A semi-empirical detector response function(DRF)model is established to fit characteristic X-ray peaks recorded in Si-PIN spectra,which is mainly composed of four components:a truncated step function,a Gaussian-shaped...A semi-empirical detector response function(DRF)model is established to fit characteristic X-ray peaks recorded in Si-PIN spectra,which is mainly composed of four components:a truncated step function,a Gaussian-shaped full-energy peak,a Gaussian-shaped Si escape peak and an exponential tail.A simple but useful statistical distribution-based analytic method(SDA)is proposed to achieve accurate values of standard deviation for characteristic X-ray peaks.And the values of the model parameters except for the standard deviation are obtained by weighted least-squares fitting of the pulse-height spectra from a number of pure-element samples.A Monte Carlo model is also established to simulate the X-ray measurement setup.The simulated flux spectrum can be transformed by Si-PIN detector response function to real pulse height spectrum as studied in this work.Finally,the fitting result for a copper alloy sample was compared with experimental spectra,and the validity of the present method was demonstrated.展开更多
The readout electronics for a prototype soft X-ray spectrometer based on silicon drift detector(SDD),for precisely measuring the energy and arrival time of X-ray photons is presented in this paper.The system mainly co...The readout electronics for a prototype soft X-ray spectrometer based on silicon drift detector(SDD),for precisely measuring the energy and arrival time of X-ray photons is presented in this paper.The system mainly consists of two parts,i.e.,an analog electronics section(including a pre-amplifier,a signal shaper and filter,a constant fraction timing circuit,and a peak hold circuit)and a digital electronics section(including an ADC and a TDC).Test results with X-ray sources show that an energy dynamic range of 1-10 keV with an integral nonlinearity of less than 0.1%can be achieved,and the energy resolution is better than 160 eV @ 5.9 keV FWHM.Using a waveform generator,test results also indicate that time resolution of the electronics system is about 3.7 ns,which is much less than the transit time spread of SDD(<100 ns)and satisfies the requirements of future applications.展开更多
Significant advancement in thin-film cadmium telluride (CdTe) deposition techniques in recent years has made this material attractive for the development of low-cost large area detector. Here we evaluate the intrinsic...Significant advancement in thin-film cadmium telluride (CdTe) deposition techniques in recent years has made this material attractive for the development of low-cost large area detector. Here we evaluate the intrinsic performance of the detector for a range of energies relevant to diagnostic imaging applications, such as fluoroscopy. The input x-ray spectra for a set of tube potentials ranging from 70 to 140 kVp were computed with the tungsten anode spectral model using interpolating polynomials (TASMIP) based on the measured output of our diagnostic x-ray simulator. Frequency-dependent detector performance analysis was conducted through Monte Carlo simulations of energy deposition within the detector. Intrinsic modulation transfer functions (MTF), noise power spectra (NPS), and detective quantum efficiencies (DQE) were computed for a set of CdTe detectors of varying thickness, from 100 to 1000 μm. MTF behavior at higher frequencies was affected by thickness and input energy, NPS increased with film thickness and energy, and the resultant DQE(f) decreased with increasing the input energy, but increased with the thickness of the detector. We found that the optimal thickness of CdTe under diagnostic x-ray beam is in the range of 300 to 600 μm. Physical properties of CdTe, such as the high atomic number and density, used in direct detection configuration, together with the recently established thin-film manufacturing techniques makes this technology a promising photoconductor for large area diagnostic flat panel imaging.展开更多
X-Ray sources, detectors and optical components are now used in a wide range of applications. What is crucial is the absolute calibration of such devices to permit a quantitative assessment of the system under study. ...X-Ray sources, detectors and optical components are now used in a wide range of applications. What is crucial is the absolute calibration of such devices to permit a quantitative assessment of the system under study. A new X-ray laboratory has been built in Frascati (ENEA) to develop diagnostics for nuclear fusion experiments and study applications of these X-ray techniques in other domains, like new material science, non destructive tests and so on. An in-house developed selfconsistent calibration procedure is described that permits the absolute calibration of sources (X-ray emitted fluxes) and detectors (detection efficiencies) as function of the X-ray photon energy, in the range 2 - 120 keV. The calibration procedure involves the use of an in-house developed code that also predicts the spectral response of any detector in any experimental condition that can be setup in the laboratory. The procedure has been then applied for the calibration and characterisation of gas and solid state imaging detectors, such as Medipix-2, GEM gas detector, CCD camera, Cd-Te C-MOS imager, demonstrating the versatility of the method developed here.展开更多
