期刊文献+
共找到80篇文章
< 1 2 4 >
每页显示 20 50 100
A Three-Stage, Completely Sustainable Process Addressing Industrial Water Waste Treatment Management: The Case of the Sorption of Methylene Blue in Column Experiments
1
作者 Odysseas Kopsidas 《Journal of Environmental Science and Engineering(B)》 2020年第4期127-132,共6页
A detailed study regarding the optimization of a complete system for the purification of water waste is presented.Three main concerns are addressed:the nature of the absorbing material,the efficiency dependence on sca... A detailed study regarding the optimization of a complete system for the purification of water waste is presented.Three main concerns are addressed:the nature of the absorbing material,the efficiency dependence on scale and the management of the final waste of the assembly.These three points have to be optimized in the best acceptable way from an environmental point of view.Subsequently,the wet filling material,comprised of the absorbent and the absorbed dye,was buried in dry soil,promoting soil bacterial and fungal growth.The absorbance of CO2 was determined.The use of natural vegetative material as absorbents of chemical dyes in industrial water waste is an environmentally friendly solution.Combination with the utilization of the final solid waste as fertilizer is an optimum solution,promoting sustainability within an industrial ecology framework.The adsorption column scale-up studied herein,for the removal of basic dyes from wastewaters,using methylene blue as a representative adsorbate and barley straw as a representative waste biomass adsorbent,was successful,as regards consistency and reliability(judged by low absolute and relative standard deviation)of results. 展开更多
关键词 waste water treatment ABSORBANCE BIOAVAILABILITY industrial ecology
下载PDF
Efficient and rapid capture of uranium(Ⅵ) in wastewater via multiamine modified β-cyclodextrin porous polymer
2
作者 Xing Zhong Yubin Tan +6 位作者 Siyuan Wu Caixia Hu Kai Guo Yongchuan Wu Neng Yu Mingyang Ma Ying Dai 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2024年第4期144-155,共12页
It is quite important to ensure the safety and sustainable development of nuclear energy for the treatment of radioactive wastewater. To treat radioactive wastewater efficiently and rapidly, two multi-amine β-cyclode... It is quite important to ensure the safety and sustainable development of nuclear energy for the treatment of radioactive wastewater. To treat radioactive wastewater efficiently and rapidly, two multi-amine β-cyclodextrin polymers(diethylenetriamine β-cyclodextrin polymer(DETA-TFCDP) and triethylenetetramine β-cyclodextrin polymer(TETA-TFCDP)) were prepared and applied to capture uranium. Results exhibited that DETA-TFCDP and TETA-TFCDP displayed the advantages of high adsorption amounts(612.2and 628.2 mg·g-1, respectively) and rapid adsorption rates, which can reach(88 ± 1)% of their equilibrium adsorption amounts in 10 min. Moreover, the adsorbent processes of DETA-TFCDP and TETATFCDP on uranium(Ⅵ) followed the Langmuir model and pseudo-second-order model, stating they were mainly chemisorption and self-endothermic. Besides, TETA-TFCDP also showed excellent selectivity in the presence of seven competing cations and could be effectively reused five times via Na2CO3as the desorption reagent. Meanwhile, X-ray photoelectron spectroscopy and Fourier transform infrared spectroscopy illustrated that the enriched multi-amine groups and oxygen-containing functional groups on the surface of TETA-TFCDP were the main active sites for capturing uranium(Ⅵ). Hence, multi-amine β-cyclodextrin polymers are a highly efficient, rapid, and promising adsorbent for capturing uranium(Ⅵ)from radioactive wastewater. 展开更多
关键词 Adsorption waste water Pollution Uranium(VI) b-Cyclodextrin
下载PDF
Univariate imputation method for recovering missing data in wastewater treatment process
3
作者 Honggui Han Meiting Sun +2 位作者 Huayun Han Xiaolong Wu Junfei Qiao 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2023年第1期201-210,共10页
