AIM:To compare the cost and accuracy of upper gastrointestinal(GI)X-ray and upper endoscopy for diagnosis of gastric cancer using data from the 2002-2004 Korean National Cancer Screening Program(NCSP). METHODS:The stu...AIM:To compare the cost and accuracy of upper gastrointestinal(GI)X-ray and upper endoscopy for diagnosis of gastric cancer using data from the 2002-2004 Korean National Cancer Screening Program(NCSP). METHODS:The study population included 1 503 646 participants in the 2002-2004 stomach cancer screening program who underwent upper GI X-ray or endoscopy.The accuracy of screening was defined as the probability of detecting gastric cancer.We calculated the probability by merging data from the NCSP and the Korea Central Cancer Registry.We estimated the direct costs of the medical examination and the tests for up- per GI X-ray,upper endoscopy,and biopsy. RESULTS:The probability of detecting gastric cancervia upper endoscopy was 2.9-fold higher than via upper GI X-ray.The unit costs of screening using upper GI X-ray and upper endoscopy were$32.67 and$34.89, respectively.In 2008,the estimated cost of identifying one case of gastric cancer was$53094.64 using upper GI X-ray and$16 900.43 using upper endoscopy.The cost to detect one case of gastric cancer was the same for upper GI X-ray and upper endoscopy at a cost ratio of 1:3.7. CONCLUSION:Upper endoscopy is slightly more costly to perform,but the cost to detect one case of gastric cancer is lower.展开更多
[Objectives]This study was conducted to explore the application value of X ray in the diagnosis of poultry fatty liver.[Methods]Serum biochemical tests were performed on laying hens with suspected fatty liver.The X-ra...[Objectives]This study was conducted to explore the application value of X ray in the diagnosis of poultry fatty liver.[Methods]Serum biochemical tests were performed on laying hens with suspected fatty liver.The X-ray liver images of the left lateral position were observed.And the liver traits were observed by anatomy.[Results]The increase in liver space occupying lesion observed by X-ray photography was consistent with the increase in liver volume observed by anatomy.The biochemical test showed slight liver function abnormalities.[Conclusions]X-ray examination can be used for the auxiliary diagnosis of poultry fatty liver.展开更多
Effective prevention and management of osteoporosis would require suitable methods for population screenings and early diagnosis. Current clinicallyavailable diagnostic methods are mainly based on the use of either X-...Effective prevention and management of osteoporosis would require suitable methods for population screenings and early diagnosis. Current clinicallyavailable diagnostic methods are mainly based on the use of either X-rays or ultrasound(US). All X-ray based methods provide a measure of bone mineral density(BMD), but it has been demonstrated that other structural aspects of the bone are important in determining fracture risk, such as mechanical features and elastic properties, which cannot be assessed using densitometric techniques. Among the most commonly used techniques, dual X-ray absorptiometry(DXA) is considered the current 'gold standard' for osteoporosis diagnosis and fracture risk prediction. Unfortunately, as other X-ray based techniques, DXA has specific limitations(e.g., use of ionizing radiation, large size of the equipment, high costs, limited availability) that hinder its application for population screenings and primary care diagnosis. This has resulted in an increasing interest in developing reliable pre-screening tools for osteoporosis such as quantitative ultrasound(QUS) scanners, which do not involve ionizing radiation exposure and represent a cheaper solution exploiting portable and widely available devices. Furthermore, the usefulness of QUS techniques in fracture risk prediction has been proven and, with the last developments, they are also becoming a more and more reliable approach for assessing bone quality. However, the US assessment of osteoporosis is currently used only as a pre-screening tool, requiring a subsequent diagnosis confirmation by means of a DXA evaluation. Here we illustrate the state of art in the early diagnosis of this 'silent disease' and show up recent advances for its prevention and improved management through early diagnosis.展开更多
