With the acceleration of urbanization,the demand for water supply and drainage pipe networks has increased significantly.In the planning of urban construction,it is necessary to optimize the design of the water supply...With the acceleration of urbanization,the demand for water supply and drainage pipe networks has increased significantly.In the planning of urban construction,it is necessary to optimize the design of the water supply and drainage system pipe network to effectively save energy while providing residents with more accessible water resources.Therefore,the municipal water supply and drainage system and the water transmission methods should be designed according to the geographical conditions of the city.In this paper,we mainly analyze the design of municipal water supply and drainage systems and the selection of water transmission methods.Besides,the optimization of the water supply and drainage network zoning process and pipe network maintenance is also discussed,so as to provide a reference for municipal water supply and drainage work.展开更多
The potability of drinking water depends not only on the source and the treatment system, but also on the quality of the waterworks. In fact, the quality of drinking water is considerably degraded by the dilapidated s...The potability of drinking water depends not only on the source and the treatment system, but also on the quality of the waterworks. In fact, the quality of drinking water is considerably degraded by the dilapidated state and lack of maintenance of drinking water networks. In Côte d’Ivoire, the majority of drinking water networks in the various towns are ageing. In Daloa, despite the efforts made by the company in charge of water treatment and distribution to make the water drinkable, the water at consumers’ taps is often colored, has an unpleasant aftertaste and settles after collection. As a result, people are concerned about the potability of tap water, and some are turning to alternative sources of drinking water of unknown quality. In order to determine the factors responsible for the deterioration in water color and taste, as well as the sectors of the network most affected, a diagnosis of the network’s equipment was carried out. Water samples taken from the network were analyzed for color and turbidity. The diagnosis revealed that most of the equipment (suction pads, valves, drains and fire hydrants) is outdated and irregularly maintained. Analyses show that the water is more colored in cast-iron and PVC pipes than in asbestos cement pipes. Coloration values in the network range from 0 to 27 UVC for asbestos cement pipes, from 15 to 56 UCV for ductile iron pipes, and from 11 to 102 UCV for PVC pipes. On the over hand, turbidity values vary from 8.02 to 3.32 NTU for ductile cast iron pipes, 8.51 to 16.98 NTU for asbestos cement pipes and 0.9 to 6.98 NTU for PVC pipes. Old cast-iron pipes release ferric ions on contact with water, degrading their color. Old cast-iron pipes release ferric ions into the water, degrading its color. The high color values observed in the vicinity of drains are thought to be due to irregular maintenance of the network. In fact, after network maintenance, a reduction rate ranging from 2% to 73% is observed for turbidity, while for color, the rate varies from 5% to 72%. In short, the network’s obsolescence and irregular maintenance contribute significantly to the deterioration of water quality.展开更多
A district heating and hot water supply system is presented which synthetically utilizes geothermal energy,solar thermal energy and natural gas thermal energy.The multi-energy utilization system has been set at the ne...A district heating and hot water supply system is presented which synthetically utilizes geothermal energy,solar thermal energy and natural gas thermal energy.The multi-energy utilization system has been set at the new campus of Tianjin Polytechnic University(TPU),A couple of deep geothermal wells which are 2 300 m in depth were dug,Deep geothermal energy cascade utilization is achieved by two stages of plate heat exchangers(PHE) and two stages of water source heat pumps(WSHP).Shallow geothermal energy is used in assistant heating by two ground coupled heat pumps(GCHPs) with 580 vertical ground wells which are 120 m in depth.Solar thermal energy collected by vacuum tube arrays(VTAs) and geothermal energy are complementarily utilized to make domestic hot water.Superfluous solar energy can be stored in shallow soil for the GCHP utilization.The system can use fossil fuel thermal energy by two natural gas boilers(NGB) to assist in heating and making hot water.The heating energy efficiency was measured in the winter of 2010-2011.The coefficients of performance(COP) under different heating conditions are discussed.The performance of hot water production is tested in a local typical winter day and the solar thermal energy utilization factor is presented.The rusults show that the average system COP is 5.75 or 4.96 under different working conditions,and the typical solar energy utilization factor is 0.324.展开更多
This study used multinomial logistic regression and Bayesian belief networks(BBN)to analyze factors influenc-ing the functionality of the community-based rural drinking water supply and sanitation program(PAMSIMAS)in ...This study used multinomial logistic regression and Bayesian belief networks(BBN)to analyze factors influenc-ing the functionality of the community-based rural drinking water supply and sanitation program(PAMSIMAS)in Indonesia.28,936 PAMSIMAS projects in 33 provinces in Indonesia were analyzed.The data indicates that 85.4%of the water supply systems were fully functioning,9.1%were partially functioning,and 5.5%were not functioning.In the regression analysis,good management is positively associated with functionality and a high investment per capita is negatively associated with the functionality.The latter suggests the need for comprehen-sive economic analysis in the feasibility study in scattered housing sites and remote-undeveloped areas.We also found that high community participation at the beginning of the project was associated with the not functioning system,while women’s participation was positively associated with the functionality.Furthermore,the household connection is more likely to be functioning than communal connection.BBN analysis shows if the beneficiaries do not pay for water,the probability of not functioning systems is 20 times higher than systems with fee collec-tion.Moreover,the combination of strong management,strong financial status,and household connection rather than communal connection increases the probability of fully functioning to 98%.Improvement of data collection is also necessary to monitor the current conditions of all PAMSIMAS systems in Indonesia.This study offers a country-level perspective for better implementation of the community-based rural water supply and sanitation program in developing countries.展开更多
