This meta-analysis compared the therapeutic effect of cable pin system(CPS) with K-wire tension band(KTB) in the treatment of patella fractures among Chinese Han population. The databases of PubM ed, Cochrane libr...This meta-analysis compared the therapeutic effect of cable pin system(CPS) with K-wire tension band(KTB) in the treatment of patella fractures among Chinese Han population. The databases of PubM ed, Cochrane library, China National Knowledge Infrastructure(CNKI), Chinese Wan Fang and Chinese VIP were searched for studies on CPS versus KTB in the treatment of patella fractures among Chinese Han population. Literatures were screened according to the inclusion and exclusion criteria. The quality of the studies was assessed, and meta-analysis was performed using the Cochrane Collaboration's REVMAN 5.3 software. A total of 932 patients from 15 studies were included in this meta-analysis(426 fractures treated with CPS and 506 fractures treated with KTB). There were significant differences in duration of hospital stay [mean difference(MD)=–1.07; 95% confidence interval(CI): –1.71 to –0.43], fracture healing time(MD=–1.23; 95% CI: –1.68 to –0.77), flexion degree of knee joint at 6 th month after operation(MD=14.82; 95% CI: 10.93 to 18.71), incidence of postoperative complication [risk ratio(RR)=0.16; 95% CI: 0.09 to 0.27] and excellent-good rate of B?stman score(RR=1.09; 95% CI: 1.03 to 1.16) between the CPS group and KTB group, while no significant difference was found in operative time between the two groups(MD=–4.52; 95% CI: –11.70 to 2.67). For the treatment of patella fractures among Chinese Han population, limited evidence suggests that the CPS is more suitable than the KTB when considering the hospital stay, fracture healing time, flexion degree of knee at 6 th month after operation, incidence of postoperative complication and excellent-good rate of B?stman joint score. Due to the limitation of high quality evidence and sample size, more large-scale randomized controlled trials are needed to validate the findings in the future.展开更多
Based on the analysis of the mechanism of wire tension control by using torque motors in the multi-wire saw machining process, some mathematical models of a tension control system are studied, and an adaptive algo- ri...Based on the analysis of the mechanism of wire tension control by using torque motors in the multi-wire saw machining process, some mathematical models of a tension control system are studied, and an adaptive algo- rithm is designed for controlling the wire tension. In this algorithm of tension control, the rotation speeds and waving angle of motors are measured and fed back to the controller, and the NLMS( normalized least mean squares) algorithm is used to calculate the adaptive correction value and control the wire tension accurately. The computer simulation results in Matlab software validate the high accuracy for controlling the system of the wire tension with the NLMS algorithm in the multi-wire saw machining process.展开更多
WEDM is used in machining conductive materials where it is required to obtained complicated and intricate shapes with high accuracy.Various applications are in the field of automobile,medical industries,aerospace etc....WEDM is used in machining conductive materials where it is required to obtained complicated and intricate shapes with high accuracy.Various applications are in the field of automobile,medical industries,aerospace etc.WEDM is an economical machining option with short product development cycle.Surface roughness,kerf width,Material removal rate,Recast layer hardness and surface microhardness in WEDM are most important responses.In this paper,effect of varied Wire tension on SR,KW,MRR,RCL hardness and surface microhardness on AISI 304 have been investigated.Pulse on time,pulse off time,current and dielectric fluid are taken as fixed parameter.Results show that Wire tension influences the SR,MRR and Surface microhardness and has no effect on kerf width in case of Stainless steel304.展开更多
In a multi-wire proportional chamber detector(MWPC), the anode and signal wires must maintain suitable tension, which is very important for the detector's stable and accurate performance. As a result, wire tension ...In a multi-wire proportional chamber detector(MWPC), the anode and signal wires must maintain suitable tension, which is very important for the detector's stable and accurate performance. As a result, wire tension control and measurement is essential in MWPC construction. A high pressure3 He MWPC detector is to be used as the thermal neutron detector of the multi-functional reflectometer at China Spallation Neutron Source, and in the construction of the detector, we have developed a wire tension measurement system. This system is accurate,portable and time-saving. With it, the wire tension on an anode wire plane has been tested. The measurement results show that the wire tension control techniques used in detector manufacture are reliable.展开更多
Amongst the many known techniques used for the management of fractures of the patella, the tension band wire fixation is a reliable treatment modality and has given consistently good results. In transverse patellar fr...Amongst the many known techniques used for the management of fractures of the patella, the tension band wire fixation is a reliable treatment modality and has given consistently good results. In transverse patellar fractures, a combination of cerclage wiring and tension band fixation gives a good mechanical stability and an environment conducive to healing. The fracture described herein is classified as 45-C1 (based on Orthopaedic Trauma Association classification) of the right knee of a forty three years old male patient. It was fixed with three vertical 1.5 mm K wires and double cerclage wire looped proximally through the quadriceps tendon and distally through the patellar ligament in a double figure-of-eight configuration. The average follow-up period was 7 months. The Activity of Daily Living Scale (ADLS) of the Knee Outcome Survey was used to assess symptoms and functional capability of the knee. The fracture union was achieved at an average of 10 weeks. Full range of knee motion was achieved by end of the third postoperative month. No complications, such as infection and implant failure were noted. The technique aims to stress the advantage of giving a balanced fixation addressing the bony elements (the fractured ends) as well as the soft tissue (the extensor apparatus).展开更多
