Evaluation of Air-Kerma and Absorbed Dose to Water for External Radiotherapy Beam Using Ionization Chamber
1
作者 Collins Omondi Margaret Chege Samson Omondi 《Open Journal of Radiology》 2024年第3期113-124,共12页
Radiotherapy is the most widely applied oncologic treatment modality utilizing ionizing radiation. A high degree of accuracy, reliability and reproducibility is required for a successful treatment outcome. Measurement... Radiotherapy is the most widely applied oncologic treatment modality utilizing ionizing radiation. A high degree of accuracy, reliability and reproducibility is required for a successful treatment outcome. Measurement using ionization chamber is a prerequisite for absorbed dose determination for external beam radiotherapy. Calibration coefficient is expressed in terms of air kerma and absorbed dose to water traceable to Secondary Standards Dosimetry Laboratory. The objective of this work was to evaluate the level of accuracy of ionization chamber used for clinical radiotherapy beam determination. Measurement and accuracy determination were carried out according to IAEA TRS 398 protocol. Clinical farmers type ionization chamber measurement and National Reference standard from Secondary Standards Dosimetry Laboratory were both exposed to cobalt-60 beam and measurement results compared under the same environmental conditions. The accuracy level between National Reference Standard and clinical radiotherapy standard was found to be −1.92% and −2.02% for air kerma and absorbed dose to water respectively. To minimize the effect of error and maximize therapeutic dose during treatment in order to achieve required clinical outcome, calibration factor was determined for air kerma (Nk) as 49.7 mGy/nC and absorbed dose to water ND, as 52.9 mGy/nC. The study established that radiotherapy beam measurement chain is prone to errors. Hence there is a need to independently verify the accuracy of radiation dose to ensure precision of dose delivery. The errors must be accounted for during clinical planning by factoring in calibration factor to minimize the systematic errors during treatment, and thereby providing enough room to achieve ±5% dose delivery to tumor target as recommended by ICRU. 展开更多
关键词 absorbed dose to Water Air Kerma Co-60 Source Calibration SSDL Radiotherapy Beam METROLOGY Accuracy and Accuracy
下载PDF
Fast neutron radiation inactivation of Bacillus subtilis:Absorbed dose determination 被引量:3
2
作者 SONG Lingli ZHENG Chun AI Zihui LI Junjie DAI Shaofeng 《Nuclear Science and Techniques》 SCIE CAS CSCD 2011年第3期156-159,共4页
In this paper,fast neutron inactivation effects of Bacillus subtilis were investigated with fission fast neutrons from CFBR-Ⅱreactor of INPC(Institute of Nuclear Physics and Chemistry)and mono-energetic neutrons from... In this paper,fast neutron inactivation effects of Bacillus subtilis were investigated with fission fast neutrons from CFBR-Ⅱreactor of INPC(Institute of Nuclear Physics and Chemistry)and mono-energetic neutrons from the Van de Graaff accelerator at Peking University.The method for determining the absorbed dose in the Bacillus subtilis suspension contained in test tubes is introduced.The absorbed dose,on account of its dependence on the volume and the form of confined state,was determined by combined experiments and Monte Carlo method.Using the calculation results of absorbed dose,the fast neutron inactivation effects on Bacillus subtilis were studied.The survival rates and absorbed dose curve was constructed. 展开更多
关键词 枯草芽孢杆菌 吸收剂量 中子辐射 测定 失活 蒙特卡罗方法 灭活效果 化学研究所
下载PDF
Evaluation of Entrance Skin Dose from Paediatric Diagnostic X-Ray Examination
3
作者 Moromoke Oluwayemisi Adelayi Oladele Samuel Ajayi 《Open Journal of Radiology》 2023年第1期26-33,共8页
As children are prone to be more radiosensitive than adults, it is imperative to assess the Entrance Skin Doses (ESDs) for patients being examined by X-rays, in order to ensure the optimization of dose while consideri... As children are prone to be more radiosensitive than adults, it is imperative to assess the Entrance Skin Doses (ESDs) for patients being examined by X-rays, in order to ensure the optimization of dose while considering a number of other fickles. The ESD received by 50 paediatrics (aged 1-13 years) undergoing 8 types of X-ray examinations were measured at Federal Teaching Hospital, Ido-Ekiti, Ekiti, Nigeria, within a period of February 2019 to March 2020 using thermoluminescent dosimeters. The mean ± SD of ESDs were 0.85 ± 0.32, 2.04 ± 0.75, 0.60 ± 0.07, 0.62 ± 0.22, 0.57 ± 0.24, 1.75 ± 0.76, 0.93 ± 0.31 and 0.63 ± 0.06 mGy for Chest, Skull, Hand, Forearm, Knee, Abdomen, Leg and Feet, respectively. The mean ESDs were found to be within the recommended reference dose in all examinations, except for the Chest examination which was higher. The data obtained in this study will serve as existing data in Nigeria for future research works, as it would assist in optimizing dose to patients, especially the paediatrics. 展开更多
