X-ray diffraction investigation of amorphous calcium phosphate and hydroxyapatite under ultra-high hydrostatic pressure
1
作者 Elisa Lam Qinfen Gu +2 位作者 Peter J.Swedlund Sylvie Marchesseau Yacine Hemar 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2015年第11期1225-1231,共7页
The changes in the crystal structures of synthetically prepared amorphous calcium phosphate(ACP) and hydroxyapatite(HAP) in water(1:1 mass ratio) were studied by synchrotron X-ray diffraction(XRD) under ultra... The changes in the crystal structures of synthetically prepared amorphous calcium phosphate(ACP) and hydroxyapatite(HAP) in water(1:1 mass ratio) were studied by synchrotron X-ray diffraction(XRD) under ultra-high hydrostatic pressures as high as 2.34 GPa for ACP and 4 GPa for HAP. At ambient pressure, the XRD patterns of the ACP and HAP samples in capillary tubes and their environmental scanning electron micrographs indicated amorphous and crystalline characteristics for ACP and HAP, respectively. At pressures greater than 0.25 GPa, an additional broad peak was observed in the XRD pattern of the ACP phase, indicating a partial phase transition from an amorphous phase to a new high-pressure amorphous phase. The peak areas and positions of the ACP phase, as obtained through fitting of the experimental data, indicated that the ACP exhibited increased pseudo-crystalline behavior at pressures greater than 0.96 GPa. Conversely, no structural changes were observed for the HAP phase up to the highest applied pressure of 4 GPa. For HAP, a unit-cell reduction during compression was evidenced by a reduction in both refined lattice parameters a and c. Both ACP and HAP reverted to their original structures when the pressure was fully released to ambient pressure. 展开更多
关键词 calcium phosphate HYDROXYAPATITE high hydrostatic pressure x-ray diffraction
下载PDF
Microstructures and micromechanical behaviors of high -entropy alloys investigated by synchrotron X-ray and neutron diffraction techniques: A review 被引量:1
2
作者 Yubo Huang Ning Xu +3 位作者 Huaile Lu Yang Ren Shilei Li Yandong Wang 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2024年第6期1333-1349,共17页
High-entropy alloys(HEAs)possess outstanding features such as corrosion resistance,irradiation resistance,and good mechan-ical properties.A few HEAs have found applications in the fields of aerospace and defense.Exten... High-entropy alloys(HEAs)possess outstanding features such as corrosion resistance,irradiation resistance,and good mechan-ical properties.A few HEAs have found applications in the fields of aerospace and defense.Extensive studies on the deformation mech-anisms of HEAs can guide microstructure control and toughness design,which is vital for understanding and studying state-of-the-art structural materials.Synchrotron X-ray and neutron diffraction are necessary techniques for materials science research,especially for in situ coupling of physical/chemical fields and for resolving macro/microcrystallographic information on materials.Recently,several re-searchers have applied synchrotron X-ray and neutron diffraction methods to study the deformation mechanisms,phase transformations,stress behaviors,and in situ processes of HEAs,such as variable-temperature,high-pressure,and hydrogenation processes.In this review,the principles and development of synchrotron X-ray and neutron diffraction are presented,and their applications in the deformation mechanisms of HEAs are discussed.The factors that influence the deformation mechanisms of HEAs are also outlined.This review fo-cuses on the microstructures and micromechanical behaviors during tension/compression or creep/fatigue deformation and the application of synchrotron X-ray and neutron diffraction methods to the characterization of dislocations,stacking faults,twins,phases,and intergrain/interphase stress changes.Perspectives on future developments of synchrotron X-ray and neutron diffraction and on research directions on the deformation mechanisms of novel metals are discussed. 展开更多
关键词 high-entropy alloys MICROSTRUCTURES micromechanical behaviors synchrotron x-ray diffraction neutron diffraction
