Metal-halide perovskites are revolutionizing the world of X-ray detectors,due to the development of sensitive,fast,and cost-effective devices.Self-powered operation,ensuring portability and low power consumption,has a...Metal-halide perovskites are revolutionizing the world of X-ray detectors,due to the development of sensitive,fast,and cost-effective devices.Self-powered operation,ensuring portability and low power consumption,has also been recently demonstrated in both bulk materials and thin films.However,the signal stability and repeatability under continuous X-ray exposure has only been tested up to a few hours,often reporting degradation of the detection performance.Here it is shown that self-powered direct X-ray detectors,fabricated starting from a FAPbBr_(3)submicrometer-thick film deposition onto a mesoporous TiO_(2)scaffold,can withstand a 26-day uninterrupted X-ray exposure with negligible signal loss,demonstrating ultra-high operational stability and excellent repeatability.No structural modification is observed after irradiation with a total ionizing dose of almost 200 Gy,revealing an unexpectedly high radiation hardness for a metal-halide perovskite thin film.In addition,trap-assisted photoconductive gain enabled the device to achieve a record bulk sensitivity of 7.28 C Gy^(−1)cm^(−3)at 0 V,an unprecedented value in the field of thin-film-based photoconductors and photodiodes for“hard”X-rays.Finally,prototypal validation under the X-ray beam produced by a medical linear accelerator for cancer treatment is also introduced.展开更多
The solar X-ray detector(SXD)onboard the Macao Science Satellite-1B was designed to monitor solar flare bursts and to study the solar activity in the 25th solar cycle.The SXD includes two parts:a soft X-ray detection ...The solar X-ray detector(SXD)onboard the Macao Science Satellite-1B was designed to monitor solar flare bursts and to study the solar activity in the 25th solar cycle.The SXD includes two parts:a soft X-ray detection unit and a hard X-ray detection unit.Both the soft X-ray detection unit and the hard X-ray detection unit include two collimators,two X-ray detectors(a silicon drift detector and a cadmium-zinc-telluride detector),and a processing circuit.Compared with similar instruments,the energy range of the SXD is wider(1–600 ke V)and the energy resolution is better(150 e V at 5.9 ke V,12%at 59.5 ke V,and 3%at 662 keV).展开更多
X-ray imaging technologies such as digital radiography(DR),is an important aspect of modern non-destructive testing and medical diagnosis.Innovative flexible X-ray detector technologies have recently been proposed and...X-ray imaging technologies such as digital radiography(DR),is an important aspect of modern non-destructive testing and medical diagnosis.Innovative flexible X-ray detector technologies have recently been proposed and are now receiving increasing attention owing to their superior material flexibility compared with traditional flat-panel detectors.This work aims to study these innovative flexible X-ray detectors in terms of their effectiveness in DR imaging,such as detection efficiency and spatial resolution.To achieve this goal,first,a Monte Carlo model was developed and calibrated to an in-lab 150 kV DR imaging system containing a flat-panel X-ray detector.Second,the validated model was updated with various types of flexible X-ray detectors to assess their performance in nearly realistic conditions.Key parameters such as the detection efficiency pertaining to the crystal material and thickness were studied and analyzed across a broader energy range up to 662 keV.Finally,the imaging performance of the different detectors was evaluated and compared to that of the flat-panel detector in the 150 kV DR imaging system.The results show that the flexible detectors such as the CsPbBr3crystal detector deliver promising performance in X-ray imaging and can be applied to a wider range of application scenarios,especially those requiring accurate detection at challenging angles.展开更多
Just as lead-based perovskites that are hot in solar cell preparation, Bi-based perovskites have demonstrated excellent performance in direct X-ray detection, especially the Cs<sub>3</sub>Bi<sub>2<...Just as lead-based perovskites that are hot in solar cell preparation, Bi-based perovskites have demonstrated excellent performance in direct X-ray detection, especially the Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub> single crystals (SCs). However, compared with lead-halide perovskites, one challenge for the Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub> SCs for X-ray detection application is that it is difficult to prepare large-sized and high-quality SCs. Therefore, how to get a large area with a high-quality wafer is also as important as Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub> growth method research. Here, different anti-solvents are used for the preparation of poly-crystalline powder with the Antisolvents precipitation (A) method, as a control, High-energy ball milling (B) was also used to prepare poly-crystalline powders. The resultant two types of Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub> wafer exhibit a micro-strain of 1.21 × 10<sup>-3</sup>, a resistivity of 5.13 × 10<sup>8</sup> Ω cm and a microstrain of 1.21 × 10<sup>-3</sup>, a resistivity of 2.21 × 10<sup>9</sup> Ω cm. As a result, an X-ray detector based on the high-quality Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub> wafer exhibits excellent dose rate linearity, a sensitivity of 588 μC·Gyairs<sup>-1</sup>·cm<sup>-2</sup> and a limit of detection (LoD) of 76 nGyair·s<sup>-1</sup>.展开更多
Diamond is a highly suitable material for X-ray detectors that can function effectively in harsh environments due to its unique properties such as ultrawide bandgap,high radiation resistance,excellent carrier mobility...Diamond is a highly suitable material for X-ray detectors that can function effectively in harsh environments due to its unique properties such as ultrawide bandgap,high radiation resistance,excellent carrier mobility as well as remarkable chemical and thermal stability.However,the sensitivity of diamond X-ray detectors needs further improvement due to the relatively low X-ray absorption efficiency of diamond,and the exploration of singlecrystal diamond array imaging still remains unexplored.In the current work,a 10310 X-ray photodetector array was constructed from single-crystal diamond.To improve the sensitivity of the diamond X-ray detector,an asymmetric sandwich electrode structure was utilized.Additionally,trenches were created through laser cutting to prevent crosstalk between adjacent pixels.The diamond X-ray detector array exhibits exceptional performance,including a low detection limit of 4.9 nGy s^(-1),a sensitivity of 14.3 mC Gy^(-1) cm^(-2),and a light-dark current ratio of 18,312,which are among the most favorable values ever reported for diamond X-ray detectors.Furthermore,these diamond X-ray detectors can operate at high temperatures up to 450℃,making them suitable for development in harsh environments.展开更多