To obtain two kinds of tomograms at two different X-ray energy ranges simultaneously, we have constructed a dual-energy X-ray photon counter with a lutetium-oxyorthosilicate photomultiplier detector system, three comp...To obtain two kinds of tomograms at two different X-ray energy ranges simultaneously, we have constructed a dual-energy X-ray photon counter with a lutetium-oxyorthosilicate photomultiplier detector system, three comparators, two microcomputers, and two frequency-voltage converters. X-ray photons are detected using the detector system, and the event pulses are input to three comparators simultaneously to determine threshold energies. At a tube voltage of 100 kV, the three threshold energies are 16, 35 and 52 keV, and two energy ranges are 16 - 35 and 52 - 100 keV. X-ray photons in the two ranges are counted using microcomputers, and the logical pulses from the two microcomputers are input to two frequency-voltage converters. In dual-energy computed tomography (CT), the tube voltage and current were 100 kV and 0.29 mA, respectively. Two tomograms were obtained simultaneously at two energy ranges. The energy ranges for gadolinium-L-edge and K-edge CT were 16 - 35 and 52 - 100 keV, respectively. The maximum count rate of dual-energy CT was 105 kilocounts per second with energies ranging from 16 to 100 keV, and the exposure time for tomography was 19.6 min.展开更多
Photon counting detectors(PCDs) have attained w ide use in X-ray imaging for various preclinical and clinical applications in the past decade. This paper briefly review s the preclinical and clinical applications of P...Photon counting detectors(PCDs) have attained w ide use in X-ray imaging for various preclinical and clinical applications in the past decade. This paper briefly review s the preclinical and clinical applications of PCDs based X-ray imaging systems.Starting with an introduction of X-ray single photon detection mechanism,the brief review first describes tw o major advantages of utilizing PCDs: photon energy resolving capability and electronic noise elimination. Compared to energy integrating detectors(EIDs),the aforementioned advantages make PCDs more favorable in X-ray imaging with profound benefits such as enhanced tissue contrast,decreased image noise,increased signal to noise ratio,decreased radiation dose to the small animals and patients,and more accurate material decomposition. The utilizations of PCDs in X-ray projection radiography and computed tomography(CT)including micro-CT,dedicated breast CT,K-edge CT,and clinical CT are then review ed for the imaging applications ranging from phantoms to small animals and humans. In addition,optimization methods aiming to improve the imaging performance using PCDs are briefly review ed. PCDs are not flaw less though,and their limitations are also discussed in this review. Nevertheless,PCDs may continuously contribute to the advancement of X-ray imaging techniques in future preclinical and clinical applications.展开更多
p-i-n Al_(x)Ga_(1−x)As/GaAs detectors with graded compositions and graded doping were grown and prepared.From the current-voltage and capacitance-voltage measurement results,the devices had good p-n junction diode cha...p-i-n Al_(x)Ga_(1−x)As/GaAs detectors with graded compositions and graded doping were grown and prepared.From the current-voltage and capacitance-voltage measurement results,the devices had good p-n junction diode characteristics,and the electric field strength under an unbiased voltage was 1.7×10^(5) Vcm^(-1).The full width at half maximum and charge collection efficiency of the detectors obtained from energy spectrum measurements of 5.48-MeV alpha particles were 3.04 and approximately 93%,respectively.In this study,we created the most advanced and promising state-of-the-art unbiased detector reported to date.展开更多
基金Supported by National Natural Science Foundation of China(Nos.40974065 and 41025015)Scientific and Technological Innovative Team in Sichuan Province(No.2011JTD0013)"863"Program of China(No.2012AA063501)
文摘A semi-empirical detector response function(DRF)model is established to fit characteristic X-ray peaks recorded in Si-PIN spectra,which is mainly composed of four components:a truncated step function,a Gaussian-shaped full-energy peak,a Gaussian-shaped Si escape peak and an exponential tail.A simple but useful statistical distribution-based analytic method(SDA)is proposed to achieve accurate values of standard deviation for characteristic X-ray peaks.And the values of the model parameters except for the standard deviation are obtained by weighted least-squares fitting of the pulse-height spectra from a number of pure-element samples.A Monte Carlo model is also established to simulate the X-ray measurement setup.The simulated flux spectrum can be transformed by Si-PIN detector response function to real pulse height spectrum as studied in this work.Finally,the fitting result for a copper alloy sample was compared with experimental spectra,and the validity of the present method was demonstrated.
基金supported by the National Natural Science Foundation of China(Grant No.11205154)
文摘The readout electronics for a prototype soft X-ray spectrometer based on silicon drift detector(SDD),for precisely measuring the energy and arrival time of X-ray photons is presented in this paper.The system mainly consists of two parts,i.e.,an analog electronics section(including a pre-amplifier,a signal shaper and filter,a constant fraction timing circuit,and a peak hold circuit)and a digital electronics section(including an ADC and a TDC).Test results with X-ray sources show that an energy dynamic range of 1-10 keV with an integral nonlinearity of less than 0.1%can be achieved,and the energy resolution is better than 160 eV @ 5.9 keV FWHM.Using a waveform generator,test results also indicate that time resolution of the electronics system is about 3.7 ns,which is much less than the transit time spread of SDD(<100 ns)and satisfies the requirements of future applications.