Through the transformation of hydraulic constraints into the objective functions associated with a water supply network rehabilitation problem, a non-dominated sorting Genetic Algorithm-II (NSGA-II) can be used to sol...Through the transformation of hydraulic constraints into the objective functions associated with a water supply network rehabilitation problem, a non-dominated sorting Genetic Algorithm-II (NSGA-II) can be used to solve the altered multi-objective optimization model. The introduction of NSGA-II into water supply network optimal rehabilitation problem solves the conflict between one fitness value of standard genetic algorithm (SGA) and multi-objectives of rehabilitation problem. And the uncertainties brought by using weight coefficients or punish functions in conventional methods are controlled. And also by in-troduction of artificial inducement mutation (AIM) operation, the convergence speed of population is accelerated;this operation not only improves the convergence speed, but also improves the rationality and feasibility of solutions.展开更多
The serviceability of water supply networks(WSNs)under seismic loads has significant importance for estimating the probable losses and the impact of diminished functionality on affected communities.The innovation pres...The serviceability of water supply networks(WSNs)under seismic loads has significant importance for estimating the probable losses and the impact of diminished functionality on affected communities.The innovation presented in this paper is suggesting a new strategy to evaluate the seismic serviceability of WSNs,utilizing their operational physical mechanism.On one hand,this method can obtain the seismic serviceability of each node as well as entire WSNs.On the other hand,this method can dynamically reflect the propagation of randomness from ground motions to WSNs.First,a finite element model is established to capture the seismic response of buried pipe networks,and a leakage model is suggested to obtain the leakage area of WSNs.Second,the transient flow analysis of WSNs with or without leakage is derived to obtain dynamic water flow and pressure.Third,the seismic serviceability of WSNs is analyzed based on the probability density evolution method(PDEM).Finally,the seismic serviceability of a real WSN in Mianzhu city is assessed to illustrate the method.The case study shows that randomness from the ground motions can obviously affect the leakage state and the probability density of the nodal head during earthquakes.展开更多
This paper deals with the use of optimal control techniques in large-scale water distribution networks. According to the network characteristics and actual state of the water supply system in China, the implicit model...This paper deals with the use of optimal control techniques in large-scale water distribution networks. According to the network characteristics and actual state of the water supply system in China, the implicit model, which may be solved by utilizing the hierarchical optimization method, is established. In special, based on the analyses of the water supply system containing variable-speed pumps, a software tool has been developed successfully. The application of this model to the city of Shenyang (China) is compared to experiential strategy. The results of this study show that the developed model is a very promising optimization method to control the large-scale water supply systems.展开更多
An urban water supply network(WSN)is a crucial lifeline system that helps to maintain the normal functioning of modern society.However,the hydraulic analysis of a significantly damaged WSN that suffers from pipe break...An urban water supply network(WSN)is a crucial lifeline system that helps to maintain the normal functioning of modern society.However,the hydraulic analysis of a significantly damaged WSN that suffers from pipe breaks or leaks remains challenging.In this paper,a probability-based framework is proposed to assess the functionality of WSNs in the aftermath of powerful earthquakes.The serviceability of the WSN is quantified by using a comprehensive index that considers nodal water flow and nodal pressure.This index includes a coefficient that reflects the relative importance of these two parameters.The demand reduction(DR)method,which reduces the water flow of nodes while preventing the negative pressure of nodes,is proposed.The difference between the negative pressure elimination(NPE)method and the DR method is discussed by using the example of a WSN in a medium-sized city in China.The functionality values of the WSN are 0.76 and 0.99 when nodal pressure and nodal demands are used respectively as the index of system serviceability at an intensity level that would pertain to an earthquake considered to occur at a maximum level.When the intensity of ground motion is as high as 0.4 g,the DR method requires fewer samples than the NPE method to obtain accurate results.The NPE method eliminates most of the pipes,which may be unrealistic.展开更多
Limited-heating is one of the heating statuses which can meet the reliability requirement of those uninterrupted heat-users under the accidental status of heat-supply network.It requires the network to be provided wit...Limited-heating is one of the heating statuses which can meet the reliability requirement of those uninterrupted heat-users under the accidental status of heat-supply network.It requires the network to be provided with both ability of spare-structure and spare-transportation,and the later one is depended on the limited-flux coefficient.This paper investigates the relationship between the limited-flux coefficient and limited-heating coefficient of indirect connection system.The optimal value of the limited-flux coefficient is presented as well.展开更多