关键词 Entrance Skin dose PAEDIATRICS x-rays
下载PDF
Establishment of NaLuF_(4):15%Tb-based low dose X-PDT agent and its application on efficient antitumor therapy
4
作者 Yi Tian Zhiguang Fu +7 位作者 Xiaosheng Zhu Chunjing Zhan Jinwei Hu Li Fan Chaojun Song Qian Yang Yu Wang Mei Shi 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2024年第3期599-610,共12页
X-ray excited photodynamic therapy(X-PDT)is the bravo answer of photodynamic therapy(PDT)for deep-seated tumors,as it employs X-ray as the irradiation source to overcome the limitation of light penetration depth.Howev... X-ray excited photodynamic therapy(X-PDT)is the bravo answer of photodynamic therapy(PDT)for deep-seated tumors,as it employs X-ray as the irradiation source to overcome the limitation of light penetration depth.However,high X-ray irradiation dose caused organ lesions and side effects became the major barrier to X-PDT application.To address this issue,this work employed a classic-al co-precipitation reaction to synthesize NaLuF_(4):15%Tb^(3+)(NLF)with an average particle size of(23.48±0.91)nm,which was then coupled with the photosensitizer merocyanine 540(MC540)to form the X-PDT system NLF-MC540 with high production of singlet oxygen.The system could induce antitumor efficacy to about 24%in relative low dose X-ray irradiation range(0.1-0.3 Gy).In vivo,when NLF-MC540 irradiated by 0.1 Gy X-ray,the tumor inhibition percentage reached 89.5%±5.7%.The therapeutic mechanism of low dose X-PDT was found.A significant increase of neutrophils in serum was found on the third day after X-PDT.By immunohistochemical staining of tumor sections,the Ly6G^(+),CD8^(+),and CD11c^(+)cells infiltrated in the tumor microenvironment were studied.Utilizing the bilat-eral tumor model,the NLF-MC540 with 0.1 Gy X-ray irradiation could inhibit both the primary tumor and the distant tumor growth.De-tected by enzyme linked immunosorbent assay(ELISA),two cytokines IFN-γand TNF-αin serum were upregulated 7 and 6 times than negative control,respectively.Detected by enzyme linked immune spot assay(ELISPOT),the number of immune cells attributable to the IFN-γand TNF-αlevels in the group of low dose X-PDT were 14 and 6 times greater than that in the negative control group,respectively.Thus,it conclude that low dose X-PDT system could successfully upregulate the levels of immune cells,stimulate the secretion of cy-tokines(especially IFN-γand TNF-α),activate antitumor immunity,and finally inhibit colon tumor growth. 展开更多
关键词 x-ray excited photodynamic therapy singlet oxygen low dose x-ray irradiation efficient antitumor therapy anti-tumor immunity
下载PDF
The Effect of the Size of Radiotherapy Photon Beams on the Absorbed Dose to an Al_2O_3 Dosimeter
5
作者 陈少文 张文澜 +2 位作者 范丽仙 唐强 刘小伟 《Plasma Science and Technology》 SCIE EI CAS CSCD 2012年第6期558-562,共5页
The effect of the size of radiotherapy photon beams on the absorbed dose to an Al2O3 dosimeter was investigated using the Monte Carlo method. The EGSnrc/DOSRZnrc program code was used to simulate the absorbed dose to ... The effect of the size of radiotherapy photon beams on the absorbed dose to an Al2O3 dosimeter was investigated using the Monte Carlo method. The EGSnrc/DOSRZnrc program code was used to simulate the absorbed dose to the Al2O3 dosimeter, as well as the absorbed dose to water at the corresponding position in the absence of the dosimeter. The incident beams were 60Co γ and 6 MV with a different beam radius ranging from 0.1 cm to 2 cm. Results revealed that the absorbed dose ratio factor depends on the size of the incident photon beam. When the radius of the incident beam is smaller than that of the dosimeter, the absorbed dose ratio factor decreases as the incident beam size increases. The absorbed dose ratio factor reaches its minimum when the radius of the incident beam is almost the same as that of the dosimeter. When the radius of the incident beam is larger than that of the dosimeter, the absorbed dose ratio factor increases as the incident beam size increases. The maximum difference among these absorbed dose ratio factors can be up to 14% in 60Co γ beams and 23% in 6 MV beams. However, when the size of the incident beam is much larger than that of the dosimeter, the effect of the incident beam size on the absorbed dose ratio factor becomes quite small. The maximum discrepancy between the absorbed dose ratio factors and the average value is not more than 1%. 展开更多