On May 21,2023,the Macao Science Satellite-1B(MSS-1B),a low-inclination,low-latitude,and high-precision scientific exploration satellite for geomagnetic fields and space environments,was successfully launched.The sola...On May 21,2023,the Macao Science Satellite-1B(MSS-1B),a low-inclination,low-latitude,and high-precision scientific exploration satellite for geomagnetic fields and space environments,was successfully launched.The solar X-ray detector(SXD),one of the two major scientific payloads onboard the MSS-1B,has obtained a large amount of solar X-ray radiation data,which reveals the distribution law of the magnetic field in the low Earth orbit,as well as the coupling law of the Earth's magnetic field and the solar radiation and energy particle distributions.First,the overall design of the multi-detection-unit,broad-energy-range,small-volume,and low-power SXD was implemented to achieve the scientific objectives of the mission.Second,the technical indicators of the instrument were decomposed into various components,and the key technologies,such as collimator,processing circuit,thermal,and payload dataset designs,were reviewed.Third,the backgrounds,including electronic noise,cosmic diffuse X-ray background,and high-energy background in the Earth's radiation belts in and out of the field of view,were analyzed for the instrument.Then,the ground calibrations of the energy response,detection efficiency,and temperature-dependent peak drift of the SXD flight model were conducted.Finally,the in-orbit temperature,energy spectrum data,background,and solar flare process observation of the instrument in the in-orbit test stage are presented,verifying the instrument design,analysis,and ground calibration,providing a foundation for obtaining accurate solar X-ray radiation data,and achieving the scientific objectives of the satellite.展开更多
POLAR-2 is a gamma-ray burst(GRB)polarimeter that is designed to study the polarization in GRB radiation emissions,aiming to improve our knowledge of related mechanisms.POLAR-2 is expected to utilize an on-board polar...POLAR-2 is a gamma-ray burst(GRB)polarimeter that is designed to study the polarization in GRB radiation emissions,aiming to improve our knowledge of related mechanisms.POLAR-2 is expected to utilize an on-board polarimeter that is sensitive to soft X-rays(2-10 keV),called low-energy polarization detector.We have developed a new soft X-ray polari-zation detector prototype based on gas microchannel plates(GMCPs)and pixel chips(Topmetal).The GMCPs have bulk resistance,which prevents charging-up effects and ensures gain stability during operation.The detector is composed of low outgassing materials and is gas-sealed using a laser welding technique,ensuring long-term stability.A modulation factor of 41.28%±0.64% is obtained for a 4.5 keV polarized X-ray beam.A residual modulation of 1.96%±0.58% at 5.9 keV is observed for the entire sensitive area.展开更多
In comparison to inorganic counterparts,organic semiconducting(OSC)crystalline films are promising for building large-area and flexible ionizing radiation detectors for X-ray imaging or dosimetry due to their tissue e...In comparison to inorganic counterparts,organic semiconducting(OSC)crystalline films are promising for building large-area and flexible ionizing radiation detectors for X-ray imaging or dosimetry due to their tissue equivalence,simple processing and large-scale production accessibility.Fabrication processes,how-ever,hinder the ability to generate aligned and large-area films with high carrier mobility.In this work,the space-confined melt process is used to produce highly orientated 4HCB(4-hydroxycyanobenzene)OSC films with a large area of 15×18 mm^(2).The out-of-plane direction of the 4HCB film is<001>,and the benzene rings are found to be extensively overlapped inside the in-plane direction,according to the XRD patterns.The film exhibits a high resistivity up to 1012cm,and high hole mobility of 10.62 cm^(2)V^(−1)s^(−1).Furthermore,the 4HCB(80μm-thick film)based X-ray detectors can achieve a sensitivity of 93μC Gy air^(−1) cm^(−2)and on/offratio of 157.The device also shows steady flexibility,with no degradation in detecting function after 100 cycles of bending.Finally,the proposed 4HCB film detectors demonstrated a high-resolution X-ray imaging capability.The imaging of several materials with sharp edges(copper and polytetrafluoroethylene)has been obtained.This work has developed a fast but efficient approach for producing large-area,highly oriented OSC films for high-performance X-ray detectors.展开更多
In recent years,two-dimensional metal halide perovskites(MHPs)have attracted increased attention for radiation detection and imaging.Their detection efficiencies are almost comparable to three-dimensional(3D)perovskit...In recent years,two-dimensional metal halide perovskites(MHPs)have attracted increased attention for radiation detection and imaging.Their detection efficiencies are almost comparable to three-dimensional(3D)perovskites.Meanwhile,they demonstrate superior stability to 3D perovskites.The pursuit of high-quality,phase-pure and lead-free two-dimensional MHP materials and large-area fabrication capability for x-ray detectors are among the research hotspots.In this review,we first give a brief introduction of the crystallographic structure,optoelectronic characteristics and preparation methods of high-quality two-dimensional perovskites.In addition,we overview the general working principles of direct and indirect x-ray detection processes and the corresponding performance metrics from the perspective of detection and imaging.Furthermore,we provide a comprehensive discussion on the recent advances in 2D perovskite x-ray detectors and imaging devices.Finally,we pinpoint several major obstacles of 2D x-ray detectors that should be overcome in the near future.展开更多
Topmetal-M2 is a large-area pixel sensor chip fabricated using the GSMC 130 nm CMOS process in 2021.The pixel array of Topmetal-M2 consists of pixels of 400 rows×512 columns with a pixel pitch of 45μm×45μm...Topmetal-M2 is a large-area pixel sensor chip fabricated using the GSMC 130 nm CMOS process in 2021.The pixel array of Topmetal-M2 consists of pixels of 400 rows×512 columns with a pixel pitch of 45μm×45μm.The array is divided into 16 subarrays,with pixels of 400 rows×32 columns per subarray.Each pixel incorporates two charge sensors:a diode sensor and a Topmetal sensor.The in-pixel circuit primarily consists of a charge-sensitive amplifier for energy measurements,a discriminator with a peak-holding circuit,and a time-to-amplitude converter for time-of-arrival measurements.The pixel of Topmetal-M2 has a charge input range of~0-3 k e-,a voltage output range of~0-180 mV,and a charge-voltage conversion gain of~59.56μV∕e-.The average equivalent noise charge of Topmetal-M2,which includes the readout electronic system noise,is~43.45 e-.In the scanning mode,the time resolution of Topmetal-M2 is 1 LSB=1.25μs,and the precision is^()7.41μs.At an operating voltage of 1.5 V,Topmetal-M2 has a power consumption of~49 mW∕cm~2.In this article,we provide a comprehensive overview of the chip architecture,pixel working principles,and functional behavior of Topmetal-M2.Furthermore,we present the results of preliminary tests conducted on Topmetal-M2,namely,alpha-particle and soft X-ray tests.展开更多