High-quality data play a paramount role in monitoring,control,and prediction of wastewater treatment process(WWTP)and can effectively ensure the efficient and stable operation of system.Missing values seriously degrad... High-quality data play a paramount role in monitoring,control,and prediction of wastewater treatment process(WWTP)and can effectively ensure the efficient and stable operation of system.Missing values seriously degrade the accuracy,reliability and completeness of the data quality due to network collapses,connection errors and data transformation failures.In these cases,it is infeasible to recover missing data depending on the correlation with other variables.To tackle this issue,a univariate imputation method(UIM)is proposed for WWTP integrating decomposition method and imputation algorithms.First,the seasonal-trend decomposition based on loess method is utilized to decompose the original time series into the seasonal,trend and remainder components to deal with the nonstationary characteristics of WWTP data.Second,the support vector regression is used to approximate the nonlinearity of the trend and remainder components respectively to provide estimates of its missing values.A self-similarity decomposition is conducted to fill the seasonal component based on its periodic pattern.Third,all the imputed results are merged to obtain the imputation result.Finally,six time series of WWTP are used to evaluate the imputation performance of the proposed UIM by comparing with existing seven methods based on two indicators.The experimental results illustrate that the proposed UIM is effective for WWTP time series under different missing ratios.Therefore,the proposed UIM is a promising method to impute WWTP time series. 展开更多
关键词 Univariate SELF-SIMILARITY waste water ALGORITHM INTEGRATION
下载PDF
Energy,exergy,economic and environmental comprehensive analysis and multi-objective optimization of a sustainable zero liquid discharge integrated process for fixed-bed coal gasification wastewater
4
作者 Yanli Zhang Zhengkun Hou +7 位作者 Dong Yao Xiaomin Qiu Hongru Zhang Peizhe Cui Yinglong Wang Jun Gao Zhaoyou Zhu Limei Zhong 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2023年第6期341-354,共14页
For a long time,China's regional water resource imbalance has restricted the development of coal chemical industry,and it is imperative to achieve zero liquid discharge(ZLD).Therefore,the game relationship between... For a long time,China's regional water resource imbalance has restricted the development of coal chemical industry,and it is imperative to achieve zero liquid discharge(ZLD).Therefore,the game relationship between technical indicators,costs and emissions in ZLD process of fixed-bed coal gasification wastewater treatment process should be explored in detail.According to the accurate model,the simulation for ZLD of fixed-bed coal gasification wastewater treatment process is established,and this process is assessed from the perspective of thermodynamics,economy,and environment.The total energy consumption of ZLD process before optimization is 4.032×10^(8)W.The results of exergy analysis show exergy destruction of ZLD process is 94.55%.For economic and environmental results,the total annual cost is 1.892×10^(7)USD·a^(-1)and the total environmental impact is 4.782×10^(-8).The total energy consumption of the optimal six-step ZLD process based on multi-objective optimization is 4.028×10^(8)W.The CO_(2)content in the treated wastewater is 0.1%.This study will have an important role in promoting the establishment of the ZLD process for coal chemistry industry. 展开更多
关键词 waste water Case study ENERGY EXERGY ECONOMY Environment
下载PDF
Arsenic removal from acidic industrial wastewater by ultrasonic activated phosphorus pentasulfide
5
作者 Bo Yu Guang Fu +6 位作者 Xinpei Li Libo Zhang Jing Li Hongtao Qu Dongbin Wang Qingfeng Dong Mengmeng Zhang 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2023年第8期46-52,共7页