Water supply network losses are an international problem especially in countries suffering from water scarcity like Jordan. Jordan is one of the poorest countries in its water resources and it is estimated to be below...Water supply network losses are an international problem especially in countries suffering from water scarcity like Jordan. Jordan is one of the poorest countries in its water resources and it is estimated to be below the water poverty line. Jordan is located in the Middle East and has a surface area of approximately 90,000 km2. Its population is around 6.3 million and it is estimated that the population will be 7.8 million in 2022. The gap between water supply and demand is widening due to development and a relatively high population growth rate. In addition, global climate change is expected to intensify the water shortage problem in Jordan. Thirteen years of complete records obtained from the Ministry of Water and Irrigation were analyzed. According to these records, water losses in Jordan reach about 50%. In view of the evaluation of the data and the case study conducted in this research, it is believed that Jordan can overcome the water shortage problem by adopting a water demand management strategy. In this context, efforts should be focused on reducing water losses. If this is achieved, it will save huge quantities of water and revenue.展开更多
Decision making in drinking water supply networks is increasingly complex due to the large number of variables involved.In order to make better decisions it is necessary to use adequate and robust methodologies.This p...Decision making in drinking water supply networks is increasingly complex due to the large number of variables involved.In order to make better decisions it is necessary to use adequate and robust methodologies.This paper presents the application of the Analytic Hierarchy Process(AHP)related to the operation of the drinking water supply network of the city of Chihuahua,Mexico,where two possible alternatives are delineated with the objective to optimize the service.The application of AHP was carried out in 24 sectors that have substantial differences in their efficiency but with instrumentation and measurement in all the variables contemplated by the operating agency,with a population of 221,722 inhabitants which represent a 30%of the total population of the city,the results indicate that the best alternative is the one with less criteria to be controlled and fewer repercussions on the cost of operation and investment in the rehabilitation and replacement of the network.展开更多
This study investigated a water supply recovery problem involving municipal water service piping. The problem consisted in recovering full service after network failure, in order to rapidly satisfy all urgent citywide...This study investigated a water supply recovery problem involving municipal water service piping. The problem consisted in recovering full service after network failure, in order to rapidly satisfy all urgent citywide demands. The optimal recovery solution was achieved through the application of so-called network design problems (NDPs), which are a form of combinatorial optimization problem. However, a conventional NDP is not suitable for addressing urgent situations because (1) it does not utilize the non-failure arcs in the network, and (2) it is solely concerned with stable costs such as flow costs. Therefore, to adapt the technique to such urgent situations, the conventional NDP is here modified to deal with the specified water supply problem. In addition, a numerical illustration using the Sendai water network is presented.展开更多
Contamination of water reserves by biological, chemical, and radiologic agents may affect the health of millions of residents in the Iraq as well as many others throughout the world. Fatal outbreaks of cholera struck ...Contamination of water reserves by biological, chemical, and radiologic agents may affect the health of millions of residents in the Iraq as well as many others throughout the world. Fatal outbreaks of cholera struck several provinces of the country, including Baghdad. The United Nations Environment Programme (UNEP) also says air pollution, resulting from burning oil and aggravated by war, is cause for concern. The study area Baghdad has been divided into two parts: Central Baghdad and Outskirts of Baghdad (included in Baghdad but near the boundaries of Baghdad). The outskirts of Baghdad comprises of 4 cities: Al-Hussaniya located in northern part of Baghdad, Abu-Gurabe located in the western side of Baghdad, Jissr Diyala located in the eastern side of Baghdad and finally Al-Mahmodiya located in the southern side of Baghdad. These cities are in very poor situation in terms of water supply. The quality of water supplied is bad as no attention is given to WTP's in these places, which is also because of the fact that given the insecure war conditions, these areas are inaccessible. The sewage is thrown directly into the river because these areas do not have sewage treatment plants. In case of central Baghdad the water supply and sewerage network are broken in some places. Due to this there is mixing of water between the two networks. For this study we taking water supply samples and collect all the samples from WTPs and water supply network (houses, shops and different places). We made the analysis to parts first bacteriologies, second chlorine and after analysis these samples in lab we will give in our study numbers of fail samples, type of diseases and how many case during year 2007 in Baghdad City. Also in this study we will give Estimated Deaths from Water-Related Diseases 2010 to 2035.展开更多
