期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
激光聚变靶中氘氚燃料的测量 被引量:7
1
作者 郑永铭 李秀琴 +1 位作者 赵朝康 杨淑娟 《强激光与粒子束》 EI CAS CSCD 1989年第1期69-76,共8页
用Si(Li)-S85低能X-射线谱仪系统测量简单爆推靶中氘氚燃料的含量。用内充气正比计数装置刻度了此谱仪系统的探测效率。其效率与玻璃球成份和壁厚有关。本系统的效率为10~5量级。根据氚含量及燃料的D/T比值,推算出靶内含氘量及氘氚燃料... 用Si(Li)-S85低能X-射线谱仪系统测量简单爆推靶中氘氚燃料的含量。用内充气正比计数装置刻度了此谱仪系统的探测效率。其效率与玻璃球成份和壁厚有关。本系统的效率为10~5量级。根据氚含量及燃料的D/T比值,推算出靶内含氘量及氘氚燃料的总气压,并与气泡法测得的总气压进行了比较。最后对实验结果进行分析和讨论。 展开更多
关键词 激光聚变靶 氘氚燃料 x射线谱仪法
下载PDF
Research on Preparation of the Composite Materials LiFePO4-Li3V2(PO4)3
2
作者 Haoyu JIANG Jianrong Xiao Hang Zhao 《International Journal of Technology Management》 2014年第4期98-100,共3页
The article developed a lithium iron phosphate - composite cathode material of lithium vanadium phosphate. Using X-ray diffraction (XRD), electronic scanning electron microscopy surface (SEM), laser particle size ... The article developed a lithium iron phosphate - composite cathode material of lithium vanadium phosphate. Using X-ray diffraction (XRD), electronic scanning electron microscopy surface (SEM), laser particle size analyzer, carbon and sulfur analyzer, and X-ray photoelectron spectroscopy, etc. for the prepared composites were characterized and found the material is mainly crystalline structure of lithium iron phosphate, and lithium vanadium, wherein a small amount of impurities; finer particle size of the material, the particle size distribution is narrow and uniform, smooth particle surface, wrapping in good carbon composite with other materials prepared in comparison the case has a carbon content of about optimum conductivity. To assemble the material into a cell after the 0.1C, IC, 2C when and 5C, the first discharge capacity were 160,145,127 and 109 mA·h·g^-1, after 50 cycles, the discharge capacity of 162, respectively, 144,126 and 106 mA·h·g^-1, which showed good rate characteristics and cycle characteristics. 展开更多
关键词 Lithium iron phosphate lithium vanadium phosphate GRAPHENE composite materials
下载PDF
A statistical approach to fit Gaussian part of full-energy peaks from Si(PIN) and SDD X-ray spectrometers 被引量:4
3
作者 LI Zhe TUO XianGuo +1 位作者 SHI Rui YANG JianBo 《Science China(Technological Sciences)》 SCIE EI CAS 2014年第1期19-24,共6页
A new statistical fitting approach, named Statistical Distribution-Based Analytic (SDA) method, is proposed to fit single Gaussian-shaped Ka and KI3 X-ray peaks recorded by Si(PIN) and silicon drift detector (SDD... A new statistical fitting approach, named Statistical Distribution-Based Analytic (SDA) method, is proposed to fit single Gaussian-shaped Ka and KI3 X-ray peaks recorded by Si(PIN) and silicon drift detector (SDD). In this method, we use the dis- crete distribution theory to calculate standard deviation of energy resolution a. The calibration of cr and energy (E) for two de- tectors between the energy ranges of 4.5-26 keV are also completed by measuring characteristic X-ray spectra of nineteen types of pure elements. With the spectrum fraction (SF) parameter proposed in this paper, the SDA method can be used to re- solve overlapping peaks. In measured spectra, the Gaussian part of X-ray peaks can be fitted by a Gaussian function with two parameters, ~ and SF. This new fitting approach is simpler than traditional methods and it achieves relatively good results when fitting the complex X-ray spectra of national standard alloy samples detected by Si(PIN) and SDD detectors. The 3(2 values are obtained for each spectrum to assess fitting results, and the SDA fitting method gives a preferable fit for the SDD detector. 展开更多
关键词 Gaussian distribution Si(PIN) SDD EDxRF standard deviation of energy resolution
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部