Arsenic is one of the main harmful elements in industrial wastewater.How to remove arsenic has always been one of the research hotspots in academic circles.In the process of arsenic removal by traditional sulfuration,... Arsenic is one of the main harmful elements in industrial wastewater.How to remove arsenic has always been one of the research hotspots in academic circles.In the process of arsenic removal by traditional sulfuration,the use of traditional sulfurizing agent will introduce new metal cations,which will affect the recycling of acid.In this study,phosphorus pentasulfide (P_(2)S_(5)) was used as sulfurizing agent,which hydrolyzed to produce H_(3)PO_(4) and H_(2)S without introducing new metal cations.The effect of ultrasound on arsenic removal by P_(2)S_(5) was studied.Under the action of ultrasound,the utilization of P_(2)S_(5) was improved and the reaction time was shortened.The effects of S/As molar ratio and reaction time on arsenic removal rate were investigated under ultrasonic conditions.Ultrasonic enhanced heat and mass transfer so that the arsenic removal rate of 94.5%could be achieved under the conditions of S/As molar ratio of 2.1:1 and reaction time of 20 min.In the first 60 min,under the same S/As molar ratio and reaction time,the ultrasonic hydrolysis efficiency of P_(2)S_(5) was higher.This is because P_(2)S_(5) forms ([(P_(2)S_(4))])^(2+)under the ultrasonic action,and the structure is damaged,which is easier to be hydrolyzed.In addition,the precipitation after arsenic removal was characterized and analyzed by X-ray diffraction,scanning electron microscope-energy dispersive spectrometer,X-ray fluorescence spectrometer and X-ray photoelectron spectroscopy.Our research avoids the introduction of metal cations in the arsenic removal process,and shortens the reaction time. 展开更多
关键词 Arsenic removal Mass transfer PRECIPITATION waste water Ultrasound
下载PDF
An internal circulation iron-carbon micro-electrolysis reactor for aniline wastewater treatment:Parameter optimization,degradation pathways and mechanism
6
作者 Yanhe Han Han Xu +4 位作者 Lei Zhang Xuejiao Ma Yang Man Zhimin Su Jing Wang 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2023年第11期96-107,共12页
Aniline is a vital industrial raw material.However,highly-toxic aniline wastewater usually deteriorated effluent quality,posed a threat to human health and ecosystem safety.Therefore,this study reported a novel intern... Aniline is a vital industrial raw material.However,highly-toxic aniline wastewater usually deteriorated effluent quality,posed a threat to human health and ecosystem safety.Therefore,this study reported a novel internal circulation iron-carbon micro-electrolysis(ICE)reactor to treat aniline wastewater.The effects of reaction time,pH,aeration rate and iron-carbon(Fe/C)ratio on the removal rate of aniline and the chemical oxygen demand were investigated using single-factor experiments.This process exhibited high aniline degradation performance of approximately 99.86% under optimal operating conditions(reaction time=20 min,pH=3,aeration rate=0.5 m3·h^(-1),and Fe/C=1:2).Based on the experimental results,the response surface method was applied to optimize the aniline removal rate.The Box–Behnken method was used to obtain the interaction effects of three main factors.The result showed that the reaction time had a dominant effect on the removal rate of aniline.The highest aniline removal rate was obtained at pH of 2,aeration rate of 0.5 m^(3)·h^(-1)and reaction time of 30 min.Under optional experimental conditions,the aniline content of effluent was reduced to 3 mg·L^(-1)and the removal rate was as high as 98.24%,within the 95% confidence interval(97.84%-99.32%)of the predicted values.The solution was treated and the reaction intermediates were identified by high-performance liquid chromatography,ultraviolet-visible spectroscopy,Fourier-transform infrared spectroscopy,gas chromatography-mass spectrometry,and ion chromatography.The main intermediates were phenol,benzoquinone,and carboxylic acid.These were used to propose the potential mechanism of aniline degradation in the ICE reactor.The results obtained in this study provide optimized conditions for the treatment of industrial wastewater containing aniline and can strengthen the understanding of the degradation mechanism of iron-carbon micro-electrolysis. 展开更多