In the Gambia and across sub-Saharan Africa, reliable access to clean water and electrical power is constrained. As most rural water supply systems are built, enhanced understanding of efficiencies and optimisation is...In the Gambia and across sub-Saharan Africa, reliable access to clean water and electrical power is constrained. As most rural water supply systems are built, enhanced understanding of efficiencies and optimisation is required. Here, methods of integrating estimations of power outputs from solar photovoltaic arrays into gravity-fed water distribution network modelling are investigated. The effects of powering a rural water distribution system that is replenished with groundwater pumps that use solar power are investigated, along with the effect of this on other network design decisions. The water storage tank and pipework of a rural community with an estimated 2800 people and 28 standpipes from a borehole was selected. EPANET modelling software and genetic algorithms were used to run network optimisation simulations of: water tank location, elevation and volume;pipe diameter and configuration;and optimal system design in terms of cost. Different scenarios were produced, including supply, demand and required water storage curves, which could have practical application for rural water distribution system design. Indicative costs for theoretical water distribution networks will be useful for decision makers and planners.展开更多
In this paper we address the problem of pressure management in water supply system (WSS) network. The model-based predictive control (MPC) strategies have some important features to deal with WSS. By hydraulic ana...In this paper we address the problem of pressure management in water supply system (WSS) network. The model-based predictive control (MPC) strategies have some important features to deal with WSS. By hydraulic analysis of WSS, the predictive model is derived from the dynamic model and static model of WSS. Through WSS, the consumers' demands are required to be met at all times according to some operational constraints that must be satisfied. The constraints of flow through actuators, the water level of reservoirs and the consumer areas' pressure demand are determined by a specific system. In this work, we develop a constrained MPC controller that considers the zone control of the pressure outputs and incorporates steady state economic targets in the control cost function. The designed management strategies are applied to a case study and simulation results, covering different aspects, are provided. The output nodal pressure can be controlled in the desired zone by optimal scheduling the actuators of the WSS. If the variation range of reservoir's water level is broader, the rate of flow through the actuators is gentle, and vice versa.展开更多
This paper introduces a non-iterative algorithmic procedure to design water utilization networks with multiple contaminants in process plants. According to the water pinch analysis rules, the processes in water utiliz...This paper introduces a non-iterative algorithmic procedure to design water utilization networks with multiple contaminants in process plants. According to the water pinch analysis rules, the processes in water utilization systems were first divided into three groups, then water-supply priority algorithm was proposed. The results of case studies showed that the water networks designed by this method gave water consumption lower than that estimated by other approaches. In addition, the procedure was subject to no limitation on the problem scale.展开更多
In order to overcome the low precision and weak applicability problems of the current municipal water network state simulation model, the water network structure is studied. Since the telemetry system has been applied...In order to overcome the low precision and weak applicability problems of the current municipal water network state simulation model, the water network structure is studied. Since the telemetry system has been applied increasingly in the water network, and in order to reflect the network operational condition more accurately, a new water network macroscopic model is developed by taking the auto-control adjusting valve opening state into consideration. Then for highly correlated or collinear independent variables in the model, the partial least squares (PLS) regression method provides a model solution which can distinguish between the system information and the noisy data. Finally, a hypothetical water network is introduced for validating the model. The simulation results show that the relative error is less than 5.2%, indicating that the model is efficient and feasible, and has better generalization performance.展开更多
Corrosion has been reported to occur in the copper tubes of heat ex-changers in multiple-circulation hot water supply systems. We have been investigating the applicability of high-strength Cu-0.65 mass% Sn-0.014 mass%...Corrosion has been reported to occur in the copper tubes of heat ex-changers in multiple-circulation hot water supply systems. We have been investigating the applicability of high-strength Cu-0.65 mass% Sn-0.014 mass% Zr-0.020 mass% P alloy to counteract this corrosion. Immersion tests, electrochemical measurements, and field tests were performed. Excellent corrosion resistance of the alloy was established under conditions with flowing water due to the formation of composite films containing tin. The alloy is expected to be better than copper as a corrosion-resistant material for heat exchanger tubes.展开更多
文摘With the acceleration of urbanization,the demand for water supply and drainage pipe networks has increased significantly.In the planning of urban construction,it is necessary to optimize the design of the water supply and drainage system pipe network to effectively save energy while providing residents with more accessible water resources.Therefore,the municipal water supply and drainage system and the water transmission methods should be designed according to the geographical conditions of the city.In this paper,we mainly analyze the design of municipal water supply and drainage systems and the selection of water transmission methods.Besides,the optimization of the water supply and drainage network zoning process and pipe network maintenance is also discussed,so as to provide a reference for municipal water supply and drainage work.