Background: The plain abdominal x-ray is one of the commonly requested investigations in the children emergency room, paediatric surgical ward and neonatal wards. The short interval required to carry out this investig...Background: The plain abdominal x-ray is one of the commonly requested investigations in the children emergency room, paediatric surgical ward and neonatal wards. The short interval required to carry out this investigative procedure and obtain results makes it the first imaging modality used to unravel the different causes of acute abdominal conditions in children. The safety of abdominal x-ray in children makes it attractive for use in paediatric surgical practice as part of routine work-up for undifferentiated acute abdominal conditions and also to diagnose specific causes of acute abdomen in children. Setting: Olabisi Onabanjo University Teaching Hospital, Sagamu, Ogun State. Objectives: Evaluation of the role of plain abdominal x-ray in diagnosing common acute abdominal conditions in children. Materials and method: Patients admitted to the children emergency room, paediatric surgical wards, children’s ward and neonatal ward who had plain abdominal x-ray as part of their diagnostic work-up were included in the study. They were studied prospectively between March 2011 and April 2021. Results: Three Hundred and Ninety-nine patients who had plain abdominal x-rays as part of their diagnostic work-up were studied. Males were 240 while females were 159, a male to female ratio of 1.5:1. The patients were aged between 1 day to 16 years. Differential diagnoses made with plain abdominal x-ray were intestinal obstruction in 298, perforated viscus 69 patients, intra-abdominal masses 13 patients and location of intra-abdominal foreign body 14. Intestinal obstruction cases in which plain abdominal x-ray played a role in their diagnosis and management included the following: intussusception 66, neonatal sepsis 60, malrotation 48, intestinal atresia 42, anorectal malformation 32, hirschsprung’s disease in 30 cases, pyloric stenosis 24, obstructed hernia 22, post-operative adhesions 16 and intestinal helminthiasis 12. Perforated viscus accounted for 69 indications. Out of these indications, perforated gut in intussusception 19, perforated typhoid ileitis was responsible in 13 cases, gut perforation in blunt abdominal trauma 8, perforation in strangulated hernia 11 cases, perforated gut in malrotation 7, ceacal perforation in hirschsprugs disease 6 and colonic perforation in necrotizing enterocolitis 5 cases. Conclusion: Plain abdominal x-ray remains a role to play in the differential diagnosis and management of common paediatric acute abdominal conditions.展开更多
Polymerase chain reaction (PCR) technique combined with direct detection by silver staining on denaturing DNA sequencing gel was used to analyze the (CGG)n repeats within the FMR1 gene on 169 suspected patients wit...Polymerase chain reaction (PCR) technique combined with direct detection by silver staining on denaturing DNA sequencing gel was used to analyze the (CGG)n repeats within the FMR1 gene on 169 suspected patients with mental retardation and 33 kindreds of 6 fragile X families. The results showed that : (1) No PCR products were detected in 3 males in the suspected group. (2) In the fragile X family studies, the 5 male probands failed to show any PCR products. (3) Diplex PCR with the primers flanking the FRAXE locus was used to serve as an internal control for the 8 above mentioned males and only normal products of the FRAXE locus were detected, indicating that the possibility of false negative results of the FRAXA locus could be eliminated. These findings suggested that analysis of (CGG)n repeat within the FMR1 gene by PCR technique could efficiently detect premutation carriers and that negative PCR products in mentally retarded males might highly imply the diagnosis of fragile X syndrome after the false negative results have been excluded by diplex PCR. This PCR assay is suitable for the screening and diagnosis of fragile X syndrome in a large number of populations due to its rapidity, simplicity, stability and reliability.展开更多
Four cases of proximal femoral focal deficiency (PFFD) in an otherwise healthy infant are described. Antenatal diagnosis was made at 27, 23, 23 and 18 weeks of gestation by routine ultrasound (US) examination. Compute...Four cases of proximal femoral focal deficiency (PFFD) in an otherwise healthy infant are described. Antenatal diagnosis was made at 27, 23, 23 and 18 weeks of gestation by routine ultrasound (US) examination. Computer Tomography (CT) was performed after 30 weeks of gestation and confirmed the images obtained by US. The diagnosis was confirmed after delivery. These cases illustrate the importance of combining US and CT to improve accuracy of prenatal diagnosis of skeletal disorders.展开更多