下载PDF
Intensity correlation properties of x-ray beams split with Laue diffraction
3
作者 赵昌哲 司尚禹 +3 位作者 张海鹏 薛莲 李中亮 肖体乔 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第1期379-383,共5页
Beam splitting is one of the main approaches to achieving x-ray ghost imaging, and the intensity correlation between diffraction beam and transmission beam will directly affect the imaging quality. In this paper, we i... Beam splitting is one of the main approaches to achieving x-ray ghost imaging, and the intensity correlation between diffraction beam and transmission beam will directly affect the imaging quality. In this paper, we investigate the intensity correlation between the split x-ray beams by Laue diffraction of stress-free crystal. The analysis based on the dynamical theory of x-ray diffraction indicates that the spatial resolution of diffraction image and transmission image are reduced due to the position shift of the exit beam. In the experimental setup, a stress-free crystal with a thickness of hundredmicrometers-level is used for beam splitting. The crystal is in a non-dispersive configuration equipped with a double-crystal monochromator to ensure that the dimension of the diffraction beam and transmission beam are consistent. A correlation coefficient of 0.92 is achieved experimentally and the high signal-to-noise ratio of the x-ray ghost imaging is anticipated.Results of this paper demonstrate that the developed beam splitter of Laue crystal has the potential in the efficient data acquisition of x-ray ghost imaging. 展开更多
关键词 x-ray ghost imaging beam splitting with Laue diffraction intensity correlation dynamical theory of x-ray diffraction
下载PDF
Direct observation of shock-induced phase transformation in polycrystalline iron via in situ x-ray diffraction
4
作者 Fan Zhang Jia-Qin Dong +11 位作者 Zhi-Yong Xie Zhi-Yu He Hua Shu Rui-Rong Wang Jun Xiong Guo Jia Zhi-Heng Fang Wei Wang Da-Wu Xiao An-Le Lei Jie Chen Xiu-Guang Huang 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第10期337-342,共6页
Phase transition of polycrystalline iron compressed along the Hugoniot is studied by combining laser-driven shock with in situ x-ray diffraction technique.It is suggested that polycrystalline iron changes from an init... Phase transition of polycrystalline iron compressed along the Hugoniot is studied by combining laser-driven shock with in situ x-ray diffraction technique.It is suggested that polycrystalline iron changes from an initial body-centered cubic structure to a hexagonal close-packed structure with increasing pressure(i.e.,a phase transition fromαtoε).The relationship between density and pressure for polycrystalline iron obtained from the present experiments is found to be in good agreement with the gas-gun Hugoniot data.Our results show that experiments with samples at lower temperatures under static loading,such as in a diamond anvil cell,lead to higher densities measured than those found under dynamic loading.This means that extrapolating results of static experiments may not predict the dynamic responses of materials accurately.In addition,neither the face-centered cubic structure seen in previous molecular-dynamics simulations or twophase coexistence are found within our experimental pressure range. 展开更多
关键词 in situ x-ray diffraction phase transition polycrystalline iron
下载PDF
A Novel High Temperature Apparatus for in situ Synchrotron X-ray Diffraction Studies of Molten Salt
5
作者 CAO Hui-li GAO Mei +5 位作者 Andebet G.Tamirat ZHAO Hong-bin ZHOU Xing-tai HUANG Yu-ying LEI Qi WEN Wen 《分析测试学报》 CAS CSCD 北大核心 2024年第10期1608-1617,共10页
