期刊文献+
共找到12篇文章
< 1 >
每页显示 20 50 100
Encoderless Five-phase PMa-SynRM Drive System Based on Robust Torque-speed Estimator with Super-twisting Sliding Mode Control
1
作者 Ghada A.Abdel Aziz Rehan Ali Khan 《CES Transactions on Electrical Machines and Systems》 CSCD 2023年第1期54-62,共9页
In this paper,a robust torque speed estimator(RTSE)for linear parameter changing(LPC)system is proposed and designed for an encoderless five-phase permanent magnet assisted synchronous reluctance motor(5-phase PMa-Syn... In this paper,a robust torque speed estimator(RTSE)for linear parameter changing(LPC)system is proposed and designed for an encoderless five-phase permanent magnet assisted synchronous reluctance motor(5-phase PMa-SynRM).This estimator is utilized for estimating the rotor speed and the load torque as well as can solve the speed sensor fault problem,as the feedback speed information is obtained directly from the virtual sensor.In addition,this technique is able to enhance the 5-phase PMa-SynRM performance by estimating the load torque for the real time compensation.The stability analysis of the proposed estimator is performed via Schur complement along with Lyapunov analysis.Furthermore,for improving the 5-phase PMa-SynRM performance,five super-twisting sliding mode controllers(ST-SMCs)are employed with providing a robust response without the impacts of high chattering problem.A super-twisting sliding mode speed controller(ST-SMSC)is employed for controlling the PMa-SynRM rotor speed,and four super-twisting sliding mode current controllers(ST-SMCCs)are employed for controlling the 5-phase PMa-SynRM currents.The stability analysis and the experimental results indicate the effectiveness along with feasibility of the proposed RTSE and the ST-SMSC with ST-SMCCs approach for a 750-W 5-phase PMa-SynRM under load disturbance,parameters variations,single open-phase fault,and adjacent two-phase open circuit fault conditions. 展开更多
关键词 five-phase permanent magnet assisted synchronous reluctance motor Encoderless control Supertwisting sliding mode control Torque-speed estimator
下载PDF
Performance Analysis and Comparison of Two Fault-Tolerant Model Predictive Control Methods for Five-Phase PMSM Drives 被引量:5
2
作者 Wentao Huang Wei Hua Qigao Fan 《CES Transactions on Electrical Machines and Systems》 CSCD 2021年第4期311-320,共10页
Model predictive current control(MPCC)and model predictive torque control(MPTC)are two derivatives of model predictive control.These two control methods have demonstrated their strengths in the fault-tolerant control ... Model predictive current control(MPCC)and model predictive torque control(MPTC)are two derivatives of model predictive control.These two control methods have demonstrated their strengths in the fault-tolerant control of multiphase motor drives.To explore the inherent link,the pros and cons of two strategies,the performance analysis and comparative investigation of MPCC and MPTC are conducted through a five-phase permanent magnet synchronous motor with open-phase fault.In MPCC,the currents of fundamental and harmonic subspaces are simultaneously employed and constrained for a combined regulation of the open-circuit fault drive.In MPTC,apart from the torque and the stator flux related to fundamental subspace,the x-y currents are also considered and predicted to achieve the control of harmonic subspace.The principles of two methods are demonstrated in detail and the link is explored in terms of the cost function.Besides,the performance by two methods is experimentally assessed in terms of steady-state,transition,and dynamic tests.Finally,the advantages and disadvantages of each method are concluded. 展开更多
关键词 Permanent magnet motor five-phase fault-tolerant control model predictive control
下载PDF
Fault-Tolerant Operation of Five-Phase Permanent Magnet Synchronous Motor with Independent Phase Driving Control 被引量:3
3
作者 Yongqing Wei Mingzhong Qiao Peng Zhu 《CES Transactions on Electrical Machines and Systems》 CSCD 2022年第1期105-110,共6页
The multi-phase motor drive system with multiple H-bridge power supply has high fault tolerance,which is widely used in aerospace,electric vehicle,ship integrated power system and other fields.In this paper,a fault-to... The multi-phase motor drive system with multiple H-bridge power supply has high fault tolerance,which is widely used in aerospace,electric vehicle,ship integrated power system and other fields.In this paper,a fault-tolerant control strategy based on decoupling control and stator current compensation is proposed for the propulsion system of five-phase PMSM with independent neutrals.Firstly,the mathematical model of PMSM is established by using vector space decoupling method;Secondly,a stator current compensation method is adopted to carry out fault-tolerant control after the motor has single-phase and two-phase open-circuit faults and the fault-tolerant control system based on decoupling control is established;Finally,the decoupling control model and the fault-tolerant control of stator current compensation are verified by the simulation and experiment.The simulation and experiment results show that the method can reduce the torque ripple caused by the stator winding open-circuit fault,and the operation performance of the motor under fault condition is significantly improved. 展开更多