Scintillation semiconductors play increasingly important medical diagnosis and industrial inspection roles.Recently,two-dimensional(2D)perovskites have been shown to be promising materials for medical X-ray imaging,bu...Scintillation semiconductors play increasingly important medical diagnosis and industrial inspection roles.Recently,two-dimensional(2D)perovskites have been shown to be promising materials for medical X-ray imaging,but they are mostly used in low-energy(≤130 keV)regions.Direct detection of MeV X-rays,which ensure thorough penetration of the thick shell walls of containers,trucks,and aircraft,is also highly desired in practical industrial applications.Unfortunately,scintillation semiconductors for high-energy X-ray detection are currently scarce.Here,This paper reports a 2D(C_(4)H_(9)NH_(3))_(2)PbBr_(4)single crystal with outstanding sensitivity and stability toward X-ray radiation that provides an ultra-wide detectable X-ray range of between 8.20 nGy_(air)s^(-1)(50 keV)and 15.24 mGy_(air)s^(-1)(9 MeV).The(C_(4)H_(9)NH_(3))_(2)PbBr_(4)single-crystal detector with a vertical structure is used for high-performance X-ray imaging,delivering a good spatial resolution of 4.3 Ip mm^(-1)in a plane-scan imaging system.Low ionic migration in the 2D perovskite enables the vertical device to be operated with hundreds of keV to MeV X-ray radiation at high bias voltages,leading to a sensitivity of 46.90μC Gy_(air)-1 cm^(-2)(-1.16 Vμm^(-1))with 9 MeV X-ray radiation,demonstrating that 2D perovskites have enormous potential for high-energy industrial applications.展开更多
This study presents an electronics system for cosmic X-ray polarization detection(CXPD).The CXPD was designed as a high-sensitivity soft X-ray polarimeter with a measurement energy range of 2-10 keV carried by a CubeS...This study presents an electronics system for cosmic X-ray polarization detection(CXPD).The CXPD was designed as a high-sensitivity soft X-ray polarimeter with a measurement energy range of 2-10 keV carried by a CubeSat.A stable and functionally complete electronics system under power and space constraints is a key challenge.The complete CXPD electronics system(CXPDES)comprises hardware and firmware.CXPDES adopts a three-layer electronic board structure based on functionality and available space.Two gas pixel detectors(GPDs)were placed on the top layer board,and CXPDES provided the GPDs with voltages up to-4000 V.Each GPD signal was digitized,compressed,encoded,and stored before being transmitted to the ground.The CXPDES provided stable and high-speed communication based on a scheme that separated command and data transmission,and it supports the CXPDES in-orbit upgrade.In addition,environmental monitors,silicon photomultiplier(SiPM)triggers,power management,GPDs configuration,and mode switches were included in the overall operating logic of the CXPDES.The results obtained by testing the CXPDES showed that it satisfied all the requirements of CXPD.The CXPDES provides design experience and technological readiness for future large-area X-ray polarimetry missions.展开更多
Earth’s magnetopause is a thin boundary separating the shocked solar wind plasma from the magnetospheric plasmas,and it is also the boundary of the solar wind energy transport to the magnetosphere.Soft X-ray imaging ...Earth’s magnetopause is a thin boundary separating the shocked solar wind plasma from the magnetospheric plasmas,and it is also the boundary of the solar wind energy transport to the magnetosphere.Soft X-ray imaging allows investigation of the large-scale magnetopause by providing a two-dimensional(2-D)global view from a satellite.By performing 3-D global hybrid-particle-in-cell(hybrid-PIC)simulations,we obtain soft X-ray images of Earth’s magnetopause under different solar wind conditions,such as different plasma densities and directions of the southward interplanetary magnetic field.In all cases,magnetic reconnection occurs at low latitude magnetopause.The soft X-ray images observed by a hypothetical satellite are shown,with all of the following identified:the boundary of the magnetopause,the cusps,and the magnetosheath.Local X-ray emissivity in the magnetosheath is characterized by large amplitude fluctuations(up to 160%);however,the maximum line-of-sight-integrated X-ray intensity matches the tangent directions of the magnetopause well,indicating that these fluctuations have limited impact on identifying the magnetopause boundary in the X-ray images.Moreover,the magnetopause boundary can be identified using multiple viewing geometries.We also find that solar wind conditions have little effect on the magnetopause identification.The Solar wind Magnetosphere Ionosphere Link Explorer(SMILE)mission will provide X-ray images of the magnetopause for the first time,and our global hybrid-PIC simulation results can help better understand the 2-D X-ray images of the magnetopause from a 3-D perspective,with particle kinetic effects considered.展开更多
The Soft X-ray Imager(SXI)is part of the scientific payload of the Solar wind Magnetosphere Ionosphere Link Explorer(SMILE)mission.SMILE is a joint science mission between the European Space Agency(ESA)and the Chinese...The Soft X-ray Imager(SXI)is part of the scientific payload of the Solar wind Magnetosphere Ionosphere Link Explorer(SMILE)mission.SMILE is a joint science mission between the European Space Agency(ESA)and the Chinese Academy of Sciences(CAS)and is due for launch in 2025.SXI is a compact X-ray telescope with a wide field-of-view(FOV)capable of encompassing large portions of Earth’s magnetosphere from the vantage point of the SMILE orbit.SXI is sensitive to the soft X-rays produced by the Solar Wind Charge eXchange(SWCX)process produced when heavy ions of solar wind origin interact with neutral particles in Earth’s exosphere.SWCX provides a mechanism for boundary detection within the magnetosphere,such as the position of Earth’s magnetopause,because the solar wind heavy ions have a very low density in regions of closed magnetic field lines.The sensitivity of the SXI is such that it can potentially track movements of the magnetopause on timescales of a few minutes and the orbit of SMILE will enable such movements to be tracked for segments lasting many hours.SXI is led by the University of Leicester in the United Kingdom(UK)with collaborating organisations on hardware,software and science support within the UK,Europe,China and the United States.展开更多
