In this paper we present the recent research results in the field of vision correction and supernormal vision according to the actual measurements of the wave-front aberrations and the corneal surface topography,the c...In this paper we present the recent research results in the field of vision correction and supernormal vision according to the actual measurements of the wave-front aberrations and the corneal surface topography,the clinical detection of the visual function and the laser corneal refractive surgery,and the optimization of the optical system. These include the features of the aberrations of human eye with different pupil sizes,different fields of view and temporal accommodation,the influence of the polychromatic illumination of the visible wavelength on the supernormal vision,and the effect of the existing laser corneal refractive surgery on the wave-front ab-errations of the eye. It is shown that the wave-front aberration of human eye is of temporal variation and of synthesis with multi impact factors. To achieve super-normal vision,an optimum engineering data for the customized laser corneal sur-gery should be firstly acquired,which may involve the dynamic free-form optical surface. Although the myopia can be corrected by the laser in situ keratomileusis(LASIK) in a certain degree,it brings about negative effects under scotopic condi-tions.展开更多
It is reported that the wave-front aberration produced by atmosphere disturbance can be compensated with nonlinear optics phase conjugate technology. The distance of laser propagating in atmosphere is up to 1.27 km aw...It is reported that the wave-front aberration produced by atmosphere disturbance can be compensated with nonlinear optics phase conjugate technology. The distance of laser propagating in atmosphere is up to 1.27 km away. The result shows that SBS phase conjugating beam energy can be focus in a little area on target. And the biggest energy of phase conjugating beam on target is up to 142 mJ.展开更多
AIM:To assess the corneal high-order aberration(HOA)and its correlation with corneal morphological parameters in patients with bilateral keratoconus(KCN)and unilateral Vogt’s striae.METHODS:A total of 168 eyes of 84 ...AIM:To assess the corneal high-order aberration(HOA)and its correlation with corneal morphological parameters in patients with bilateral keratoconus(KCN)and unilateral Vogt’s striae.METHODS:A total of 168 eyes of 84 patients with KCN,whose corneas had definite signs of unilateral Vogt’s striae,were enrolled.Corneal HOA and morphological parameters were measured using Pentacam HR.RESULTS:The corneal morphological parameters between KCN eyes with and without Vogt’s striae were evidently different(P<0.001).The 3rd coma 90°,4th spherical aberration,5th coma 90°,root-mean-square(RMS)(total),and RMS(HOA)in the front,back surfaces and total cornea in KCN eyes with Vogt’s striae were significantly higher than those in KCN eyes without Vogt’s striae(P<0.001).In KCN eyes with Vogt’s striae,the 3rd coma 90°and 4th spherical aberration in the front surface and total cornea were negatively correlated with flat keratometry value(K1),steep keratometry value(K2),mean keratometry value(Km),maximum keratometry value(Kmax),anterior corneal elevation(ACE),and posterior corneal elevation(PCE;P<0.05).The 3rd coma 90°,4th spherical aberration in back surface and RMS(total),RMS(HOA)in the front,back surfaces,total cornea were positively correlated with K1,K2,Km,Kmax,ACE,and PCE(P<0.05).CONCLUSION:Corneal HOA especially vertical coma and spherical aberration may increase when Vogt’s striae appeared in KCN eyes.The scale of increase is significantly related with changes in corneal shapes.展开更多
Recent advances in scanning transmission electron microscopy(STEM)have led to increased development of multidimensional STEM imaging modalities and novel image reconstruction methods.This interest arises because the m...Recent advances in scanning transmission electron microscopy(STEM)have led to increased development of multidimensional STEM imaging modalities and novel image reconstruction methods.This interest arises because the main electron lens in a modern transmission electron microscope usually has a diffraction-space information limit that is significantly better than the real-space resolution of the same lens.This state-of-affairs is sometimes shared by other scattering methods in modern physics and contributes to a broader excitement surrounding multidimensional techniques that scan a probe while recording diffraction-space images,such as ptychography and scanning nano-beam diffraction.However,the contrasting resolution in the two spaces raises the question as to what is limiting their effective performance.Here,we examine this paradox by considering the effects of aberrations in both image and diffraction planes,and likewise separate the contributions of pre-and post-sample aberrations.This consideration provides insight into aberration-measurement techniques and might also indicate improvements for super-resolution techniques.展开更多
We report a novel stimulated Raman scattering(SRS)microscopy technique featuring phase-controlled light focusing and aberration corrections for rapid,deep tissue 3D chemical imaging with subcellular resolution.To acco...We report a novel stimulated Raman scattering(SRS)microscopy technique featuring phase-controlled light focusing and aberration corrections for rapid,deep tissue 3D chemical imaging with subcellular resolution.To accomplish phasecontrolled SRS(PC-SRS),we utilize a single spatial light modulator to electronically tune the axial positioning of both the shortened-length Bessel pump and the focused Gaussian Stokes beams,enabling z-scanning-free optical sectioning in the sample.By incorporating Zernike polynomials into the phase patterns,we simultaneously correct the system aberrations at two separate wavelengths(~240 nm difference),achieving a~3-fold enhancement in signal-to-noise ratio over the uncorrected imaging system.PC-SRS provides>2-fold improvement in imaging depth in various samples(e.g.,polystyrene bead phantoms,porcine brain tissue)as well as achieves SRS 3D imaging speed of~13 Hz per volume for real-time monitoring of Brownian motion of polymer beads in water,superior to conventional point-scanning SRS 3D imaging.We further utilize PC-SRS to observe the metabolic activities of the entire tumor liver in living zebrafish in cellsilent region,unraveling the upregulated metabolism in liver tumor compared to normal liver.This work shows that PCSRS provides unprecedented insights into morpho-chemistry,metabolic and dynamic functioning of live cells and tissue in real-time at the subcellular level.展开更多
Phase aberration correction for medical ultrasound systems has attracted a great deal of attention. Since phased array techniques are now widely employed for industrial non-destructive testing (NDT) applications in ...Phase aberration correction for medical ultrasound systems has attracted a great deal of attention. Since phased array techniques are now widely employed for industrial non-destructive testing (NDT) applications in various fields, the problem of phase aberrations in the process of NDT testing is considered. The technique of cross-covariance for phase aberration correction is presented. The performance of the technique for phase aberration correction is tested by means of echo signals obtained in practical non-destructive testing experiment. The results show that the technique has the better accuracy of phase correction.展开更多
