期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Experimental investigation on waterproofing performance of segmental joint with double gaskets for shield tunnel 被引量:1
1
作者 Wenqi Ding Qiushi Wang +1 位作者 Yafei Qiao Yuelang Jin 《Underground Space》 SCIE EI 2022年第5期898-910,共13页
The waterproofing capacity of segmental joints is an essential indicator for the long-term service performance of shield tunnels.The segmental joints with double gaskets have been adopted to improve the waterproof per... The waterproofing capacity of segmental joints is an essential indicator for the long-term service performance of shield tunnels.The segmental joints with double gaskets have been adopted to improve the waterproof performance for certain tunnels with high water pressure,especially water-conveyance tunnels.This paper presents a series of waterproofing tests on joints with different settings of double gaskets via an improved test apparatus.Four cases are investigated,including(i)double gaskets with equal high/low waterproof capacity,(ii)the outer gasket with higher waterproof capacity,and(iii)the outer gasket with lower waterproof capacity.Different joint openings are also considered.Moreover,the water pressures at two cavities are continuously monitored to highlight the waterproofing mechanism and failure pattern of double gaskets.The results demonstrate that the gasket with the higher waterproofing capacity dominates the overall waterproofing capacity of joint with double gaskets;only a little enhancement of the waterproofing capacity is found for the joint with the same double gaskets.The waterproofing capacity of joints with double gaskets decreases with the increase of the joint opening.The failure pattern depends on the arrangement of double gaskets,and four stages can be identified during the whole failure process.The advantages of double gaskets in case of joint rotation are also discussed. 展开更多
关键词 Shield tunnel waterproofing performance Segmental joint Double gaskets Experiment Failure pattern
原文传递
Weakening behavior of waterproof performance in joints of shield tunnels under adjacent constructions
2
作者 Huai-Na WU Lei LIU +4 位作者 Yuan LIU Ren-Peng CHEN Hai-Lin WANG Shi-Qiang RUAN Meng FAN 《Frontiers of Structural and Civil Engineering》 SCIE EI CSCD 2023年第6期884-900,共17页
Groundwater leakage in shield tunnels poses a threat to the safety and durability of tunnel structures. Disturbance of adjacent constructions during the operation of shield tunnels frequently occurs in China, leading ... Groundwater leakage in shield tunnels poses a threat to the safety and durability of tunnel structures. Disturbance of adjacent constructions during the operation of shield tunnels frequently occurs in China, leading to deformation of tunnel lining and leakage in joints. Understanding the impact of adjacent constructions on the waterproofing performance of the lining is critical for the protection of shield tunnels. In this study, the weakening behavior of waterproof performance was investigated in the joints of shield tunnels under transverse deformation induced by adjacent construction. First, the relationship between the joint opening and transverse deformation under three typical adjacent constructions (upper loading, upper excavation, and side excavation) was investigated via elaborate numerical simulations. Subsequently, the evolution of the waterproof performance of a common gasket with a joint opening was examined by establishing a coupled Eulerian-Lagrangian model of joint seepage, and a formula describing the relationship between waterproof performance and joint opening was proposed. Finally, the weakening law of waterproofing performance was investigated based on the results of the aforementioned studies. It was determined that the joints with the greatest decline in waterproof performance were located at the tunnel shoulder in the upper loading case, tunnel crown in the upper excavation case, and tunnel shoulder in the side excavation case. When the waterproof performance of these joints decreased to 50% and 30%, the transverse deformations were 60 and 90 mm under upper loading, 90 and 140 mm under upper excavation, and 45 and 70 mm under side excavation, respectively. The results provide a straightforward reference for setting a controlled deformation standard considering the waterproof performance. 展开更多
关键词 shield tunnel waterproof performance horizontal transverse deformation joint opening weakenning behavior
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部