关键词 five-phase permanent magnet synchronous motor H-bridge inverter Fault-tolerant control Vector space decoupling
下载PDF
Comparative Study on Torque Performance of Five-phase Single-Stator and Double-Stator Permanent Magnet Synchronous Motors
4
作者 Jing Zhao You Wang +1 位作者 Jingqi Li Hengzai Hu 《CES Transactions on Electrical Machines and Systems》 CSCD 2022年第1期46-52,共7页
This paper compares the torque characteristics of single stator permanent magnet synchronous motor(PMSM)and double-stator PMSM under different split-ratios,air-gap lengths and shaft diameters by finite element method.... This paper compares the torque characteristics of single stator permanent magnet synchronous motor(PMSM)and double-stator PMSM under different split-ratios,air-gap lengths and shaft diameters by finite element method.Firstly,the effects of split-ratio towards the torque characteristics of the two motor structures under different air-gap lengths are researched,the results show that the optimal split-ratios of the two motor structures do not change under different air-gap lengths,and the optimal split-ratio of the double-stator motor is greater than that of single-stator,and the torque of the double-stator motor is greater than that of single-stator motor with arbitrary split-ratio under the same air-gap length;Finally,the effects of the shaft diameter to the torque of the two motor structures are investigated,obtaining that with the increasing of shaft diameter,the electromagnetic torque of the single-stator motor is almost unchanged,however,the torque of the double-stator is gradually reduced,when the shaft diameter reached a certain extent,the electromagnetic torque of the double-stator motor is smaller than that of single-stator motor with the split ratio within a certain range,and the torque/quality ratio of the double-stator motor is smaller than that of single-stator motor with their optimal split ratio separately. 展开更多
关键词 five-phase PMSM DOUBLE-STATOR single-stator split ratio electromagnetic torque
下载PDF
Analysis of Direct Torque Control for Marine Five-Phase Induction Motor
5
作者 Peiwen Dou Wei Xie Xiaohan Zhang 《Journal of Energy and Power Engineering》 2020年第8期259-267,共9页
Based on the principle of direct torque control,a DTC(Direct Torque Control)system with five-phase induction motor has been studied.Providing direct control of stator flux and electromagnetic torque by optimized volta... Based on the principle of direct torque control,a DTC(Direct Torque Control)system with five-phase induction motor has been studied.Providing direct control of stator flux and electromagnetic torque by optimized voltage vector,five-phase induction motor enhances flexibility of the invert states selection by increasing the number of voltage vectors,resulting in more precise control of stator flux and electromagnetic torque.The model of DTC for five-phase induction motor is constructed on equations and the method of approximate circle of torque track is used to conduct the simulation analysis of the system.The simulation results demonstrate that the DTC for five-phase induction motor control has merits of little calculation compared with vector control,simple structure,fast response and greater dynamic performance. 展开更多
关键词 five-phase induction motor DTC circular flux track MATLAB/SIMULINK
下载PDF
企业-顾客身份分化与商业生态圈形成——基于海尔集团创新创业的多案例研究 被引量:10
6
作者 王凤彬 郑腾豪 王树文 《管理学报》 CSSCI 北大核心 2019年第5期633-643,共11页
以企业与顾客共同的身份分化为切入点,探究生态圈商业模式形成中各方行动者之间的生克关系及其组合成的整体系统的形态特征和进化发展机制。基于嵌入海尔集团内3个创新创业典型案例的比较分析,以复制逻辑归纳出其商业生态圈形成中的行... 以企业与顾客共同的身份分化为切入点,探究生态圈商业模式形成中各方行动者之间的生克关系及其组合成的整体系统的形态特征和进化发展机制。基于嵌入海尔集团内3个创新创业典型案例的比较分析,以复制逻辑归纳出其商业生态圈形成中的行动主体构成及其基本关系架构,并透过"五元"异质要素间生、克两重关系的"悖论"式并存及其在关联要素间的传递性,揭示"五行"生态圈形成的系统内生力量。研究结果印证了中国传统"五行学说"对当代商界创新创业实践的解释力,并将施动者和受动者间正负向关系交织的考察注入企业和顾客角色多样性理论研究中。 展开更多
关键词 生克关系 角色多样性 五行系统 商业生态圈
下载PDF
Research on Torque Ripple Under Healthy and Open-Circuit Fault-Tolerant Conditions in a PM Multiphase Machine 被引量:4
7
作者 Ali Akay Paul Lefley 《CES Transactions on Electrical Machines and Systems》 CSCD 2020年第4期349-359,共11页