Effects of varieties on the content of tea pigment, L*, a* and b* value of chromatic aberration of black tea infusion was studied. The correlation relationship between content of TF, TR, TB and L*, a*, b* value ...Effects of varieties on the content of tea pigment, L*, a* and b* value of chromatic aberration of black tea infusion was studied. The correlation relationship between content of TF, TR, TB and L*, a*, b* value was extremely significant at P&lt;0.05. Fresh tea leaves with plucking standard of 1 bud and 2 leaves could man-ufacture black tea with higher content of tea pigment, higher a* and b* value but lower L* value, than those of plucking standard of 1 bud and 3 leaves. But the discrepancy of certain parameter of the two plucking standards changed with vari-eties. Varieties’ quality potential could be concealed by improper plucking standards. Six varieties were divided into four groups on the basis of gross tea polyphenols in fresh tea leaves (GTP), consumption of tea polyphenols to gross tea polyphenols ratio (CTP/GTP) and gross tea pigment to consumption of tea polyphenols ratio (GP/CTP). Hybrid performed the very suitability of black tea manufacturing. To en-sure high quality of made black tea, suitable variety should be chosen and reason-able plucking standard also should be taken into consideration.展开更多
Gallbladder cancer(GBC) is infrequent but most lethal biliary tract malignancy characterized by an advanced stage diagnosis and poor survival rates attributed to absence of specific symptoms and effective treatment op...Gallbladder cancer(GBC) is infrequent but most lethal biliary tract malignancy characterized by an advanced stage diagnosis and poor survival rates attributed to absence of specific symptoms and effective treatment options. These necessitate development of early prognostic/predictive markers and novel therapeutic interventions. Micro RNAs(mi RNAs) are small, noncoding RNA molecules that play a key role in tumor biology by functioning like tumor suppressor- or oncogenes and their aberrant expression are associated with the pathogenesis of several neoplasms with overwhelming clinical implications. Since mi RNA signature is tissue specific, here, we focused on current data concerning the mi RNAs abberations in GBC pathogenesis. In GBC, mi RNAs with tumor suppressor activity(mi R-135-5p, mi R-335, mi R-34 a, mi R-26 a, mi R-146b-5p, Mir-218-5p, mi R-1, mi R-145, mir-130a) were found downregulated, while those with oncogenic property(mi R-20 a, mi R-182, mir-155) were upregulated. The expression profile of mi RNAs was significantly associated with GBC prognosis and prediction, and forced over-expression/ inhibition of these mi RNAs was shown to affect tumor growth and development. Further, differential expression of mi RNAs in the blood samples of GBC patients suggest mi RNAs as promising noninvasive biomarker. Thus, mi RNAs represent potential candidate for GBC management, though many hurdles need to be overcome before mi RNAs therapy can be clinically applied to GBC prevention and treatment.展开更多
·AIM: To evaluate the quality of vision in respect to high order aberrations and straylight perception after implantation of an aspheric, aberration correcting,monofocal intraocular lens(IOL).·METHODS: Twent...·AIM: To evaluate the quality of vision in respect to high order aberrations and straylight perception after implantation of an aspheric, aberration correcting,monofocal intraocular lens(IOL).·METHODS: Twenty-one patients(34 eyes) aged 50 to83 y underwent cataract surgery with implantation of an aspheric, aberration correcting IOL(Tecnis ZCB00,Abbott Medical Optics). Three months after surgery they were examined for uncorrected(UDVA) and corrected distance visual acuity(CDVA), contrast sensitivity(CS)under photopic and mesopic conditions with and without glare source, ocular high order aberrations(HOA, Zywave II) and retinal straylight(C-Quant).· RESULTS: Postoperatively, patients achieved a postoperative CDVA of 0.0 log MAR or better in 97.1% of eyes. Mean values of high order abberations were +0.02±0.27(primary coma components) and-0.04 ±0.16(spherical aberration term). Straylight values of the C-Quant were 1.35±0.44 log which is within normal range of age matched phakic patients. The CS measurements under mesopic and photopic conditions in combination with and without glare did not show any statistical significance in the patient group observed(P ≥0.28).· CONCLUSION: The implantation of an aspherical aberration correcting monofocal IOL after cataractsurgery resulted in very low residual higher order aberration(HOA) and normal straylight.展开更多
AIM:To study the relation between higher-order aberrations(HOAs)and contrast sensitivity(CS)in normal eyes among a population of laser in situ keratomileusis(LASIK)candidates.METHODS:In 6629 eyes of 3315 LASIK...AIM:To study the relation between higher-order aberrations(HOAs)and contrast sensitivity(CS)in normal eyes among a population of laser in situ keratomileusis(LASIK)candidates.METHODS:In 6629 eyes of 3315 LASIK candidates,CS were measured under dark environment at the spatial frequencies of 1.5,3,6,12 and 18 cycles per degree(c/d),respectively,using an Optec 6500 visual function tester.Meanwhile,ocular HOAs were measured for a 6.0 mm pupil with a Hartmann-Shack wavefront analyzer.RESULTS:In the study,the subjects with an average spherical equivalent of-4.86±2.07 D were included.HOAs decreased from the third to the sixth order aberrations with predominant aberrations of third-order coma,trefoil and fourth-order spherical aberration.At low and moderate spatial frequencies,CS was negatively correlated with the third-order coma and trefoil aberrations,and decreased with increasing Z31,but increased with increasing Z3-3and Z5-1.At high spatial frequencies,CS decreased with increasing Z3-3and increased with increasing Z5-1.CONCLUSION:At a large pupil size of 6.0 mm,the thirdorder aberrations,but not the total aberrations,are the main factors affecting CS.Vertical coma is negatively correlated with CS.展开更多
AIM: To compare the visual and optical performance of eyes with different corneal spherical aberration (SA) implanted with spherical aberration-free intraocular lens (IOLs). METHODS: Thirty-six patients with different...AIM: To compare the visual and optical performance of eyes with different corneal spherical aberration (SA) implanted with spherical aberration-free intraocular lens (IOLs). METHODS: Thirty-six patients with different corneal SA had phacoemulsification with implantation of spherical aberration-free IOLs. Patients were divided into 3 groups according to the value of preoperative corneal SA. Eyes with corneal SA <0.10 mu m were assigned to group A, those with 0.10 <= corneal SA <0.20 mu m to Group B, and those with 0.20 <= corneal SA <0.35 mu m to Group C. Best-corrected visual acuity (BCVA), contrast sensitivity, corneal SA, total ocular aberrations, and depth of focus were recorded 3 months postoperatively. Distance-corrected near and intermediate visual acuity was studied to measure depth of focus. RESULTS: BCVA and contrast sensitivity were similar between groups. There were no significant differences in distance-corrected near or intermediate visual acuity. Corneal SA was similar before and 3 months after surgery in the 3 groups. With a 5.0mm pupil diameter, root mean square values for total ocular higher-order aberrations (HOAs) were lower in groups A and B than in group C. Total ocular SA was lower in group A than in groups B and C. SA was also lower in group B than in group C. Coma and trefoil were similar between the groups. CONCLUSION: Implantation of spherical aberration-free IOLs in eyes with different corneal SA results in similar visual performance at BCVA, contrast sensitivity and depth of focus.展开更多
