期刊文献+
共找到47篇文章
< 1 2 3 >
每页显示 20 50 100
A 2.4GHz Low Power ASK Transmitter for Wireless Capsule Endoscope Applications
1
作者 韩书光 池保勇 王志华 《Journal of Semiconductors》 EI CAS CSCD 北大核心 2006年第6期988-993,共6页
A 2.4GHz ASK transmitter suitable for a low power wireless capsule endoscope system is presented. A mixer-based frequency up-conversion transmitter architecture is employed to achieve a high data rate. A pseudodiffere... A 2.4GHz ASK transmitter suitable for a low power wireless capsule endoscope system is presented. A mixer-based frequency up-conversion transmitter architecture is employed to achieve a high data rate. A pseudodifferential stacked class-A power amplifier using the current reuse technique is proposed to save power. The transmitter mainly includes two parts: a 20MHz ASK modulator based on a constant amplitude phase lock loop (PLL) and a direct up-conversion RF circuit. This design, implemented in a TSMC 0.25μm CMOS process, achieves a - 23. 217dBm output power with a data rate of 1Mbps and dissipates 3.17mA of current with a single 2.5V power supply. 展开更多
关键词 wireless capsule endoscope amplitude shift keying PLL TRANSMITTER CMOS
下载PDF
RF characteristics of wireless capsule endoscopy in human body 被引量:4
2
作者 王璟琛 王炤 +3 位作者 Mark Leach LEE Sanghyuk Eng Gee Lim HUANG Yi 《Journal of Central South University》 SCIE EI CAS CSCD 2016年第5期1198-1207,共10页
The wireless capsule endoscope,as a small electronic device,has conquered some limitations of traditional wired diagnosing tools,such as the uncomfortableness of the cables for the patient and the inability to examine... The wireless capsule endoscope,as a small electronic device,has conquered some limitations of traditional wired diagnosing tools,such as the uncomfortableness of the cables for the patient and the inability to examine the very convoluted small intestine section.However,this technique is still encountering a lot of practical challenges and is looking for feasible improvements.This work investigates the RF performance of the wireless capsule endoscope system by studying the electromagnetic(EM) wave propagation within the human body.A wireless capsule endoscopy transmission channel model is constructed to serve the purpose of investigating signal attenuations according to the relative position between the transmitter and the receiver.Within 300-500 MHz,the S_(21) results are regular and do not display any sudden changes,which allows a suitable expression to be derived for S_(21) in terms of frequency and offset.The results provide useful information for capsule localization. 展开更多