X-ray is irradiated in some wood composites(multi-layer particleboard.sin-gle-layer particleboard,reconsolidated wood,).According to the gray degree principle(0-255 grade degree)and the corresponding relation between ...X-ray is irradiated in some wood composites(multi-layer particleboard.sin-gle-layer particleboard,reconsolidated wood,).According to the gray degree principle(0-255 grade degree)and the corresponding relation between density and gray,X-raynegatives are scanned.The numbers and pictures of every degree density are obtained andaccurate composite densities are counted.展开更多
Review of X-ray dark-field imaging under development is presented. Its goal is its application to clinical diagnosis of organs that have been invisible by the ordinary techniques. In order to clinically visualize tiss...Review of X-ray dark-field imaging under development is presented. Its goal is its application to clinical diagnosis of organs that have been invisible by the ordinary techniques. In order to clinically visualize tissues in detail one needs high contrast and high spatial resolution say ~50 μm. This X-ray optics comprises a Bragg asymmetric monochro-collimator and a Bragg case or a Laue case filter with capability of analyzing angle in a parallel position. Their diffraction index is 4,4,0 and the X-ray energy 35 keV (λ= 0.0354 nm). The filter has 0.6 mm thickness in the Bragg case or 1.075 mm or 2.15 mm thickness in the Laue case. Under this condition only the refracted X-rays from object can transmit through the filter while the beam that may receive absorption and/or phase change will not. Soft tissues at human joints thus taken show high contrast images so that the DFI is promising for clinical diagnosis. Preliminary X-ray absorption images of another clinical candidates of ear bones are also shown.展开更多
A ray tracing method is introduced for helping adjustment and spectra analysis of the grazing incidence flat-field imaging soft X-ray spectrometer. For a single point source, the spectra images obtained by separate co...A ray tracing method is introduced for helping adjustment and spectra analysis of the grazing incidence flat-field imaging soft X-ray spectrometer. For a single point source, the spectra images obtained by separate components, the toroidal mirror, and the grazing incidence flat-field concave grating with varied line spaces are given respectively. The calculated spectral images of the single point source by the spectrometer are also given for comparison with measurements with different experimental alignments.展开更多
We conducted experiments of oversensing generation of pacemaker (PM) and X-irradiation direction dependency of PM, and examined the oversensing suppression method, using 8 different types of PMs. It was found out from...We conducted experiments of oversensing generation of pacemaker (PM) and X-irradiation direction dependency of PM, and examined the oversensing suppression method, using 8 different types of PMs. It was found out from this experiment that oversensing would occur when some conditions (X-irradiation direction, X-irradiation intensity) are met. Oversensing occurred with the most low irradiation conditions (kV × mA) when PM was irradiated at 90° (vertically to C-MOS;Complementary Metal Oxide Semiconductor). The acuter the angle of irradiation is (α > 90° < α), the higher the irradiation conditions (kV × mA) at which oversensing start to occur. In plain X-ray photography, oversensing was confirmed under the irradiation conditions of (cervical spine, thoracic spine, lateral thoracic spine, rib, shoulder joint, collarbone, humerus, and chest).Once the irradiation angle and irradiation conditions (kV × mA) are available, oversensing is predictable to some extent. Our findings will help to predict oversensing generation of plain X-ray photography and suppress oversensing. Oversensing can be suppressed in most of the radiography by lowering tube current to 100 mA, but a 1.0 mm High-Density Tungsten Sheet must be put on PM in high tube voltage radiography.展开更多
The article is to study the development of computer-aided design of X-ray microtomography—the device for investigating the structure and construction of three-dimensional images of organic and inorganic objects on th...The article is to study the development of computer-aided design of X-ray microtomography—the device for investigating the structure and construction of three-dimensional images of organic and inorganic objects on the basis of shadow projections. This article provides basic information regarding CAD of X-ray microtomography and a scheme consisting of three levels. The article also shows basic relations of X-ray computed tomography, the generalized scheme of an X-ray microtomographic scanner. The methods of