关键词 Al2O3 dosimeter absorbed dose Monte Carlo radiotherapy photon beams
下载PDF
DETERMINATION OF SUPERFICAL ABSORBED DOSE FROMEXTERNAL EXPOSURE OF WEAKLY PENETRATING RADEATIONS
6
作者 陈丽姝 《Nuclear Science and Techniques》 SCIE CAS CSCD 1994年第1期29-34,共6页
The methods of determining the superficial absorbed dose distributions in a water phantom by means of the experiments and available theories have been reported. The distributions of beta dose were measured by an extra... The methods of determining the superficial absorbed dose distributions in a water phantom by means of the experiments and available theories have been reported. The distributions of beta dose were measured by an extrapolation ionization chamber at definite depthes corresponding to some superficial organs and tissues such as the radiosensitive layer of the skin, cornea, sclera, anterior chamber and lens of eyeball.The ratios among superficial absorbed dose D (0.07) and average absorbed doses at the depthes 1,2,3,4,5 and 6 mm are also obtained with Cross's methods. They can be used for confining the deterministic effects of some superficial tissues and organs such as the skin and the components of eyeball for weakly penetrating radiations. 展开更多
关键词 Water phantom Superficial absorbed dose EYES dose limits Weakly penetrating radiations Safety standards Extrapolation chamber Skin dose
下载PDF
Ensuring Uniformity of Measurements of Absorbed Doses of Intensive Photon and Electron Radiation in Radiation Technologies
7
作者 V. V. Generalova A. A. Gromov O. I. Kovalenko 《Journal of Applied Mathematics and Physics》 2015年第8期942-946,共5页
Ensuring reliability and traceability of the unit of absorbed dose of intense photon and electron radiation, used in radiation technologies in industry, is based on the creation of a system of sample measures and meth... Ensuring reliability and traceability of the unit of absorbed dose of intense photon and electron radiation, used in radiation technologies in industry, is based on the creation of a system of sample measures and methods of transmission with minimal loss of dimensional accuracy of the unit of absorbed dose from the sample tools to working dosimeters and is a necessary basis of yield growth, of increase of labour productivity and the introduction of innovative products. The measuring capabilities of the State primary special standard of power unit of absorbed dose of intensity photon, electron and beta radiation for radiation technologies and of the standards of the absorbed dose of photon and electron radiation, used for radiation monitoring of radiation pro- cesses. 展开更多
关键词 RADIATION Technology absorbed dose Ensuring UNIFORMITY of MEASUREMENTS Certified Reference Material
下载PDF
Evaluation of Dosimetric Impact of Uncertainty of Measurement in Estimating External Radiotherapy Dose
8
作者 Collins Omondi Margaret Chege Samson Omondi 《Open Journal of Applied Sciences》 2024年第8期1985-1995,共11页
Cancer is a major societal public health and economic problem, responsible for one in every six deaths. Radiotherapy is the main technique of treatment for more than half of cancer patients. To achieve a successful ou... Cancer is a major societal public health and economic problem, responsible for one in every six deaths. Radiotherapy is the main technique of treatment for more than half of cancer patients. To achieve a successful outcome, the radiation dose must be delivered accurately and precisely to the tumor, within ± 5% accuracy. Smaller uncertainties are required for better treatment outcome. The objective of the study is to investigate the uncertainty of measurement of external radiotherapy beam using a standard ionization chamber under reference conditions. Clinical farmers type ionization chamber measurement was compared against the National Reference standard, by exposing it in a beam 60Co gamma source. The measurement set up was carried out according to IAEA TRS 498 protocol and uncertainty of measurement evaluated according to GUM TEDDOC-1585. Evaluation and analysis were done for the identified subjects of uncertainty contributors. The expanded uncertainty associated with 56 mGy/nC ND,W was found to be 0.9% corresponding to a confidence level of approximately 95% with a coverage factor of k = 2. The study established the impact of dosimetry uncertainty of measurement in estimating external radiotherapy dose. The investigation established that the largest contributor of uncertainty is the stability of the ionization chamber at 36%, followed by temperature at 22% and positioning of the chamber in the beam at 8%. The effect of pressure, electrometer, resolution, and reproducibility were found to be minimal to the overall uncertainty. The study indicate that there is no flawless measurement, as there are many prospective sources of variation. Measurement results have component of unreliability and should be regarded as best estimates of the true value. . 展开更多