Purpose: To verify whether there exists any difference in higher order aberrations after undergoing myopic LASIK (laser in situ keratomileusis) with conventional ablation and customized ablation in different eyes of t...Purpose: To verify whether there exists any difference in higher order aberrations after undergoing myopic LASIK (laser in situ keratomileusis) with conventional ablation and customized ablation in different eyes of the same patient. Methods: This was a prospective randomized study of 54 myopic eyes (27 patients) that underwent LASIK using the Nidek EC-5000 ex-cimer laser system (Nidek, Gamagori, Japan). Topography-guided customized aspheric treatment zone (CATz) was used in the first eye of the patient (study group) and the other eye of the same patient was operated on with conventional ablation (control group). Higher order aberrations [root-mean-square (RMS) in the 5-mm zone] of both groups were observed with the Nidek OPD-Scan aberrometer before and 3 months after LASIK. Preoperative mean refractive error was similar between two eyes of the same patient (t=?0.577, P>0.05). Results: Preoperatively, higher order aberrations (RMS in the 5-mm zone) in the CATz ablation and conventional groups were (0.3600±0.0341) μm and (0.2680±0.1421) μm, respectively. This difference was not statistically significant (t=1.292, P>0.05). Three months after LASIK, higher order aberrations (RMS in 5-mm zone) in the CATz ablation and conventional groups were (0.3627±0.1510) μm and (0.3991±0.1582) μm, respectively. No statistically significant difference was noted between pre- and postoperative higher order aberrations in the CATz group (t=?0.047, P>0.05). However, a statistically significant increase in higher order aberrations was observed after conventional ablation (t=?5.261, P<0.05). A statistically sig-nificant difference was noted in the increase of higher order aberrations after LASIK between groups (t=?2.050, P=0.045). Con-clusion: LASIK with conventional ablation and topography-guided CATz ablation resulted in the same BSCVA (best specta-cle-corrected visual acuity) 3 month after LASIK. Higher order aberrations were increased, but the increase of higher order ab-errations after customized ablation treatment was less than that after conventional ablation.展开更多
AIM: To compare the difference and agreement of KR- lW and iTrace for measurement of high order aberrations.METHODS: KR-1W and iTrace were respectively used in a group of healthy people (40 volunteers, 32 eyes) to...AIM: To compare the difference and agreement of KR- lW and iTrace for measurement of high order aberrations.METHODS: KR-1W and iTrace were respectively used in a group of healthy people (40 volunteers, 32 eyes) to measure the high order aberration (HOA) of corneal, internal and total ocular. The clinical difference and agreement of two instruments were respectively evaluated by paired-samples 1-test and Bland-Altman analysis. RESULTS: The paired-samples t-test showed that the corneal HOA measured by the two instruments had no statistical differences (P〉0.05); but the internal and total ocular HOA had significant statistical differences (P〈 0.05), and the mean results measured by iTrace were higher than that of KR-1W. However, Bland-Altman analysis revealed that the HOA of corneal and internal were all in 95% limits of agreement; and just one point of total ocular HOA was beyond the 95% limits of agreement. CONCLUSION: KR-1W and iTrace were consistent well in the measurement of corneal, internal and total ocular HOA, especially for the cornea.展开更多
AIM: To investigate the relationship between higher- order aberration (HOA) and myopic progression in schoolchildren. ·METHODS: Between April 23 2011 and August 29, 2011 in the children’s myopia outpatient clini...AIM: To investigate the relationship between higher- order aberration (HOA) and myopic progression in schoolchildren. ·METHODS: Between April 23 2011 and August 29, 2011 in the children’s myopia outpatient clinic of the West China Hospital of Sichuan University, 148 eyes of 74 schoolchildren were reviewed. HOAs for a 6 -mm pupil were measured with an aberrometer. Myopic progression rate was defined according to the change in spherical equivalent refraction (SER) divided by the time span (years). Subjects with myopic progression rate of ≥0.50 diopters (D) were classified as the ’fast’group and the subjects with myopic progression rate of 【0.50D were classified as the’slow’group. A retrospective study was conducted to compare HOA between the two groups, using root mean square (RMS) values and Zernike coefficients. ·RESULTS: The RMS values of HOA (t =2.316, P =0.02), HOA without Z 4 0 (t =2.224, P =0.03),third-order aberrations (t’ =2.62, P =0.01), and coma (t’ =2.49, P =0.01) were significantly higher in the fast group than those in the slow group. The individual Zernike coefficients of Z 3 -1 (t = -2.072, P =0.04) and Z 5 1 (Z =-2.627, P =0.01) displayed statistically significant differences between the two groups. Significant correlations were found between the RMS values of HOA (r =0.193, P =0.019), RMS values of HOA without Z 4 0 (r =0.23, P =0.005), RMS values of coma(r =0.235,P =0.004),RMS values of third-order aberrations (r =0.243, P =0.003), and the progression rate. · CONCLUSION: Our results provide evidence of a relationship between HOA and myopic progression. In a future prospective longitudinal study, we aim to verify whether HOA is a risk factor for myopic progression.展开更多
Conformal domes that are shaped to meet aerodynamic requirements can increase range and speed for the host platform. Because these domes typically deviate greatly from spherical surface descriptions, a variety of aber...Conformal domes that are shaped to meet aerodynamic requirements can increase range and speed for the host platform. Because these domes typically deviate greatly from spherical surface descriptions, a variety of aberrations are induced which vary with the field-of-regard (FOR) angle. A system for correcting optical aberrations created by a conformal dome has an outer surface and an inner surface. Optimizing the inner surface is regard as static aberration correction. A deformable mirror is placed at the position of the secondary mirror in the two-mirror all reflective imaging system, which is the dynamic aberration correction. An ellipsoidal MgF2 conformal dome with a fineness ratio of 1.0 is designed as an example. The FOR angle is 0°-30°, and the design wavelength is 4μm. After the optimization at 7 zoom positions by using the design tools Code V, the root-mean-square (RMS) spot size is reduced to approximately 0.99 to 1.48 times the diffraction limit. The design results show that the performances of the conformal optical systems can be greatly improved by the combination of the static correction and the dynamic correction.展开更多
Objective:To investigate the correlation and overlaps between PD-L1 expression and classical genomic aberrations in Chinese lung adenocarcinoma(LADC)patients.Methods:We reviewed 428 consecutive,surgically resected cas...Objective:To investigate the correlation and overlaps between PD-L1 expression and classical genomic aberrations in Chinese lung adenocarcinoma(LADC)patients.Methods:We reviewed 428 consecutive,surgically resected cases of LADC from October 2015 to December 2016 from our center.PD-L1 expression was evaluated based on tumor proportion score(TPS).Correlation and co-occurrence of PD-L1 expression level with those of classical driver genes,such as EGFR,ALK,ROS-1,and KRAS and with clinical variables and disease-free survival(DFS)were analyzed.Results:Seventy of the 428 cases(16.4%)showed TPS≥1%,and 21 cases(4.9%)showed TPS≥50%.PD-L1 positive expression was significantly associated with male gender,smoking,advanced TNM stage,and solid histologic subtype.Both TPS≥1% and ≥50%were correlated with the absence of an EGFR mutation(P<0.001)and the presence of ALK rearrangement(P=0.024).KRAS mutation was associated with TPS≥50%(P=0.035).PD-L1 positivity commonly overlapped with the alterations of classical driver oncogenes(58.5%with TPS≥1% and 42.9% with TPS≥50%).Approximately three-quarters of PD-L1 positive cases co-occurred with classical therapeutic-gene aberrations in cases with stage III/IV cancer or cancer progression.LADC could be divided into four subgroups based on the expression profile of current routine biomarkers for potential therapeutic strategies.Conclusions:PD-L1 expression is not only closely correlated with classic gene alterations but also commonly overlaps with the aberrations of classical driver oncogenes in Chinese LADC patients.These findings provide a useful overview of clinical strategies that rely on the profile of routinely used molecular biomarkers.展开更多