In this paper,research into torque ripple production has been undertaken for both the healthy and open-circuit faulttolerant conditions of a five-phase permanent magnet(PM)machine by using the instantaneous power(I-Po... In this paper,research into torque ripple production has been undertaken for both the healthy and open-circuit faulttolerant conditions of a five-phase permanent magnet(PM)machine by using the instantaneous power(I-Power)approach.When only the fundamental component of the phase currents is applied to the phase windings,it has been shown that the 9th and 11th harmonics of the back-electromotive force(back-EMF)causes torque ripples in a five-phase PM machine and its frequency is ten times the frequency of the fundamental phase currents.When the combined fundamental and third harmonic components of the phase currents are applied to the phase windings,it has been shown that the 7th and 13th harmonic of the back-electromotive force(back-EMF)causes additional torque ripples in a five-phase PM machine.These torque ripples under fault-tolerant conditions have been analyzed analytically,as well.It has been proven that there are interactions between the fundamental component of current and the third harmonic component of the back-EMF and vice versa.These interactions cause torque ripples.A finite element analysis(FEA)model of the five-phase PM machine has been done to validate the analytical results. 展开更多
关键词 five-phase harmonic current injection multiphase machine permanent magnet machine torque ripple
下载PDF
Field-Oriented Control and Direct Torque Control for a Five-Phase Fault-Tolerant Flux-Switching Permanent-Magnet Motor 被引量:2
8
作者 Binyu Wu Dezhi Xu +2 位作者 Jinghua Ji Wenxiang Zhao Qingwang Jiang 《Chinese Journal of Electrical Engineering》 CSCD 2018年第4期48-56,共9页
This paper presents a comparative performance analysis of a new five-phase fault-tolerant flux-switching permanent-magnet(FT-FSPM)motor for high-reliability applications under the two most popular control schemes,name... This paper presents a comparative performance analysis of a new five-phase fault-tolerant flux-switching permanent-magnet(FT-FSPM)motor for high-reliability applications under the two most popular control schemes,namely,field-oriented control(FOC)and direct torque control(DTC)based on stator-flux orientation.Firstly,the new motor topology and structural characteristics are briefly presented.Secondly,the d-and q-axis for the FT-FSPM motor are defined,which is crucial to the mathematical model and control scheme,and the mathematical models are derived.Then,two control schemes,i.e.,FOC and DTC,and the main system are proposed.The operational principles of the two control schemes are presented,and space vector pulse width modulation(SVPWM)based on four neighboring vectors is adopted to reduce current harmonics and torque ripples.Finally,the simulated and experimental results are given,and performance analysis of the two control schemes are compared and discussed.The results reveal that FOC scheme has the sinusoidal phase current and low torque ripples,while the DTC scheme has fast dynamic response,verifying the effectiveness of the two proposed control schemes.This paper is a primary investigation for more possible improvements in the control schemes of the five-phase FS-FTPM motor. 展开更多
关键词 FLUX-SWITCHING five-phase motor permanent-magnet motor filed-oriented control direct torque control
原文传递
Fault-tolerant Deadbeat Model Predictive Current Control for a Five-phase PMSM with Improved SVPWM 被引量:1
9
作者 Suleman Saeed Wenxiang Zhao +2 位作者 Huanan Wang Tao Tao Faisal Khan 《Chinese Journal of Electrical Engineering》 CSCD 2021年第3期111-123,共13页
The main drawbacks of traditional finite set model predictive control are high computational load,large torque ripple,and variable switching frequency.A less complex deadbeat(DB)model predictive current control(MPCC)w... The main drawbacks of traditional finite set model predictive control are high computational load,large torque ripple,and variable switching frequency.A less complex deadbeat(DB)model predictive current control(MPCC)with improved space vector pulse-width modulation(SVPWM)under a single-phase open-circuit fault is proposed.The proposed method predicts the reference voltage vector in the a-β subspace by employing the deadbeat control principle on the machine predictive model;thus,the exhaustive exploration procedure is avoided to relieve the computational load.To perform the constant switching frequency operation and achieve better steady-state performance,a modified SVPWM strategy is developed with the same conventional structure,which modulates the reference voltage vector.This new approach is based on a redesigned and adjusted post-fault virtual voltage vector space distribution that eliminates the y-axis harmonic components in the x-y subspace and ensures the generation of symmetrical PWM pulses.Meanwhile,the combined merits of the DB,MPCC,and SVPWM methods are realized.To verify the effectiveness of the proposed control scheme,comparative experiments are performed on a five-phase permanent magnet synchronous motor(PMSM)drive system. 展开更多
关键词 five-phase FAULT-TOLERANT permanent magnet deadbeat model predictive control space vector modulation
原文传递
Dual-frequency Discontinuous Space Vector Pulse Width Modulation for Five-phase Voltage Source Inverters with Harmonic Injection
10
作者 Tianyu Pu Feifei Bu +1 位作者 Haijun Xu Wenxin Huang 《CSEE Journal of Power and Energy Systems》 SCIE CSCD 2021年第3期665-675,共11页