文摘The potability of drinking water depends not only on the source and the treatment system, but also on the quality of the waterworks. In fact, the quality of drinking water is considerably degraded by the dilapidated state and lack of maintenance of drinking water networks. In Côte d’Ivoire, the majority of drinking water networks in the various towns are ageing. In Daloa, despite the efforts made by the company in charge of water treatment and distribution to make the water drinkable, the water at consumers’ taps is often colored, has an unpleasant aftertaste and settles after collection. As a result, people are concerned about the potability of tap water, and some are turning to alternative sources of drinking water of unknown quality. In order to determine the factors responsible for the deterioration in water color and taste, as well as the sectors of the network most affected, a diagnosis of the network’s equipment was carried out. Water samples taken from the network were analyzed for color and turbidity. The diagnosis revealed that most of the equipment (suction pads, valves, drains and fire hydrants) is outdated and irregularly maintained. Analyses show that the water is more colored in cast-iron and PVC pipes than in asbestos cement pipes. Coloration values in the network range from 0 to 27 UVC for asbestos cement pipes, from 15 to 56 UCV for ductile iron pipes, and from 11 to 102 UCV for PVC pipes. On the over hand, turbidity values vary from 8.02 to 3.32 NTU for ductile cast iron pipes, 8.51 to 16.98 NTU for asbestos cement pipes and 0.9 to 6.98 NTU for PVC pipes. Old cast-iron pipes release ferric ions on contact with water, degrading their color. Old cast-iron pipes release ferric ions into the water, degrading its color. The high color values observed in the vicinity of drains are thought to be due to irregular maintenance of the network. In fact, after network maintenance, a reduction rate ranging from 2% to 73% is observed for turbidity, while for color, the rate varies from 5% to 72%. In short, the network’s obsolescence and irregular maintenance contribute significantly to the deterioration of water quality.
基金Project(2010DFA72740-06) supported by International Science & Technology Cooperation Program of China
文摘A district heating and hot water supply system is presented which synthetically utilizes geothermal energy,solar thermal energy and natural gas thermal energy.The multi-energy utilization system has been set at the new campus of Tianjin Polytechnic University(TPU),A couple of deep geothermal wells which are 2 300 m in depth were dug,Deep geothermal energy cascade utilization is achieved by two stages of plate heat exchangers(PHE) and two stages of water source heat pumps(WSHP).Shallow geothermal energy is used in assistant heating by two ground coupled heat pumps(GCHPs) with 580 vertical ground wells which are 120 m in depth.Solar thermal energy collected by vacuum tube arrays(VTAs) and geothermal energy are complementarily utilized to make domestic hot water.Superfluous solar energy can be stored in shallow soil for the GCHP utilization.The system can use fossil fuel thermal energy by two natural gas boilers(NGB) to assist in heating and making hot water.The heating energy efficiency was measured in the winter of 2010-2011.The coefficients of performance(COP) under different heating conditions are discussed.The performance of hot water production is tested in a local typical winter day and the solar thermal energy utilization factor is presented.The rusults show that the average system COP is 5.75 or 4.96 under different working conditions,and the typical solar energy utilization factor is 0.324.
