期刊文献+
共找到24,614篇文章
< 1 2 250 >
每页显示 20 50 100
Metal-Halide Perovskite Submicrometer-Thick Films for Ultra-Stable Self-Powered Direct X-Ray Detectors
1
作者 Marco Girolami Fabio Matteocci +7 位作者 Sara Pettinato Valerio Serpente Eleonora Bolli Barbara Paci Amanda Generosi Stefano Salvatori Aldo Di Carlo Daniele M.Trucchi 《Nano-Micro Letters》 SCIE EI CAS CSCD 2024年第9期410-431,共22页
Metal-halide perovskites are revolutionizing the world of X-ray detectors,due to the development of sensitive,fast,and cost-effective devices.Self-powered operation,ensuring portability and low power consumption,has a... Metal-halide perovskites are revolutionizing the world of X-ray detectors,due to the development of sensitive,fast,and cost-effective devices.Self-powered operation,ensuring portability and low power consumption,has also been recently demonstrated in both bulk materials and thin films.However,the signal stability and repeatability under continuous X-ray exposure has only been tested up to a few hours,often reporting degradation of the detection performance.Here it is shown that self-powered direct X-ray detectors,fabricated starting from a FAPbBr_(3)submicrometer-thick film deposition onto a mesoporous TiO_(2)scaffold,can withstand a 26-day uninterrupted X-ray exposure with negligible signal loss,demonstrating ultra-high operational stability and excellent repeatability.No structural modification is observed after irradiation with a total ionizing dose of almost 200 Gy,revealing an unexpectedly high radiation hardness for a metal-halide perovskite thin film.In addition,trap-assisted photoconductive gain enabled the device to achieve a record bulk sensitivity of 7.28 C Gy^(−1)cm^(−3)at 0 V,an unprecedented value in the field of thin-film-based photoconductors and photodiodes for“hard”X-rays.Finally,prototypal validation under the X-ray beam produced by a medical linear accelerator for cancer treatment is also introduced. 展开更多
关键词 Metal-halide perovskite thin films Direct x-ray detectors Self-powered devices Operational stability Medical linear accelerator
下载PDF
Design of the solar X-ray detector for the Macao Science Satellite-1B 被引量:1
2
作者 YongQiang Shi LianSheng Li +5 位作者 JianWu Chen FuChang Zuo XiaoPing Zhang ZhiWu Mei Li Wang Keke Zhang 《Earth and Planetary Physics》 EI CSCD 2023年第1期125-130,共6页
The solar X-ray detector(SXD)onboard the Macao Science Satellite-1B was designed to monitor solar flare bursts and to study the solar activity in the 25th solar cycle.The SXD includes two parts:a soft X-ray detection ... The solar X-ray detector(SXD)onboard the Macao Science Satellite-1B was designed to monitor solar flare bursts and to study the solar activity in the 25th solar cycle.The SXD includes two parts:a soft X-ray detection unit and a hard X-ray detection unit.Both the soft X-ray detection unit and the hard X-ray detection unit include two collimators,two X-ray detectors(a silicon drift detector and a cadmium-zinc-telluride detector),and a processing circuit.Compared with similar instruments,the energy range of the SXD is wider(1–600 ke V)and the energy resolution is better(150 e V at 5.9 ke V,12%at 59.5 ke V,and 3%at 662 keV). 展开更多
关键词 Macao Science Satellite-1B(MSS-1B) solar x-ray detector solar x-ray SPECTROMETER
下载PDF
A characterization study on perovskite X-ray detector performance based on a digital radiography system
3
作者 Yang Wang Qiong Zhang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第5期56-66,共11页
X-ray imaging technologies such as digital radiography(DR),is an important aspect of modern non-destructive testing and medical diagnosis.Innovative flexible X-ray detector technologies have recently been proposed and... X-ray imaging technologies such as digital radiography(DR),is an important aspect of modern non-destructive testing and medical diagnosis.Innovative flexible X-ray detector technologies have recently been proposed and are now receiving increasing attention owing to their superior material flexibility compared with traditional flat-panel detectors.This work aims to study these innovative flexible X-ray detectors in terms of their effectiveness in DR imaging,such as detection efficiency and spatial resolution.To achieve this goal,first,a Monte Carlo model was developed and calibrated to an in-lab 150 kV DR imaging system containing a flat-panel X-ray detector.Second,the validated model was updated with various types of flexible X-ray detectors to assess their performance in nearly realistic conditions.Key parameters such as the detection efficiency pertaining to the crystal material and thickness were studied and analyzed across a broader energy range up to 662 keV.Finally,the imaging performance of the different detectors was evaluated and compared to that of the flat-panel detector in the 150 kV DR imaging system.The results show that the flexible detectors such as the CsPbBr3crystal detector deliver promising performance in X-ray imaging and can be applied to a wider range of application scenarios,especially those requiring accurate detection at challenging angles. 展开更多