关键词 wireless capsule endoscopy wce electromagnetic wave propagation signal attenuations POSITIONING transmission channel
下载PDF
Bleeding and Ulcer Detection Using Wireless Capsule Endoscopy Images 被引量:2
3
作者 Jinn-Yi Yeh Tai-Hsi Wu Wei-Jun Tsai 《Journal of Software Engineering and Applications》 2014年第5期422-432,共11页
Wireless capsule endoscopes (WCEs) have been used widely to detect abnormalities inside regions of the small intestine that are not accessible when using traditional endoscopy techniques. However, an experienced clini... Wireless capsule endoscopes (WCEs) have been used widely to detect abnormalities inside regions of the small intestine that are not accessible when using traditional endoscopy techniques. However, an experienced clinician must spend an average of 2 hours to view and analyze the approximately 60,000 images produced during one examination. Therefore, developing a computeraided system for processing WCE images is crucial. This paper proposes a novel method used for detecting bleeding and ulcers in WCE images. This approach involves using color features to determine the status of the small intestine. The experimental results revealed that the proposed scheme is promising in detecting bleeding and ulcer regions. 展开更多
关键词 wireless capsule endoscope (wce) COMPUTER-AIDED Diagnosis BLEEDING ULCER
下载PDF
Meckel's diverticulum diagnosis by video capsule endoscopy: A case report and review of literature
4
作者 Diego García-Compeán Alan R Jiménez-Rodríguez +3 位作者 Angel N Del Cueto-Aguilera Gilberto Herrera-Quinones José A González-González Héctor J Maldonado-Garza 《World Journal of Clinical Cases》 SCIE 2018年第14期791-799,共9页
BACKGROUND Meckel’s diverticulum (MD) occurs predominantly in chil-dren and adolescents. It is rarely diagnosed in adults. Preoperative diagnosis is diffcult due to low sensitivity of the radiological imaging studi... BACKGROUND Meckel’s diverticulum (MD) occurs predominantly in chil-dren and adolescents. It is rarely diagnosed in adults. Preoperative diagnosis is diffcult due to low sensitivity of the radiological imaging studies. The role of video capsule endoscopy (VCE) in the