AIM: To compare higher order aberrations in two aspherical intraocular lenses(IOLs): Akreos advanced optics(AO) and Dr. Schmidt Microcrystalline 6125 aspheric anterior surface(MC6125AS) with each other. METHODS: Forty...AIM: To compare higher order aberrations in two aspherical intraocular lenses(IOLs): Akreos advanced optics(AO) and Dr. Schmidt Microcrystalline 6125 aspheric anterior surface(MC6125AS) with each other. METHODS: Forty eyes of 39 patients underwent phacoemulsification and Akreos AO and MC6125 AS were implanted in their eyes in a random manner. Three months post-operatively, higher order aberrations including spherical aberration, coma aberration, and total aberrations were measured and compared.RESULTS: The total aberration was 0.24±0.17 in eyes with Dr. Schmidt and 0.20 ±0.01 in eyes with Akreos AO(P =0.361). The mean of coma aberration was 0.17 ±0.21 and 0.09 ±0.86 in Dr. Schmidt and Akreos lenses,respectively(P =0.825). Total spherical aberration was almost the same in both groups(mean: 0.05, P =0.933).Best corrected visual acuity in Akreos AO(0.10±0.68) and Dr. Schmidt(0.09±0.67) did not differ significantly(P =0.700). CONCLUSION: There is no statistically significant difference in the higher order aberrations between these two aspherical lenses.展开更多
AIM: To record aberrations with a corneal topographic device on the anterior surface of the cornea at different time-points prior to wearing and following discontinued use of rigid gas permeable (RGP) contact lenses. ...AIM: To record aberrations with a corneal topographic device on the anterior surface of the cornea at different time-points prior to wearing and following discontinued use of rigid gas permeable (RGP) contact lenses. The effect of wearing RGP on the anterior surface of the cornea was discussed to provide guidance for clinical refractive error correction.METHODS: The study objects were 24 eyes from 24 patients. All patients underwent identical examination procedures prior to lens use, as well as afterwards, including slit-lamp examination, non-contact tonometer measurement, computer optometry and corneal curvature measurement, subjective refraction test, and corneal topography analysis. The patients wore contact lenses everyday for 1 month and then discontinued. Corneal topographies were recorded at certain time points of 30 minutes, 1 day, 3, 7 and 14 days following use.RESULTS: Total corneal aberration at each time point following discontinued use of RGP contact lenses was less than the time point prior to use. Detailed results were as follows: root mean square (RMS) (pre)=(1.438± 0.328)μm, RMS (30 minutes) =(1.076 ±0.355)μm, RMS (1 day) =(1.362 ±0.402)μm, RMS (3 days) =(1.373 ±0.398)μm, RMS (7 days) =(1.387 ±0.415)μm, and RMS (14 days) = (1.430±0.423)μm. Results showed that at 30 minutes after discontinued use of RGP contact lenses, almost all 2 ndand 3 rd-order aberrations change. Quadrafoil Z10 and spherical Z12 of the 4 th-order were also changed. Alterations to Z5, Z6, and Z12 at 1 day after discontinued use were significant differences compared with the time period prior to RGP use: Z5 and Z6 decreased, and Z12 increased slightly. Z5 and Z6 remained decreased at 3 days after discontinued use, but Z9 and Z10 continued to increase and Z12 returned to levels prior to RGP use. At 14 days after discontinued use, all aberrations were notsignificantly different from the values prior to use.CONCLUSION: The use RGP contact lenses greatly reduced total aberration of the anterior surface of the cornea. Changes to 2 ndand 3 rd-order aberrations (including Z3, Z4, Z5, Z6, Z7, and Z8) were more significant. Following discontinued use of RGP contact lenses, the majority of lower order aberrations returned to original levels in a short period of time. During this process, a transient higher order aberration appeared, but all changes disappeared within 14 days after discontinued use of RGP contact lenses.展开更多
With the evolution of cataract surgery from visual rehabilitation to refractive surgery, aspheric intraocular lenses(IOLs) are being increasingly used in the field of ophthalmology. This increased use can be attribute...With the evolution of cataract surgery from visual rehabilitation to refractive surgery, aspheric intraocular lenses(IOLs) are being increasingly used in the field of ophthalmology. This increased use can be attributed to negative or zero spherical aberrations with unique optical designs, which counteract some of the positive spherical aberrations of the cornea. These alterations reduce the total spherical aberration of human eyes and improve the visual acuity in patients with cataract postoperatively. At present, various types of aspheric IOLs are used worldwide. Although the implantation of aspheric IOL is beneficial to the patients who need correction of spherical aberrations, much controversy is still associated with ocular residual spherical aberrations that facilitate the best visual quality for patients postoperatively. In order to provide reference for future clinical work and scientific research, this report reviews the relationship between the ocular residual spherical aberration of human eyes and visual quality.展开更多
AIM: To study the distribution of ocular higher-order aberrations(HOAs) and mesopic pupil size in individuals screened for refractive surgery. · METHODS: Ocular HOAs and mesopic pupil size were studied in 2 458 e...AIM: To study the distribution of ocular higher-order aberrations(HOAs) and mesopic pupil size in individuals screened for refractive surgery. · METHODS: Ocular HOAs and mesopic pupil size were studied in 2 458 eyes of 1 240 patients with myopia, myopic astigmatism and compound myopic astigmatism and 215 eyes of 110 patients with hyperopia, hyperopic astigmatism and compound hyperopic astigmatism using the Zywave aberrometer (Busch& Lomb). All patients had correctable refractive errors without a history of refractive surgery or underlying diseases. Root-mean-square values of HOAs, total spherical aberration, total coma and mesopic pupil size were analyzed. Ocular HOAs were measured across a ≥ 6.0 mm pupil, and pupil size measurements were performed under the mesopic condition. · RESULTS: The mean values of HOAs, total spherical aberration and total coma in the myopic group were 0.369 μm, ±0.233, 0.133±0.112μm and 0.330±0.188μm, respectively. In the hyperopic group the mean values of HOAs, total spherical aberration and total coma were 0.418μm±0.214, 0.202±0.209μm and 0.343±0.201μm, respectively. Hyperopes showed greater total HOAs (P <0.01) and total spherical aberration (P <0.01) compared to myopes. In age-matched analysis, only the amount of total spherical aberration was higher in the hyperopic group (P =0.05). Mesopic pupil size in the myopic group was larger (P ≤0.05). · CONCLUSION: The results suggested that significant levels of HOAs were found in both groups which are important for planning refractive surgeries on Iranians. There were significantly higher levels of total spherical aberration in hyperopes compared to myopes. Mesopic pupil size was larger in myopic group.展开更多
基金Supported by the National Natural Science Foundation of China (Grant No. 60438030)the Key Research Foundation of Scientific and Technical Committee of Tianjin City of China (Grant No. 033183711)
文摘In this paper we present the recent research results in the field of vision correction and supernormal vision according to the actual measurements of the wave-front aberrations and the corneal surface topography,the clinical detection of the visual function and the laser corneal refractive surgery,and the optimization of the optical system. These include the features of the aberrations of human eye with different pupil sizes,different fields of view and temporal accommodation,the influence of the polychromatic illumination of the visible wavelength on the supernormal vision,and the effect of the existing laser corneal refractive surgery on the wave-front ab-errations of the eye. It is shown that the wave-front aberration of human eye is of temporal variation and of synthesis with multi impact factors. To achieve super-normal vision,an optimum engineering data for the customized laser corneal sur-gery should be firstly acquired,which may involve the dynamic free-form optical surface. Although the myopia can be corrected by the laser in situ keratomileusis(LASIK) in a certain degree,it brings about negative effects under scotopic condi-tions.