Solar wind charge exchange(SWCX)is the process of solar wind high-valence ions exchanging charges with neutral components and generating soft X-rays.Recently,detecting the SWCX emission from the magnetosphere is propo...Solar wind charge exchange(SWCX)is the process of solar wind high-valence ions exchanging charges with neutral components and generating soft X-rays.Recently,detecting the SWCX emission from the magnetosphere is proposed as a new technique to study the magnetosphere using panoramic soft X-ray imaging.To better prepare for the data analysis of upcoming magnetospheric soft X-ray imaging missions,this paper compares the magnetospheric SWCX emission obtained by two methods in an XMM-Newton observation,during which the solar wind changed dramatically.The two methods differ in the data used to fit the diffuse X-ray background(DXB)parameters in spectral analysis.The method adding data from the ROSAT All-Sky Survey(RASS)is called the RASS method.The method using the quiet observation data is called the Quiet method,where quiet observations usually refer to observations made by the same satellite with the same target but under weaker solar wind conditions.Results show that the spectral compositions of magnetospheric SWCX emission obtained by the two methods are very similar,and the changes in intensity over time are highly consistent,although the intensity obtained by the RASS method is about 2.68±0.56 keV cm^(-2)s^(-1)sr^(-1)higher than that obtained by the Quiet method.Since the DXB intensity obtained by the RASS method is about 2.84±0.74 keV cm^(-2)s^(-1)sr^(-1)lower than that obtained by the Quiet method,and the linear correlation coefficient between the difference of SWCX and DXB obtained by the two methods in diffe rent energy band is close to-1,the diffe rences in magnetospheric SWCX can be fully attributed to the diffe rences in the fitted DXB.The difference between the two methods is most significant when the energy is less than 0.7 keV,which is also the main energy band of SWCX emission.In addition,the difference between the two methods is not related to the SWCX intensity and,to some extent,to solar wind conditions,because SWCX intensity typically va ries with the solar wind.In summary,both methods are robust and reliable,and should be considered based on the best available options.展开更多
Variability in the location and shape of the dayside magnetopause is attributed to magnetic reconnection,a fundamental process that enables the transfer of mass,energy,and momentum from the solar wind into the magneto...Variability in the location and shape of the dayside magnetopause is attributed to magnetic reconnection,a fundamental process that enables the transfer of mass,energy,and momentum from the solar wind into the magnetosphere.The spatial and temporal properties of the magnetopause,under varying solar and magnetospheric conditions,remain largely unknown because empirical studies using in-situ observations are challenging to interpret.Global wide field-of-view(FOV)imaging is the only means to simultaneously observe the spatial distribution of the plasma properties over the vast dayside magnetospheric region and,subsequently,quantify the energy transport from the interplanetary medium into the terrestrial magnetosphere.Two upcoming missions,ESA/CAS SMILE and NASA’s LEXI will provide wide-field imagery of the dayside magnetosheath in soft X-rays,an emission generated by charge exchange interactions between high charge-state heavy ions of solar wind origin and exospheric neutral atoms.High-cadence two-dimensional observations of the magnetosheath will allow the estimation of dynamic properties of its inner boundary,the magnetopause,and enable studies of its response to changes in the solar wind dynamic pressure and interplanetary magnetic field orientation.This work introduces a statistically-based estimation approach based on inverse theory to estimate the spatial distribution of magnetosheath soft X-ray emissivities and,with this,identify the location of the magnetopause over the Sun−Earth line.To do so,we simulate the magnetosheath structure using the MHD-based OpenGGCM model and generate synthetic soft X-ray images using LEXI’s orbit and attitude information.Our results show that 3-D estimations using the described statistically-based technique are robust against Poisson-distributed shot noise inherent to soft X-ray images.Also,our proposed methodology shows that the accuracy of both three-dimensional(3-D)estimation and the magnetopause standoff distance calculation highly depends on the observational point.展开更多
The Lunar Environment heliospheric X-ray Imager(LEXI)and Solar wind Magnetosphere Ionosphere Link Explorer(SMILE)missions will image the Earth’s dayside magneto pause and cusps in soft X-rays after their respective l...The Lunar Environment heliospheric X-ray Imager(LEXI)and Solar wind Magnetosphere Ionosphere Link Explorer(SMILE)missions will image the Earth’s dayside magneto pause and cusps in soft X-rays after their respective launches in the near future,to specify glo bal magnetic reconnection modes for varying solar wind conditions.To suppo rt the success of these scientific missions,it is critical to develop techniques that extract the magnetopause locations from the observed soft X-ray images.In this research,we introduce a new geometric equation that calculates the subsolar magnetopause position(RS)from a satellite position,the look direction of the instrument,and the angle at which the X-ray emission is maximized.Two assumptions are used in this method:(1)The look direction where soft X-ray emissions are maximized lies tangent to the magnetopause,and(2)the magnetopause surface near the subsolar point is almost spherical and thus RSis nea rly equal to the radius of the magneto pause curvature.We create synthetic soft X-ray images by using the Open Geospace General Circulation Model(OpenGGCM)global magnetohydrodynamic model,the galactic background,the instrument point spread function,and Poisson noise.We then apply the fast Fourier transform and Gaussian low-pass filte rs to the synthetic images to re move noise and obtain accurate look angles for the soft X-ray pea ks.From the filte red images,we calculate RS and its accuracy for different LEXI locations,look directions,and solar wind densities by using the OpenGGCM subsolar magnetopause location as ground truth.Our method estimates RS with an accuracy of<0.3 RE when the solar wind density exceeds>10 cm-3.The accuracy improves for greater solar wind densities and during southward interplanetary magnetic fields.The method ca ptures the magnetopause motion during southwa rd interplaneta ry magnetic field turnings.Consequently,the technique will enable quantitative analysis of the magnetopause motion and help reveal the dayside reconnection modes for dynamic solar wind conditions.This technique will suppo rt the LEXI and SMILE missions in achieving their scientific o bjectives.展开更多
Throughout the SMILE mission the satellite will be bombarded by radiation which gradually damages the focal plane devices and degrades their performance.In order to understand the changes of the CCD370s within the sof...Throughout the SMILE mission the satellite will be bombarded by radiation which gradually damages the focal plane devices and degrades their performance.In order to understand the changes of the CCD370s within the soft X-ray Imager,an initial characterisation of the devices has been carried out to give a baseline performance level.Three CCDs have been characterised,the two flight devices and the flight spa re.This has been carried out at the Open University in a bespo ke cleanroom measure ment facility.The results show that there is a cluster of bright pixels in the flight spa re which increases in size with tempe rature.However at the nominal ope rating tempe rature(-120℃) it is within the procure ment specifications.Overall,the devices meet the specifications when ope rating at -120℃ in 6 × 6 binned frame transfer science mode.The se rial charge transfer inefficiency degrades with temperature in full frame mode.However any charge losses are recovered when binning/frame transfer is implemented.展开更多
基金supported by the project“PARIDE”(Perovskite Advanced Radiotherapy&Imaging Detectors),funded under the Regional Research and Innovation Programme POR-FESR Lazio 2014-2020(project number:A0375-2020-36698).