diagnosis of MD is unknown, and the endoscopic patterns are not defned. We will describe four of our cases of MD evaluated with VCE and make a review of the literature focusing on the endoscopic characteristics.CASE SUMMARYWe present four cases of MD confirmed by surgery. They were all adult males with ages going from 18 to 50 years, referred to our service from 2004 to 2018, due to obscure gastrointestinal bleeding (OGIB). TheyGarcía-Compeán D et al . Merckel’s diverticulum diagnosis by VCEhad a history of 1 mo to 10 years of overt and occult bleeding episodes. Laboratory blood test showed an iron-deficiency anemia from 4 to 9 g/dL of hemoglo-bin that required multiple hospitalizations and blood transfusions in all cases. Repeated upper digestive endoscopies and colonoscopies were negative. Small bowel was examined with VCE, which revealed double lumen images in all cases, one with polyps and three with circumferential ulcers in the diverticulum. However, based on VCE findings, preoperative diagnosis of MD was suggested only in two patients. Capsule was retain-ed in one patient, which was recovered with surgery. The anatomopathological report revealed ulcerated ectopic gastric mucosa in all cases.CONCLUSIONVCE is useful for the diagnosis of MD. However, endo-scopic characteristics must be recognized in order to establish preoperative diagnosis. 展开更多
关键词 Meckel’s diverticulum Endoscopic features Video capsule endoscopy wireless capsule endoscopy REVIEW Case report
下载PDF
Smart Image Sensor with Integrated Low Complexity Image Processing for Wireless Endoscope Capsules 被引量:1
5
作者 李晓雯 张沕琳 +1 位作者 王志华 Amine Bermak 《Tsinghua Science and Technology》 SCIE EI CAS 2009年第5期586-592,共7页
A smart image sensor was developed which integrates a digital pixel image sensor array with an image processor, designed for wireless endoscope capsules. The camera-on-a-chip architecture and its on-chip functionality... A smart image sensor was developed which integrates a digital pixel image sensor array with an image processor, designed for wireless endoscope capsules. The camera-on-a-chip architecture and its on-chip functionality facilitate the design of the packaging and power consumption of the integrated capsule. The power reduction techniques were carried out at both the architectural and circuit level. Gray coding and power gating in the sensor array