Calibrations were performed for three types of neutron ambient dose equivalent rate meters, i.e., Aloka TPS-451C (Hitachi), KSAR1U.06 (Baltic Scientific Instruments), and Model 12-4 (Ludlum), using a standard field of...Calibrations were performed for three types of neutron ambient dose equivalent rate meters, i.e., Aloka TPS-451C (Hitachi), KSAR1U.06 (Baltic Scientific Instruments), and Model 12-4 (Ludlum), using a standard field of a 241Am–Be source. The measured total neutron ambient dose equivalent rates, H*(10)' tot, were analyzed to obtain the direct neutron ambient dose equivalent rates, H*(10)' dir, using the ISO 8529-2-recommended generalized- fit method, semiempirical fit method, and reducedfitting method (RFM) fit methods. The calibration factor (CF), defined as the ratio between the conventional true value of the neutron ambient dose equivalent rates in a free field, H*(10)' FF, and H*(10)' dir, was evaluated as one of the important characteristics of the neutron meters in the present work. The fitting results show that the H*(10)' dir values of the meters are in good agreement within the theoretical data within 4%. The averaged CFs of the three neutron meters were evaluated as 0:99 ± 0:01, 1:00 ± 0.03;and 0:99 ± 0:08, respectively. The largest standard uncertainty of these values was determined to be approximately 18.47%(k =1). The standard uncertainty of the CFs obtained using the RFM method was less than 4.23%(k=1), which is the smallest uncertainty among the three methods.展开更多
This paper presents the calibration of a neutron dose rate meter and the evaluation of its calibration factors(CFs)in several neutron standard fields(i.e.,two standard fields with bare sources of252Cf and241Am-Be,and ...This paper presents the calibration of a neutron dose rate meter and the evaluation of its calibration factors(CFs)in several neutron standard fields(i.e.,two standard fields with bare sources of252Cf and241Am-Be,and five simulated workplace fields with241Am-Be moderated sources).The calibration in standard fields with bare sources was conducted by following the recommendations of the ISO 8529 standard.The measured total neutron ambient dose equivalent rates,denoted as H*(10)tot,were analyzed to obtain direct components,denoted as H*(10)dir,using a reduced fitting method.The CF was then calculated as the ratio between the conventional true value of the neutron ambient dose equivalent rate in a free field,denoted as H*(10)FF,and the value of H*(10)dir.In contrast,in the simulated workplace neutron fields,the calibration of the neutron dose rate meter was conducted by following the ISO 12789 standard.The CF was calculated as the ratio between the values of H*(10)totmeasured by a standard instrument(i.e.,Bonner sphere spectrometer)and the neutron dose rate meter.The CF values were obtained in the range of 0.88–1.0.The standard uncertainties(k=1)of the CFs were determined to be in the range of approximately 6.6–13.1%.展开更多
In recent years, semiconductor survey meters have been developed and are in increasing demand worldwide. This study determined if it is possible to use the X-ray system installed in each medical facility to calculate ...In recent years, semiconductor survey meters have been developed and are in increasing demand worldwide. This study determined if it is possible to use the X-ray system installed in each medical facility to calculate the time constant of a semiconductor survey meter and confirm the meter’s function. An additional filter was attached to the medical X-ray system to satisfy the standards of N-60 to N-120, more copper plates were added as needed, and the first and second half-value layers were calculated to enable comparisons of the facility’s X-ray system quality with the N-60 to N-120 quality values. Next, we used a medical X-ray system to measure the leakage dose and calculate the time constant of the survey meter. The functionality of the meter was then checked and compared with the energy characteristics of the meter. The experimental results showed that it was possible to use a medical X-ray system to reproduce the N-60 to N-120 radiation quality values and to calculate the time constant from the measured results, assuming actual leakage dosimetry for that radiation quality. We also found that the calibration factor was equivalent to that of the energy characteristics of the survey meter.展开更多
