The safety of lithium-ion batteries is an essential concern where instant and accurate temperature sensing is critical.It is generally desired to put sensors inside batteries for instant sensing.However,the transmissi...The safety of lithium-ion batteries is an essential concern where instant and accurate temperature sensing is critical.It is generally desired to put sensors inside batteries for instant sensing.However,the transmission of internal measurement outside batteries without interfering their normal state is a non-trivial task due to the harsh electrochemical environment,the particular packaging structures and the intrinsic electromagnetic shielding problems of batteries.In this work,a novel in-situ temperature sensing framework is proposed by incorporating temperature sensors with a novel signal transmission solution.The signal transmission solution uses a self-designed integrated-circuit which modulates the internal measurements outside battery via its positive pole without package breaking.Extensive experimental results validate the noninterference properties of the proposed framework.Our proposed in-situ temperature measurement by the self-designed signal modulation solution has a promising potential for in-situ battery health monitoring and thus promoting the development of smart batteries.展开更多
based on optimal design on the core element of the sensor,a wireless and passive surface acoustic wave(SAW)temperature sensor integrated with ID Tag was presented.A reflective delay line,which consists of a transduc...based on optimal design on the core element of the sensor,a wireless and passive surface acoustic wave(SAW)temperature sensor integrated with ID Tag was presented.A reflective delay line,which consists of a transducer and eight reflectors on YZ LiNbO3 substrate.Was fabricated as the sensor element,in which,three reflectors were used for temperature sensing,and the other five were for the ID Tag using phase encoding.Single phase unidirectional transducers(SPUDTs)and shorted grating were used to structure the sAW device,leading to excellent signal to noise ratio(SNR).The performance of the SAW device was simulated by the coupling of modes(COM)prior to fabrication.Using the network analyzer,the response in time domain of the fabricated 434 MHz SAW sensor was characterized,the measured S11 agrees well with the simulated one,sharp reflection peaks,high signal/noise,and low spurious noise between the reflection peaks were observed.Using the radar system based on FSCW as the reader unit.the developed SAW temperature sensors were evaluated wirelessly.Excellent1 inearity and good resolution of士1℃ were observed.展开更多
In this study, finite element analysis based on an Ansoft Maxwell software was used to reveal the temperature stability of a magnet ring and the equivalent structural periodic permanent-magnet(PPM) focusing system. ...In this study, finite element analysis based on an Ansoft Maxwell software was used to reveal the temperature stability of a magnet ring and the equivalent structural periodic permanent-magnet(PPM) focusing system. It is found that with the temperature increasing, the decrease rate of magnetic induction peak(Bz)maxof single magnet ring is greater than that of remanence Brof magnet in the range from room temperature to 200 °C, however,the PPM focusing system do have the same temperature characteristics of permanent-magnet materials. It indicates that the magnetic temperature properties of the PPM system can be effectively controlled by adjusting the temperature properties of the magnets. Moreover, the higher permeability of the magnets indicates the less Hcb, giving rise to lower magnetic induction peak (Bz)′max: Finally, it should be noted that the magnetic orientation deviation angle θ(/15°) of permanent magnets has little effect on the focusing magnetic field of the PPM system at different temperatures and the temperature stability. The obtained results are beneficial to the design and selection of permanent magnets for PPM focusing system.展开更多
基金This work was supported by the Beijing Municipal Science and Technology Commission(Grant Z191100002719007)the National Natural Science Foundation of China(Grant 11672341).
文摘The safety of lithium-ion batteries is an essential concern where instant and accurate temperature sensing is critical.It is generally desired to put sensors inside batteries for instant sensing.However,the transmission of internal measurement outside batteries without interfering their normal state is a non-trivial task due to the harsh electrochemical environment,the particular packaging structures and the intrinsic electromagnetic shielding problems of batteries.In this work,a novel in-situ temperature sensing framework is proposed by incorporating temperature sensors with a novel signal transmission solution.The signal transmission solution uses a self-designed integrated-circuit which modulates the internal measurements outside battery via its positive pole without package breaking.Extensive experimental results validate the noninterference properties of the proposed framework.Our proposed in-situ temperature measurement by the self-designed signal modulation solution has a promising potential for in-situ battery health monitoring and thus promoting the development of smart batteries.
基金supported by the National Nature Science Foundation of China(11074268,10834010)
文摘based on optimal design on the core element of the sensor,a wireless and passive surface acoustic wave(SAW)temperature sensor integrated with ID Tag was presented.A reflective delay line,which consists of a transducer and eight reflectors on YZ LiNbO3 substrate.Was fabricated as the sensor element,in which,three reflectors were used for temperature sensing,and the other five were for the ID Tag using phase encoding.Single phase unidirectional transducers(SPUDTs)and shorted grating were used to structure the sAW device,leading to excellent signal to noise ratio(SNR).The performance of the SAW device was simulated by the coupling of modes(COM)prior to fabrication.Using the network analyzer,the response in time domain of the fabricated 434 MHz SAW sensor was characterized,the measured S11 agrees well with the simulated one,sharp reflection peaks,high signal/noise,and low spurious noise between the reflection peaks were observed.Using the radar system based on FSCW as the reader unit.the developed SAW temperature sensors were evaluated wirelessly.Excellent1 inearity and good resolution of士1℃ were observed.
基金financially supported by the National Natural Science Foundation of China (No. 61001120)
文摘In this study, finite element analysis based on an Ansoft Maxwell software was used to reveal the temperature stability of a magnet ring and the equivalent structural periodic permanent-magnet(PPM) focusing system. It is found that with the temperature increasing, the decrease rate of magnetic induction peak(Bz)maxof single magnet ring is greater than that of remanence Brof magnet in the range from room temperature to 200 °C, however,the PPM focusing system do have the same temperature characteristics of permanent-magnet materials. It indicates that the magnetic temperature properties of the PPM system can be effectively controlled by adjusting the temperature properties of the magnets. Moreover, the higher permeability of the magnets indicates the less Hcb, giving rise to lower magnetic induction peak (Bz)′max: Finally, it should be noted that the magnetic orientation deviation angle θ(/15°) of permanent magnets has little effect on the focusing magnetic field of the PPM system at different temperatures and the temperature stability. The obtained results are beneficial to the design and selection of permanent magnets for PPM focusing system.