This study demonstrates the design and application of a novel high temperature rotatory apparatus for insitu synchrotron X-ray diffraction studies of molten salts,facilitating investigation into the interaction betwee... This study demonstrates the design and application of a novel high temperature rotatory apparatus for insitu synchrotron X-ray diffraction studies of molten salts,facilitating investigation into the interaction between various structural materials and molten salts.The apparatus enables accurate detection of every phase change during hightemperature experiments,including strong reaction processes like corrosion.Molten salts,such as chlorides or fluo⁃rides,together with the structure materials,are inserted into either quartz or boron nitride capillaries,where X-ray diffraction pattern can be continuously collected,as the samples are heated to high temperature.The replacement re⁃action,when molten ZnCl2 are etching Ti3AlC2,can be clearly observed through changes in diffraction peak intensity as well as expansion in c-axis lattice parameter of the hexagonal matrix,due to the larger atomic number and ionic ra⁃dius of Zn2+.Furthermore,we investigated the high-temperature corrosion process when GH3535 alloy is in FLiNaK molten salt,and can help to optimize its stability for potential applications in molten salt reactor.Additionally,this high temperature apparatus is fully compatible with the combined usage of X-ray diffraction and Raman technique,providing both bulk and surface structural information.This high temperature apparatus has been open to users and is extensively used at BL14B1 beamline of the Shanghai Synchrotron Radiation Facility. 展开更多
关键词 in-situ x-ray diffraction rotary micro-diffractometer rotary high-temperature apparatus molten salt
下载PDF
Investigation of Peak Separation for X-ray Diffraction Profiles of Spinodal Decomposition by a Kind of Optimized Voigt Function 被引量:2
6
作者 LiudingWANG JunqiangZHOU +1 位作者 QuanxiCAO ZhaoCHEN 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2003年第4期371-373,共3页
The intensity and position of sidebands (satellites) on both sides of main diffraction peak in a great number of X-ray diffraction profiles of alloys always change with progress of aging. The sidebands position is det... The intensity and position of sidebands (satellites) on both sides of main diffraction peak in a great number of X-ray diffraction profiles of alloys always change with progress of aging. The sidebands position is determined by a newly optimized Voigt function in present investigation. Furthermore, for Cu-4 wt pet Ti alloy aged at 400℃ for 720 min and 1080 min, after introducing the weight factor of above two satellites intensity, the relative error between the fitting curves and X-ray diffraction profiles is less than 0.185%, which is more precise than the previously calculating result. 展开更多
关键词 x-ray diffraction diffraction profile Peak separation Voigt function
下载PDF
In situ X-ray diffraction investigation of compression behavior in Gd_(40)Y_(16)Al_(24)Co_(20) bulk metallic glass under high pressure with synchrotron radiation 被引量:3
7
作者 徐涛 黄蕾 +4 位作者 董雁国 李工 李延春 刘景 刘日平 《Chinese Physics C》 SCIE CAS CSCD 2009年第11期1028-1032,共5页
The compression behavior of the heavy RE-based BMC Gd40Y16Al24Co20 under high pressure has been investigated by in situ high pressure angle dispersive X-ray diffraction measurements using synchrotron radiation in the ... The compression behavior of the heavy RE-based BMC Gd40Y16Al24Co20 under high pressure has been investigated by in situ high pressure angle dispersive X-ray diffraction measurements using synchrotron radiation in the pressure range of 0-33.42 GPa at room temperature. By fitting the static equation of state at room temperature, we find the value of bulk modulus B is 61.27±4 GPa which is in good agreement with the experimental study by pulse-echo techniques of 58 GPa. The results show that the amorphous structure in the heavy RE-based BMG Gd40Y16Al24Co20 keeps quite stable up to 33.42 GPa although its compressibility is as large as about 33%. The coexistence of normal local structure similar to that of other BMGs and covalent bond structure similar to those of oxide glasses may be the reason for the anomalous property under high pressure of the Gd4oY16Al24Co2o BMG. 展开更多
关键词 bulk metallic glass In situ x-ray diffraction compression behavior high pressure synchrotronradiation
原文传递
Investigation of Ge-Si Atomic Interdiffusion in Ge Nano-dots Multilayer Structure by Double Crystal X-ray Diffraction
8
作者 Wenhua SHI Lei ZHAO Liping LUO Qiming WANG 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2007年第3期301-303,共3页