The design scheme for a new kind of long-distance intelligent watt-hour meter is presented. In the system, the control computer communicates with the bank's host computer by the X. 25 network; the built-in embeded se...The design scheme for a new kind of long-distance intelligent watt-hour meter is presented. In the system, the control computer communicates with the bank's host computer by the X. 25 network; the built-in embeded secure access module (ESAM) can verify data by commutation with the intelligent nodes that enhance the security of the data. IC TSS721 is adopted to collect data remotely, and the CPU IC card is used to ensure the the bargaining security and reliability. In addition, the software of the system is introduced.展开更多
There is an imperfection in the accuracy indicators system and the technical parameters system in IEC standards 62053-21 implemented for watt-hour meters currently. This article quoted some parts of OIML MI-003 and R4...There is an imperfection in the accuracy indicators system and the technical parameters system in IEC standards 62053-21 implemented for watt-hour meters currently. This article quoted some parts of OIML MI-003 and R46 contents to provide a reference of the integrity comparison between the accuracy system and technical parameter system. The comparison result shows that the watt-hour meter accuracy technical indicators system of OIML R46 is more integrated. First reason is that it determines all the accuracy (basic error) defining rules just by using the technical parameter I efficiently; secondly, it can solve the contradiction that no error regulation of the range from starting current to minimum current in the process of providing, handing over and checking watt-hour meter products' qualities efficiently. Please pay close attention to the R46 official version which will be released soon, as it is still in the Committee Draft (CD6) stage currently.展开更多
Attitude references are greatly needed for the evaluation and calibration of Inertial Navigation Systems(INSs),which are widely used in gravimeter,marine,and aeronautical navigation.High-accuracy turntable,INS,and Glo...Attitude references are greatly needed for the evaluation and calibration of Inertial Navigation Systems(INSs),which are widely used in gravimeter,marine,and aeronautical navigation.High-accuracy turntable,INS,and Global Navigation Satellite System have been utilized to verify the performance of relatively low-accuracy INS.The accuracy requirement of the attitude reference continuously increases with the rapid improvement of inertial sensors and navigation algorithms.However,the cost of attitude determination system increases rapidly with the increase of attitude accuracy requirement.To solve this limitation,the integration of level meter,INS,and low-cost turntable is proposed to provide level attitude,such as roll and pitch.The turntable is utilized to rotate the INS.An integration model of the level meter and INS is built to estimate the level attitude and reduce the cost of the turntable.The proposed method successfully avoids the dependence on high-accuracy turntables.An observability degree analysis is conducted to improve the level atti-tude accuracy further.The simulation and turntable test results indicate that the proposed method can provide high-accuracy level attitude without high-accuracy INS or turntable and is applicable to error calibration and attitude evaluation of INS.展开更多
基金supported by the Ministry of Science and Technology of Vietnam under Grant 07/HD/DTCB
文摘Calibrations were performed for three types of neutron ambient dose equivalent rate meters, i.e., Aloka TPS-451C (Hitachi), KSAR1U.06 (Baltic Scientific Instruments), and Model 12-4 (Ludlum), using a standard field of a 241Am–Be source. The measured total neutron ambient dose equivalent rates, H*(10)' tot, were analyzed to obtain the direct neutron ambient dose equivalent rates, H*(10)' dir, using the ISO 8529-2-recommended generalized- fit method, semiempirical fit method, and reducedfitting method (RFM) fit methods. The calibration factor (CF), defined as the ratio between the conventional true value of the neutron ambient dose equivalent rates in a free field, H*(10)' FF, and H*(10)' dir, was evaluated as one of the important characteristics of the neutron meters in the present work. The fitting results show that the H*(10)' dir values of the meters are in good agreement within the theoretical data within 4%. The averaged CFs of the three neutron meters were evaluated as 0:99 ± 0:01, 1:00 ± 0.03;and 0:99 ± 0:08, respectively. The largest standard uncertainty of these values was determined to be approximately 18.47%(k =1). The standard uncertainty of the CFs obtained using the RFM method was less than 4.23%(k=1), which is the smallest uncertainty among the three methods.