to eliminate almost 50% of the switch activity on the data bus and more than 99% of the power dissipation in each pixel at a transmitting rate of 2 frames per second. Filtering and compression in the processor reduces the data transmission by more than 2/3. A parallel fully pipelined architecture with a dedicated clock management scheme was implemented in the JPEG-LS engine to reduce the power consumption by 15.7%. The smart sensor has been implemented in 0.18 μm CMOS technology. 展开更多
关键词 wireless endoscope capsule digital pixel sensor JPEG-LS low power
原文传递
基于OV2640的微型胶囊内窥镜系统设计 被引量:17
6
作者 程磊 刘波 +2 位作者 徐建省 吴怀宇 陈洋 《传感器与微系统》 CSCD 北大核心 2014年第2期73-76,79,共5页
为了实现消化道疾病的无痛检查,研究并设计了一种基于OV2640的微型胶囊内窥镜无线图像传输系统,该系统由2.4GHz低功耗射频收发芯片nRF24LE1和CMOS图像传感器OV2640构成。分析了图像无线传输的原理与图像压缩技术,介绍了该系统的硬件结... 为了实现消化道疾病的无痛检查,研究并设计了一种基于OV2640的微型胶囊内窥镜无线图像传输系统,该系统由2.4GHz低功耗射频收发芯片nRF24LE1和CMOS图像传感器OV2640构成。分析了图像无线传输的原理与图像压缩技术,介绍了该系统的硬件结构。实验结果表明:该系统可得到清晰的图像,系统运行稳定,功耗低,体内微型胶囊内窥镜直径只有13 mm,为微型胶囊内窥镜的临床诊断提供了一种可行方案。 展开更多
关键词 无线胶囊内窥镜 JPEG压缩 OV2640图像传感器 NRF24LE1
下载PDF
胶囊内窥镜能量接收稳定性研究 被引量:14
7
作者 辛文辉 颜国正 +1 位作者 王文兴 贾智伟 《仪器仪表学报》 EI CAS CSCD 北大核心 2009年第11期2433-2437,共5页
提出了用三维接收线圈组成接收电路,解决由于无线胶囊内窥镜在人体消化道内姿态不确定所带来的接收能量不稳定问题。分析了由三维接收线圈组成的不同接收电路的接收效果,得出了对每一维线圈单独全桥整流后再并联输出的电路结构是最适合... 提出了用三维接收线圈组成接收电路,解决由于无线胶囊内窥镜在人体消化道内姿态不确定所带来的接收能量不稳定问题。分析了由三维接收线圈组成的不同接收电路的接收效果,得出了对每一维线圈单独全桥整流后再并联输出的电路结构是最适合于为胶囊内窥镜供能的电路。计算了该接收电路的输出范围,并通过试验对其进行了验证。结果表明:当发射功率为25W时,胶囊内窥镜可在姿态任意变化的情况下获得320mW以上可用能量,满足其高清晰度、高帧率功能对能量的需求。 展开更多
关键词 胶囊内窥镜 感应耦合 三维接收线圈
下载PDF
消化道药丸式微型诊疗系统研究进展 被引量:8
8
作者 皮喜田 彭承琳 +4 位作者 郑小林 侯文生 樊华 崔建国 刘洪英 《中国医疗器械杂志》 CAS 2004年第2期120-124,共5页
介绍国内外无线内窥镜、药丸式消化道监测系统、药丸式药物遥控释放系统、药丸式消化道采样系统、药丸式消化道治疗系统等微型诊疗系统的研究进展并对技术现状及发展趋势进行了分析。
关键词 消化道药丸式微型诊疗系统 研究进展 无线内窥镜 系统结构 遥控技术
下载PDF
药丸式微型诊疗仪器研究进展 被引量:10
9
作者 皮喜田 彭承琳 +5 位作者 郑小林 唐伟 候文生 樊华 崔建国 张思杰 《医疗卫生装备》 CAS 2004年第3期29-32,共4页
药丸式微型诊疗仪器是微创医疗研究热点。以临床应用分类分别对无线内窥镜、药丸式消化道监测系统、药丸式药物控制释放系统、药丸式消化道采样系统、药丸式消化道治疗系统等系统的研究进展进行详细介绍,对国内研究现状及技术发展趋势... 药丸式微型诊疗仪器是微创医疗研究热点。以临床应用分类分别对无线内窥镜、药丸式消化道监测系统、药丸式药物控制释放系统、药丸式消化道采样系统、药丸式消化道治疗系统等系统的研究进展进行详细介绍,对国内研究现状及技术发展趋势进行了分析。 展开更多
关键词 药丸式微型诊疗食品 药丸式微型诊疗仪器 消化道 MEMS 机器人 智能药丸 无线内窥镜
下载PDF
基于JPEG图像的无线胶囊内窥镜的设计 被引量:7
10
作者 潘国兵 颜国正 邱祥玲 《高技术通讯》 EI CAS CSCD 北大核心 2010年第1期89-93,共5页