文摘Metal-halide perovskites are revolutionizing the world of X-ray detectors,due to the development of sensitive,fast,and cost-effective devices.Self-powered operation,ensuring portability and low power consumption,has also been recently demonstrated in both bulk materials and thin films.However,the signal stability and repeatability under continuous X-ray exposure has only been tested up to a few hours,often reporting degradation of the detection performance.Here it is shown that self-powered direct X-ray detectors,fabricated starting from a FAPbBr_(3)submicrometer-thick film deposition onto a mesoporous TiO_(2)scaffold,can withstand a 26-day uninterrupted X-ray exposure with negligible signal loss,demonstrating ultra-high operational stability and excellent repeatability.No structural modification is observed after irradiation with a total ionizing dose of almost 200 Gy,revealing an unexpectedly high radiation hardness for a metal-halide perovskite thin film.In addition,trap-assisted photoconductive gain enabled the device to achieve a record bulk sensitivity of 7.28 C Gy^(−1)cm^(−3)at 0 V,an unprecedented value in the field of thin-film-based photoconductors and photodiodes for“hard”X-rays.Finally,prototypal validation under the X-ray beam produced by a medical linear accelerator for cancer treatment is also introduced.
基金the China National Space Administration(CNSA)the Macao University of Science and Technology Foundation for their support of this paper。
文摘The solar X-ray detector(SXD)onboard the Macao Science Satellite-1B was designed to monitor solar flare bursts and to study the solar activity in the 25th solar cycle.The SXD includes two parts:a soft X-ray detection unit and a hard X-ray detection unit.Both the soft X-ray detection unit and the hard X-ray detection unit include two collimators,two X-ray detectors(a silicon drift detector and a cadmium-zinc-telluride detector),and a processing circuit.Compared with similar instruments,the energy range of the SXD is wider(1–600 ke V)and the energy resolution is better(150 e V at 5.9 ke V,12%at 59.5 ke V,and 3%at 662 keV).
基金supported by the China Natural Science Fund (No.52171253)Natural Science Foundation of Sichuan (No.2022NSFSC0949)。
文摘X-ray imaging technologies such as digital radiography(DR),is an important aspect of modern non-destructive testing and medical diagnosis.Innovative flexible X-ray detector technologies have recently been proposed and are now receiving increasing attention owing to their superior material flexibility compared with traditional flat-panel detectors.This work aims to study these innovative flexible X-ray detectors in terms of their effectiveness in DR imaging,such as detection efficiency and spatial resolution.To achieve this goal,first,a Monte Carlo model was developed and calibrated to an in-lab 150 kV DR imaging system containing a flat-panel X-ray detector.Second,the validated model was updated with various types of flexible X-ray detectors to assess their performance in nearly realistic conditions.Key parameters such as the detection efficiency pertaining to the crystal material and thickness were studied and analyzed across a broader energy range up to 662 keV.Finally,the imaging performance of the different detectors was evaluated and compared to that of the flat-panel detector in the 150 kV DR imaging system.The results show that the flexible detectors such as the CsPbBr3crystal detector deliver promising performance in X-ray imaging and can be applied to a wider range of application scenarios,especially those requiring accurate detection at challenging angles.
文摘Just as lead-based perovskites that are hot in solar cell preparation, Bi-based perovskites have demonstrated excellent performance in direct X-ray detection, especially the Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub> single crystals (SCs). However, compared with lead-halide perovskites, one challenge for the Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub> SCs for X-ray detection application is that it is difficult to prepare large-sized and high-quality SCs. Therefore, how to get a large area with a high-quality wafer is also as important as Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub> growth method research. Here, different anti-solvents are used for the preparation of poly-crystalline powder with the Antisolvents precipitation (A) method, as a control, High-energy ball milling (B) was also used to prepare poly-crystalline powders. The resultant two types of Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub> wafer exhibit a micro-strain of 1.21 × 10<sup>-3</sup>, a resistivity of 5.13 × 10<sup>8</sup> Ω cm and a microstrain of 1.21 × 10<sup>-3</sup>, a resistivity of 2.21 × 10<sup>9</sup> Ω cm. As a result, an X-ray detector based on the high-quality Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub> wafer exhibits excellent dose rate linearity, a sensitivity of 588 μC·Gyairs<sup>-1</sup>·cm<sup>-2</sup> and a limit of detection (LoD) of 76 nGyair·s<sup>-1</sup>.
基金financially supported by the National Key R&D Program of China(2022YFB3608604)Science and Technology Major Project of Henan Province(231100230300)+3 种基金Science and Technology on Plasma Physics Laboratory(JCKYS2021212010)National Natural Science Foundation of China(U21A2070,12274373)Key Research and Development Project of Henan Province(231111232100)Natural Science Foundation of Henan Province(242300421155).
文摘Diamond is a highly suitable material for X-ray detectors that can function effectively in harsh environments due to its unique properties such as ultrawide bandgap,high radiation resistance,excellent carrier mobility as well as remarkable chemical and thermal stability.However,the sensitivity of diamond X-ray detectors needs further improvement due to the relatively low X-ray absorption efficiency of diamond,and the exploration of singlecrystal diamond array imaging still remains unexplored.In the current work,a 10310 X-ray photodetector array was constructed from single-crystal diamond.To improve the sensitivity of the diamond X-ray detector,an asymmetric sandwich electrode structure was utilized.Additionally,trenches were created through laser cutting to prevent crosstalk between adjacent pixels.The diamond X-ray detector array exhibits exceptional performance,including a low detection limit of 4.9 nGy s^(-1),a sensitivity of 14.3 mC Gy^(-1) cm^(-2),and a light-dark current ratio of 18,312,which are among the most favorable values ever reported for diamond X-ray detectors.Furthermore,these diamond X-ray detectors can operate at high temperatures up to 450℃,making them suitable for development in harsh environments.
基金supported by the National Natural Science Foundation of China(Grant No.42327802)the National Key R&D Program of China(Grant No.2022YFF0708100)。
文摘On May 21,2023,the Macao Science Satellite-1B(MSS-1B),a low-inclination,low-latitude,and high-precision scientific exploration satellite for geomagnetic fields and space environments,was successfully launched.The solar X-ray detector(SXD),one of the two major scientific payloads onboard the MSS-1B,has obtained a large amount of solar X-ray radiation data,which reveals the distribution law of the magnetic field in the low Earth orbit,as well as the coupling law of the Earth's magnetic field and the solar radiation and energy particle distributions.First,the overall design of the multi-detection-unit,broad-energy-range,small-volume,and low-power SXD was implemented to achieve the scientific objectives of the mission.Second,the technical indicators of the instrument were decomposed into various components,and the key technologies,such as collimator,processing circuit,thermal,and payload dataset designs,were reviewed.Third,the backgrounds,including electronic noise,cosmic diffuse X-ray background,and high-energy background in the Earth's radiation belts in and out of the field of view,were analyzed for the instrument.Then,the ground calibrations of the energy response,detection efficiency,and temperature-dependent peak drift of the SXD flight model were conducted.Finally,the in-orbit temperature,energy spectrum data,background,and solar flare process observation of the instrument in the in-orbit test stage are presented,verifying the instrument design,analysis,and ground calibration,providing a foundation for obtaining accurate solar X-ray radiation data,and achieving the scientific objectives of the satellite.