This paper puts forward a new method to achieve flux cored wire TIG welding and uses high-speed photography to analyze the droplet transfer behavior and forces acting on the droplet. The droplet transfer forms include...This paper puts forward a new method to achieve flux cored wire TIG welding and uses high-speed photography to analyze the droplet transfer behavior and forces acting on the droplet. The droplet transfer forms include bridging transfer, slag column guided transfer, and non-contact transfer; each of these forms may be observed as the melting position of the welding wire changes. The important role of surface tension in the process of droplet transfer is proposed using static force balance theory and pinch instability theory. The phenomenon of droplet backward swing during welding process could be attributed to the vapor recoil force produced by vapors from the droplet. The welding experiments show that the proposed welding process is stable and that the weld quality produced is good.展开更多
Precisely predicting the fatigue life of taut-wire mooring systems has become an interesting and important problem for scientists and engineers since there are still difficulties in the inspection and maintenance of m...Precisely predicting the fatigue life of taut-wire mooring systems has become an interesting and important problem for scientists and engineers since there are still difficulties in the inspection and maintenance of mooring lines in a rough sea environment especially in deep waters. In this paper, a comprehensive fatigue analysis is performed for a polyester taut-wire mooring system of an FPSO based on the time domain dynamic theory, rainflow cycle counting method and linear damage accumulation rule of Palmgren-Miner. Three influential factors in the fatigue analysis including the pre-tension, dynamic stiffness and T-N curve are investigated in detail. Two polyester T-N curves, one is from the DNV- 0S-E301 and the other is from the API-RP-2SM, are adopted in the calculation. The fatigue analysis of the mooting system after one-line failure is also carried out. The calculation results indicate that the fatigue life is significantly affected by the T-N curve. The fatigue life decreases with increasing pre-tension, and is largely reduced if taking into account the dynamic stiffness caused by cyclic loading. The analysis also proves that one-line failure has remarkable effects on the fatigue lives of other mooting lines. The present parametric and comparative study is believed to be meaningful to further understanding of the taut-wire mooting system for deepwater applications.展开更多
文摘This meta-analysis compared the therapeutic effect of cable pin system(CPS) with K-wire tension band(KTB) in the treatment of patella fractures among Chinese Han population. The databases of PubM ed, Cochrane library, China National Knowledge Infrastructure(CNKI), Chinese Wan Fang and Chinese VIP were searched for studies on CPS versus KTB in the treatment of patella fractures among Chinese Han population. Literatures were screened according to the inclusion and exclusion criteria. The quality of the studies was assessed, and meta-analysis was performed using the Cochrane Collaboration's REVMAN 5.3 software. A total of 932 patients from 15 studies were included in this meta-analysis(426 fractures treated with CPS and 506 fractures treated with KTB). There were significant differences in duration of hospital stay [mean difference(MD)=–1.07; 95% confidence interval(CI): –1.71 to –0.43], fracture healing time(MD=–1.23; 95% CI: –1.68 to –0.77), flexion degree of knee joint at 6 th month after operation(MD=14.82; 95% CI: 10.93 to 18.71), incidence of postoperative complication [risk ratio(RR)=0.16; 95% CI: 0.09 to 0.27] and excellent-good rate of B?stman score(RR=1.09; 95% CI: 1.03 to 1.16) between the CPS group and KTB group, while no significant difference was found in operative time between the two groups(MD=–4.52; 95% CI: –11.70 to 2.67). For the treatment of patella fractures among Chinese Han population, limited evidence suggests that the CPS is more suitable than the KTB when considering the hospital stay, fracture healing time, flexion degree of knee at 6 th month after operation, incidence of postoperative complication and excellent-good rate of B?stman joint score. Due to the limitation of high quality evidence and sample size, more large-scale randomized controlled trials are needed to validate the findings in the future.
基金supported by the National Natural Science Fundproject (50775207)Key Laboratory of E & M (Zhejiang University of Technology) Open Fund project (2009EP017)
文摘Based on the analysis of the mechanism of wire tension control by using torque motors in the multi-wire saw machining process, some mathematical models of a tension control system are studied, and an adaptive algo- rithm is designed for controlling the wire tension. In this algorithm of tension control, the rotation speeds and waving angle of motors are measured and fed back to the controller, and the NLMS( normalized least mean squares) algorithm is used to calculate the adaptive correction value and control the wire tension accurately. The computer simulation results in Matlab software validate the high accuracy for controlling the system of the wire tension with the NLMS algorithm in the multi-wire saw machining process.