X-ray imaging of the spatial microstructure and morphometry of materials are described. The main characteristics of an X-ray microtomographic scanner, the X-ray source, X-ray optical elements and mechanical components of the positioning system are shown. The block scheme and software functional scheme for intelligent neural network system of analysis of the internal microstructure of objects are presented. The method of choice of design parameters of CAD of X-ray microtomography aims at improving the quality of design and reducing costs of it. It is supposed to reduce the design time and eliminate the growing number of engineers involved in development and construction of X-ray microtomographic scanners.展开更多
基金Supported by Grant No.0710131 from the National Cancer Center Research Fund
文摘AIM:To compare the cost and accuracy of upper gastrointestinal(GI)X-ray and upper endoscopy for diagnosis of gastric cancer using data from the 2002-2004 Korean National Cancer Screening Program(NCSP). METHODS:The study population included 1 503 646 participants in the 2002-2004 stomach cancer screening program who underwent upper GI X-ray or endoscopy.The accuracy of screening was defined as the probability of detecting gastric cancer.We calculated the probability by merging data from the NCSP and the Korea Central Cancer Registry.We estimated the direct costs of the medical examination and the tests for up- per GI X-ray,upper endoscopy,and biopsy. RESULTS:The probability of detecting gastric cancervia upper endoscopy was 2.9-fold higher than via upper GI X-ray.The unit costs of screening using upper GI X-ray and upper endoscopy were$32.67 and$34.89, respectively.In 2008,the estimated cost of identifying one case of gastric cancer was$53094.64 using upper GI X-ray and$16 900.43 using upper endoscopy.The cost to detect one case of gastric cancer was the same for upper GI X-ray and upper endoscopy at a cost ratio of 1:3.7. CONCLUSION:Upper endoscopy is slightly more costly to perform,but the cost to detect one case of gastric cancer is lower.
基金Supported by College Students’ Innovation Training Program of Tianjin City(201810061106)
文摘[Objectives]This study was conducted to explore the application value of X ray in the diagnosis of poultry fatty liver.[Methods]Serum biochemical tests were performed on laying hens with suspected fatty liver.The X-ray liver images of the left lateral position were observed.And the liver traits were observed by anatomy.[Results]The increase in liver space occupying lesion observed by X-ray photography was consistent with the increase in liver volume observed by anatomy.The biochemical test showed slight liver function abnormalities.[Conclusions]X-ray examination can be used for the auxiliary diagnosis of poultry fatty liver.
基金Supported by Partially funded by FESR P.O.Apulia Region 2007-2013-Action 1.2.4,No.3Q5AX31
文摘Effective prevention and management of osteoporosis would require suitable methods for population screenings and early diagnosis. Current clinicallyavailable diagnostic methods are mainly based on the use of either X-rays or ultrasound(US). All X-ray based methods provide a measure of bone mineral density(BMD), but it has been demonstrated that other structural aspects of the bone are important in determining fracture risk, such as mechanical features and elastic properties, which cannot be assessed using densitometric techniques. Among the most commonly used techniques, dual X-ray absorptiometry(DXA) is considered the current 'gold standard' for osteoporosis diagnosis and fracture risk prediction. Unfortunately, as other X-ray based techniques, DXA has specific limitations(e.g., use of ionizing radiation, large size of the equipment, high costs, limited availability) that hinder its application for population screenings and primary care diagnosis. This has resulted in an increasing interest in developing reliable pre-screening tools for osteoporosis such as quantitative ultrasound(QUS) scanners, which do not involve ionizing radiation exposure and represent a cheaper solution exploiting portable and widely available devices. Furthermore, the usefulness of QUS techniques in fracture risk prediction has been proven and, with the last developments, they are also becoming a more and more reliable approach for assessing bone quality. However, the US assessment of osteoporosis is currently used only as a pre-screening tool, requiring a subsequent diagnosis confirmation by means of a DXA evaluation. Here we illustrate the state of art in the early diagnosis of this 'silent disease' and show up recent advances for its prevention and improved management through early diagnosis.