关键词 ANILINE Iron-carbon micro-electrolysis Circulating fluidized bed waste water DEGRADATION
下载PDF
Production of Biogas from Olive Mill Waste Waters Treated by Cow Manure
7
作者 Fatma Laabidi Rafik Besbès Bassem Jamoussi 《Green and Sustainable Chemistry》 CAS 2023年第1期62-71,共10页
The olive mill waste waters (OMWW) generated from olive oil extraction is a major environmental concern since they are characterized by their role as a pollutant (high organic and mineral matters) and their pH acid. T... The olive mill waste waters (OMWW) generated from olive oil extraction is a major environmental concern since they are characterized by their role as a pollutant (high organic and mineral matters) and their pH acid. The aim of this study was to valorize (OMWW) by anaerobic fermentation in the presence of cow manure in order to produce biogas and reduce their toxic load. Many tests were carried out by fermenting (OMWW) with polyphenols in the presence of cow manure in thermophile temperatures. The performance of this treatment was valuated through measurements of biogas production and by the determination of different parameters of fermented media (pH, volume of the biogas and polyphenols). 展开更多
关键词 Olive Mill waste waters Anaerobic Fermentation Cow Manure BIOGAS POLYPHENOLS
下载PDF
Synthesis of waterborne polyurethane-humic acid cross-linked biomass porous materials for the adsorption of methylene blue
8
作者 Shanghong Ma Jianbo Qu +4 位作者 Haitao Zhang Xiubin Cui Peng Ye Qingfei Hu Mingzhen Chao 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2024年第3期27-38,共12页
A series of adsorbent materials(WPU-HAx-y)with a three-dimensional porous structure,green sustainability,and excellent performance were prepared and evaluated for the removal of methylene blue using nontoxic and envir... A series of adsorbent materials(WPU-HAx-y)with a three-dimensional porous structure,green sustainability,and excellent performance were prepared and evaluated for the removal of methylene blue using nontoxic and environmentally friendly waterborne polyurethane as the matrix material and humic acid,a biomass material,as the functional material.The newly synthesized adsorbents were characterized by infrared spectroscopy,scanning electron microscopy,specific surface area,and thermogravimetric.The effects of contact time(0-8 h),starting concentration(10-100 mg·L^(-1)),pH(3-11),solution temperature(30-60℃),and coexisting ions(Ca2+,Na+,K+,Mg2+)on the performance were investigated.Pseudo-first-order,pseudo-second-order,elovich,and intra-particle diffusion models were used to analyze the adsorption kinetics;the Langmuir,Freundlich,Temkin,and Dubin-Radushkovich adsorption isotherms were evaluated;and the adsorption behavior of the adsorbent materials was found to be more appropriate for the pseudo-second-order model for chemical pollutant removal than the Langmuir model,which depends on monolayer adsorption.WPU-HA2-3 stood out with a maximum adsorption capacity of 813.0081 mg·g^(-1) fitted to the pseudo-second-order and 309.2832 mg·g^(-1) fitted to the Langmuir model,showing superior adsorption performance and regenerability. 展开更多
关键词 Porous media BIOENERGY Sustainability waste water
下载PDF
STUDY AND SIMULATION OF AN ACTIVATED SLUDGE TREATMENT FOR METHYL VIOLET WASTE WATER
9
作者 张金利 宋宽秀 +1 位作者 王一平 闻建平 《Transactions of Tianjin University》 EI CAS 1998年第2期72-75,共4页
This paper researched a promising biological treatment of methyl violet waste water by methods of activated sludge.Effects of temperature and pH were studied on this process.Kinetic equation ... This paper researched a promising biological treatment of methyl violet waste water by methods of activated sludge.Effects of temperature and pH were studied on this process.Kinetic equation of the substrate biodegradation was investigated in the experimental range.It was studied and simulated that flow within the bubble region of this bioreactor according to the κ ε two fluid equation.Simulation results agree well with experimental data. 展开更多
关键词 bioreactor waste water treatment activated sludge