基金This work was supported by the National Natural Science Foundation of China under Grant No. 60178019. Y. Ju's e-mail address is juyl@hit.edu.cn.
文摘It is reported that the wave-front aberration produced by atmosphere disturbance can be compensated with nonlinear optics phase conjugate technology. The distance of laser propagating in atmosphere is up to 1.27 km away. The result shows that SBS phase conjugating beam energy can be focus in a little area on target. And the biggest energy of phase conjugating beam on target is up to 142 mJ.
基金Supported by Xi’an Health Committee Research Projects(No.2023yb14)Shaanxi Province Natural Science Basic Research Project(No.2024JC-YBMS-623)Shaanxi Province Science and Technology Plan Project(No.2024SFYBXM-331).
文摘AIM:To assess the corneal high-order aberration(HOA)and its correlation with corneal morphological parameters in patients with bilateral keratoconus(KCN)and unilateral Vogt’s striae.METHODS:A total of 168 eyes of 84 patients with KCN,whose corneas had definite signs of unilateral Vogt’s striae,were enrolled.Corneal HOA and morphological parameters were measured using Pentacam HR.RESULTS:The corneal morphological parameters between KCN eyes with and without Vogt’s striae were evidently different(P<0.001).The 3rd coma 90°,4th spherical aberration,5th coma 90°,root-mean-square(RMS)(total),and RMS(HOA)in the front,back surfaces and total cornea in KCN eyes with Vogt’s striae were significantly higher than those in KCN eyes without Vogt’s striae(P<0.001).In KCN eyes with Vogt’s striae,the 3rd coma 90°and 4th spherical aberration in the front surface and total cornea were negatively correlated with flat keratometry value(K1),steep keratometry value(K2),mean keratometry value(Km),maximum keratometry value(Kmax),anterior corneal elevation(ACE),and posterior corneal elevation(PCE;P<0.05).The 3rd coma 90°,4th spherical aberration in back surface and RMS(total),RMS(HOA)in the front,back surfaces,total cornea were positively correlated with K1,K2,Km,Kmax,ACE,and PCE(P<0.05).CONCLUSION:Corneal HOA especially vertical coma and spherical aberration may increase when Vogt’s striae appeared in KCN eyes.The scale of increase is significantly related with changes in corneal shapes.
基金the U.S.Department of Energy,Office of Basic Energy Sciences(DOE-BES),Division of Materials Sciences and Engineering under contract ERKCS89.We acknowledge support for 4D-STEM performed as part of user proposal at the Center for Nanophase Materials Sciences(CNMS),which is a US Department of Energy,Office of Science,User Facility.Microscopy performed using instrumentation within ORNL’s Materials Characterization Core provided by UTBattelle,LLC,under Contract No.DE-AC05-00OR22725 with the DOE and sponsored by the Laboratory Directed Research and Development Program of Oak Ridge National Laboratory,managed by UT-Battelle,LLC,for the U.S.Department of Energy.
文摘Recent advances in scanning transmission electron microscopy(STEM)have led to increased development of multidimensional STEM imaging modalities and novel image reconstruction methods.This interest arises because the main electron lens in a modern transmission electron microscope usually has a diffraction-space information limit that is significantly better than the real-space resolution of the same lens.This state-of-affairs is sometimes shared by other scattering methods in modern physics and contributes to a broader excitement surrounding multidimensional techniques that scan a probe while recording diffraction-space images,such as ptychography and scanning nano-beam diffraction.However,the contrasting resolution in the two spaces raises the question as to what is limiting their effective performance.Here,we examine this paradox by considering the effects of aberrations in both image and diffraction planes,and likewise separate the contributions of pre-and post-sample aberrations.This consideration provides insight into aberration-measurement techniques and might also indicate improvements for super-resolution techniques.
基金supported by the Academic Research Fund(AcRF)from the Ministry of Education(MOE)(Tier 2(A-8000117-01-00)Tier 1(R397-000-334-114,R397-000-371-114,and R397-000-378-114)2024 Tsinghua-NUS Joint Research Initiative Fund,and the National Medical Research Council(NMRC)(A-0009502-01-00,and A-8001143-00-00),Singapore.
文摘We report a novel stimulated Raman scattering(SRS)microscopy technique featuring phase-controlled light focusing and aberration corrections for rapid,deep tissue 3D chemical imaging with subcellular resolution.To accomplish phasecontrolled SRS(PC-SRS),we utilize a single spatial light modulator to electronically tune the axial positioning of both the shortened-length Bessel pump and the focused Gaussian Stokes beams,enabling z-scanning-free optical sectioning in the sample.By incorporating Zernike polynomials into the phase patterns,we simultaneously correct the system aberrations at two separate wavelengths(~240 nm difference),achieving a~3-fold enhancement in signal-to-noise ratio over the uncorrected imaging system.PC-SRS provides>2-fold improvement in imaging depth in various samples(e.g.,polystyrene bead phantoms,porcine brain tissue)as well as achieves SRS 3D imaging speed of~13 Hz per volume for real-time monitoring of Brownian motion of polymer beads in water,superior to conventional point-scanning SRS 3D imaging.We further utilize PC-SRS to observe the metabolic activities of the entire tumor liver in living zebrafish in cellsilent region,unraveling the upregulated metabolism in liver tumor compared to normal liver.This work shows that PCSRS provides unprecedented insights into morpho-chemistry,metabolic and dynamic functioning of live cells and tissue in real-time at the subcellular level.