The fluctuations of the strained layer in a superlattice or quantum well can broaden the width of satellite peaks in double crystal X-ray diffraction (DCXRD) pattern. It is found that the width of the 0^th peak is ... The fluctuations of the strained layer in a superlattice or quantum well can broaden the width of satellite peaks in double crystal X-ray diffraction (DCXRD) pattern. It is found that the width of the 0^th peak is directly proportional to the fluctuation of the strained layer if the other related facts are ignored. By this method, the Ge-Si atomic interdiffusion in Ge nano-dots and wetting layers has been investigated by DCXRD. It is found that thermal annealing can activate Ge-Si atomic interdiffusion and the interdiffusion in the nano-dots area is much stronger than that in the wetting layer area. Therefore the fluctuation of the Ge layer decreases and the distribution of Ge atoms becomes homogeneous in the horizontal Ge (GeSi actually) layer, which make the width of the 0^th peak narrow after annealing. 展开更多
关键词 x-ray diffraction GESI Nano-dots Annealing ISLAND
下载PDF
Investigation on the 773 K isothermal section of La-Fe-Sn ternary systems by X-ray powder diffraction
9
作者 CHEN Xiang ZHUANG Yinghong CHEN Yungui 《Rare Metals》 SCIE EI CAS CSCD 2010年第6期567-571,共5页
The 773 K isothermal section of the La-Fe-Sn ternary system was investigated and constructed by X-ray powder diffraction(XRD).The existence of two reported ternary intermetallic compounds,La6Fe13Sn and La3FeSn6,is c... The 773 K isothermal section of the La-Fe-Sn ternary system was investigated and constructed by X-ray powder diffraction(XRD).The existence of two reported ternary intermetallic compounds,La6Fe13Sn and La3FeSn6,is confirmed in this work.Compared with other R-Fe-Sn phase diagrams(R = Pr and Sm),the binary alloys Fe3Sn and Fe5Sn3 are not present.The compound Fe3Sn2 was observed from the XRD pattern of Fe3Sn2 samples,but it is not an equilibrium phase at 773 K and decomposes into Fe and FeSn phases completely for a longer heat treated time.Up to now,the crystal structure data of La2Sn3 has not been reported,so the X-ray pattern of La2Sn3 was only estimated.The phase relationship for this compound was drawn by a dotted line. 展开更多
关键词 INTERMETALLICS QUENCHING phase diagrams x-ray diffraction.
下载PDF
High-pressure investigations on Piplia Kalan eucrite meteorite using in-situ X-ray diffraction and ^(57)Fe Mssbauer spectroscopic technique up to 16 GPa
10
作者 Usha Chandra K.K. Pandey +1 位作者 G. Parthasarathy Surinder M. Sharma 《Geoscience Frontiers》 SCIE CAS CSCD 2016年第2期265-271,共7页
We report here high-pressure investigations on Piplia Kalan eucrite-a member of HED (Howardite -Eucrite-Diogenite) family from asteroid 4-Vesta based on synchrotron X-ray diffraction (up to 16 GPa) and ^57Fe Mossb... We report here high-pressure investigations on Piplia Kalan eucrite-a member of HED (Howardite -Eucrite-Diogenite) family from asteroid 4-Vesta based on synchrotron X-ray diffraction (up to 16 GPa) and ^57Fe Mossbauer spectroscopy (up to 8 GPa). Dominant with anorthite-rich plagioclase, pigeonite-rich pyroxene and clino-ferrosilite, the sample displayed various phase transitions attaining amorphous character at 16 GPa. These phase transitions of individual components could be explained simultaneously through variations in high-pressure XRD patterns and the Mossbauer parameters. Most prominent P21/c to C2/c transition of pigeonite and ferrosilite was exhibited both as sudden variation in Mossbauer parameters and population inversion of Fe^2+ in M1 and M2 sites between 2.9 and 3.8 GPa and variation in intensity profile in XRD patterns at 3.56 GPa. Anorthite seemed to respond more to such impact than other components in the sample. Complete amorphization in anorthite which occurred at lower pressure of - 12 GPa implied residual stress experienced due to shock impact. The presence of high pressure (monoclinic) phase of pigeonite and ferrosilite at ambient condition in this eucrite sample confirmed earlier suggestions of an early shock event. This report is an attempt to emphasize the role of anorthite in the determination of the residual stress due to impact process in the parent body thus to understand the behavioral differences amongst HED members. 展开更多