基金supported by Department of Physics and GXUNAOC Center for Astrophysics and Space Sciences,Guangxi UniversityThe National Natural Science Foundation of China(Nos.12027803,U1731239,12133003,12175241,U1938201,U1732266)the Guangxi Science Foundation(Nos.2018GXNSFGA281007,2018JJA110048).
文摘POLAR-2 is a gamma-ray burst(GRB)polarimeter that is designed to study the polarization in GRB radiation emissions,aiming to improve our knowledge of related mechanisms.POLAR-2 is expected to utilize an on-board polarimeter that is sensitive to soft X-rays(2-10 keV),called low-energy polarization detector.We have developed a new soft X-ray polari-zation detector prototype based on gas microchannel plates(GMCPs)and pixel chips(Topmetal).The GMCPs have bulk resistance,which prevents charging-up effects and ensures gain stability during operation.The detector is composed of low outgassing materials and is gas-sealed using a laser welding technique,ensuring long-term stability.A modulation factor of 41.28%±0.64% is obtained for a 4.5 keV polarized X-ray beam.A residual modulation of 1.96%±0.58% at 5.9 keV is observed for the entire sensitive area.
基金This work was supported by the National Natural Science Foundations of China(Nos.U2032170,51872228,62104194 and 51802262)The project was also supported by the Fundamental Research Funds for the Central University(3102020QD0408 and D5000210906)+1 种基金the Natural Science Foundation of Shaanxi Province(2020JC-12)the Research Fund of the State Key Laboratory of Solidification Processing(NPU),China(No.2022-TS-07).
文摘In comparison to inorganic counterparts,organic semiconducting(OSC)crystalline films are promising for building large-area and flexible ionizing radiation detectors for X-ray imaging or dosimetry due to their tissue equivalence,simple processing and large-scale production accessibility.Fabrication processes,how-ever,hinder the ability to generate aligned and large-area films with high carrier mobility.In this work,the space-confined melt process is used to produce highly orientated 4HCB(4-hydroxycyanobenzene)OSC films with a large area of 15×18 mm^(2).The out-of-plane direction of the 4HCB film is<001>,and the benzene rings are found to be extensively overlapped inside the in-plane direction,according to the XRD patterns.The film exhibits a high resistivity up to 1012cm,and high hole mobility of 10.62 cm^(2)V^(−1)s^(−1).Furthermore,the 4HCB(80μm-thick film)based X-ray detectors can achieve a sensitivity of 93μC Gy air^(−1) cm^(−2)and on/offratio of 157.The device also shows steady flexibility,with no degradation in detecting function after 100 cycles of bending.Finally,the proposed 4HCB film detectors demonstrated a high-resolution X-ray imaging capability.The imaging of several materials with sharp edges(copper and polytetrafluoroethylene)has been obtained.This work has developed a fast but efficient approach for producing large-area,highly oriented OSC films for high-performance X-ray detectors.
基金supported by the National Natural Science Foundation of China(22279083)Natural Science Foundation of Guangdong Province(2019A1515010783)+1 种基金Guangzhou Science and Technology Planning Project(202102010443)Songshan Lake Materials Laboratory.
文摘In recent years,two-dimensional metal halide perovskites(MHPs)have attracted increased attention for radiation detection and imaging.Their detection efficiencies are almost comparable to three-dimensional(3D)perovskites.Meanwhile,they demonstrate superior stability to 3D perovskites.The pursuit of high-quality,phase-pure and lead-free two-dimensional MHP materials and large-area fabrication capability for x-ray detectors are among the research hotspots.In this review,we first give a brief introduction of the crystallographic structure,optoelectronic characteristics and preparation methods of high-quality two-dimensional perovskites.In addition,we overview the general working principles of direct and indirect x-ray detection processes and the corresponding performance metrics from the perspective of detection and imaging.Furthermore,we provide a comprehensive discussion on the recent advances in 2D perovskite x-ray detectors and imaging devices.Finally,we pinpoint several major obstacles of 2D x-ray detectors that should be overcome in the near future.
基金supported by the National Key Research and Development Program of China(No.2020YFE0202002)the National Natural Science Foundation of China(Nos.11875146 and U1932143)。
文摘Topmetal-M2 is a large-area pixel sensor chip fabricated using the GSMC 130 nm CMOS process in 2021.The pixel array of Topmetal-M2 consists of pixels of 400 rows×512 columns with a pixel pitch of 45μm×45μm.The array is divided into 16 subarrays,with pixels of 400 rows×32 columns per subarray.Each pixel incorporates two charge sensors:a diode sensor and a Topmetal sensor.The in-pixel circuit primarily consists of a charge-sensitive amplifier for energy measurements,a discriminator with a peak-holding circuit,and a time-to-amplitude converter for time-of-arrival measurements.The pixel of Topmetal-M2 has a charge input range of~0-3 k e-,a voltage output range of~0-180 mV,and a charge-voltage conversion gain of~59.56μV∕e-.The average equivalent noise charge of Topmetal-M2,which includes the readout electronic system noise,is~43.45 e-.In the scanning mode,the time resolution of Topmetal-M2 is 1 LSB=1.25μs,and the precision is^()7.41μs.At an operating voltage of 1.5 V,Topmetal-M2 has a power consumption of~49 mW∕cm~2.In this article,we provide a comprehensive overview of the chip architecture,pixel working principles,and functional behavior of Topmetal-M2.Furthermore,we present the results of preliminary tests conducted on Topmetal-M2,namely,alpha-particle and soft X-ray tests.