下载PDF
Study on the Genetic and Physiological Toxicity of Wastewater from a Pharmaceutical Factory Using Root Tip Micronucleus Technology of Vicia faba 被引量:1
10
作者 陈枫 朱铁钢 《Agricultural Science & Technology》 CAS 2013年第7期1041-1043,共3页
ObjectiveThe aim was to assess genetic and physiological toxicity of wastewater from a pharmaceutical factory using root tip micronucleus technology of Vicia faba. MethodThe pollution of wastewater from a pharmaceutic... ObjectiveThe aim was to assess genetic and physiological toxicity of wastewater from a pharmaceutical factory using root tip micronucleus technology of Vicia faba. MethodThe pollution of wastewater from a pharmaceutical factory was detected by using root tip micronucleus technology of Vicia faba, and the genetic and physiological toxicity of the wastewater to Vicia faba was assessed. ResultNon-processed wastewater had an extremely high level of biological toxicity; the cells were unable to live with the wastewater at a high concentration; the cells were able to grow with the wastewater at a low concentration, though the micronucleus ratio was extremely high. The processed wastewater had no significant impact on cell growth, but the micronucleus ratio was extremely high, showing that the processed water also had a high pollution index. ConclusionThe research could provide scientific references for the national treatment of wastewater from a pharmaceutical factory. 展开更多
关键词 waste water from a pharmaceutical factory Root tip of Vicia faba Micronucleus ratio Pollution index Genetic toxicity
下载PDF
Phase equilibria for the pseudo-ternary system(NaCl+Na2SO4+H2O)of coal gasification wastewater at T=(268.15 to 373.15)K 被引量:8
11
作者 Haijiao Lu Jingkang Wang +5 位作者 Jun Yu Yuefeng Wu Ting Wang Ying Bao Dou Ma Hongxun Hao 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2017年第7期955-962,共8页
The pseudo-ternary system(Na Cl + Na_2SO_4+ H_2O) of coal gasification wastewater was studied at T =(268.15 to 373.15) K. The solubility and density of the equilibrium liquid phase were determined by the isothermal so... The pseudo-ternary system(Na Cl + Na_2SO_4+ H_2O) of coal gasification wastewater was studied at T =(268.15 to 373.15) K. The solubility and density of the equilibrium liquid phase were determined by the isothermal solution saturation method. The equilibrium solids were also investigated by the Schreinemaker's method of wet residues and X-ray powder diffraction(XRD). According to the experimental data, the phase diagrams were determined. It was found that there was no significant solubility difference on the Na Cl-rich side between the ternary system(Na Cl + Na_2SO_4+ H_2O) in coal gasification wastewater and in pure water. However, the solubility on the Na_2SO_4-rich side of coal gasification wastewater was apparently higher than that of pure water. The increase in the solubility of Na_2SO_4 was most likely caused by the effects of other impurities apart from Na Cl and Na_2SO_4 in coal gasification wastewater. The measured data and phase equilibrium diagrams can provide fundamental basis for salt recovery in coal gasification wastewater. 展开更多
关键词 Pseudo-ternary system Phase equilibria THERMODYNAMICS waste water Recovery
下载PDF
Recovery of Caprolactam from Waste Water in Caprolactam Production Using Pulsed-sieve-plate Extraction Column 被引量:5
12
作者 刘建青 谢方友 +1 位作者 何潮洪 朱明乔 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2002年第3期371-373,共3页
Recovery of caprolactam from waste water of caprolactam production factory was investigated using benzene as solvent in a small-scale pulsed-sieve-plate column. First, liquid-liquid equilibrium (LLE) data were measure... Recovery of caprolactam from waste water of caprolactam production factory was investigated using benzene as solvent in a small-scale pulsed-sieve-plate column. First, liquid-liquid equilibrium (LLE) data were measured, including water-caprolactam-benzene system at low caprolactam concentrations, and waste water-benzene system. Then, the operating regions and mass transfer of the pulsed-sieve-plate column were measured. Finally, the overall apparent heights of a transfer unit based on continuous phase are correlated in terms of the column operation variables. 展开更多
