mustafizur Rahman Md. Golam Rabbani Md. Selim Reja Saifur Rahman Soykat Saim Raiyan Md. Shafiqul Ahsan Emon Sakil Khan 《Journal of Environmental Protection》 2024年第1期63-75,共13页
This research project investigates the current status of water supply, sanitation, and hygiene practices in Munshiganj District, Bangladesh. Data collection involved a structured questionnaire and a reconnaissance sur... This research project investigates the current status of water supply, sanitation, and hygiene practices in Munshiganj District, Bangladesh. Data collection involved a structured questionnaire and a reconnaissance survey. Findings reveal that 30% of individuals rely on surface water (hand-tube wells, rivers, and ponds), prioritized as canal > river > pond, while 70% depend on groundwater (subterranean electric motor, deep tube-well). Drinking water is generally sufficient, with 95% reporting adequacy throughout the year. About 45% use hand tube-well water, 28% use deep tube-well water, and 11% use supply tap water for various purposes. Bathing trends include underground water through electric motor > pond > hand tube-well water > river, while for cooking, the order is underground water through electric motor > pond > hand tube-well water > river. Toilet water supply ranks as supply tap water > hand tube-well water > deep tube-well water. Although sanitation awareness is high, some lack knowledge of good hygiene practices. After defecating, handwashing methods include soap, ash, soil, or water. Children’s waste disposal varies, with some discarding it in open areas. Approximately 40% suffer from diseases like Diarrhoea due to unsafe water, primarily affecting children and elders. Training exists, but a significant portion lacks sanitation education. Dry skin or exposure to cold water may cause temporary irritation. Local government involvement in sanitation efforts is less active compared to non-governmental organizations. Results emphasize the need to enhance community awareness of safe water supplies and sanitation practices. . 展开更多
关键词 water supply Sanitation Practices Hygiene Awareness Groundwater Dependency Community Health Intervention
下载PDF
Analysis of Municipal Water Supply and Drainage Pipe Design Technology
15
作者 Liang Liu 《Journal of Architectural Research and Development》 2024年第3期69-74,共6页
The quality and safety of residents’water rely heavily on the design of municipal water supply and drainage pipes.Therefore,this paper aims to enhance the optimization of municipal water supply and drainage pipe desi... The quality and safety of residents’water rely heavily on the design of municipal water supply and drainage pipes.Therefore,this paper aims to enhance the optimization of municipal water supply and drainage pipe design by focusing on design requirements,principles,and key elements.Drawing from relevant design optimization experiences,technology advancements,and optimization measures,the research will analyze and consolidate the essential aspects of municipal water supply and drainage pipe design.The goal is to fundamentally elevate the quality standards of these designs,ensuring they meet the criteria for engineering project excellence.Through this comprehensive approach,we aim to contribute to the improvement and sustainability of water supply and drainage systems,safeguarding the well-being of residents. 展开更多
关键词 Municipal water supply and drainage Pipe layout RAINwater SEWAGE Design technology
下载PDF
Selection of Water Transmission Method and Analysis of Pipe Network Zoning in Municipal Water Supply and Drainage Design
16
作者 Liang Liu 《Journal of World Architecture》 2024年第2期56-61,共6页
With the acceleration of urbanization,the demand for water supply and drainage pipe networks has increased significantly.In the planning of urban construction,it is necessary to optimize the design of the water supply... With the acceleration of urbanization,the demand for water supply and drainage pipe networks has increased significantly.In the planning of urban construction,it is necessary to optimize the design of the water supply and drainage system pipe network to effectively save energy while providing residents with more accessible water resources.Therefore,the municipal water supply and drainage system and the water transmission methods should be designed according to the geographical conditions of the city.In this paper,we mainly analyze the design of municipal water supply and drainage systems and the selection of water transmission methods.Besides,the optimization of the water supply and drainage network zoning process and pipe network maintenance is also discussed,so as to provide a reference for municipal water supply and drainage work. 展开更多
关键词 Municipal water supply and drainage design water transmission method Pipe network zoning maintenance
下载PDF
Application of LINGO to the Solution of the Water Supply System′s Optimal Operation Model 被引量:1
17
作者 牛志广 张宏伟 《Transactions of Tianjin University》 EI CAS 2002年第4期246-250,共5页
In this research, LINGO is used successfully to solve the water supply system′s optimal operation model. Firstly, the language of LINGO and the using method were studied intensively, on the basis of which the model w... In this research, LINGO is used successfully to solve the water supply system′s optimal operation model. Firstly, the language of LINGO and the using method were studied intensively, on the basis of which the model was transformed to LINGO form and solved successfully. Secondly, the research on the interface between LINGO and the popular office software was made. The optimization software was developed, which had Excel as the workspace and LINGO as the core of computation. Through practice, this software was found stable, easy to use and suitable for the application to the water supply corporations. 展开更多
关键词 LINGO optimal operation of water supply system solution of the model INTERFACE
全文增补中
Decision Support System for emergency scheduling of raw water supply systems with multiple sources 被引量:2
18