为了检测胃肠(GI)道疾病,设计并研制了一种新型的基于JPEG格式的数字式无线胶囊内窥镜(WCE)系统。胶囊内窥镜的直径为12mm,长28mm,非常易于吞服。胶囊内窥镜在人体肠道的蠕动作用下顺着消化道向下运动,同时获得分辨率为320×240的... 为了检测胃肠(GI)道疾病,设计并研制了一种新型的基于JPEG格式的数字式无线胶囊内窥镜(WCE)系统。胶囊内窥镜的直径为12mm,长28mm,非常易于吞服。胶囊内窥镜在人体肠道的蠕动作用下顺着消化道向下运动,同时获得分辨率为320×240的内窥镜图像,图像被压缩为JPEG格式后直接采用数字信号无线传出体外,无需进行D/A转换。数据被体外的接收盒接收存储,然后由图像分析软件进行再现、分析、诊断等处理。在用猪小肠模拟人体肠道的离体实验中,该胶囊内窥镜系统清晰地再现了猪小肠内部的图像。与基于Bayer格式模拟信号的胶囊内窥镜相比,数字信号抗干扰能力强,图像更加清晰,将有助于提高临床胃肠道疾病的诊断率。 展开更多
关键词 无线胶囊内窥镜(wce) 数字无线通信 JPEG图像 胃肠(GI)道疾病
下载PDF
胶囊内窥镜冗余图像数据自动筛除方法 被引量:7
11
作者 孙宇千 吕庆文 +1 位作者 刘哲星 刘思德 《计算机应用研究》 CSCD 北大核心 2012年第6期2393-2396,2400,共5页
针对胶囊内窥镜检查的海量图像数据,提出基于归一化互信息量及归一化互相关系数的冗余图像数据筛除方法。将图像在HSV色彩空间量化聚类;然后计算相邻图像的相似度系数,最后根据相似筛除比例进行迭代筛除。针对49例病例,按照70%的筛除比... 针对胶囊内窥镜检查的海量图像数据,提出基于归一化互信息量及归一化互相关系数的冗余图像数据筛除方法。将图像在HSV色彩空间量化聚类;然后计算相邻图像的相似度系数,最后根据相似筛除比例进行迭代筛除。针对49例病例,按照70%的筛除比率,实验结果得到100%的病灶数量保留率和较低的图像误删率。基于归一化互信息量冗余图像数据筛除方法能够高效准确地筛除冗余图像数据并极大地缩短阅片时间;在该算法的基础上,开发了胶囊内窥镜图像自动筛查系统,为医生判诊提供辅助和支持。 展开更多
关键词 胶囊内窥镜 归一化互信息量 归一化互相关系数 病灶数量保留率 图像误删率
下载PDF
视频胶囊内窥镜无线能量接收系统的设计 被引量:8
12
作者 石煜 颜国正 朱柄全 《仪器仪表学报》 EI CAS CSCD 北大核心 2014年第3期703-708,共6页
基于电磁感应的无线能量传输系统可取代纽扣电池,为视频胶囊内窥镜提供充足稳定的能量,以延长其工作时间,同时提高图像质量。在限定接收线圈体积的条件下,通过对比,得到相对磁导率最大的磁芯形状与尺寸;对绕线采用不同的股数与匝数搭配... 基于电磁感应的无线能量传输系统可取代纽扣电池,为视频胶囊内窥镜提供充足稳定的能量,以延长其工作时间,同时提高图像质量。在限定接收线圈体积的条件下,通过对比,得到相对磁导率最大的磁芯形状与尺寸;对绕线采用不同的股数与匝数搭配,确定品质因数最高的接收线圈模型;最后将接收电路模块化,节省空间的同时提高了接收能量转化效率。集成了接收线圈的视频胶囊在无线供能平台上以30帧/秒的速率向外发送分辨率为320×240的图像,功率为78.4 mW。实验结果证明了此方法的可行性。 展开更多
关键词 无线能量传输 视频胶囊内窥镜 品质因数 谐振电路
下载PDF
胶囊内窥镜无线供能模块的研制 被引量:3
13
作者 辛文辉 颜国正 王文兴 《上海交通大学学报》 EI CAS CSCD 北大核心 2010年第8期1109-1113,共5页
为了解决无线胶囊内窥镜电池供电不足的问题,研制了一种供能模块,在体外通过电磁感应方式为体内的胶囊内窥镜进行无线供能.针对胶囊内窥镜在人体内姿态的不确定以及微型化的特点和要求,设计、制作了合适的能量发射和接收装置,并通过实... 为了解决无线胶囊内窥镜电池供电不足的问题,研制了一种供能模块,在体外通过电磁感应方式为体内的胶囊内窥镜进行无线供能.针对胶囊内窥镜在人体内姿态的不确定以及微型化的特点和要求,设计、制作了合适的能量发射和接收装置,并通过实验对能量传输效果进行了验证.结果表明:当发射功率为18 W、在胶囊内窥镜姿态任意变化的情况下,无线供能模块能提供至少150mW的能量,且接收装置的空间尺寸仅φ10 mm×11 mm.在此基础上,研制出的胶囊内窥镜样机在离体实验中得到了清晰的猪小肠图像. 展开更多
关键词 无线胶囊内窥镜 无线能量传输 电磁感应 三维接收线圈
下载PDF
胃肠道无线内窥镜中可吞服摄像药丸的研究 被引量:2
14
作者 张思杰 彭承琳 +3 位作者 郑小林 刘艳 皮喜田 侯文生 《中国医疗器械杂志》 CAS 2005年第5期328-330,共3页
介绍无线摄像药丸直径11mm,长30mm,包括CMOS图像传感器、光学系统、电池、发射电路及天线等。利用MEMS工艺将CMOS图像传感器和驱动电路微型化,也可将发射电路集成化。图像信号有模拟和数字两种传输方式。数字方式使用串行数据接口传输... 介绍无线摄像药丸直径11mm,长30mm,包括CMOS图像传感器、光学系统、电池、发射电路及天线等。利用MEMS工艺将CMOS图像传感器和驱动电路微型化,也可将发射电路集成化。图像信号有模拟和数字两种传输方式。数字方式使用串行数据接口传输图像。最后介绍药丸外壳的加工工艺。 展开更多
关键词 可吞服摄像药丸 无线内窥镜 MEMS技术
下载PDF
胶囊内窥图像出血检测中颜色向量相似系数分类器的设计 被引量:1
15
作者 潘国兵 颜国正 +1 位作者 宋昕帅 邱祥玲 《上海交通大学学报》 EI CAS CSCD 北大核心 2009年第11期1715-1719,共5页