基金financial support from the National Natural Science Foundation of China(Nos.22075284,51872287,and U2030118)the Youth Innovation Promotion Association CAS(No.2019304)+1 种基金the Fund of Mindu Innovation Laboratory(No.2021ZR201)the Scientific Instrument Developing Project of the Chinese Academy of Sciences(No.YJKYYQ20210039)
文摘Scintillation semiconductors play increasingly important medical diagnosis and industrial inspection roles.Recently,two-dimensional(2D)perovskites have been shown to be promising materials for medical X-ray imaging,but they are mostly used in low-energy(≤130 keV)regions.Direct detection of MeV X-rays,which ensure thorough penetration of the thick shell walls of containers,trucks,and aircraft,is also highly desired in practical industrial applications.Unfortunately,scintillation semiconductors for high-energy X-ray detection are currently scarce.Here,This paper reports a 2D(C_(4)H_(9)NH_(3))_(2)PbBr_(4)single crystal with outstanding sensitivity and stability toward X-ray radiation that provides an ultra-wide detectable X-ray range of between 8.20 nGy_(air)s^(-1)(50 keV)and 15.24 mGy_(air)s^(-1)(9 MeV).The(C_(4)H_(9)NH_(3))_(2)PbBr_(4)single-crystal detector with a vertical structure is used for high-performance X-ray imaging,delivering a good spatial resolution of 4.3 Ip mm^(-1)in a plane-scan imaging system.Low ionic migration in the 2D perovskite enables the vertical device to be operated with hundreds of keV to MeV X-ray radiation at high bias voltages,leading to a sensitivity of 46.90μC Gy_(air)-1 cm^(-2)(-1.16 Vμm^(-1))with 9 MeV X-ray radiation,demonstrating that 2D perovskites have enormous potential for high-energy industrial applications.
基金supported by the National Natural Science Foundation of China (Nos.11875146,U1932143)National Key Research and Development Program of China (No.2020YFE0202002)。
文摘This study presents an electronics system for cosmic X-ray polarization detection(CXPD).The CXPD was designed as a high-sensitivity soft X-ray polarimeter with a measurement energy range of 2-10 keV carried by a CubeSat.A stable and functionally complete electronics system under power and space constraints is a key challenge.The complete CXPD electronics system(CXPDES)comprises hardware and firmware.CXPDES adopts a three-layer electronic board structure based on functionality and available space.Two gas pixel detectors(GPDs)were placed on the top layer board,and CXPDES provided the GPDs with voltages up to-4000 V.Each GPD signal was digitized,compressed,encoded,and stored before being transmitted to the ground.The CXPDES provided stable and high-speed communication based on a scheme that separated command and data transmission,and it supports the CXPDES in-orbit upgrade.In addition,environmental monitors,silicon photomultiplier(SiPM)triggers,power management,GPDs configuration,and mode switches were included in the overall operating logic of the CXPDES.The results obtained by testing the CXPDES showed that it satisfied all the requirements of CXPD.The CXPDES provides design experience and technological readiness for future large-area X-ray polarimetry missions.
基金supported by the National Natural Science Foundation of China(NNSFC)grants 42074202,42274196Strategic Priority Research Program of Chinese Academy of Sciences grant XDB41000000ISSI-BJ International Team Interaction between magnetic reconnection and turbulence:From the Sun to the Earth。
文摘Earth’s magnetopause is a thin boundary separating the shocked solar wind plasma from the magnetospheric plasmas,and it is also the boundary of the solar wind energy transport to the magnetosphere.Soft X-ray imaging allows investigation of the large-scale magnetopause by providing a two-dimensional(2-D)global view from a satellite.By performing 3-D global hybrid-particle-in-cell(hybrid-PIC)simulations,we obtain soft X-ray images of Earth’s magnetopause under different solar wind conditions,such as different plasma densities and directions of the southward interplanetary magnetic field.In all cases,magnetic reconnection occurs at low latitude magnetopause.The soft X-ray images observed by a hypothetical satellite are shown,with all of the following identified:the boundary of the magnetopause,the cusps,and the magnetosheath.Local X-ray emissivity in the magnetosheath is characterized by large amplitude fluctuations(up to 160%);however,the maximum line-of-sight-integrated X-ray intensity matches the tangent directions of the magnetopause well,indicating that these fluctuations have limited impact on identifying the magnetopause boundary in the X-ray images.Moreover,the magnetopause boundary can be identified using multiple viewing geometries.We also find that solar wind conditions have little effect on the magnetopause identification.The Solar wind Magnetosphere Ionosphere Link Explorer(SMILE)mission will provide X-ray images of the magnetopause for the first time,and our global hybrid-PIC simulation results can help better understand the 2-D X-ray images of the magnetopause from a 3-D perspective,with particle kinetic effects considered.
基金funding and support from the United Kingdom Space Agency(UKSA)the European Space Agency(ESA)+5 种基金funded and supported through the ESA PRODEX schemefunded through PRODEX PEA 4000123238the Research Council of Norway grant 223252funded by Spanish MCIN/AEI/10.13039/501100011033 grant PID2019-107061GB-C61funding and support from the Chinese Academy of Sciences(CAS)funding and support from the National Aeronautics and Space Administration(NASA)。
文摘The Soft X-ray Imager(SXI)is part of the scientific payload of the Solar wind Magnetosphere Ionosphere Link Explorer(SMILE)mission.SMILE is a joint science mission between the European Space Agency(ESA)and the Chinese Academy of Sciences(CAS)and is due for launch in 2025.SXI is a compact X-ray telescope with a wide field-of-view(FOV)capable of encompassing large portions of Earth’s magnetosphere from the vantage point of the SMILE orbit.SXI is sensitive to the soft X-rays produced by the Solar Wind Charge eXchange(SWCX)process produced when heavy ions of solar wind origin interact with neutral particles in Earth’s exosphere.SWCX provides a mechanism for boundary detection within the magnetosphere,such as the position of Earth’s magnetopause,because the solar wind heavy ions have a very low density in regions of closed magnetic field lines.The sensitivity of the SXI is such that it can potentially track movements of the magnetopause on timescales of a few minutes and the orbit of SMILE will enable such movements to be tracked for segments lasting many hours.SXI is led by the University of Leicester in the United Kingdom(UK)with collaborating organisations on hardware,software and science support within the UK,Europe,China and the United States.