This paper proposes a dual-frequency discontinuous space vector pulse width modulation(DFDSVPWM)for a five-phase voltage source inverter with harmonic injection.In this modulation,for dual-frequency voltage output and... This paper proposes a dual-frequency discontinuous space vector pulse width modulation(DFDSVPWM)for a five-phase voltage source inverter with harmonic injection.In this modulation,for dual-frequency voltage output and reduction of switching losses,two different zero-vector-inserted modes are flexibly employed by alternatively using two types of zero vectors.Based on the comparison with continuous SVPWM,the idea and principle of the proposed DFDSVPWM are analyzed and an example of PWM signals for one bridge is also presented.For switching losses analysis,the impact factors and the calculation method are investigated and the corresponding implementation is given as well.The simulation and experimental results from a prototype verify the correctness and effectiveness of the proposed modulation and it has the advantages of outputting dual-frequency voltage and reducing switching losses. 展开更多
关键词 Discontinuous space vector pulse width modulation dual frequency five-phase voltage source inver terharmonic injection switching losses
原文传递
Microstructures and dynamic processes within the five-phase system:Regarding COVID-19 as a complex system
11
作者 Fengbin Wang Xue Zhang 《Frontiers of Business Research in China》 2020年第3期303-323,共21页
The research uses the development of 2019 novel coronavirus disease(COVID-19)in the human body as an example to explore the microstructures and dynamic processes of a concise complex system from the lens of the five-p... The research uses the development of 2019 novel coronavirus disease(COVID-19)in the human body as an example to explore the microstructures and dynamic processes of a concise complex system from the lens of the five-phase system.Based on the structural balance theory and system dynamics,the research finds that Iransitive triads and cyclic triads in the fivephase system are both imbalanced.The integration of these differentiated triads comprises of a balaneed intermediate form in the shape of quadrangular cycles.These cycles serve as microstructures of the five-phase system,due to the inherent balancing feedback mechanism,and support the generation of resultants.The alter nation of quadra ngular cycles drives the spirali ng development of the whole system.By orderly and regular in terweaving of sig ned directed links,the research provides a holistic,process-oriented demonstrati on for the developme nt processes of COVID-19.It clarifies that the esse nee of the five-phase system is phase-tra nsition processes with the quadrangular cycle as carrier and supporter,rather than the static aggregati on of five elements.The research deep ens the understanding of system non linearity by visualizi ng the circular causality and promotes the academic dialogue between the Western process theory and the Chinese inherited notion of the fivephase system. 展开更多
关键词 five-phase system 2019 novel coronavirus disease(COVID-19) Balancing feedback Microstructure Spiraling process
原文传递
Short-circuit fault-tolerant control for five-phase fault-tolerant permanent magnet motors with trapezoidal back-EMF
12
作者 Qian Chen Yuhang Xia +2 位作者 Jiabin Wang Wenxiang Zhao Guohai Liu 《Fundamental Research》 CAS 2022年第6期964-973,共10页
When a short-circuit fault occurs in a phase,the faulty phase needs to be removed artificially from the system because of the loss of the capability to generate torque.In this case,both the short-circuit current and p... When a short-circuit fault occurs in a phase,the faulty phase needs to be removed artificially from the system because of the loss of the capability to generate torque.In this case,both the short-circuit current and phase-loss fault would generate additional torque ripples.In this study,a novel fault-tolerant control strategy is introduced to achieve low torque ripple operation of five-phase fault-tolerant permanent magnet synchronous motors with trapezoidal back electromotive force(FTPMSM-TEMF)in the event of a short-circuit fault.The key concept of this method is to compensate for the torque ripples caused by the short-circuit current and the adverse effect of the phase-loss.Based on the torque expression under fault conditions,the torque ripple caused by the short-circuit current can be offset by injecting a certain pulsating component into the torque expression in the phase-loss condition.This would result in smooth operation under fault conditions.Moreover,to track the fault-tolerant alternating currents,the model of the deadbeat current predictive control is extended and restructured for the fault condition.The effectiveness and feasibility of the proposed fault-tolerant strategy are verified by experimental results. 展开更多
关键词 Short-circuit fault five-phase fault-tolerant permanent magnet synchronous motor Trapezoidal back electromotive force FAULT-TOLERANT Deadbeat current predictive control
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部