为了提高胶囊内窥图像出血智能识别的识别率,将颜色表示与向量运算相结合,提出了使用颜色向量相似系数度量颜色相似性的新方法,推导了颜色向量相似性系数的定义式.在此基础上,设计了应用于RGB颜色空间的颜色向量相似系数分类器,并结合... 为了提高胶囊内窥图像出血智能识别的识别率,将颜色表示与向量运算相结合,提出了使用颜色向量相似系数度量颜色相似性的新方法,推导了颜色向量相似性系数的定义式.在此基础上,设计了应用于RGB颜色空间的颜色向量相似系数分类器,并结合种子区域生长算法实现了内窥图像出血智能识别的新算法.通过实验验证,该算法的出血检测灵敏度和特异度分别达97%和90%,基本实现了胶囊内窥图像出血智能识别. 展开更多
关键词 胶囊内窥镜 颜色向量相似系数 出血检测 模式识别
下载PDF
基于CF卡的无线胶囊内窥镜体外接收存储系统 被引量:1
16
作者 王富民 颜国正 王文兴 《电子测量技术》 2008年第7期103-107,共5页
本文介绍了一种基于CF卡的无线胶囊内窥镜体外接收存储系统的结构与原理。该系统采用高速单片机对接收的图像帧进行同步,采用FIFO对接收到的高速图像数据进行缓存,并在FPGA和单片机的共同控制下于胶囊休眠期将数据写入数据卡,成功实现... 本文介绍了一种基于CF卡的无线胶囊内窥镜体外接收存储系统的结构与原理。该系统采用高速单片机对接收的图像帧进行同步,采用FIFO对接收到的高速图像数据进行缓存,并在FPGA和单片机的共同控制下于胶囊休眠期将数据写入数据卡,成功实现了实时记录长时间图像数据的功能,提高了系统的可靠性。 展开更多
关键词 CF卡 无线胶囊内窥镜 FPGA FIFO FAT32
下载PDF
人体消化道无线内窥镜EMC模型设计方案 被引量:2
17
作者 周平 彭承琳 金鑫 《中国医疗设备》 2009年第3期44-46,共3页
人体消化道医用无线内窥镜系统现正处于研制阶段,本文通过对该系统各部分结构的分析,在标准YY0505-2005的基础上,结合国家对移动通讯设备相关标准的要求,根据其特点构建了人体消化道医用无线内窥镜电磁兼容性试验模型,进而编制了其电磁... 人体消化道医用无线内窥镜系统现正处于研制阶段,本文通过对该系统各部分结构的分析,在标准YY0505-2005的基础上,结合国家对移动通讯设备相关标准的要求,根据其特点构建了人体消化道医用无线内窥镜电磁兼容性试验模型,进而编制了其电磁兼容性的标准化试验方法及性能判据。 展开更多
关键词 电磁兼容性 标准化试验 试验模型 无线内窥镜系统
下载PDF
人体胶囊式无线内窥微机电系统的设计与工作寿命研究 被引量:2
18
作者 陈英俊 黄平 《机械设计与制造》 北大核心 2009年第9期40-42,共3页
在设计人体胶囊式无线内窥微机电系统过程中,通过理论分析和实验测试,研究了影响系统工作寿命的图像传感器选用、无线发射电路配置、控制方式选择,以及电源系统的设计问题。选用了CMOS图像传感器,精确合理地配置了无线发射功率,设计了... 在设计人体胶囊式无线内窥微机电系统过程中,通过理论分析和实验测试,研究了影响系统工作寿命的图像传感器选用、无线发射电路配置、控制方式选择,以及电源系统的设计问题。选用了CMOS图像传感器,精确合理地配置了无线发射功率,设计了灵活省电的永磁场控制方式,选择了锂锰钮扣电池和其电池组构成电源系统,研制出了微体积、易于控制、有较好图像质量、较长工作寿命的人体胶囊式无线内窥微机电系统,给出的由该系统在实验室条件下和动物实验中采集的图像及测试参数表明设计方案是可行的。 展开更多
关键词 胶囊式无线内窥 微机电系统 图像传感器 无线发射 磁场控制 工作寿命 电源系统
下载PDF
磁控人体胶囊式无线内窥微机电系统的结构设计与实验研究 被引量:2
19
作者 陈英俊 黄平 《机械设计》 CSCD 北大核心 2008年第3期53-56,共4页
通过理论分析和实验研究,详细讨论了磁控人体胶囊式无线内窥微机电系统设计中的结构设计问题。首先根据无线内窥镜的使用环境和微型化要求,设计了合理的镜头,依照图像传感器采样照度确定了照明装置,选用了无线磁控式的控制方式实现系统... 通过理论分析和实验研究,详细讨论了磁控人体胶囊式无线内窥微机电系统设计中的结构设计问题。首先根据无线内窥镜的使用环境和微型化要求,设计了合理的镜头,依照图像传感器采样照度确定了照明装置,选用了无线磁控式的控制方式实现系统的定点工作。然后对研制出来的内窥镜样机进行了离体和活体动物实验,实验中采集到的图像表明,此无线内窥镜的结构设计方案是可行的。 展开更多
关键词 结构设计 胶囊 无线内窥镜 磁控 微机电系统
下载PDF
主动式胶囊内窥镜系统设计 被引量:1
20
作者 辛文辉 侯逢勃 《测控技术》 CSCD 北大核心 2014年第10期13-16,21,共5页
设计了一种新型的、基于无线供能的主动式胶囊内窥镜系统,包括胶囊内镜、主动运动、无线供能3个子系统。胶囊内镜子系统可实时获取、传输肠道内部的图像信息;主动运动子系统将微型电机的旋转运动转化为胶囊内窥镜的径向和轴向伸缩,并按... 设计了一种新型的、基于无线供能的主动式胶囊内窥镜系统,包括胶囊内镜、主动运动、无线供能3个子系统。胶囊内镜子系统可实时获取、传输肠道内部的图像信息;主动运动子系统将微型电机的旋转运动转化为胶囊内窥镜的径向和轴向伸缩,并按照一定的时序配合实现仿尺蠖运动;无线供能子系统接收体外发射线圈产生的电磁场能,将其转换成电能,为整个系统提供能源。后续实验表明:主动式胶囊内窥镜可以运动、定位到肠道病灶点,进行主动式图像诊察,可克服已有胶囊内窥镜不能主动运动,仅靠胃肠蠕动来推动而造成的漏检、误检等缺陷。 展开更多
关键词 胶囊内窥镜 无线能量传输 主动运动 离体实验
下载PDF
上一页 1 2 3 下一页 到第
使用帮助 返回顶部