文摘Background: The plain abdominal x-ray is one of the commonly requested investigations in the children emergency room, paediatric surgical ward and neonatal wards. The short interval required to carry out this investigative procedure and obtain results makes it the first imaging modality used to unravel the different causes of acute abdominal conditions in children. The safety of abdominal x-ray in children makes it attractive for use in paediatric surgical practice as part of routine work-up for undifferentiated acute abdominal conditions and also to diagnose specific causes of acute abdomen in children. Setting: Olabisi Onabanjo University Teaching Hospital, Sagamu, Ogun State. Objectives: Evaluation of the role of plain abdominal x-ray in diagnosing common acute abdominal conditions in children. Materials and method: Patients admitted to the children emergency room, paediatric surgical wards, children’s ward and neonatal ward who had plain abdominal x-ray as part of their diagnostic work-up were included in the study. They were studied prospectively between March 2011 and April 2021. Results: Three Hundred and Ninety-nine patients who had plain abdominal x-rays as part of their diagnostic work-up were studied. Males were 240 while females were 159, a male to female ratio of 1.5:1. The patients were aged between 1 day to 16 years. Differential diagnoses made with plain abdominal x-ray were intestinal obstruction in 298, perforated viscus 69 patients, intra-abdominal masses 13 patients and location of intra-abdominal foreign body 14. Intestinal obstruction cases in which plain abdominal x-ray played a role in their diagnosis and management included the following: intussusception 66, neonatal sepsis 60, malrotation 48, intestinal atresia 42, anorectal malformation 32, hirschsprung’s disease in 30 cases, pyloric stenosis 24, obstructed hernia 22, post-operative adhesions 16 and intestinal helminthiasis 12. Perforated viscus accounted for 69 indications. Out of these indications, perforated gut in intussusception 19, perforated typhoid ileitis was responsible in 13 cases, gut perforation in blunt abdominal trauma 8, perforation in strangulated hernia 11 cases, perforated gut in malrotation 7, ceacal perforation in hirschsprugs disease 6 and colonic perforation in necrotizing enterocolitis 5 cases. Conclusion: Plain abdominal x-ray remains a role to play in the differential diagnosis and management of common paediatric acute abdominal conditions.
文摘Polymerase chain reaction (PCR) technique combined with direct detection by silver staining on denaturing DNA sequencing gel was used to analyze the (CGG)n repeats within the FMR1 gene on 169 suspected patients with mental retardation and 33 kindreds of 6 fragile X families. The results showed that : (1) No PCR products were detected in 3 males in the suspected group. (2) In the fragile X family studies, the 5 male probands failed to show any PCR products. (3) Diplex PCR with the primers flanking the FRAXE locus was used to serve as an internal control for the 8 above mentioned males and only normal products of the FRAXE locus were detected, indicating that the possibility of false negative results of the FRAXA locus could be eliminated. These findings suggested that analysis of (CGG)n repeat within the FMR1 gene by PCR technique could efficiently detect premutation carriers and that negative PCR products in mentally retarded males might highly imply the diagnosis of fragile X syndrome after the false negative results have been excluded by diplex PCR. This PCR assay is suitable for the screening and diagnosis of fragile X syndrome in a large number of populations due to its rapidity, simplicity, stability and reliability.
文摘Four cases of proximal femoral focal deficiency (PFFD) in an otherwise healthy infant are described. Antenatal diagnosis was made at 27, 23, 23 and 18 weeks of gestation by routine ultrasound (US) examination. Computer Tomography (CT) was performed after 30 weeks of gestation and confirmed the images obtained by US. The diagnosis was confirmed after delivery. These cases illustrate the importance of combining US and CT to improve accuracy of prenatal diagnosis of skeletal disorders.