关键词 METEORITES High pressure x-ray diffraction Mossbauer spectroscopy Eucrites synchrotron radiation Ferrosilite
下载PDF
High resolution X-ray diffraction investigation of epitaxially grown SrTiO_3 thin films by laser-MBE
11
作者 翟章印 吴小山 贾全杰 《Chinese Physics C》 SCIE CAS CSCD 2009年第11期949-953,共5页
SrTiO3 thin films are epitaxially grown on DyScO3, LaAlO3 substrates with/without buffer layers of DyScO3 and SrRuO3 using laser-MBE. X-ray diffraction methods, such as high resolution X-ray diffraction, grazing incid... SrTiO3 thin films are epitaxially grown on DyScO3, LaAlO3 substrates with/without buffer layers of DyScO3 and SrRuO3 using laser-MBE. X-ray diffraction methods, such as high resolution X-ray diffraction, grazing incident X-ray diffraction, and reciprocal space mapping are used to investigate the lattice structure, dislocation density, in-plane lattice strain distribution along film thickness. From the measurement results, the effects of substrate on film lattice quality and microstructure are discussed. 展开更多
关键词 laser-MBE grazing incident x-ray diffraction reciprocal space mapping
原文传递
Investigation of Changes in the Fine Structure of Graphitizing Carbon Materials during Heat Treatment by X-Ray Diffraction Analysis
12
作者 Vasiliy A. Tyumentsev Alfiya G. Fazlitdinova 《Journal of Materials Science and Chemical Engineering》 2020年第10期11-20,共10页
The properties of synthetic graphite materials, widely used in advanced fields, are determined by their structure, which is formed in the process of high-temperature (~2500<span style="white-space:normal;"... The properties of synthetic graphite materials, widely used in advanced fields, are determined by their structure, which is formed in the process of high-temperature (~2500<span style="white-space:normal;"><span style="white-space:nowrap;">&#176;</span></span><span style="white-space:normal;"></span>C) heat treatment. The fine structure of a graphitizing carbon material based on petroleum coke containing 1.3 wt% S at various stages of graphitization was studied by X-ray diffraction analysis. Some of the samples contained the addition of dispersed Fe<sub>2</sub>O<sub>3</sub>. It is shown that the heat-treated material in the range 1200<span style="white-space:normal;"><span style="white-space:nowrap;">&#176;</span></span><span style="white-space:normal;"></span>C - 2600<span style="white-space:normal;"><span style="white-space:nowrap;">&#176;</span></span><span style="white-space:normal;"></span>C is heterogeneous, its component composition is determined by the processing temperature and the presence of Fe<sub>2</sub>O<sub>3</sub> additive. The observed dependence of the component composition on the heat treatment temperature suggests that the process of graphitization of the carbon material, apparently, develops through a number of metastable states. 展开更多
关键词 GRAPHITIZATION x-ray diffraction Analysis MICROSTRUCTURE Coherent Scattering Regions
下载PDF
Tracking the phase transformation and microstructural evolution of Sn anode using operando synchrotron X-ray energy-dispersive diffraction and X-ray tomography 被引量:1
13
作者 Kang Dong Fu Sun +4 位作者 Andre Hilger Paul H.Kamm Markus Osenberg Francisco Garcia-Moreno Ingo Manke 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2023年第1期429-437,I0011,共10页
Tin(Sn)holds great promise as an anode material for next-generation lithium(Li)ion batteries but suffers from massive volume change and poor cycling performance.To clarify the dynamic chemical and microstructural evol... Tin(Sn)holds great promise as an anode material for next-generation lithium(Li)ion batteries but suffers from massive volume change and poor cycling performance.To clarify the dynamic chemical and microstructural evolution of Sn anode during lithiation and delithiation,synchrotron X-ray energydispersive diffraction and X-ray tomography are simultaneously employed during Li/Sn cell operation.The intermediate Li-Sn alloy phases during de/lithiation are identified,and their dynamic phase transformation