基金National Natural Science Foundation of China(No.61201412)Ntural Science Foundation of Shanxi Province(No.2012021011-5)
文摘Phase aberration correction for medical ultrasound systems has attracted a great deal of attention. Since phased array techniques are now widely employed for industrial non-destructive testing (NDT) applications in various fields, the problem of phase aberrations in the process of NDT testing is considered. The technique of cross-covariance for phase aberration correction is presented. The performance of the technique for phase aberration correction is tested by means of echo signals obtained in practical non-destructive testing experiment. The results show that the technique has the better accuracy of phase correction.
基金Supported by Black Tea Team of Department of National Tea Industry and Technology System(CARS-23)Key Team of Department of Agriculture of Zhejiang Province(2011006)~~
文摘Effects of varieties on the content of tea pigment, L*, a* and b* value of chromatic aberration of black tea infusion was studied. The correlation relationship between content of TF, TR, TB and L*, a*, b* value was extremely significant at P&lt;0.05. Fresh tea leaves with plucking standard of 1 bud and 2 leaves could man-ufacture black tea with higher content of tea pigment, higher a* and b* value but lower L* value, than those of plucking standard of 1 bud and 3 leaves. But the discrepancy of certain parameter of the two plucking standards changed with vari-eties. Varieties’ quality potential could be concealed by improper plucking standards. Six varieties were divided into four groups on the basis of gross tea polyphenols in fresh tea leaves (GTP), consumption of tea polyphenols to gross tea polyphenols ratio (CTP/GTP) and gross tea pigment to consumption of tea polyphenols ratio (GP/CTP). Hybrid performed the very suitability of black tea manufacturing. To en-sure high quality of made black tea, suitable variety should be chosen and reason-able plucking standard also should be taken into consideration.
文摘Gallbladder cancer(GBC) is infrequent but most lethal biliary tract malignancy characterized by an advanced stage diagnosis and poor survival rates attributed to absence of specific symptoms and effective treatment options. These necessitate development of early prognostic/predictive markers and novel therapeutic interventions. Micro RNAs(mi RNAs) are small, noncoding RNA molecules that play a key role in tumor biology by functioning like tumor suppressor- or oncogenes and their aberrant expression are associated with the pathogenesis of several neoplasms with overwhelming clinical implications. Since mi RNA signature is tissue specific, here, we focused on current data concerning the mi RNAs abberations in GBC pathogenesis. In GBC, mi RNAs with tumor suppressor activity(mi R-135-5p, mi R-335, mi R-34 a, mi R-26 a, mi R-146b-5p, Mir-218-5p, mi R-1, mi R-145, mir-130a) were found downregulated, while those with oncogenic property(mi R-20 a, mi R-182, mir-155) were upregulated. The expression profile of mi RNAs was significantly associated with GBC prognosis and prediction, and forced over-expression/ inhibition of these mi RNAs was shown to affect tumor growth and development. Further, differential expression of mi RNAs in the blood samples of GBC patients suggest mi RNAs as promising noninvasive biomarker. Thus, mi RNAs represent potential candidate for GBC management, though many hurdles need to be overcome before mi RNAs therapy can be clinically applied to GBC prevention and treatment.
文摘·AIM: To evaluate the quality of vision in respect to high order aberrations and straylight perception after implantation of an aspheric, aberration correcting,monofocal intraocular lens(IOL).·METHODS: Twenty-one patients(34 eyes) aged 50 to83 y underwent cataract surgery with implantation of an aspheric, aberration correcting IOL(Tecnis ZCB00,Abbott Medical Optics). Three months after surgery they were examined for uncorrected(UDVA) and corrected distance visual acuity(CDVA), contrast sensitivity(CS)under photopic and mesopic conditions with and without glare source, ocular high order aberrations(HOA, Zywave II) and retinal straylight(C-Quant).· RESULTS: Postoperatively, patients achieved a postoperative CDVA of 0.0 log MAR or better in 97.1% of eyes. Mean values of high order abberations were +0.02±0.27(primary coma components) and-0.04 ±0.16(spherical aberration term). Straylight values of the C-Quant were 1.35±0.44 log which is within normal range of age matched phakic patients. The CS measurements under mesopic and photopic conditions in combination with and without glare did not show any statistical significance in the patient group observed(P ≥0.28).· CONCLUSION: The implantation of an aspherical aberration correcting monofocal IOL after cataractsurgery resulted in very low residual higher order aberration(HOA) and normal straylight.
文摘AIM:To study the relation between higher-order aberrations(HOAs)and contrast sensitivity(CS)in normal eyes among a population of laser in situ keratomileusis(LASIK)candidates.METHODS:In 6629 eyes of 3315 LASIK candidates,CS were measured under dark environment at the spatial frequencies of 1.5,3,6,12 and 18 cycles per degree(c/d),respectively,using an Optec 6500 visual function tester.Meanwhile,ocular HOAs were measured for a 6.0 mm pupil with a Hartmann-Shack wavefront analyzer.RESULTS:In the study,the subjects with an average spherical equivalent of-4.86±2.07 D were included.HOAs decreased from the third to the sixth order aberrations with predominant aberrations of third-order coma,trefoil and fourth-order spherical aberration.At low and moderate spatial frequencies,CS was negatively correlated with the third-order coma and trefoil aberrations,and decreased with increasing Z31,but increased with increasing Z3-3and Z5-1.At high spatial frequencies,CS decreased with increasing Z3-3and increased with increasing Z5-1.CONCLUSION:At a large pupil size of 6.0 mm,the thirdorder aberrations,but not the total aberrations,are the main factors affecting CS.Vertical coma is negatively correlated with CS.
基金Science and Technology of Wenzhou City,China(No.Y20100040)
文摘AIM: To compare the visual and optical performance of eyes with different corneal spherical aberration (SA) implanted with spherical aberration-free intraocular lens (IOLs). METHODS: Thirty-six patients with different corneal SA had phacoemulsification with implantation of spherical aberration-free IOLs. Patients were divided into 3 groups according to the value of preoperative corneal SA. Eyes with corneal SA <0.10 mu m were assigned to group A, those with 0.10 <= corneal SA <0.20 mu m to Group B, and those with 0.20 <= corneal SA <0.35 mu m to Group C. Best-corrected visual acuity (BCVA), contrast sensitivity, corneal SA, total ocular aberrations, and depth of focus were recorded 3 months postoperatively. Distance-corrected near and intermediate visual acuity was studied to measure depth of focus. RESULTS: BCVA and contrast sensitivity were similar between groups. There were no significant differences in distance-corrected near or intermediate visual acuity. Corneal SA was similar before and 3 months after surgery in the 3 groups. With a 5.0mm pupil diameter, root mean square values for total ocular higher-order aberrations (HOAs) were lower in groups A and B than in group C. Total ocular SA was lower in group A than in groups B and C. SA was also lower in group B than in group C. Coma and trefoil were similar between the groups. CONCLUSION: Implantation of spherical aberration-free IOLs in eyes with different corneal SA results in similar visual performance at BCVA, contrast sensitivity and depth of focus.