关键词 Flexible x-ray detector DR imaging system Monte Carlo simulation
下载PDF
Direct Conversion X-Ray Detectors with High Sensitivity at Low Dose Rate Based on All-Inorganic Lead-Free Perovskite Wafers
4
作者 Cuixian Zhang 《Detection》 2022年第2期13-27,共15页
Just as lead-based perovskites that are hot in solar cell preparation, Bi-based perovskites have demonstrated excellent performance in direct X-ray detection, especially the Cs<sub>3</sub>Bi<sub>2<... Just as lead-based perovskites that are hot in solar cell preparation, Bi-based perovskites have demonstrated excellent performance in direct X-ray detection, especially the Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub> single crystals (SCs). However, compared with lead-halide perovskites, one challenge for the Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub> SCs for X-ray detection application is that it is difficult to prepare large-sized and high-quality SCs. Therefore, how to get a large area with a high-quality wafer is also as important as Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub> growth method research. Here, different anti-solvents are used for the preparation of poly-crystalline powder with the Antisolvents precipitation (A) method, as a control, High-energy ball milling (B) was also used to prepare poly-crystalline powders. The resultant two types of Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub> wafer exhibit a micro-strain of 1.21 × 10<sup>-3</sup>, a resistivity of 5.13 × 10<sup>8</sup> Ω cm and a microstrain of 1.21 × 10<sup>-3</sup>, a resistivity of 2.21 × 10<sup>9</sup> Ω cm. As a result, an X-ray detector based on the high-quality Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub> wafer exhibits excellent dose rate linearity, a sensitivity of 588 μC·Gyairs<sup>-1</sup>·cm<sup>-2</sup> and a limit of detection (LoD) of 76 nGyair·s<sup>-1</sup>. 展开更多
关键词 x-ray Detection Sensitivity Cs3Bi2I9
下载PDF
Highly sensitive diamond X-ray detector array for high-temperature applications
5
作者 Wenjie Dou Chaonan Lin +8 位作者 Wei Fan Xun Yang Chao Fang Huaping Zang Shaoyi Wang Congxu Zhu Zhi Zheng Weimin Zhou Chongxin Shan 《Chip》 EI 2024年第3期43-49,共7页
Diamond is a highly suitable material for X-ray detectors that can function effectively in harsh environments due to its unique properties such as ultrawide bandgap,high radiation resistance,excellent carrier mobility... Diamond is a highly suitable material for X-ray detectors that can function effectively in harsh environments due to its unique properties such as ultrawide bandgap,high radiation resistance,excellent carrier mobility as well as remarkable chemical and thermal stability.However,the sensitivity of diamond X-ray detectors needs further improvement due to the relatively low X-ray absorption efficiency of diamond,and the exploration of singlecrystal diamond array imaging still remains unexplored.In the current work,a 10310 X-ray photodetector array was constructed from single-crystal diamond.To improve the sensitivity of the diamond X-ray detector,an asymmetric sandwich electrode structure was utilized.Additionally,trenches were created through laser cutting to prevent crosstalk between adjacent pixels.The diamond X-ray detector array exhibits exceptional performance,including a low detection limit of 4.9 nGy s^(-1),a sensitivity of 14.3 mC Gy^(-1) cm^(-2),and a light-dark current ratio of 18,312,which are among the most favorable values ever reported for diamond X-ray detectors.Furthermore,these diamond X-ray detectors can operate at high temperatures up to 450℃,making them suitable for development in harsh environments. 展开更多
关键词 DIAMOND x-ray detector array x-ray imaging Sensi-tivity Detection limit
原文传递
Design and technology review of the solar X-ray detector onboard the Macao Science Satellite-1B
6
作者 ZUO FuChang SHI YongQiang +15 位作者 CHEN JianWu ZHANG XiaoPing FU WeiChun CHANG Ye GAI FangQin LIU SiYuan XIONG Yan ZHANG HaiLi SUN Yan WANG Li ZHENG Ran LI LianSheng MEI ZhiWu HUANG He ZHA GangQiang ZHANG KeKe 《Science China(Technological Sciences)》 SCIE EI CAS 2024年第11期3365-3380,共16页