is unraveled which is further correlated with the volume variation of the Sn at particle-and electrode-level.Moreover,we find that the Sn particle expansion/shrinkage induced particle displacement is anisotropic:the displacement perpendicular to the electrode surface(z-axis)is more pronounced compared to the directions(x-and y-axis)along the electrode surface.This anisotropic particle displacement leads to an anisotropic volume variation at the electrode level and eventually generates a net electrode expansion towards the separator after cycling,which could be one of the root causes of mechanical detachment and delamination of electrodes during long-term operation.The unraveled chemical evolution of Li-Sn and deep insights into the microstructural evolution of Sn anode provided here could guide future design and engineering of Sn and other alloy anodes for high energy density Li-and Na-ion batteries. 展开更多
关键词 Sn anode Li-Sn phase transformation x-ray tomography Operando x-ray diffraction Anisotropic displacement Digital volume correlation(DVC)
下载PDF
Thermal expansivity of geikielite and ilmenite utilizing in-situ synchrotron X-ray diffraction at high temperature
14
作者 Jiamei Song Dawei Fan +4 位作者 Shijie Huang Shanrong Zhang Mengzeng Wu Wei Chen Wenge Zhou 《Acta Geochimica》 EI CAS CSCD 2023年第6期988-997,共10页
The unit-cell parameters and volumes of geikielite(MgTiO_(3))and ilmenite(FeTiO_(3))were investigated at high temperatures up to 700 K and ambient pressure,using in-situ angle-dispersive synchrotron X-ray diffraction.... The unit-cell parameters and volumes of geikielite(MgTiO_(3))and ilmenite(FeTiO_(3))were investigated at high temperatures up to 700 K and ambient pressure,using in-situ angle-dispersive synchrotron X-ray diffraction.No phase transition was detected over the experimental temperature range.Using(Berman in J Petrol29:445-522,1988.10.1093/petrology/29.2.445)equations to fit the temperature-volume data,the volumetric thermal expansion coefficients at ambient conditions(α_(V0))of MgTiO_(3) and FeTiO_(3) were obtained as follows:2.55(6)×10^(-5)K^(-1)and 2.82(10)×10^(-5)K^(-1),respectively.We infer that the larger effective ionic radius of Fe^(2+)(Ⅵ)(0.78 A)than that of Mg^(2+)(Ⅵ)(0.72?)renders FeTiO_(3)has a larger volumetric thermal expansivity than MgTiO_(3).Simultaneously,the refined axial thermal expansion coefficients under ambient conditions areα_(a0)=0.74(3)×10^(-5)K^(-1)andα_(c0)=1.08(5)×10^(-5)K^(-1)for the aaxis and c-axis of MgTiO_(3),respectively,andα_(a0)=0.95(5)×10^(-5)K^(-1)andα_(c0)=0.92(12)×10^(-5)K^(-1)for the aaxis and c-axis of FeTiO_(3),respectively.The axial thermal expansivity of MgTiO_(3) is anisotropic,but that of FeTiO_(3) is nearly isotropic.We infer that the main reason for the different axial thermal expansivity between MgTiO_(3) and FeTiO_(3) is that the thermal expansion mode of the Mg-O bond in MgTiO_(3) is different from that of the Fe-O bonds in FeTiO_(3). 展开更多
关键词 Geikielite ILMENITE Thermal expansion Synchrotron x-ray diffraction High temperature
下载PDF
Elastic modulus of TiN film investigated with Kroner model and X-ray diffraction 被引量:1
15
作者 张铭 孙海林 何家文 《中国有色金属学会会刊:英文版》 CSCD 2001年第1期63-66,共4页
The four point bending method was applied to measure X ray elastic constants(XEC) of (422) and (331) planes of TiN coating. Elastic Modulus and XECs of all the crystal planes were calculated by Kroner method. The resu... The four point bending method was applied to measure X ray elastic constants(XEC) of (422) and (331) planes of TiN coating. Elastic Modulus and XECs of all the crystal planes were calculated by Kroner method. The results from the calculation and the experiment were compared. It is concluded that the XECs values of same film prepared by different techniques scatter a little because of the effects of stoichiometric proportion and microstructure of films. [ 展开更多
关键词 ELASTIC CONSTANTS four-point BENDING x-ray diffraction titanium NITRIDE
下载PDF
Evaluation on residual stresses of silicon-doped CVD diamond films using X-ray diffraction and Raman spectroscopy 被引量:10
16
作者 陈苏琳 沈彬 +2 位作者 张建国 王亮 孙方宏 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2012年第12期3021-3026,共6页