基金supported by NNSFC grants 42322408,42188101 and 42074202the Strategic Pioneer Program on Space Science,CAS Grant nos.XDA15350201+3 种基金in part by the Research Fund from the Chinese Academy of Sciencesthe Specialized Research Fund for State Key Laboratories of China.supported by the Young Elite Scientists Sponsorship Program(CAST-Y202045)supported by Royal Society grant DHFR1211068。
文摘Solar wind charge exchange(SWCX)is the process of solar wind high-valence ions exchanging charges with neutral components and generating soft X-rays.Recently,detecting the SWCX emission from the magnetosphere is proposed as a new technique to study the magnetosphere using panoramic soft X-ray imaging.To better prepare for the data analysis of upcoming magnetospheric soft X-ray imaging missions,this paper compares the magnetospheric SWCX emission obtained by two methods in an XMM-Newton observation,during which the solar wind changed dramatically.The two methods differ in the data used to fit the diffuse X-ray background(DXB)parameters in spectral analysis.The method adding data from the ROSAT All-Sky Survey(RASS)is called the RASS method.The method using the quiet observation data is called the Quiet method,where quiet observations usually refer to observations made by the same satellite with the same target but under weaker solar wind conditions.Results show that the spectral compositions of magnetospheric SWCX emission obtained by the two methods are very similar,and the changes in intensity over time are highly consistent,although the intensity obtained by the RASS method is about 2.68±0.56 keV cm^(-2)s^(-1)sr^(-1)higher than that obtained by the Quiet method.Since the DXB intensity obtained by the RASS method is about 2.84±0.74 keV cm^(-2)s^(-1)sr^(-1)lower than that obtained by the Quiet method,and the linear correlation coefficient between the difference of SWCX and DXB obtained by the two methods in diffe rent energy band is close to-1,the diffe rences in magnetospheric SWCX can be fully attributed to the diffe rences in the fitted DXB.The difference between the two methods is most significant when the energy is less than 0.7 keV,which is also the main energy band of SWCX emission.In addition,the difference between the two methods is not related to the SWCX intensity and,to some extent,to solar wind conditions,because SWCX intensity typically va ries with the solar wind.In summary,both methods are robust and reliable,and should be considered based on the best available options.
基金supported by NASA Goddard Space Flight Center through Cooperative Agreement 80NSSC21M0180 to Catholic UniversityPartnership for Heliophysics and Space Environment Research(PHaSER)+2 种基金the NASA Heliophysics United States Participating Investigator Program under Grant WBS516741.01.24.01.03(DS)support from the NASA grants 80NSSC19K0844,80NSSC20K1670,and 80MSFC20C0019the NASA GSFC internal fundings(HIF,ISFM,and IRAD)。
文摘Variability in the location and shape of the dayside magnetopause is attributed to magnetic reconnection,a fundamental process that enables the transfer of mass,energy,and momentum from the solar wind into the magnetosphere.The spatial and temporal properties of the magnetopause,under varying solar and magnetospheric conditions,remain largely unknown because empirical studies using in-situ observations are challenging to interpret.Global wide field-of-view(FOV)imaging is the only means to simultaneously observe the spatial distribution of the plasma properties over the vast dayside magnetospheric region and,subsequently,quantify the energy transport from the interplanetary medium into the terrestrial magnetosphere.Two upcoming missions,ESA/CAS SMILE and NASA’s LEXI will provide wide-field imagery of the dayside magnetosheath in soft X-rays,an emission generated by charge exchange interactions between high charge-state heavy ions of solar wind origin and exospheric neutral atoms.High-cadence two-dimensional observations of the magnetosheath will allow the estimation of dynamic properties of its inner boundary,the magnetopause,and enable studies of its response to changes in the solar wind dynamic pressure and interplanetary magnetic field orientation.This work introduces a statistically-based estimation approach based on inverse theory to estimate the spatial distribution of magnetosheath soft X-ray emissivities and,with this,identify the location of the magnetopause over the Sun−Earth line.To do so,we simulate the magnetosheath structure using the MHD-based OpenGGCM model and generate synthetic soft X-ray images using LEXI’s orbit and attitude information.Our results show that 3-D estimations using the described statistically-based technique are robust against Poisson-distributed shot noise inherent to soft X-ray images.Also,our proposed methodology shows that the accuracy of both three-dimensional(3-D)estimation and the magnetopause standoff distance calculation highly depends on the observational point.
基金supported by NASA(Grant Nos.80NSSC19K0844,80NSSC20K1670,80MSFC20C0019,and 80GSFC21M0002)support from NASA Goddard Space Flight Center internal funding programs(HIF,Internal Scientist Funding Model,and Internal Research and Development)。
文摘The Lunar Environment heliospheric X-ray Imager(LEXI)and Solar wind Magnetosphere Ionosphere Link Explorer(SMILE)missions will image the Earth’s dayside magneto pause and cusps in soft X-rays after their respective launches in the near future,to specify glo bal magnetic reconnection modes for varying solar wind conditions.To suppo rt the success of these scientific missions,it is critical to develop techniques that extract the magnetopause locations from the observed soft X-ray images.In this research,we introduce a new geometric equation that calculates the subsolar magnetopause position(RS)from a satellite position,the look direction of the instrument,and the angle at which the X-ray emission is maximized.Two assumptions are used in this method:(1)The look direction where soft X-ray emissions are maximized lies tangent to the magnetopause,and(2)the magnetopause surface near the subsolar point is almost spherical and thus RSis nea rly equal to the radius of the magneto pause curvature.We create synthetic soft X-ray images by using the Open Geospace General Circulation Model(OpenGGCM)global magnetohydrodynamic model,the galactic background,the instrument point spread function,and Poisson noise.We then apply the fast Fourier transform and Gaussian low-pass filte rs to the synthetic images to re move noise and obtain accurate look angles for the soft X-ray pea ks.From the filte red images,we calculate RS and its accuracy for different LEXI locations,look directions,and solar wind densities by using the OpenGGCM subsolar magnetopause location as ground truth.Our method estimates RS with an accuracy of<0.3 RE when the solar wind density exceeds>10 cm-3.The accuracy improves for greater solar wind densities and during southward interplanetary magnetic fields.The method ca ptures the magnetopause motion during southwa rd interplaneta ry magnetic field turnings.Consequently,the technique will enable quantitative analysis of the magnetopause motion and help reveal the dayside reconnection modes for dynamic solar wind conditions.This technique will suppo rt the LEXI and SMILE missions in achieving their scientific o bjectives.
文摘Throughout the SMILE mission the satellite will be bombarded by radiation which gradually damages the focal plane devices and degrades their performance.In order to understand the changes of the CCD370s within the soft X-ray Imager,an initial characterisation of the devices has been carried out to give a baseline performance level.Three CCDs have been characterised,the two flight devices and the flight spa re.This has been carried out at the Open University in a bespo ke cleanroom measure ment facility.The results show that there is a cluster of bright pixels in the flight spa re which increases in size with tempe rature.However at the nominal ope rating tempe rature(-120℃) it is within the procure ment specifications.Overall,the devices meet the specifications when ope rating at -120℃ in 6 × 6 binned frame transfer science mode.The se rial charge transfer inefficiency degrades with temperature in full frame mode.However any charge losses are recovered when binning/frame transfer is implemented.