文摘This study used multinomial logistic regression and Bayesian belief networks(BBN)to analyze factors influenc-ing the functionality of the community-based rural drinking water supply and sanitation program(PAMSIMAS)in Indonesia.28,936 PAMSIMAS projects in 33 provinces in Indonesia were analyzed.The data indicates that 85.4%of the water supply systems were fully functioning,9.1%were partially functioning,and 5.5%were not functioning.In the regression analysis,good management is positively associated with functionality and a high investment per capita is negatively associated with the functionality.The latter suggests the need for comprehen-sive economic analysis in the feasibility study in scattered housing sites and remote-undeveloped areas.We also found that high community participation at the beginning of the project was associated with the not functioning system,while women’s participation was positively associated with the functionality.Furthermore,the household connection is more likely to be functioning than communal connection.BBN analysis shows if the beneficiaries do not pay for water,the probability of not functioning systems is 20 times higher than systems with fee collec-tion.Moreover,the combination of strong management,strong financial status,and household connection rather than communal connection increases the probability of fully functioning to 98%.Improvement of data collection is also necessary to monitor the current conditions of all PAMSIMAS systems in Indonesia.This study offers a country-level perspective for better implementation of the community-based rural water supply and sanitation program in developing countries.
基金the Natural Science Key Foundation of Heilongjiang Province of China (No. ZJG0503) China-UK Sci-ence Network from Royal Society UK
文摘Through the transformation of hydraulic constraints into the objective functions associated with a water supply network rehabilitation problem, a non-dominated sorting Genetic Algorithm-II (NSGA-II) can be used to solve the altered multi-objective optimization model. The introduction of NSGA-II into water supply network optimal rehabilitation problem solves the conflict between one fitness value of standard genetic algorithm (SGA) and multi-objectives of rehabilitation problem. And the uncertainties brought by using weight coefficients or punish functions in conventional methods are controlled. And also by in-troduction of artificial inducement mutation (AIM) operation, the convergence speed of population is accelerated;this operation not only improves the convergence speed, but also improves the rationality and feasibility of solutions.
基金National Natural Science Foundation of China under Grant No.5210082055China Postdoctoral Science Foundation under Grant No.2021M690278。
文摘The serviceability of water supply networks(WSNs)under seismic loads has significant importance for estimating the probable losses and the impact of diminished functionality on affected communities.The innovation presented in this paper is suggesting a new strategy to evaluate the seismic serviceability of WSNs,utilizing their operational physical mechanism.On one hand,this method can obtain the seismic serviceability of each node as well as entire WSNs.On the other hand,this method can dynamically reflect the propagation of randomness from ground motions to WSNs.First,a finite element model is established to capture the seismic response of buried pipe networks,and a leakage model is suggested to obtain the leakage area of WSNs.Second,the transient flow analysis of WSNs with or without leakage is derived to obtain dynamic water flow and pressure.Third,the seismic serviceability of WSNs is analyzed based on the probability density evolution method(PDEM).Finally,the seismic serviceability of a real WSN in Mianzhu city is assessed to illustrate the method.The case study shows that randomness from the ground motions can obviously affect the leakage state and the probability density of the nodal head during earthquakes.
基金This work has been partly funded by the National Natural Science Foundation of China(No.50078048).
文摘This paper deals with the use of optimal control techniques in large-scale water distribution networks. According to the network characteristics and actual state of the water supply system in China, the implicit model, which may be solved by utilizing the hierarchical optimization method, is established. In special, based on the analyses of the water supply system containing variable-speed pumps, a software tool has been developed successfully. The application of this model to the city of Shenyang (China) is compared to experiential strategy. The results of this study show that the developed model is a very promising optimization method to control the large-scale water supply systems.
基金the Institute of Engineering Mechanics(IEM),China Earthquake Administration(CEA)under Grant No.2019EEEVL0505the National Natural Science Foundation of China under Grant No.51908519and the Scientific Research Fund of the IEM,CEA under Grant No.2019B02。
文摘An urban water supply network(WSN)is a crucial lifeline system that helps to maintain the normal functioning of modern society.However,the hydraulic analysis of a significantly damaged WSN that suffers from pipe breaks or leaks remains challenging.In this paper,a probability-based framework is proposed to assess the functionality of WSNs in the aftermath of powerful earthquakes.The serviceability of the WSN is quantified by using a comprehensive index that considers nodal water flow and nodal pressure.This index includes a coefficient that reflects the relative importance of these two parameters.The demand reduction(DR)method,which reduces the water flow of nodes while preventing the negative pressure of nodes,is proposed.The difference between the negative pressure elimination(NPE)method and the DR method is discussed by using the example of a WSN in a medium-sized city in China.The functionality values of the WSN are 0.76 and 0.99 when nodal pressure and nodal demands are used respectively as the index of system serviceability at an intensity level that would pertain to an earthquake considered to occur at a maximum level.When the intensity of ground motion is as high as 0.4 g,the DR method requires fewer samples than the NPE method to obtain accurate results.The NPE method eliminates most of the pipes,which may be unrealistic.