The effect of silicon doping on the residual stress of CVD diamond films is examined using both X-ray diffraction (XRD) analysis and Raman spectroscopy measurements. The examined Si-doped diamond films are deposited o... The effect of silicon doping on the residual stress of CVD diamond films is examined using both X-ray diffraction (XRD) analysis and Raman spectroscopy measurements. The examined Si-doped diamond films are deposited on WC-Co substrates in a home-made bias-enhanced HFCVD apparatus. Ethyl silicate (Si(OC2H5)4) is dissolved in acetone to obtain various Si/C mole ratio ranging from 0.1% to 1.4% in the reaction gas. Characterizations with SEM and XRD indicate increasing silicon concentration may result in grain size decreasing and diamond [110] texture becoming dominant. The residual stress values of as-deposited Si-doped diamond films are evaluated by both sin2ψ method, which measures the (220) diamond Bragg diffraction peaks using XRD, with ψ-values ranging from 0° to 45°, and Raman spectroscopy, which detects the diamond Raman peak shift from the natural diamond line at 1332 cm-1. The residual stress evolution on the silicon doping level estimated from the above two methods presents rather good agreements, exhibiting that all deposited Si-doped diamond films present compressive stress and the sample with Si/C mole ratio of 0.1% possesses the largest residual stress of ~1.75 GPa (Raman) or ~2.3 GPa (XRD). As the silicon doping level is up further, the residual stress reduces to a relative stable value around 1.3 GPa. 展开更多
关键词 silicon-doped diamond films silicon doping residual stress x-ray diffraction Raman spectroscopy
下载PDF
Thermal expansion of kyanite at ambient pressure:An X-ray powder diffraction study up to 1000℃ 被引量:11
17
作者 Xi Liu Qiang He +2 位作者 Hejing Wang Michael E. Fleet Xiaomin Hu 《Geoscience Frontiers》 SCIE CAS 2010年第1期91-97,共7页
The thermal expansion coefficients of kyanite at ambient pressure have been investigated by an X-ray powder diffraction technique with temperatures up to 1000 ℃. No phase transition was observed in the experimental t... The thermal expansion coefficients of kyanite at ambient pressure have been investigated by an X-ray powder diffraction technique with temperatures up to 1000 ℃. No phase transition was observed in the experimental temperature range. Data for the unit-cell parameters and temperatures were fitted empirically resulting in the following thermal expansion coefficients: αa = 5.8(3) × 10^-5, αb = 5.8 (1)× 10^-5, αc = 5.2(1)× 10^-5, and αv = 7.4(1) × 10^-3 ℃ 1 in good agreement with a recent neutron powder diffraction study. On the other hand, the variation of the unit-cell angles α, β and γ of kyanite with increase in temperature is very complicated, and the agreement among all studies is poor. The thermal expansion data at ambient pressure reported here and the compression data at ambient temperature from the literature suggest that, for the kyanite lattice, the most and least thermally expandable directions correspond to the most and least compressible directions, respectively. 展开更多
关键词 High temperature KYANITE Thermal expansion x-ray powder diffraction
下载PDF
SnO_2-based solid solutions for CH_4 deep oxidation: Quantifying the lattice capacity of SnO_2 using an X-ray diffraction extrapolation method
18
作者 孙琪 徐香兰 +5 位作者 彭洪根 方修忠 刘文明 应家伟 余帆 王翔 《Chinese Journal of Catalysis》 SCIE EI CAS CSCD 北大核心 2016年第8期1293-1302,共10页
A series of SnO2‐based catalysts modified by Mn, Zr, Ti and Pb oxides with a Sn/M (M=Mn, Zr, Ti and Pb) molar ratio of 9/1 were prepared by a co‐precipitation method and used for CH4 and CO oxidation. The Mn3+, ... A series of SnO2‐based catalysts modified by Mn, Zr, Ti and Pb oxides with a Sn/M (M=Mn, Zr, Ti and Pb) molar ratio of 9/1 were prepared by a co‐precipitation method and used for CH4 and CO oxidation. The Mn3+, Zr4+, Ti4+and Pb4+cations are incorporated into the lattice of tetragonal rutile SnO2 to form a solid solution structure. As a consequence, the surface area and thermal stability of the catalysts are improved. Moreover, the oxygen