关键词 pulsed-sieve-plate column extraction e-caprolactam waste water
下载PDF
Researches on the Treatment of Phosphorous Wastewater with Oyster Shells 被引量:7
13
作者 黄绵丽 于岩 吴任平 《Chinese Journal of Structural Chemistry》 SCIE CAS CSCD 2010年第12期1886-1892,共7页
Based on the analysis of adsorptive features of oyster shells,the researches on the treatment of phosphorous wastewater with oyster shells and the effect of temperature on phosphorus removal were carried out.XRD was u... Based on the analysis of adsorptive features of oyster shells,the researches on the treatment of phosphorous wastewater with oyster shells and the effect of temperature on phosphorus removal were carried out.XRD was used to characterize the crystalline phases,and the main component of oyster shells was shown to be CaCO3.When the pretreatment temperature reached 800 ℃,some CaCO3 decomposed into CaO.As the temperature was further raised,CaO increased gradually.Via SEM testing,the oyster shell was a kind of natural porous materials.The pore wall partially collapsed from 550 to 900 ℃.No obvious porous structure was found at 900 ℃.However,without preheating,the oyster shell phosphorous removal material can not adsorb the phosphorus.Pretreatment made calcium activate,thus greatly increasing the absorption of phosphorus. 展开更多
关键词 oyster shell phosphorous waste water adsorptive feature activation
下载PDF
Experimental Study of Wastewater Treatment of Reactive Dye by Phys-Chemistry Method 被引量:15
14
作者 YANG Yan-wu ZHOU Tong-ling +1 位作者 QIAO Qi-cheng CHEN Shuo 《Journal of China University of Mining and Technology》 EI 2007年第1期96-100,共5页
Wastewater, which involves easy-soluble reactive dyes, especially non-degradable dyes, is very difficult to decolor efficiently by normal processes such as coagulation process and biological treatment. The high chroma... Wastewater, which involves easy-soluble reactive dyes, especially non-degradable dyes, is very difficult to decolor efficiently by normal processes such as coagulation process and biological treatment. The high chromaticity se- riously hinders the reuse of reactive dye waste water. In this paper, a new method by bentonite adsorption and coagulation (PAC) is employed for removing color from synthetic dye waste water which contains reactive red K-2G, K-RN blue, K-GR blue, X-3B red, K-GN orange, KB-3G yellow, K-2BP red, K-RN yellow and K-6G yellow. Bentonite pre- treated by 4% CTMAB and milled to 160 order screen is proven to the best decoloring agent. For a 100 mL reactive red K-2G sample (CODcr 400 mg/L, 25 000 chromaticity color), 0.5 g bentonite pretreated and 2.5 mL PAC is enough to decolor wastewater up to 99.92% and the sediment time is short. Non-degradable dyes such as active red X-3B and K-GN orange are declored completely as well. Raw sewage (low chromaticity color) is decolored completely at a ben-tonite dosage of 0.001g. More researches prove the high practical value of this process. 展开更多
关键词 reactive dye wastewater pretreated bentonite chromaticity color waste water reuse
下载PDF
Adsorption of oil from waste water by coal:characteristics and mechanism 被引量:4
15
作者 LI Xiaobing,ZHANG Chunjuan,LIU Jiongtian School of Chemical Engineering and Technology,China University of Mining & Technology,Xuzhou 221116,China 《Mining Science and Technology》 EI CAS 2010年第5期778-781,共4页
The work described here was focused on exploring the potential application of coal to purification of oily waste water.Coal was added to oily waste water as an adsorbent and then removed through a flotation process.Th... The work described here was focused on exploring the potential application of coal to purification of oily waste water.Coal was added to oily waste water as an adsorbent and then removed through a flotation process.This allowed economical and highly efficient separation of oil from the waste water.The absorption time,coal type,coal particle size distribution,pH value and oil concentration were investigated.The results