基金supported by National Natural Science Foundation of China(61233004,61221003,61374109,61104091,61304078,61473184)National Basic Research Program of China(973 Program)(2013CB035500)+2 种基金the International Cooperation Program of Shanghai Science and Technology Commission(12230709600)the Higher Education Research Fund for the Doctoral Program of China(20120073130006,20110073110018)the China Postdoctoral Science Foundation(2013M540364)
基金Sponsored by the National Natural Science Foundation of China(Grant No.50378029)the National Key Technologies R&D Program of China during the 11th Five-Year Plan Period(Grant No.2006BAJ16B03)
文摘Limited-heating is one of the heating statuses which can meet the reliability requirement of those uninterrupted heat-users under the accidental status of heat-supply network.It requires the network to be provided with both ability of spare-structure and spare-transportation,and the later one is depended on the limited-flux coefficient.This paper investigates the relationship between the limited-flux coefficient and limited-heating coefficient of indirect connection system.The optimal value of the limited-flux coefficient is presented as well.
文摘Water supply network losses are an international problem especially in countries suffering from water scarcity like Jordan. Jordan is one of the poorest countries in its water resources and it is estimated to be below the water poverty line. Jordan is located in the Middle East and has a surface area of approximately 90,000 km2. Its population is around 6.3 million and it is estimated that the population will be 7.8 million in 2022. The gap between water supply and demand is widening due to development and a relatively high population growth rate. In addition, global climate change is expected to intensify the water shortage problem in Jordan. Thirteen years of complete records obtained from the Ministry of Water and Irrigation were analyzed. According to these records, water losses in Jordan reach about 50%. In view of the evaluation of the data and the case study conducted in this research, it is believed that Jordan can overcome the water shortage problem by adopting a water demand management strategy. In this context, efforts should be focused on reducing water losses. If this is achieved, it will save huge quantities of water and revenue.
文摘Decision making in drinking water supply networks is increasingly complex due to the large number of variables involved.In order to make better decisions it is necessary to use adequate and robust methodologies.This paper presents the application of the Analytic Hierarchy Process(AHP)related to the operation of the drinking water supply network of the city of Chihuahua,Mexico,where two possible alternatives are delineated with the objective to optimize the service.The application of AHP was carried out in 24 sectors that have substantial differences in their efficiency but with instrumentation and measurement in all the variables contemplated by the operating agency,with a population of 221,722 inhabitants which represent a 30%of the total population of the city,the results indicate that the best alternative is the one with less criteria to be controlled and fewer repercussions on the cost of operation and investment in the rehabilitation and replacement of the network.
文摘This study investigated a water supply recovery problem involving municipal water service piping. The problem consisted in recovering full service after network failure, in order to rapidly satisfy all urgent citywide demands. The optimal recovery solution was achieved through the application of so-called network design problems (NDPs), which are a form of combinatorial optimization problem. However, a conventional NDP is not suitable for addressing urgent situations because (1) it does not utilize the non-failure arcs in the network, and (2) it is solely concerned with stable costs such as flow costs. Therefore, to adapt the technique to such urgent situations, the conventional NDP is here modified to deal with the specified water supply problem. In addition, a numerical illustration using the Sendai water network is presented.