species of the modified catalysts become easier to be reduced. Therefore, the oxidation activity over the catalysts was improved, except for the one modified by Pb oxide. Manganese oxide demonstrates the best promotional effects for SnO2. Using an X‐ray diffraction extrapolation method, the lattice capacity of SnO2 for Mn2O3 was 0.135 g Mn2O3/g SnO2, which indicates that to form stable solid solution, only 21%Sn4+cations in the lattice can be maximally replaced by Mn3+. If the amount of Mn3+cations is over the capacity, Mn2O3 will be formed, which is not favorable for the activity of the catalysts. The Sn rich samples with only Sn‐Mn solid solution phase show higher activity than the ones with excess Mn2O3 species. 展开更多
关键词 SnO2-based solid solution x-ray diffraction extrapolation method Lattice capacity Methane deep oxidation Carbon monoxide oxidation
下载PDF
X-ray Diffraction of Dust Particles in Spring Beijing 被引量:5
19
作者 ZHENG Nan WANG Hejin +1 位作者 XU Tingjing LI Ting 《Acta Geologica Sinica(English Edition)》 SCIE CAS CSCD 2011年第1期254-262,共9页
X-ray diffractometry was utilized to study the mineralogical characteristics of the inhalable particles (PM10) sampled during two dust storms in Beijing city on March 18th and May 21st, 2008. We confirm, for the fir... X-ray diffractometry was utilized to study the mineralogical characteristics of the inhalable particles (PM10) sampled during two dust storms in Beijing city on March 18th and May 21st, 2008. We confirm, for the first time, that there stably exists ammonium chloride in the atmosphere when temperature is low. The total sulfates particles were affected by relative humidity. Both species and concentration of sulfates decreased first and then grew back by the end of each dust storm. Koninckite, a phosphate mineral never reported as particulate aerosol before, was identified. Meanwhile, our result shows that a chemical modification on dust minerals occurs during long range transportation. PM10 samples collected during the period of dust storms were dominated by crustal minerals such as quartz, illite/smectite, illite, chlorite, feldspar and calcite, and were notably higher in concentration than that in normal periods of time. The amounts of total sulfates, calcite and feldspar altered in each dust storm. It is derived from 24-hour isentropic backward trajectories that two dust events in spring 2008 originated in different sources. 展开更多
关键词 dust storm PM10 x-ray diffraction ammonium chloride
下载PDF
MULTI-PEAK MATCH INTENSITY RATIO METHOD OF QUANTI-TATIVE X-RAY DIFFRACTION PHASE ANALYSIS 被引量:5
20
作者 G. Chu, Y.F. Cong and H.J. YouResearch Center of Analysis and Test, Liaoning University of Petroleum & Chemical Technology, Fushun 113001, China 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 2003年第6期489-494,共6页
A new method for quantitative phase analysis is proposed by using X-ray diffraction multi-peak match intensity ratio. This method can obtain the multi-peak match intensity ratio among each phase in the mixture sample ... A new method for quantitative phase analysis is proposed by using X-ray diffraction multi-peak match intensity ratio. This method can obtain the multi-peak match intensity ratio among each phase in the mixture sample by using all diffraction peak data in the mixture sample X-ray diffraction spectrum and combining the relative intensity distribution data of each phase standard peak in JCPDS card to carry on the least square method regression analysis. It is benefit to improve the precision of quantitative phase analysis that the given single line ratio which is usually adopted is taken the place of the multi-peak match intensity ratio and is used in X-ray diffraction quantitative phase analysis of the mixture sample. By analyzing four-group mixture sample, adopting multi-peak match intensity ratio and X-ray diffraction quantitative phase analysis principle of combining the adiabatic and matrix flushing method, it is tested that the experimental results are identical with theory. 展开更多
关键词 x-ray diffraction multi-peak match intensity ratio quantitative phase analysis
下载PDF
上一页 1 2 60 下一页 到第
使用帮助 返回顶部