作者 Qi WANG Shuming LIU +2 位作者 Wenjun LIU Zoran KAPELAN Dragan SAVIC 《Frontiers of Environmental Science & Engineering》 SCIE EI CAS CSCD 2013年第5期777-786,共10页
A hydraulic model-based emergency schedul- ing Decision Support System (DSS) is designed to eliminate the impact of sudden contamination incidents occurring upstream in raw water supply systems with multiple sources... A hydraulic model-based emergency schedul- ing Decision Support System (DSS) is designed to eliminate the impact of sudden contamination incidents occurring upstream in raw water supply systems with multiple sources. The DSS consists of four functional modules, including water quality prediction, system safety assessment, emergency strategy inference and scheduling optimization. The work flow of the DSS is as follows. First, the water quality variations on specific cross-sections are calculated given the pollution information. Next, a comprehensive evaluation on the safety of the current system is conducted using the outputs in the first module. This will assist in the assessment of whether the system is in danger of failure, taking both the impact of pollution and system capacity into account. If there is a severe impact of contamination on the reliability of the system, a fuzzy logic based inference module is employed to generate reason- able strategies including technical measures. Otherwise, a Genetic Algorithm (GA)-based optimization model will be used to find the least-cost scheduling plan. The proposed DSS has been applied to a coastal city in South China during a saline tide period as validation. Through scenario analysis, it is demonstrated that this DSS tool is instrumental in emergency scheduling for the water company to quickly and effectively respond to sudden contamination incidents. 展开更多
关键词 decision support system raw water supply system contamination incident emergency scheduling hydraulic model safety assessment
原文传递
A survey on heavy metal concentrations in residential neighborhoods: The influence of secondary water supply systems 被引量:1
19
作者 Dong Hu Jie Zeng +4 位作者 Yue Hu Xiali Fei Xinyan Xiao Mingbao Feng Xin Yu 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2022年第7期37-45,共9页
Water quality deterioration often occurs in secondary water supply systems(SWSSs), and increased heavy metal concentrations can be a serious problem. In this survey, twelve residential neighborhoods were selected to i... Water quality deterioration often occurs in secondary water supply systems(SWSSs), and increased heavy metal concentrations can be a serious problem. In this survey, twelve residential neighborhoods were selected to investigate the influence of SWSSs on the seasonal changes in heavy metal concentrations from input water to tank and tap water. The concentrations of nine evaluated heavy metals in all groups of water samples were found to be far below the specified standard levels in China. The concentrations of Fe, Mn, and Zn increased significantly from the input water samples to the tank and tap water samples in spring and summer( p < 0.05), especially for the water samples that had been stagnant for a long time. Negative correlations were found between most of the heavy metals and residual chlorine(Fe, Cu, Zn, and As, r =-0.186 to-0.519, p < 0.05). In particular, a high negative correlation was observed between Fe and residual chlorine( r =-0.489 to-0.519, p < 0.01) in spring and summer. Fe and Mn displayed positive correlations with turbidity( r = 0.672 and 0.328, respectively;p < 0.05). In addition, Cr and As were found to be positively associated with some nutrients(NO, TN, and SO;r = 0.420-0.786, p < 0.01). The material of the storage tanks had little influence on the difference in heavy metal concentrations. Overall, this survey illustrated that SWSSs may pose a chronic threat to water quality and could provide useful information for practitioners. 展开更多
关键词 Residential neighborhoods Secondary water supply systems Tank materials water stagnation Residual chlorine Heavy metals
原文传递
Research on Leak Location Method of Water Supply Pipeline Based on MVMD 被引量:1
20
作者 Qiansheng Fang Haojie Wang +1 位作者 Chenlei Xie Jie Chen 《Computer Modeling in Engineering & Sciences》 SCIE EI 2023年第2期1237-1250,共14页
At present,the leakage rate of the water distribution network in China is still high,and the waste of water resources caused by water distribution network leakage is quite serious every year.Therefore,the location of ... At present,the leakage rate of the water distribution network in China is still high,and the waste of water resources caused by water distribution network leakage is quite serious every year.Therefore,the location of pipeline leakage is of great significance for saving water resources and reducing economic losses.Acoustic emission technology is the most widely used pipeline leak location technology.The traditional non-stationary random signal de-noising method mainly relies on the estimation of noise parameters,ignoring periodic noise and components unrelated to pipeline leakage.Aiming at the above problems,this paper proposes a leak location method for water supply pipelines based on a multivariate variational mode decomposition algorithm.This method combines the two parameters of the energy loss coefficient and the correlation coefficient between adjacent modes,and adaptively determines the decomposition mode number K according to the characteristics of the signal itself.According to the correlation coefficient,the effective component is selected to reconstruct the signal and the cross-correlation time delay is estimated to determine the location of the pipeline leakage point.The experimental results show that this method has higher accuracy than the cross-correlation method based on VMD and the cross-correlation method based on EMD,and the average relative positioning error is less than 2.2%. 展开更多
关键词 water supply pipeline leak location multivariate variational mode decomposition energy loss coefficient CROSS-CORRELATION
下载PDF
上一页 1 2 7 下一页 到第
使用帮助 返回顶部