To study the stereostructure by X-ray and the technology of extracting acankoreanogenin from the leaves of Acanthopanax graeilistylus W. W. Smith (AGS), the crystal structure was measured with a Bruker APEX-Ⅱ area-...To study the stereostructure by X-ray and the technology of extracting acankoreanogenin from the leaves of Acanthopanax graeilistylus W. W. Smith (AGS), the crystal structure was measured with a Bruker APEX-Ⅱ area-detector diffractometer instrument and the technology of extracting in combination hydrolysis in situ (ECHS) was compared with these of traditional methods. The crystal belongs to the monoclinic system, space group P2b with unit cell parameters: a=(8.3652±0.0006) nm, b=(24.721±0.002) nm, and c=(14.5587±0.0011) nm, α=90°, β=97.850 (4) °, γ=90 °, V=2982.51 nm3, Dc= 1.179 mg/m3, and the molecular number (Z) of elementary structures was 2. The comparisons show that the extraction rate of acankoreanogenin with ECHS methods is much higher than that of traditional methods. Then, central composite design-response surface methodology (CCD-RSM) was adopted for optimizing the extraction rate of ECHS methods. The optimized values of extraction parameters are as follows: for the for extraction process of acid hydrolysis are that extraction time 110.8 min, solvent-herb ratio 11.5 and acid content 5.25%; the best extraction process of basic hydrolysis are that extract time 120 min, solvent-herb ratio 8.7 and the alkali content 8.79%. Finally, the extracts were purified with decolorizing carbon after alkali solution and acid-isolation and purity of acankoreanogenin was 98.7%.展开更多
2012 is a year of celebrate centenary of X-ray discovery information about Laue's (Fridrich and Knipping) experiment was This discovery spread quickly in different countries. The history of written in the paper. Al...2012 is a year of celebrate centenary of X-ray discovery information about Laue's (Fridrich and Knipping) experiment was This discovery spread quickly in different countries. The history of written in the paper. Also history mention of Laue's experiment in Russia was presented. The system group of X-ray diffraction was created in 1919/1920 in Petrograd (A. Ioffe, State Physical Technical Institute) and Moscow. Themes of research results, scientific newness and scientific rate were presented. The organization, political and other reasons which retarded the active progress of the method in 1930 were described. Initial stage of progress of the method in Russia-USSR was studied by historian of science partly. The reasons of it are: closed of scientific community, political system of country, Cyrillic barrier, etc.. This paper acquaints western scientific community with non-famous Russian materials on theme.展开更多
基金Project(11JJ2042)supported by the Natural Science Foundation of Hunan Province,ChinaProject supported by the "Twelfth Five-Year" Key Discipline of Hunan University of Chinese Medicine-Pharmaceutical Analysis Science,China+1 种基金Project(11K048)supported by the Innovation Platform and Open Foundation Program of Higher Colleges of Hunan Province,ChinaProject(K1207010-21)supported by the Changsha City Science and Technology Bureau Key Projects,China
文摘To study the stereostructure by X-ray and the technology of extracting acankoreanogenin from the leaves of Acanthopanax graeilistylus W. W. Smith (AGS), the crystal structure was measured with a Bruker APEX-Ⅱ area-detector diffractometer instrument and the technology of extracting in combination hydrolysis in situ (ECHS) was compared with these of traditional methods. The crystal belongs to the monoclinic system, space group P2b with unit cell parameters: a=(8.3652±0.0006) nm, b=(24.721±0.002) nm, and c=(14.5587±0.0011) nm, α=90°, β=97.850 (4) °, γ=90 °, V=2982.51 nm3, Dc= 1.179 mg/m3, and the molecular number (Z) of elementary structures was 2. The comparisons show that the extraction rate of acankoreanogenin with ECHS methods is much higher than that of traditional methods. Then, central composite design-response surface methodology (CCD-RSM) was adopted for optimizing the extraction rate of ECHS methods. The optimized values of extraction parameters are as follows: for the for extraction process of acid hydrolysis are that extraction time 110.8 min, solvent-herb ratio 11.5 and acid content 5.25%; the best extraction process of basic hydrolysis are that extract time 120 min, solvent-herb ratio 8.7 and the alkali content 8.79%. Finally, the extracts were purified with decolorizing carbon after alkali solution and acid-isolation and purity of acankoreanogenin was 98.7%.
文摘2012 is a year of celebrate centenary of X-ray discovery information about Laue's (Fridrich and Knipping) experiment was This discovery spread quickly in different countries. The history of written in the paper. Also history mention of Laue's experiment in Russia was presented. The system group of X-ray diffraction was created in 1919/1920 in Petrograd (A. Ioffe, State Physical Technical Institute) and Moscow. Themes of research results, scientific newness and scientific rate were presented. The organization, political and other reasons which retarded the active progress of the method in 1930 were described. Initial stage of progress of the method in Russia-USSR was studied by historian of science partly. The reasons of it are: closed of scientific community, political system of country, Cyrillic barrier, etc.. This paper acquaints western scientific community with non-famous Russian materials on theme.