On May 21,2023,the Macao Science Satellite-1B(MSS-1B),a low-inclination,low-latitude,and high-precision scientific exploration satellite for geomagnetic fields and space environments,was successfully launched.The sola... On May 21,2023,the Macao Science Satellite-1B(MSS-1B),a low-inclination,low-latitude,and high-precision scientific exploration satellite for geomagnetic fields and space environments,was successfully launched.The solar X-ray detector(SXD),one of the two major scientific payloads onboard the MSS-1B,has obtained a large amount of solar X-ray radiation data,which reveals the distribution law of the magnetic field in the low Earth orbit,as well as the coupling law of the Earth's magnetic field and the solar radiation and energy particle distributions.First,the overall design of the multi-detection-unit,broad-energy-range,small-volume,and low-power SXD was implemented to achieve the scientific objectives of the mission.Second,the technical indicators of the instrument were decomposed into various components,and the key technologies,such as collimator,processing circuit,thermal,and payload dataset designs,were reviewed.Third,the backgrounds,including electronic noise,cosmic diffuse X-ray background,and high-energy background in the Earth's radiation belts in and out of the field of view,were analyzed for the instrument.Then,the ground calibrations of the energy response,detection efficiency,and temperature-dependent peak drift of the SXD flight model were conducted.Finally,the in-orbit temperature,energy spectrum data,background,and solar flare process observation of the instrument in the in-orbit test stage are presented,verifying the instrument design,analysis,and ground calibration,providing a foundation for obtaining accurate solar X-ray radiation data,and achieving the scientific objectives of the satellite. 展开更多
关键词 Macao Science Satellite-1B solar x-ray detector design and development solar flare technology review
原文传递
Gas microchannel plate-pixel detector for X-ray polarimetry
7
作者 Huan-Bo Feng Hong-Bang Liu +16 位作者 Dong Wang Zi-Li Li Shu-Lin Liu Qian Liu Hang-Zhou Li Bin-Long Wang Yan-Jun Xie Zong-Wang Fan Hui Wang Ran Chen Di-Fan Yi Rui-Ting Ma Fei Xie Bo Peng Xiang-Ming Sun Jin Li En-Wei Liang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第5期60-73,共14页
POLAR-2 is a gamma-ray burst(GRB)polarimeter that is designed to study the polarization in GRB radiation emissions,aiming to improve our knowledge of related mechanisms.POLAR-2 is expected to utilize an on-board polar... POLAR-2 is a gamma-ray burst(GRB)polarimeter that is designed to study the polarization in GRB radiation emissions,aiming to improve our knowledge of related mechanisms.POLAR-2 is expected to utilize an on-board polarimeter that is sensitive to soft X-rays(2-10 keV),called low-energy polarization detector.We have developed a new soft X-ray polari-zation detector prototype based on gas microchannel plates(GMCPs)and pixel chips(Topmetal).The GMCPs have bulk resistance,which prevents charging-up effects and ensures gain stability during operation.The detector is composed of low outgassing materials and is gas-sealed using a laser welding technique,ensuring long-term stability.A modulation factor of 41.28%±0.64% is obtained for a 4.5 keV polarized X-ray beam.A residual modulation of 1.96%±0.58% at 5.9 keV is observed for the entire sensitive area. 展开更多
关键词 x-ray polarimetry Gas microchannel plate-pixel detector Gamma-ray bursts
下载PDF
Orientation and mobility control of 4HCB organic film for flexible X-ray detectors with high performance
8
作者 Meng Xu Menghua Zhu +8 位作者 Dou Zhao Sixin Chen Shilin Liu Quanchao Zhang Pei Yuan Binbin Zhang Paul Sellin Wanqi Jie Yadong Xu 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2023年第4期46-53,共8页
In comparison to inorganic counterparts,organic semiconducting(OSC)crystalline films are promising for building large-area and flexible ionizing radiation detectors for X-ray imaging or dosimetry due to their tissue e... In comparison to inorganic counterparts,organic semiconducting(OSC)crystalline films are promising for building large-area and flexible ionizing radiation detectors for X-ray imaging or dosimetry due to their tissue equivalence,simple processing and large-scale production accessibility.Fabrication processes,how-ever,hinder the ability to generate aligned and large-area films with high carrier mobility.In this work,the space-confined melt process is used to produce highly orientated 4HCB(4-hydroxycyanobenzene)OSC films with a large area of 15×18 mm^(2).The out-of-plane direction of the 4HCB film is<001>,and the benzene rings are found to be extensively overlapped inside the in-plane direction,according to the XRD patterns.The film exhibits a high resistivity up to 1012cm,and high hole mobility of 10.62 cm^(2)V^(−1)s^(−1).Furthermore,the 4HCB(80μm-thick film)based X-ray detectors can achieve a sensitivity of 93μC Gy air^(−1) cm^(−2)and on/offratio of 157.The device also shows steady flexibility,with no degradation in detecting function after 100 cycles of bending.Finally,the proposed 4HCB film detectors demonstrated a high-resolution X-ray imaging capability.The imaging of several materials with sharp edges(copper and polytetrafluoroethylene)has been obtained.This work has developed a fast but efficient approach for producing large-area,highly oriented OSC films for high-performance X-ray detectors. 展开更多