indicate that oil absorption by a coal increases for a period of 1.5 h and then gradually tends toward an equilibrium value.It appears that the absorption capacity of anthracite is more than that of lean coal or lignite,given the same coal particle size distribution.The absorption capacity of a coarse coal fraction is less than that of finer coal,given the same of coal type.The absorption capacity of anthracite decreases slightly as the pH increases from 4 to 9.The adsorption of oil on anthracite follows the Freundlich isothermal adsorption law:given initial oil concentrations of 160.5 or 1023.6 mg/L the absorption capacity was 23.8 or 840.0 mg/g.The absorption mechanism consists of two kinds of absorption,a physical process assisted by a chemical one. 展开更多
关键词 oily wastewater waste water SEPARATION COAL OIL ADSORPTION MECHANISM
下载PDF
The addition of microbes for treating textile wastewater 被引量:4
16
作者 Yang Huifang, Wang Kaimin, Jia Shengfen Qu Angui and Xian HaijunInstitute of Microbiology,Academia Sinica,Beijing 100080,ChinaDesiging Institute of the Ministry of Textile,Beijing,China 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 1991年第1期95-100,共6页
Some strains and culture of bacteria which are able to decolorize dyes and degrade polyvinyl alcohol(PVA) were isolated and selected. A pilot scale facultative anaerobic-aerobic biological process was applied for trea... Some strains and culture of bacteria which are able to decolorize dyes and degrade polyvinyl alcohol(PVA) were isolated and selected. A pilot scale facultative anaerobic-aerobic biological process was applied for treatment of textile wastewater containing dyes and PVA. Activated carbon adsorption was used as a tertiary treatment stage, and residual sludge from clarifier returned to the anaerobic reactor again. The pilot test were carried out with two systems. One was inoculated by acclimated sludge, and the another was adding the mixed culture of dye-decoloring and PVA-degrading bacteria for forming biological films, the latter was observed to be more effective than the former. The test has run normally for ten months with a COD loading of 2.13 kg/m3/day, a BOD5 loading of 0.34 kg/m3/day in anaerobic reactor; a COD loading of 1.71 kg/m3/day, a BOD5 loading 0.44 kg/m3/day in aerobic reactor. The pollutants removal efficiency by adding microbes was about 20% higher than that by acclimated sludge. The average removal efficiency of COD stood about 92%, BOD5 97%, PVA 90% and decolorization 80%. The other parameters of effluent quality are also satisfactory. 展开更多
关键词 addition of microbes facultative anaerobic-aerobic process textile waste water.
下载PDF
THE INVESTIGATION ON PHOTOCATALYTIC TREATMENT OF WASTE WATER CONTAINING PHENOL OVER ZnO 被引量:4
17
作者 康慧敏 康锡惠 《Transactions of Tianjin University》 EI CAS 1996年第2期50+46-49,共5页
This paper adopts a medium pressure mercury lamp as light source and ZnO powder as catalyst to investigate the effect of radioactive wave length, component of phenol ZnO suspension and st... This paper adopts a medium pressure mercury lamp as light source and ZnO powder as catalyst to investigate the effect of radioactive wave length, component of phenol ZnO suspension and stirring method on phenol decomposition rate. The optimized conditions for the phenol decomposition are: (1) Radioactive wave length: 360~420 nm; (2)Phenol concentration in the suspension is less than 200 mg/l; (3)ZnO concentration is 3~8 g/l; (4)pH value is 5~7; (5)Reaction temperature is 25℃~40℃; (6)Agitation at atmosphere. Phenol can decompose in two ways: (1)Reacting with photogenerated cavity; (2)Reacting with ·OH radical. 展开更多
关键词 PHOTOCATALYSIS PHENOL waste water treatment
下载PDF
An Integrated Planning for Rense and Wetland Strategyof Waste Water from Rural Enterprises: A Case Stndy 被引量:2
18
作者 ZHOUQI-XING R.W.BELL 《Pedosphere》 SCIE CAS CSCD 1995年第3期237-243,共7页