文摘X-ray is irradiated in some wood composites(multi-layer particleboard.sin-gle-layer particleboard,reconsolidated wood,).According to the gray degree principle(0-255 grade degree)and the corresponding relation between density and gray,X-raynegatives are scanned.The numbers and pictures of every degree density are obtained andaccurate composite densities are counted.
文摘Review of X-ray dark-field imaging under development is presented. Its goal is its application to clinical diagnosis of organs that have been invisible by the ordinary techniques. In order to clinically visualize tissues in detail one needs high contrast and high spatial resolution say ~50 μm. This X-ray optics comprises a Bragg asymmetric monochro-collimator and a Bragg case or a Laue case filter with capability of analyzing angle in a parallel position. Their diffraction index is 4,4,0 and the X-ray energy 35 keV (λ= 0.0354 nm). The filter has 0.6 mm thickness in the Bragg case or 1.075 mm or 2.15 mm thickness in the Laue case. Under this condition only the refracted X-rays from object can transmit through the filter while the beam that may receive absorption and/or phase change will not. Soft tissues at human joints thus taken show high contrast images so that the DFI is promising for clinical diagnosis. Preliminary X-ray absorption images of another clinical candidates of ear bones are also shown.
基金supported by the National Natural Science Foundation of China(Grant Nos.11221002,11274152,and 11074297)
文摘A ray tracing method is introduced for helping adjustment and spectra analysis of the grazing incidence flat-field imaging soft X-ray spectrometer. For a single point source, the spectra images obtained by separate components, the toroidal mirror, and the grazing incidence flat-field concave grating with varied line spaces are given respectively. The calculated spectral images of the single point source by the spectrometer are also given for comparison with measurements with different experimental alignments.
文摘We conducted experiments of oversensing generation of pacemaker (PM) and X-irradiation direction dependency of PM, and examined the oversensing suppression method, using 8 different types of PMs. It was found out from this experiment that oversensing would occur when some conditions (X-irradiation direction, X-irradiation intensity) are met. Oversensing occurred with the most low irradiation conditions (kV × mA) when PM was irradiated at 90° (vertically to C-MOS;Complementary Metal Oxide Semiconductor). The acuter the angle of irradiation is (α > 90° < α), the higher the irradiation conditions (kV × mA) at which oversensing start to occur. In plain X-ray photography, oversensing was confirmed under the irradiation conditions of (cervical spine, thoracic spine, lateral thoracic spine, rib, shoulder joint, collarbone, humerus, and chest).Once the irradiation angle and irradiation conditions (kV × mA) are available, oversensing is predictable to some extent. Our findings will help to predict oversensing generation of plain X-ray photography and suppress oversensing. Oversensing can be suppressed in most of the radiography by lowering tube current to 100 mA, but a 1.0 mm High-Density Tungsten Sheet must be put on PM in high tube voltage radiography.
文摘The article is to study the development of computer-aided design of X-ray microtomography—the device for investigating the structure and construction of three-dimensional images of organic and inorganic objects on the basis of shadow projections. This article provides basic information regarding CAD of X-ray microtomography and a scheme consisting of three levels. The article also shows basic relations of X-ray computed tomography, the generalized scheme of an X-ray microtomographic scanner. The methods of X-ray imaging of the spatial microstructure and morphometry of materials are described. The main characteristics of an X-ray microtomographic scanner, the X-ray source, X-ray optical elements and mechanical components of the positioning system are shown. The block scheme and software functional scheme for intelligent neural network system of analysis of the internal microstructure of objects are presented. The method of choice of design parameters of CAD of X-ray microtomography aims at improving the quality of design and reducing costs of it. It is supposed to reduce the design time and eliminate the growing number of engineers involved in development and construction of X-ray microtomographic scanners.