关键词 Organic semiconducting films Highly oriented x-ray detector x-ray imaging Wearable detector
原文传递
Recent advances on two-dimensional metal halide perovskite x-ray detectors
9
作者 Mingyue Han Yingrui Xiao +7 位作者 Chao Zhou Yuxuan Yang Xiaoxue Wu Qi Hu Xi Jin Wei Zhang Jin-Song Hu Yan Jiang 《Materials Futures》 2023年第1期71-91,共21页
In recent years,two-dimensional metal halide perovskites(MHPs)have attracted increased attention for radiation detection and imaging.Their detection efficiencies are almost comparable to three-dimensional(3D)perovskit... In recent years,two-dimensional metal halide perovskites(MHPs)have attracted increased attention for radiation detection and imaging.Their detection efficiencies are almost comparable to three-dimensional(3D)perovskites.Meanwhile,they demonstrate superior stability to 3D perovskites.The pursuit of high-quality,phase-pure and lead-free two-dimensional MHP materials and large-area fabrication capability for x-ray detectors are among the research hotspots.In this review,we first give a brief introduction of the crystallographic structure,optoelectronic characteristics and preparation methods of high-quality two-dimensional perovskites.In addition,we overview the general working principles of direct and indirect x-ray detection processes and the corresponding performance metrics from the perspective of detection and imaging.Furthermore,we provide a comprehensive discussion on the recent advances in 2D perovskite x-ray detectors and imaging devices.Finally,we pinpoint several major obstacles of 2D x-ray detectors that should be overcome in the near future. 展开更多
关键词 TWO-DIMENSIONAL metal halide perovskites growth methods scintillator x-ray detector and imaging
原文传递
Low-noise and low-power pixel sensor chip for gas pixel detectors
10
作者 Zhuo Zhou Shi-Qiang Zhou +8 位作者 Dong Wang Xiang-Ming Sun Chao-Song Gao Peng-Zhen Zhu Wei-Ping Ren Jun Liu Mu-Xian Li Chen Lian Chun-Lai Dong 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第3期142-152,共11页
Topmetal-M2 is a large-area pixel sensor chip fabricated using the GSMC 130 nm CMOS process in 2021.The pixel array of Topmetal-M2 consists of pixels of 400 rows×512 columns with a pixel pitch of 45μm×45μm... Topmetal-M2 is a large-area pixel sensor chip fabricated using the GSMC 130 nm CMOS process in 2021.The pixel array of Topmetal-M2 consists of pixels of 400 rows×512 columns with a pixel pitch of 45μm×45μm.The array is divided into 16 subarrays,with pixels of 400 rows×32 columns per subarray.Each pixel incorporates two charge sensors:a diode sensor and a Topmetal sensor.The in-pixel circuit primarily consists of a charge-sensitive amplifier for energy measurements,a discriminator with a peak-holding circuit,and a time-to-amplitude converter for time-of-arrival measurements.The pixel of Topmetal-M2 has a charge input range of~0-3 k e-,a voltage output range of~0-180 mV,and a charge-voltage conversion gain of~59.56μV∕e-.The average equivalent noise charge of Topmetal-M2,which includes the readout electronic system noise,is~43.45 e-.In the scanning mode,the time resolution of Topmetal-M2 is 1 LSB=1.25μs,and the precision is^()7.41μs.At an operating voltage of 1.5 V,Topmetal-M2 has a power consumption of~49 mW∕cm~2.In this article,we provide a comprehensive overview of the chip architecture,pixel working principles,and functional behavior of Topmetal-M2.Furthermore,we present the results of preliminary tests conducted on Topmetal-M2,namely,alpha-particle and soft X-ray tests. 展开更多
关键词 Charge collection Gas detectors Semiconductor detectors x-ray detectors
下载PDF
Two-Dimensional Perovskite Single Crystals for High-Performance X-ray Imaging and Exploring MeV X-ray Detection
11
作者 Xieming Xu Yiheng Wu +5 位作者 Yi Zhang Xiaohui Li Fang Wang Xiaoming Jiang Shaofan Wu Shuaihua Wang 《Energy & Environmental Materials》 SCIE EI CAS CSCD 2024年第1期139-146,共8页