文摘Contamination of water reserves by biological, chemical, and radiologic agents may affect the health of millions of residents in the Iraq as well as many others throughout the world. Fatal outbreaks of cholera struck several provinces of the country, including Baghdad. The United Nations Environment Programme (UNEP) also says air pollution, resulting from burning oil and aggravated by war, is cause for concern. The study area Baghdad has been divided into two parts: Central Baghdad and Outskirts of Baghdad (included in Baghdad but near the boundaries of Baghdad). The outskirts of Baghdad comprises of 4 cities: Al-Hussaniya located in northern part of Baghdad, Abu-Gurabe located in the western side of Baghdad, Jissr Diyala located in the eastern side of Baghdad and finally Al-Mahmodiya located in the southern side of Baghdad. These cities are in very poor situation in terms of water supply. The quality of water supplied is bad as no attention is given to WTP's in these places, which is also because of the fact that given the insecure war conditions, these areas are inaccessible. The sewage is thrown directly into the river because these areas do not have sewage treatment plants. In case of central Baghdad the water supply and sewerage network are broken in some places. Due to this there is mixing of water between the two networks. For this study we taking water supply samples and collect all the samples from WTPs and water supply network (houses, shops and different places). We made the analysis to parts first bacteriologies, second chlorine and after analysis these samples in lab we will give in our study numbers of fail samples, type of diseases and how many case during year 2007 in Baghdad City. Also in this study we will give Estimated Deaths from Water-Related Diseases 2010 to 2035.
文摘In the Gambia and across sub-Saharan Africa, reliable access to clean water and electrical power is constrained. As most rural water supply systems are built, enhanced understanding of efficiencies and optimisation is required. Here, methods of integrating estimations of power outputs from solar photovoltaic arrays into gravity-fed water distribution network modelling are investigated. The effects of powering a rural water distribution system that is replenished with groundwater pumps that use solar power are investigated, along with the effect of this on other network design decisions. The water storage tank and pipework of a rural community with an estimated 2800 people and 28 standpipes from a borehole was selected. EPANET modelling software and genetic algorithms were used to run network optimisation simulations of: water tank location, elevation and volume;pipe diameter and configuration;and optimal system design in terms of cost. Different scenarios were produced, including supply, demand and required water storage curves, which could have practical application for rural water distribution system design. Indicative costs for theoretical water distribution networks will be useful for decision makers and planners.
基金supported by National Natural Science Foundation of China(Nos.61233004 and 61221003)the National Basic Research Program of China(973 Program)(No.2013CB035500)the Higher Education Research Fund for the Doctoral Program of China(No.20120073130006)
文摘In this paper we address the problem of pressure management in water supply system (WSS) network. The model-based predictive control (MPC) strategies have some important features to deal with WSS. By hydraulic analysis of WSS, the predictive model is derived from the dynamic model and static model of WSS. Through WSS, the consumers' demands are required to be met at all times according to some operational constraints that must be satisfied. The constraints of flow through actuators, the water level of reservoirs and the consumer areas' pressure demand are determined by a specific system. In this work, we develop a constrained MPC controller that considers the zone control of the pressure outputs and incorporates steady state economic targets in the control cost function. The designed management strategies are applied to a case study and simulation results, covering different aspects, are provided. The output nodal pressure can be controlled in the desired zone by optimal scheduling the actuators of the WSS. If the variation range of reservoir's water level is broader, the rate of flow through the actuators is gentle, and vice versa.
文摘This paper introduces a non-iterative algorithmic procedure to design water utilization networks with multiple contaminants in process plants. According to the water pinch analysis rules, the processes in water utilization systems were first divided into three groups, then water-supply priority algorithm was proposed. The results of case studies showed that the water networks designed by this method gave water consumption lower than that estimated by other approaches. In addition, the procedure was subject to no limitation on the problem scale.
基金Supported by Tianjin Natural Science Foundation( No. 003611611).
文摘In order to overcome the low precision and weak applicability problems of the current municipal water network state simulation model, the water network structure is studied. Since the telemetry system has been applied increasingly in the water network, and in order to reflect the network operational condition more accurately, a new water network macroscopic model is developed by taking the auto-control adjusting valve opening state into consideration. Then for highly correlated or collinear independent variables in the model, the partial least squares (PLS) regression method provides a model solution which can distinguish between the system information and the noisy data. Finally, a hypothetical water network is introduced for validating the model. The simulation results show that the relative error is less than 5.2%, indicating that the model is efficient and feasible, and has better generalization performance.
文摘Corrosion has been reported to occur in the copper tubes of heat ex-changers in multiple-circulation hot water supply systems. We have been investigating the applicability of high-strength Cu-0.65 mass% Sn-0.014 mass% Zr-0.020 mass% P alloy to counteract this corrosion. Immersion tests, electrochemical measurements, and field tests were performed. Excellent corrosion resistance of the alloy was established under conditions with flowing water due to the formation of composite films containing tin. The alloy is expected to be better than copper as a corrosion-resistant material for heat exchanger tubes.