文摘Purpose: To verify whether there exists any difference in higher order aberrations after undergoing myopic LASIK (laser in situ keratomileusis) with conventional ablation and customized ablation in different eyes of the same patient. Methods: This was a prospective randomized study of 54 myopic eyes (27 patients) that underwent LASIK using the Nidek EC-5000 ex-cimer laser system (Nidek, Gamagori, Japan). Topography-guided customized aspheric treatment zone (CATz) was used in the first eye of the patient (study group) and the other eye of the same patient was operated on with conventional ablation (control group). Higher order aberrations [root-mean-square (RMS) in the 5-mm zone] of both groups were observed with the Nidek OPD-Scan aberrometer before and 3 months after LASIK. Preoperative mean refractive error was similar between two eyes of the same patient (t=?0.577, P>0.05). Results: Preoperatively, higher order aberrations (RMS in the 5-mm zone) in the CATz ablation and conventional groups were (0.3600±0.0341) μm and (0.2680±0.1421) μm, respectively. This difference was not statistically significant (t=1.292, P>0.05). Three months after LASIK, higher order aberrations (RMS in 5-mm zone) in the CATz ablation and conventional groups were (0.3627±0.1510) μm and (0.3991±0.1582) μm, respectively. No statistically significant difference was noted between pre- and postoperative higher order aberrations in the CATz group (t=?0.047, P>0.05). However, a statistically significant increase in higher order aberrations was observed after conventional ablation (t=?5.261, P<0.05). A statistically sig-nificant difference was noted in the increase of higher order aberrations after LASIK between groups (t=?2.050, P=0.045). Con-clusion: LASIK with conventional ablation and topography-guided CATz ablation resulted in the same BSCVA (best specta-cle-corrected visual acuity) 3 month after LASIK. Higher order aberrations were increased, but the increase of higher order ab-errations after customized ablation treatment was less than that after conventional ablation.
文摘AIM: To compare the difference and agreement of KR- lW and iTrace for measurement of high order aberrations.METHODS: KR-1W and iTrace were respectively used in a group of healthy people (40 volunteers, 32 eyes) to measure the high order aberration (HOA) of corneal, internal and total ocular. The clinical difference and agreement of two instruments were respectively evaluated by paired-samples 1-test and Bland-Altman analysis. RESULTS: The paired-samples t-test showed that the corneal HOA measured by the two instruments had no statistical differences (P〉0.05); but the internal and total ocular HOA had significant statistical differences (P〈 0.05), and the mean results measured by iTrace were higher than that of KR-1W. However, Bland-Altman analysis revealed that the HOA of corneal and internal were all in 95% limits of agreement; and just one point of total ocular HOA was beyond the 95% limits of agreement. CONCLUSION: KR-1W and iTrace were consistent well in the measurement of corneal, internal and total ocular HOA, especially for the cornea.
基金Sichuan Province Scientific Plan Project,China (No. 2010SZ0087)
文摘AIM: To investigate the relationship between higher- order aberration (HOA) and myopic progression in schoolchildren. ·METHODS: Between April 23 2011 and August 29, 2011 in the children’s myopia outpatient clinic of the West China Hospital of Sichuan University, 148 eyes of 74 schoolchildren were reviewed. HOAs for a 6 -mm pupil were measured with an aberrometer. Myopic progression rate was defined according to the change in spherical equivalent refraction (SER) divided by the time span (years). Subjects with myopic progression rate of ≥0.50 diopters (D) were classified as the ’fast’group and the subjects with myopic progression rate of 【0.50D were classified as the’slow’group. A retrospective study was conducted to compare HOA between the two groups, using root mean square (RMS) values and Zernike coefficients. ·RESULTS: The RMS values of HOA (t =2.316, P =0.02), HOA without Z 4 0 (t =2.224, P =0.03),third-order aberrations (t’ =2.62, P =0.01), and coma (t’ =2.49, P =0.01) were significantly higher in the fast group than those in the slow group. The individual Zernike coefficients of Z 3 -1 (t = -2.072, P =0.04) and Z 5 1 (Z =-2.627, P =0.01) displayed statistically significant differences between the two groups. Significant correlations were found between the RMS values of HOA (r =0.193, P =0.019), RMS values of HOA without Z 4 0 (r =0.23, P =0.005), RMS values of coma(r =0.235,P =0.004),RMS values of third-order aberrations (r =0.243, P =0.003), and the progression rate. · CONCLUSION: Our results provide evidence of a relationship between HOA and myopic progression. In a future prospective longitudinal study, we aim to verify whether HOA is a risk factor for myopic progression.
基金supported by the National High Technology Research and Development Program of China (Grant No 2006AA012339)
文摘Conformal domes that are shaped to meet aerodynamic requirements can increase range and speed for the host platform. Because these domes typically deviate greatly from spherical surface descriptions, a variety of aberrations are induced which vary with the field-of-regard (FOR) angle. A system for correcting optical aberrations created by a conformal dome has an outer surface and an inner surface. Optimizing the inner surface is regard as static aberration correction. A deformable mirror is placed at the position of the secondary mirror in the two-mirror all reflective imaging system, which is the dynamic aberration correction. An ellipsoidal MgF2 conformal dome with a fineness ratio of 1.0 is designed as an example. The FOR angle is 0°-30°, and the design wavelength is 4μm. After the optimization at 7 zoom positions by using the design tools Code V, the root-mean-square (RMS) spot size is reduced to approximately 0.99 to 1.48 times the diffraction limit. The design results show that the performances of the conformal optical systems can be greatly improved by the combination of the static correction and the dynamic correction.