Scintillation semiconductors play increasingly important medical diagnosis and industrial inspection roles.Recently,two-dimensional(2D)perovskites have been shown to be promising materials for medical X-ray imaging,bu... Scintillation semiconductors play increasingly important medical diagnosis and industrial inspection roles.Recently,two-dimensional(2D)perovskites have been shown to be promising materials for medical X-ray imaging,but they are mostly used in low-energy(≤130 keV)regions.Direct detection of MeV X-rays,which ensure thorough penetration of the thick shell walls of containers,trucks,and aircraft,is also highly desired in practical industrial applications.Unfortunately,scintillation semiconductors for high-energy X-ray detection are currently scarce.Here,This paper reports a 2D(C_(4)H_(9)NH_(3))_(2)PbBr_(4)single crystal with outstanding sensitivity and stability toward X-ray radiation that provides an ultra-wide detectable X-ray range of between 8.20 nGy_(air)s^(-1)(50 keV)and 15.24 mGy_(air)s^(-1)(9 MeV).The(C_(4)H_(9)NH_(3))_(2)PbBr_(4)single-crystal detector with a vertical structure is used for high-performance X-ray imaging,delivering a good spatial resolution of 4.3 Ip mm^(-1)in a plane-scan imaging system.Low ionic migration in the 2D perovskite enables the vertical device to be operated with hundreds of keV to MeV X-ray radiation at high bias voltages,leading to a sensitivity of 46.90μC Gy_(air)-1 cm^(-2)(-1.16 Vμm^(-1))with 9 MeV X-ray radiation,demonstrating that 2D perovskites have enormous potential for high-energy industrial applications. 展开更多
关键词 MeV x-ray detection single-crystal x-ray detectors two-dimensional perovskites x-ray imaging
下载PDF
Electronics system for the cosmic X-ray polarization detector 被引量:2
12
作者 Hui Wang Dong Wang +13 位作者 Ran Chen Yan-Wei Kui Hong-Bang Liu Zong-Wang Fan Huan-Bo Feng Jin Li Jun Liu Qian Liu Shi Chen Yuan-Kang Yang Zhuo Zhou Zi-Li Li Shi-Qiang Zhou Ni Fang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第5期1-12,共12页
This study presents an electronics system for cosmic X-ray polarization detection(CXPD).The CXPD was designed as a high-sensitivity soft X-ray polarimeter with a measurement energy range of 2-10 keV carried by a CubeS... This study presents an electronics system for cosmic X-ray polarization detection(CXPD).The CXPD was designed as a high-sensitivity soft X-ray polarimeter with a measurement energy range of 2-10 keV carried by a CubeSat.A stable and functionally complete electronics system under power and space constraints is a key challenge.The complete CXPD electronics system(CXPDES)comprises hardware and firmware.CXPDES adopts a three-layer electronic board structure based on functionality and available space.Two gas pixel detectors(GPDs)were placed on the top layer board,and CXPDES provided the GPDs with voltages up to-4000 V.Each GPD signal was digitized,compressed,encoded,and stored before being transmitted to the ground.The CXPDES provided stable and high-speed communication based on a scheme that separated command and data transmission,and it supports the CXPDES in-orbit upgrade.In addition,environmental monitors,silicon photomultiplier(SiPM)triggers,power management,GPDs configuration,and mode switches were included in the overall operating logic of the CXPDES.The results obtained by testing the CXPDES showed that it satisfied all the requirements of CXPD.The CXPDES provides design experience and technological readiness for future large-area X-ray polarimetry missions. 展开更多
关键词 x-ray polarimeter ELECTRONICS CUBESAT Gas pixel detector FPGA
下载PDF
X-ray在鱼体组织及微量元素检测中的应用
13
作者 宋一帆 张胜茂 +4 位作者 张衡 唐峰华 张寒野 石永闯 崔雪森 《应用光学》 CAS 北大核心 2024年第1期166-176,共11页
鱼类硬质组织物,特别是骨骼支持鱼体和保护其体内器官的组织,对其进行特征检测分析是研究鱼类游泳运动、鱼类解剖、鱼体建模等的数据基础。随着X-ray技术的发展和国产设备的广泛应用,其仪器设备成本明显降低,使得X-ray在渔业研究与自动... 鱼类硬质组织物,特别是骨骼支持鱼体和保护其体内器官的组织,对其进行特征检测分析是研究鱼类游泳运动、鱼类解剖、鱼体建模等的数据基础。随着X-ray技术的发展和国产设备的广泛应用,其仪器设备成本明显降低,使得X-ray在渔业研究与自动化生产中的应用成为可能。首先介绍了X-ray技术的基本原理与其在鱼体组织检测中的应用,X-ray技术在鱼体组织及微量元素检测中的应用主要分为鱼类组织器官的无损检测和鱼体微量元素检测两部分,其中分别介绍了包括照相法、数字成像法、衍射技术和吸收光谱法等X-ray技术;然后综述其在鱼体组织器官建模、鱼骨检测、鱼类化石研究、鱼耳石分析和鱼体微量元素检测方面的应用,总结了Xray在渔业领域应用中存在的问题;最后对X-ray的渔业应用方向进行展望。 展开更多
关键词 x-ray 鱼体骨骼 鱼类耳石 鱼体建模 鱼体微量元素
下载PDF
Global hybrid simulations of soft X-ray emissions in the Earth’s magnetosheath 被引量:2
14
作者 Jin Guo TianRan Sun +6 位作者 San Lu QuanMing Lu Yu Lin XueYi Wang Chi Wang RongSheng Wang Kai Huang 《Earth and Planetary Physics》 EI CSCD 2024年第1期47-58,共12页
Earth’s magnetopause is a thin boundary separating the shocked solar wind plasma from the magnetospheric plasmas,and it is also the boundary of the solar wind energy transport to the magnetosphere.Soft X-ray imaging ... Earth’s magnetopause is a thin boundary separating the shocked solar wind plasma from the magnetospheric plasmas,and it is also the boundary of the solar wind energy transport to the magnetosphere.Soft X-ray imaging allows investigation of the large-scale magnetopause by providing a two-dimensional(2-D)global view from a satellite.By performing 3-D global hybrid-particle-in-cell(hybrid-PIC)simulations,we obtain soft X-ray images of Earth’s magnetopause under different solar wind conditions,such as different plasma densities and directions of the southward interplanetary magnetic field.In all cases,magnetic reconnection occurs at low latitude