基金by the National Foundation for Science and Technology Development of Vietnam(No.103.04-2017.37)。
文摘This paper presents the calibration of a neutron dose rate meter and the evaluation of its calibration factors(CFs)in several neutron standard fields(i.e.,two standard fields with bare sources of252Cf and241Am-Be,and five simulated workplace fields with241Am-Be moderated sources).The calibration in standard fields with bare sources was conducted by following the recommendations of the ISO 8529 standard.The measured total neutron ambient dose equivalent rates,denoted as H*(10)tot,were analyzed to obtain direct components,denoted as H*(10)dir,using a reduced fitting method.The CF was then calculated as the ratio between the conventional true value of the neutron ambient dose equivalent rate in a free field,denoted as H*(10)FF,and the value of H*(10)dir.In contrast,in the simulated workplace neutron fields,the calibration of the neutron dose rate meter was conducted by following the ISO 12789 standard.The CF was calculated as the ratio between the values of H*(10)totmeasured by a standard instrument(i.e.,Bonner sphere spectrometer)and the neutron dose rate meter.The CF values were obtained in the range of 0.88–1.0.The standard uncertainties(k=1)of the CFs were determined to be in the range of approximately 6.6–13.1%.
文摘In recent years, semiconductor survey meters have been developed and are in increasing demand worldwide. This study determined if it is possible to use the X-ray system installed in each medical facility to calculate the time constant of a semiconductor survey meter and confirm the meter’s function. An additional filter was attached to the medical X-ray system to satisfy the standards of N-60 to N-120, more copper plates were added as needed, and the first and second half-value layers were calculated to enable comparisons of the facility’s X-ray system quality with the N-60 to N-120 quality values. Next, we used a medical X-ray system to measure the leakage dose and calculate the time constant of the survey meter. The functionality of the meter was then checked and compared with the energy characteristics of the meter. The experimental results showed that it was possible to use a medical X-ray system to reproduce the N-60 to N-120 radiation quality values and to calculate the time constant from the measured results, assuming actual leakage dosimetry for that radiation quality. We also found that the calibration factor was equivalent to that of the energy characteristics of the survey meter.
文摘The design scheme for a new kind of long-distance intelligent watt-hour meter is presented. In the system, the control computer communicates with the bank's host computer by the X. 25 network; the built-in embeded secure access module (ESAM) can verify data by commutation with the intelligent nodes that enhance the security of the data. IC TSS721 is adopted to collect data remotely, and the CPU IC card is used to ensure the the bargaining security and reliability. In addition, the software of the system is introduced.
文摘There is an imperfection in the accuracy indicators system and the technical parameters system in IEC standards 62053-21 implemented for watt-hour meters currently. This article quoted some parts of OIML MI-003 and R46 contents to provide a reference of the integrity comparison between the accuracy system and technical parameter system. The comparison result shows that the watt-hour meter accuracy technical indicators system of OIML R46 is more integrated. First reason is that it determines all the accuracy (basic error) defining rules just by using the technical parameter I efficiently; secondly, it can solve the contradiction that no error regulation of the range from starting current to minimum current in the process of providing, handing over and checking watt-hour meter products' qualities efficiently. Please pay close attention to the R46 official version which will be released soon, as it is still in the Committee Draft (CD6) stage currently.
基金supported by the National Natural Science Foundation of China(No.62073184).
文摘Attitude references are greatly needed for the evaluation and calibration of Inertial Navigation Systems(INSs),which are widely used in gravimeter,marine,and aeronautical navigation.High-accuracy turntable,INS,and Global Navigation Satellite System have been utilized to verify the performance of relatively low-accuracy INS.The accuracy requirement of the attitude reference continuously increases with the rapid improvement of inertial sensors and navigation algorithms.However,the cost of attitude determination system increases rapidly with the increase of attitude accuracy requirement.To solve this limitation,the integration of level meter,INS,and low-cost turntable is proposed to provide level attitude,such as roll and pitch.The turntable is utilized to rotate the INS.An integration model of the level meter and INS is built to estimate the level attitude and reduce the cost of the turntable.The proposed method successfully avoids the dependence on high-accuracy turntables.An observability degree analysis is conducted to improve the level atti-tude accuracy further.The simulation and turntable test results indicate that the proposed method can provide high-accuracy level attitude without high-accuracy INS or turntable and is applicable to error calibration and attitude evaluation of INS.