A waste water reuse engineering was designed and then operated in Hongshan, a small town in ZhejiangProvince, China, in order to solve pollution and shortage of water resources due to the development of ruralenterpris... A waste water reuse engineering was designed and then operated in Hongshan, a small town in ZhejiangProvince, China, in order to solve pollution and shortage of water resources due to the development of ruralenterprises. The results showed that series-structure design and cycling model were two effective modes ofsaving water and decreasing pollutants into environment, and wetland strategy should be a component partof the integrated planning for waste water reuse of rural enterprises. This case study could provide a basisfor the optimum utilization and pollution avoidance of water resources. 展开更多
关键词 environmental planning waste water reuse wetland strategy
下载PDF
Structure Characterization and Dephosphorization Effect Analysis of Oyster Shell-silica Micropowder Waste Water Dephosphorization Materials 被引量:2
19
作者 赖寿莲 《Chinese Journal of Structural Chemistry》 SCIE CAS CSCD 2010年第1期33-38,共6页
In this work,the effects of pH value of waste water and initial concentration of phosphorus on dephosphorization materials were investigated.The materials were prepared by shaping,sintering and hydrothermal reshaping ... In this work,the effects of pH value of waste water and initial concentration of phosphorus on dephosphorization materials were investigated.The materials were prepared by shaping,sintering and hydrothermal reshaping oyster shell and silica micro-powder.Different concentrations of phosphorus-contained waste water were simulated with potassium dihydrogen phosphate solution,the effect of dephosphorization was tested with phosphomolybdenum blue spectrophotometer method,and the crystal phase and microstructure of materials were characterized by XRD and SEM methods. It was indicated that dephosphorization was completed in 6 h when the initial phosphorus concentration in waste water was lower than 15 mg/L, and the dephosphorization time prolonged as the increase of phosphorus concentration. It was observed that the pH value of waste water influenced dephosphorization significantly, and neutral subalkalic environment favored dephosphorization. When the pH value was 11, the efficiency of dephosphozation was the greatest. For waste water with an initial concentration of 20 mg/L, the dephosphozation rate is close to 100% in8 h. 展开更多
关键词 oyster shell silica micro-powder hydrothermal reaction waste water dephosphorization materials environmental-friendly material
下载PDF
Fouling characteristics of 90° elbow in high salinity wastewater from coal chemical industry 被引量:1
20
作者 Yang Lü Kai Lu +2 位作者 Youxiang Bai Yulong Ma Yongsheng Ren 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2021年第7期143-151,共9页
Due to the high salt content of coal chemical wastewater,pipeline fouling often occurs during wastewater treatment.Fouling will cause the diameter of the pipe to shrink or even block,which is not conducive to the safe... Due to the high salt content of coal chemical wastewater,pipeline fouling often occurs during wastewater treatment.Fouling will cause the diameter of the pipe to shrink or even block,which is not conducive to the safe and stable operation of the wastewater treatment process.In this paper,the experimental device was designed by using FLUENT software and the fouling deposition mechanisms at different flow velocities and different positions in a 90 deg bend were studied.The experimental results show that when the flow velocity is between 0.2 m·s^(-1) and 0.3 m·s^(-1),the thickness of fouling layer was positively correlated with the flow velocity;when the flow velocity is equal to 0.4 m·s^(-1),the formation of fouling is the most serious;when the flow velocity is between 0.4 m·s^(-1) and 0.7 m·s^(-1),the thickness of fouling layer was negative correlation with the flow velocity;with the increase of inlet velocity,the time for sediment point to develop into sediment surface is shortened.The fouling layer is easy to fall off because of the large shear force on the wall surface of the inner bend of the 90°elbow,so the density of sediment at this position is high. 展开更多
关键词 FOULING waste water CFD Inlet velocity
下载PDF
上一页 1 2 4 下一页 到第
使用帮助 返回顶部