magnetopause.The soft X-ray images observed by a hypothetical satellite are shown,with all of the following identified:the boundary of the magnetopause,the cusps,and the magnetosheath.Local X-ray emissivity in the magnetosheath is characterized by large amplitude fluctuations(up to 160%);however,the maximum line-of-sight-integrated X-ray intensity matches the tangent directions of the magnetopause well,indicating that these fluctuations have limited impact on identifying the magnetopause boundary in the X-ray images.Moreover,the magnetopause boundary can be identified using multiple viewing geometries.We also find that solar wind conditions have little effect on the magnetopause identification.The Solar wind Magnetosphere Ionosphere Link Explorer(SMILE)mission will provide X-ray images of the magnetopause for the first time,and our global hybrid-PIC simulation results can help better understand the 2-D X-ray images of the magnetopause from a 3-D perspective,with particle kinetic effects considered. 展开更多
关键词 MAGNETOPAUSE x-ray emissivity x-ray imaging SMILE global hybrid-PIC simulation
下载PDF
The Soft X-ray Imager(SXI)on the SMILE Mission 被引量:4
15
作者 S.Sembay A.L.Alme +83 位作者 D.Agnolon T.Arnold A.Beardmore A.Belén Balado Margeli C.Bicknell C.Bouldin G.Branduardi-Raymont T.Crawford J.P.Breuer T.Buggey G.Butcher R.Canchal J.A.Carter A.Cheney Y.Collado-Vega H.Connor T.Crawford N.Eaton C.Feldman C.Forsyth T.Frantzen G.Galgóczi J.Garcia G.Y.Genov C.Gordillo H-P.Gröbelbauer M.Guedel Y.Guo M.Hailey D.Hall R.Hampson J.Hasiba O.Hetherington A.Holland S-Y.Hsieh M.W.J.Hubbard H.Jeszenszky M.Jones T.Kennedy K.Koch-Mehrin S.Kögl S.Krucker K.D.Kuntz C.Lakin G.Laky O.Lylund A.Martindale J.Miguel Mas Hesse R.Nakamura K.Oksavik N.Østgaard H.Ottacher R.Ottensamer C.Pagani S.Parsons P.Patel J.Pearson G.Peikert F.S.Porter T.Pouliantis B.H.Qureshi W.Raab G.Randal A.M.Read N.M.M.Roque M.E.Rostad C.Runciman S.Sachdev A.Samsonov M.Soman D.Sibeck S.Smit J.Søndergaard R.Speight S.Stavland M.Steller TianRan Sun J.Thornhill W.Thomas K.Ullaland B.Walsh D.Walton C.Wang S.Yang 《Earth and Planetary Physics》 EI CSCD 2024年第1期5-14,共10页
The Soft X-ray Imager(SXI)is part of the scientific payload of the Solar wind Magnetosphere Ionosphere Link Explorer(SMILE)mission.SMILE is a joint science mission between the European Space Agency(ESA)and the Chinese... The Soft X-ray Imager(SXI)is part of the scientific payload of the Solar wind Magnetosphere Ionosphere Link Explorer(SMILE)mission.SMILE is a joint science mission between the European Space Agency(ESA)and the Chinese Academy of Sciences(CAS)and is due for launch in 2025.SXI is a compact X-ray telescope with a wide field-of-view(FOV)capable of encompassing large portions of Earth’s magnetosphere from the vantage point of the SMILE orbit.SXI is sensitive to the soft X-rays produced by the Solar Wind Charge eXchange(SWCX)process produced when heavy ions of solar wind origin interact with neutral particles in Earth’s exosphere.SWCX provides a mechanism for boundary detection within the magnetosphere,such as the position of Earth’s magnetopause,because the solar wind heavy ions have a very low density in regions of closed magnetic field lines.The sensitivity of the SXI is such that it can potentially track movements of the magnetopause on timescales of a few minutes and the orbit of SMILE will enable such movements to be tracked for segments lasting many hours.SXI is led by the University of Leicester in the United Kingdom(UK)with collaborating organisations on hardware,software and science support within the UK,Europe,China and the United States. 展开更多
关键词 Soft x-ray Imaging micropore optics large area CCD
下载PDF
PTW Detector7293种剂量验证方法在调强放射治疗中的对比研究
16
作者 吴晓辉 姚祖文 +4 位作者 徐珊珊 罗桃红 胡小容 姚阳 王晓华 《医疗卫生装备》 CAS 2024年第5期56-59,共4页
目的 :对比PTW Detector729 3种验证方法在调强放射治疗(intensity modulated radiation therapy,IMRT)剂量验证中的差异。方法:回顾性选取2022年1—12月于某院完成放射治疗的鼻咽癌、肺癌、乳腺癌、宫颈癌和全脑放射治疗患者共50例,使... 目的 :对比PTW Detector729 3种验证方法在调强放射治疗(intensity modulated radiation therapy,IMRT)剂量验证中的差异。方法:回顾性选取2022年1—12月于某院完成放射治疗的鼻咽癌、肺癌、乳腺癌、宫颈癌和全脑放射治疗患者共50例,使用PTW Detector729二维电离室矩阵配合PTW RW3固体水与PTW Ocavius 4D旋转模体对50例患者的IMRT计划分别进行归零机架角2D剂量验证、实际机架角2D剂量验证和实际机架角3D剂量验证。将剂量评估阈值设为10%,统计3种验证方法在3%/1 mm、2%/2 mm、3%/2 mm和3%/3 mm 4种评估标准下的γ通过率。采用SPSS 22.0统计学软件进行数据分析。结果:在10%剂量评估阈值标准下,归零机架角2D剂量验证的γ通过率最高,差异有统计学意义(P<0.05);实际机架角2D剂量验证的γ通过率高于实际机架角3D剂量验证,差异有统计学意义(P<0.05)。3种验证方法的γ通过率在3%/1 mm、2%/2 mm、3%/2 mm和3%/3 mm 4种标准下逐渐升高,且在3%/2 mm标准下均超过90%,结果满足临床放射治疗要求。结论:3种验证方法的验证结果均能达到IMRT剂量验证实践指南要求,根据IMRT开展情况选择合适的验证方法,对确保治疗方案安全、有效实施具有重要意义。 展开更多
关键词 PTW detector729 二维电离室矩阵 剂量验证 γ通过率 调强放射治疗
下载PDF
Two methods for separating the magnetospheric solar wind charge exchange soft X-ray emission from the diffuse X-ray background 被引量:2
17