文摘WEDM is used in machining conductive materials where it is required to obtained complicated and intricate shapes with high accuracy.Various applications are in the field of automobile,medical industries,aerospace etc.WEDM is an economical machining option with short product development cycle.Surface roughness,kerf width,Material removal rate,Recast layer hardness and surface microhardness in WEDM are most important responses.In this paper,effect of varied Wire tension on SR,KW,MRR,RCL hardness and surface microhardness on AISI 304 have been investigated.Pulse on time,pulse off time,current and dielectric fluid are taken as fixed parameter.Results show that Wire tension influences the SR,MRR and Surface microhardness and has no effect on kerf width in case of Stainless steel304.
基金Supported by National Natural Science Foundation of China(A050506)State Key Laboratory of Particle Detection and ElectronicsKey Laboratory of China Academy of Engineering Physics(Y490KF40HD)
文摘In a multi-wire proportional chamber detector(MWPC), the anode and signal wires must maintain suitable tension, which is very important for the detector's stable and accurate performance. As a result, wire tension control and measurement is essential in MWPC construction. A high pressure3 He MWPC detector is to be used as the thermal neutron detector of the multi-functional reflectometer at China Spallation Neutron Source, and in the construction of the detector, we have developed a wire tension measurement system. This system is accurate,portable and time-saving. With it, the wire tension on an anode wire plane has been tested. The measurement results show that the wire tension control techniques used in detector manufacture are reliable.
文摘Amongst the many known techniques used for the management of fractures of the patella, the tension band wire fixation is a reliable treatment modality and has given consistently good results. In transverse patellar fractures, a combination of cerclage wiring and tension band fixation gives a good mechanical stability and an environment conducive to healing. The fracture described herein is classified as 45-C1 (based on Orthopaedic Trauma Association classification) of the right knee of a forty three years old male patient. It was fixed with three vertical 1.5 mm K wires and double cerclage wire looped proximally through the quadriceps tendon and distally through the patellar ligament in a double figure-of-eight configuration. The average follow-up period was 7 months. The Activity of Daily Living Scale (ADLS) of the Knee Outcome Survey was used to assess symptoms and functional capability of the knee. The fracture union was achieved at an average of 10 weeks. Full range of knee motion was achieved by end of the third postoperative month. No complications, such as infection and implant failure were noted. The technique aims to stress the advantage of giving a balanced fixation addressing the bony elements (the fractured ends) as well as the soft tissue (the extensor apparatus).
基金supported by the National Natural Science Foundation of China(No.51175374)the Natural Science Foundation of Tianjin(No.16JCZDJC38700)
文摘This paper puts forward a new method to achieve flux cored wire TIG welding and uses high-speed photography to analyze the droplet transfer behavior and forces acting on the droplet. The droplet transfer forms include bridging transfer, slag column guided transfer, and non-contact transfer; each of these forms may be observed as the melting position of the welding wire changes. The important role of surface tension in the process of droplet transfer is proposed using static force balance theory and pinch instability theory. The phenomenon of droplet backward swing during welding process could be attributed to the vapor recoil force produced by vapors from the droplet. The welding experiments show that the proposed welding process is stable and that the weld quality produced is good.
基金supported by the Key Project of the National Natural Science Foundation of China (Grant No. 50639030)the National High Technology Research and Development Program of China (863 Program, Grant No. 2006AA09Z348)
文摘Precisely predicting the fatigue life of taut-wire mooring systems has become an interesting and important problem for scientists and engineers since there are still difficulties in the inspection and maintenance of mooring lines in a rough sea environment especially in deep waters. In this paper, a comprehensive fatigue analysis is performed for a polyester taut-wire mooring system of an FPSO based on the time domain dynamic theory, rainflow cycle counting method and linear damage accumulation rule of Palmgren-Miner. Three influential factors in the fatigue analysis including the pre-tension, dynamic stiffness and T-N curve are investigated in detail. Two polyester T-N curves, one is from the DNV- 0S-E301 and the other is from the API-RP-2SM, are adopted in the calculation. The fatigue analysis of the mooting system after one-line failure is also carried out. The calculation results indicate that the fatigue life is significantly affected by the T-N curve. The fatigue life decreases with increasing pre-tension, and is largely reduced if taking into account the dynamic stiffness caused by cyclic loading. The analysis also proves that one-line failure has remarkable effects on the fatigue lives of other mooting lines. The present parametric and comparative study is believed to be meaningful to further understanding of the taut-wire mooting system for deepwater applications.