文摘Significant advancement in thin-film cadmium telluride (CdTe) deposition techniques in recent years has made this material attractive for the development of low-cost large area detector. Here we evaluate the intrinsic performance of the detector for a range of energies relevant to diagnostic imaging applications, such as fluoroscopy. The input x-ray spectra for a set of tube potentials ranging from 70 to 140 kVp were computed with the tungsten anode spectral model using interpolating polynomials (TASMIP) based on the measured output of our diagnostic x-ray simulator. Frequency-dependent detector performance analysis was conducted through Monte Carlo simulations of energy deposition within the detector. Intrinsic modulation transfer functions (MTF), noise power spectra (NPS), and detective quantum efficiencies (DQE) were computed for a set of CdTe detectors of varying thickness, from 100 to 1000 μm. MTF behavior at higher frequencies was affected by thickness and input energy, NPS increased with film thickness and energy, and the resultant DQE(f) decreased with increasing the input energy, but increased with the thickness of the detector. We found that the optimal thickness of CdTe under diagnostic x-ray beam is in the range of 300 to 600 μm. Physical properties of CdTe, such as the high atomic number and density, used in direct detection configuration, together with the recently established thin-film manufacturing techniques makes this technology a promising photoconductor for large area diagnostic flat panel imaging.
文摘X-Ray sources, detectors and optical components are now used in a wide range of applications. What is crucial is the absolute calibration of such devices to permit a quantitative assessment of the system under study. A new X-ray laboratory has been built in Frascati (ENEA) to develop diagnostics for nuclear fusion experiments and study applications of these X-ray techniques in other domains, like new material science, non destructive tests and so on. An in-house developed selfconsistent calibration procedure is described that permits the absolute calibration of sources (X-ray emitted fluxes) and detectors (detection efficiencies) as function of the X-ray photon energy, in the range 2 - 120 keV. The calibration procedure involves the use of an in-house developed code that also predicts the spectral response of any detector in any experimental condition that can be setup in the laboratory. The procedure has been then applied for the calibration and characterisation of gas and solid state imaging detectors, such as Medipix-2, GEM gas detector, CCD camera, Cd-Te C-MOS imager, demonstrating the versatility of the method developed here.
文摘To obtain two kinds of tomograms at two different X-ray energy ranges simultaneously, we have constructed a dual-energy X-ray photon counter with a lutetium-oxyorthosilicate photomultiplier detector system, three comparators, two microcomputers, and two frequency-voltage converters. X-ray photons are detected using the detector system, and the event pulses are input to three comparators simultaneously to determine threshold energies. At a tube voltage of 100 kV, the three threshold energies are 16, 35 and 52 keV, and two energy ranges are 16 - 35 and 52 - 100 keV. X-ray photons in the two ranges are counted using microcomputers, and the logical pulses from the two microcomputers are input to two frequency-voltage converters. In dual-energy computed tomography (CT), the tube voltage and current were 100 kV and 0.29 mA, respectively. Two tomograms were obtained simultaneously at two energy ranges. The energy ranges for gadolinium-L-edge and K-edge CT were 16 - 35 and 52 - 100 keV, respectively. The maximum count rate of dual-energy CT was 105 kilocounts per second with energies ranging from 16 to 100 keV, and the exposure time for tomography was 19.6 min.
基金supported in part by a grant from the University of Oklahoma Charles and Peggy Stephenson Cancer Center funded by the Oklahoma Tobacco Settlement Endowment Trust
文摘Photon counting detectors(PCDs) have attained w ide use in X-ray imaging for various preclinical and clinical applications in the past decade. This paper briefly review s the preclinical and clinical applications of PCDs based X-ray imaging systems.Starting with an introduction of X-ray single photon detection mechanism,the brief review first describes tw o major advantages of utilizing PCDs: photon energy resolving capability and electronic noise elimination. Compared to energy integrating detectors(EIDs),the aforementioned advantages make PCDs more favorable in X-ray imaging with profound benefits such as enhanced tissue contrast,decreased image noise,increased signal to noise ratio,decreased radiation dose to the small animals and patients,and more accurate material decomposition. The utilizations of PCDs in X-ray projection radiography and computed tomography(CT)including micro-CT,dedicated breast CT,K-edge CT,and clinical CT are then review ed for the imaging applications ranging from phantoms to small animals and humans. In addition,optimization methods aiming to improve the imaging performance using PCDs are briefly review ed. PCDs are not flaw less though,and their limitations are also discussed in this review. Nevertheless,PCDs may continuously contribute to the advancement of X-ray imaging techniques in future preclinical and clinical applications.
基金supported by the National Natural Science Foundation of China(No.61964001)General Project of Jiangxi Province Key R&D Program(No.20212BBG73012)+3 种基金Natural Science Foundation of Jiangxi Province(No.20192BAB207033)Key Scientific Research Projects of Henan Higher Education Institutions(No.22A490001)State Key Laboratory of Particle Detection and Electronics(No.SKLPDE-KF-2019)Jiangxi Provincial Postdoctoral Science Foundation(No.2019RC30).
文摘p-i-n Al_(x)Ga_(1−x)As/GaAs detectors with graded compositions and graded doping were grown and prepared.From the current-voltage and capacitance-voltage measurement results,the devices had good p-n junction diode characteristics,and the electric field strength under an unbiased voltage was 1.7×10^(5) Vcm^(-1).The full width at half maximum and charge collection efficiency of the detectors obtained from energy spectrum measurements of 5.48-MeV alpha particles were 3.04 and approximately 93%,respectively.In this study,we created the most advanced and promising state-of-the-art unbiased detector reported to date.