作者 YingJie Zhang TianRan Sun +5 位作者 JenniferACarter WenHao Liu Steve Sembay ShuiNai Zhang Li Ji Chi Wang 《Earth and Planetary Physics》 EI CSCD 2024年第1期119-132,共14页
Solar wind charge exchange(SWCX)is the process of solar wind high-valence ions exchanging charges with neutral components and generating soft X-rays.Recently,detecting the SWCX emission from the magnetosphere is propo... Solar wind charge exchange(SWCX)is the process of solar wind high-valence ions exchanging charges with neutral components and generating soft X-rays.Recently,detecting the SWCX emission from the magnetosphere is proposed as a new technique to study the magnetosphere using panoramic soft X-ray imaging.To better prepare for the data analysis of upcoming magnetospheric soft X-ray imaging missions,this paper compares the magnetospheric SWCX emission obtained by two methods in an XMM-Newton observation,during which the solar wind changed dramatically.The two methods differ in the data used to fit the diffuse X-ray background(DXB)parameters in spectral analysis.The method adding data from the ROSAT All-Sky Survey(RASS)is called the RASS method.The method using the quiet observation data is called the Quiet method,where quiet observations usually refer to observations made by the same satellite with the same target but under weaker solar wind conditions.Results show that the spectral compositions of magnetospheric SWCX emission obtained by the two methods are very similar,and the changes in intensity over time are highly consistent,although the intensity obtained by the RASS method is about 2.68±0.56 keV cm^(-2)s^(-1)sr^(-1)higher than that obtained by the Quiet method.Since the DXB intensity obtained by the RASS method is about 2.84±0.74 keV cm^(-2)s^(-1)sr^(-1)lower than that obtained by the Quiet method,and the linear correlation coefficient between the difference of SWCX and DXB obtained by the two methods in diffe rent energy band is close to-1,the diffe rences in magnetospheric SWCX can be fully attributed to the diffe rences in the fitted DXB.The difference between the two methods is most significant when the energy is less than 0.7 keV,which is also the main energy band of SWCX emission.In addition,the difference between the two methods is not related to the SWCX intensity and,to some extent,to solar wind conditions,because SWCX intensity typically va ries with the solar wind.In summary,both methods are robust and reliable,and should be considered based on the best available options. 展开更多
关键词 solar wind charge exchange(SWCX) ROSAT All-Sky Survey(RASS) soft x-ray x-ray imaging MAGNETOSPHERE
下载PDF
Finding the magnetopause location using soft X-ray observations and a statistical inverse method 被引量:1
18
作者 Gonzalo Cucho-Padin Hyunju Connor +2 位作者 Jaewoong Jung Brian Walsh David G.Sibeck 《Earth and Planetary Physics》 EI CSCD 2024年第1期184-203,共20页
Variability in the location and shape of the dayside magnetopause is attributed to magnetic reconnection,a fundamental process that enables the transfer of mass,energy,and momentum from the solar wind into the magneto... Variability in the location and shape of the dayside magnetopause is attributed to magnetic reconnection,a fundamental process that enables the transfer of mass,energy,and momentum from the solar wind into the magnetosphere.The spatial and temporal properties of the magnetopause,under varying solar and magnetospheric conditions,remain largely unknown because empirical studies using in-situ observations are challenging to interpret.Global wide field-of-view(FOV)imaging is the only means to simultaneously observe the spatial distribution of the plasma properties over the vast dayside magnetospheric region and,subsequently,quantify the energy transport from the interplanetary medium into the terrestrial magnetosphere.Two upcoming missions,ESA/CAS SMILE and NASA’s LEXI will provide wide-field imagery of the dayside magnetosheath in soft X-rays,an emission generated by charge exchange interactions between high charge-state heavy ions of solar wind origin and exospheric neutral atoms.High-cadence two-dimensional observations of the magnetosheath will allow the estimation of dynamic properties of its inner boundary,the magnetopause,and enable studies of its response to changes in the solar wind dynamic pressure and interplanetary magnetic field orientation.This work introduces a statistically-based estimation approach based on inverse theory to estimate the spatial distribution of magnetosheath soft X-ray emissivities and,with this,identify the location of the magnetopause over the Sun−Earth line.To do so,we simulate the magnetosheath structure using the MHD-based OpenGGCM model and generate synthetic soft X-ray images using LEXI’s orbit and attitude information.Our results show that 3-D estimations using the described statistically-based technique are robust against Poisson-distributed shot noise inherent to soft X-ray images.Also,our proposed methodology shows that the accuracy of both three-dimensional(3-D)estimation and the magnetopause standoff distance calculation highly depends on the observational point. 展开更多