基金supported by the National Natural Science Foundation of China (Grant No. 81871860)
文摘Objective:To investigate the correlation and overlaps between PD-L1 expression and classical genomic aberrations in Chinese lung adenocarcinoma(LADC)patients.Methods:We reviewed 428 consecutive,surgically resected cases of LADC from October 2015 to December 2016 from our center.PD-L1 expression was evaluated based on tumor proportion score(TPS).Correlation and co-occurrence of PD-L1 expression level with those of classical driver genes,such as EGFR,ALK,ROS-1,and KRAS and with clinical variables and disease-free survival(DFS)were analyzed.Results:Seventy of the 428 cases(16.4%)showed TPS≥1%,and 21 cases(4.9%)showed TPS≥50%.PD-L1 positive expression was significantly associated with male gender,smoking,advanced TNM stage,and solid histologic subtype.Both TPS≥1% and ≥50%were correlated with the absence of an EGFR mutation(P<0.001)and the presence of ALK rearrangement(P=0.024).KRAS mutation was associated with TPS≥50%(P=0.035).PD-L1 positivity commonly overlapped with the alterations of classical driver oncogenes(58.5%with TPS≥1% and 42.9% with TPS≥50%).Approximately three-quarters of PD-L1 positive cases co-occurred with classical therapeutic-gene aberrations in cases with stage III/IV cancer or cancer progression.LADC could be divided into four subgroups based on the expression profile of current routine biomarkers for potential therapeutic strategies.Conclusions:PD-L1 expression is not only closely correlated with classic gene alterations but also commonly overlaps with the aberrations of classical driver oncogenes in Chinese LADC patients.These findings provide a useful overview of clinical strategies that rely on the profile of routinely used molecular biomarkers.
文摘AIM: To compare higher order aberrations in two aspherical intraocular lenses(IOLs): Akreos advanced optics(AO) and Dr. Schmidt Microcrystalline 6125 aspheric anterior surface(MC6125AS) with each other. METHODS: Forty eyes of 39 patients underwent phacoemulsification and Akreos AO and MC6125 AS were implanted in their eyes in a random manner. Three months post-operatively, higher order aberrations including spherical aberration, coma aberration, and total aberrations were measured and compared.RESULTS: The total aberration was 0.24±0.17 in eyes with Dr. Schmidt and 0.20 ±0.01 in eyes with Akreos AO(P =0.361). The mean of coma aberration was 0.17 ±0.21 and 0.09 ±0.86 in Dr. Schmidt and Akreos lenses,respectively(P =0.825). Total spherical aberration was almost the same in both groups(mean: 0.05, P =0.933).Best corrected visual acuity in Akreos AO(0.10±0.68) and Dr. Schmidt(0.09±0.67) did not differ significantly(P =0.700). CONCLUSION: There is no statistically significant difference in the higher order aberrations between these two aspherical lenses.
文摘AIM: To record aberrations with a corneal topographic device on the anterior surface of the cornea at different time-points prior to wearing and following discontinued use of rigid gas permeable (RGP) contact lenses. The effect of wearing RGP on the anterior surface of the cornea was discussed to provide guidance for clinical refractive error correction.METHODS: The study objects were 24 eyes from 24 patients. All patients underwent identical examination procedures prior to lens use, as well as afterwards, including slit-lamp examination, non-contact tonometer measurement, computer optometry and corneal curvature measurement, subjective refraction test, and corneal topography analysis. The patients wore contact lenses everyday for 1 month and then discontinued. Corneal topographies were recorded at certain time points of 30 minutes, 1 day, 3, 7 and 14 days following use.RESULTS: Total corneal aberration at each time point following discontinued use of RGP contact lenses was less than the time point prior to use. Detailed results were as follows: root mean square (RMS) (pre)=(1.438± 0.328)μm, RMS (30 minutes) =(1.076 ±0.355)μm, RMS (1 day) =(1.362 ±0.402)μm, RMS (3 days) =(1.373 ±0.398)μm, RMS (7 days) =(1.387 ±0.415)μm, and RMS (14 days) = (1.430±0.423)μm. Results showed that at 30 minutes after discontinued use of RGP contact lenses, almost all 2 ndand 3 rd-order aberrations change. Quadrafoil Z10 and spherical Z12 of the 4 th-order were also changed. Alterations to Z5, Z6, and Z12 at 1 day after discontinued use were significant differences compared with the time period prior to RGP use: Z5 and Z6 decreased, and Z12 increased slightly. Z5 and Z6 remained decreased at 3 days after discontinued use, but Z9 and Z10 continued to increase and Z12 returned to levels prior to RGP use. At 14 days after discontinued use, all aberrations were notsignificantly different from the values prior to use.CONCLUSION: The use RGP contact lenses greatly reduced total aberration of the anterior surface of the cornea. Changes to 2 ndand 3 rd-order aberrations (including Z3, Z4, Z5, Z6, Z7, and Z8) were more significant. Following discontinued use of RGP contact lenses, the majority of lower order aberrations returned to original levels in a short period of time. During this process, a transient higher order aberration appeared, but all changes disappeared within 14 days after discontinued use of RGP contact lenses.
文摘With the evolution of cataract surgery from visual rehabilitation to refractive surgery, aspheric intraocular lenses(IOLs) are being increasingly used in the field of ophthalmology. This increased use can be attributed to negative or zero spherical aberrations with unique optical designs, which counteract some of the positive spherical aberrations of the cornea. These alterations reduce the total spherical aberration of human eyes and improve the visual acuity in patients with cataract postoperatively. At present, various types of aspheric IOLs are used worldwide. Although the implantation of aspheric IOL is beneficial to the patients who need correction of spherical aberrations, much controversy is still associated with ocular residual spherical aberrations that facilitate the best visual quality for patients postoperatively. In order to provide reference for future clinical work and scientific research, this report reviews the relationship between the ocular residual spherical aberration of human eyes and visual quality.
文摘AIM: To study the distribution of ocular higher-order aberrations(HOAs) and mesopic pupil size in individuals screened for refractive surgery. · METHODS: Ocular HOAs and mesopic pupil size were studied in 2 458 eyes of 1 240 patients with myopia, myopic astigmatism and compound myopic astigmatism and 215 eyes of 110 patients with hyperopia, hyperopic astigmatism and compound hyperopic astigmatism using the Zywave aberrometer (Busch& Lomb). All patients had correctable refractive errors without a history of refractive surgery or underlying diseases. Root-mean-square values of HOAs, total spherical aberration, total coma and mesopic pupil size were analyzed. Ocular HOAs were measured across a ≥ 6.0 mm pupil, and pupil size measurements were performed under the mesopic condition. · RESULTS: The mean values of HOAs, total spherical aberration and total coma in the myopic group were 0.369 μm, ±0.233, 0.133±0.112μm and 0.330±0.188μm, respectively. In the hyperopic group the mean values of HOAs, total spherical aberration and total coma were 0.418μm±0.214, 0.202±0.209μm and 0.343±0.201μm, respectively. Hyperopes showed greater total HOAs (P <0.01) and total spherical aberration (P <0.01) compared to myopes. In age-matched analysis, only the amount of total spherical aberration was higher in the hyperopic group (P =0.05). Mesopic pupil size in the myopic group was larger (P ≤0.05). · CONCLUSION: The results suggested that significant levels of HOAs were found in both groups which are important for planning refractive surgeries on Iranians. There were significantly higher levels of total spherical aberration in hyperopes compared to myopes. Mesopic pupil size was larger in myopic group.