关键词 MAGNETOPAUSE soft x-ray TOMOGRAPHY
下载PDF
Estimating the subsolar magnetopause position from soft X-ray images using a low-pass image filter 被引量:1
19
作者 Hyangpyo Kim Hyunju K.Connor +9 位作者 Jaewoong Jung Brian M.Walsh David Sibeck Kip D.Kuntz Frederick S.Porter Catriana K.Paw U Rousseau A.Nutter Ramiz Qudsi Rumi Nakamura Michael Collier 《Earth and Planetary Physics》 EI CSCD 2024年第1期173-183,共11页
The Lunar Environment heliospheric X-ray Imager(LEXI)and Solar wind Magnetosphere Ionosphere Link Explorer(SMILE)missions will image the Earth’s dayside magneto pause and cusps in soft X-rays after their respective l... The Lunar Environment heliospheric X-ray Imager(LEXI)and Solar wind Magnetosphere Ionosphere Link Explorer(SMILE)missions will image the Earth’s dayside magneto pause and cusps in soft X-rays after their respective launches in the near future,to specify glo bal magnetic reconnection modes for varying solar wind conditions.To suppo rt the success of these scientific missions,it is critical to develop techniques that extract the magnetopause locations from the observed soft X-ray images.In this research,we introduce a new geometric equation that calculates the subsolar magnetopause position(RS)from a satellite position,the look direction of the instrument,and the angle at which the X-ray emission is maximized.Two assumptions are used in this method:(1)The look direction where soft X-ray emissions are maximized lies tangent to the magnetopause,and(2)the magnetopause surface near the subsolar point is almost spherical and thus RSis nea rly equal to the radius of the magneto pause curvature.We create synthetic soft X-ray images by using the Open Geospace General Circulation Model(OpenGGCM)global magnetohydrodynamic model,the galactic background,the instrument point spread function,and Poisson noise.We then apply the fast Fourier transform and Gaussian low-pass filte rs to the synthetic images to re move noise and obtain accurate look angles for the soft X-ray pea ks.From the filte red images,we calculate RS and its accuracy for different LEXI locations,look directions,and solar wind densities by using the OpenGGCM subsolar magnetopause location as ground truth.Our method estimates RS with an accuracy of<0.3 RE when the solar wind density exceeds>10 cm-3.The accuracy improves for greater solar wind densities and during southward interplanetary magnetic fields.The method ca ptures the magnetopause motion during southwa rd interplaneta ry magnetic field turnings.Consequently,the technique will enable quantitative analysis of the magnetopause motion and help reveal the dayside reconnection modes for dynamic solar wind conditions.This technique will suppo rt the LEXI and SMILE missions in achieving their scientific o bjectives. 展开更多
关键词 soft x-ray MAGNETOPAUSE RECONNECTION low-pass filter LEXI SMILE
下载PDF
SMILE soft X-ray Imager flight model CCD370 pre-flight device characterisation 被引量:1
20
作者 S.Parsons D.J.Hall +4 位作者 O.Hetherington T.W.Buggey T.Arnold M.W.J.Hubbard A.Holland 《Earth and Planetary Physics》 EI CSCD 2024年第1期25-38,共14页
Throughout the SMILE mission the satellite will be bombarded by radiation which gradually damages the focal plane devices and degrades their performance.In order to understand the changes of the CCD370s within the sof... Throughout the SMILE mission the satellite will be bombarded by radiation which gradually damages the focal plane devices and degrades their performance.In order to understand the changes of the CCD370s within the soft X-ray Imager,an initial characterisation of the devices has been carried out to give a baseline performance level.Three CCDs have been characterised,the two flight devices and the flight spa re.This has been carried out at the Open University in a bespo ke cleanroom measure ment facility.The results show that there is a cluster of bright pixels in the flight spa re which increases in size with tempe rature.However at the nominal ope rating tempe rature(-120℃) it is within the procure ment specifications.Overall,the devices meet the specifications when ope rating at -120℃ in 6 × 6 binned frame transfer science mode.The se rial charge transfer inefficiency degrades with temperature in full frame mode.However any charge losses are recovered when binning/frame transfer is implemented. 展开更多
关键词 CCD soft x-ray imager characterisation SMILE
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部