关键词 absorbed dose to Water RADIOTHERAPY Uncertainty of Measurement Secondary Standards Dosimetry Laboratory Ionizing Chamber
下载PDF
Absorbed Dose to Water Rate in a Cyberknife VSI System Reference Field Using Ionization Chambers and Gafchromic Films
9
作者 Guerda Massillon-JL Nestor Aragó +4 位作者 n-Martí nez Arnulfo Gó mez-Muñ oz 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2017年第1期80-92,共13页
This work investigated the absorbed dose to water rate under reference conditions in a Cyberknife VSI system using radiochromic films EBT3 and MD-V3 and three ionization chambers: an Exradin A12 and two FC65P Welh&... This work investigated the absorbed dose to water rate under reference conditions in a Cyberknife VSI system using radiochromic films EBT3 and MD-V3 and three ionization chambers: an Exradin A12 and two FC65P Welh&ouml;fer Scanditronix with different serial numbers. The correction factor,, was studied using a Varian iX linac and the Cyberknife system. The measurements in the Varian iX were performed in a 10 × 10 cm2 field, 10 cm depth in liquid water at 90 cm and 70 cm SSD and in a 5.4 × 5.4 cm2 field, 10 cm depth at 70 cm SSD to simulate the Cyberknife conditions. In the Cyberknife system, measurements were performed using ionization chambers and both film types at 70 cm SSD and 10 cm depth in its 6 cm diameter reference field. The results indicate that ?is independent of the dosimeters and the evaluation methods. Maximum differences of 0.22% - 0.55% (combined uncertainties of 1.22% - 1.98%, k = 1) are obtained on ?using Varian iX, whereas discrepancies of 2.08% - 2.09% (combined uncertainties of 1.87% - 2.13%, k = 1) are observed using the Cyberknife system. Given the agreement between detectors and the combined standard uncertainties, the data from Varian iX could be considered the most accurate and consequently a weighted average factor of 0.902 ± 0.006 could be used for the Cyberknife VSI system reference field. Within measurement uncertainties, the absorbed dose rate measured in the Cyberknife VSI system reference field was found to be independent of the dosimeters used. These results suggest that the absorbed dose measured at a point within a given field size should be the same, regardless the dosimeter used, if their dosimetric characteristics are well known. This highlighted the importance of performing dosimetry by controlling all parameters that could affect the dosimeter response. One can conclude that radiochromic film dosimetry can be considered as an appropriate alternative for measuring absorbed dose to water rate. 展开更多
关键词 Small FIELD DOSIMETRY Reference FIELD CYBERKNIFE Gafchromic Films Ionization CHAMBERS dose RATE EBT3 MD-V3 6 MV x-rays
下载PDF
International Recommendations on Calculation of Absorbed Dose in Biota:A Comprehensive Revue
10
作者 Wagner de S.Pereira Alphonse Kelecom 《Journal of Environmental Protection》 2014年第9期751-759,共9页
Since the early times, radioprotection has been focused on the human being. Currently this approach has changed, being now also necessary to take care of the protection of the environment from unwanted effects of ioni... Since the early times, radioprotection has been focused on the human being. Currently this approach has changed, being now also necessary to take care of the protection of the environment from unwanted effects of ionizing radiation. To this end, several institutions (UNSCEAR, ICRP, IAEA, DOE, ACRP) and consortia of institutions (FASSET, ERICA) have established procedures in order to protect the biota of such effects. Developed procedures are based on the calculation of the absorbed dose in biota (ICRP, DOE, IAEA), or on environmental risk assessment―ERA (DOE, ACRP, FASSET, ERICA);but even in this latter approach the parameters used are related to the absorbed doses in biota. The calculation of dose is the standard procedure in human radioprotection, and this points such an approach as the most interesting for providing a convergence between human and nonhuman (= biota) radioprotections. On the other hand, the ERA approach is easier to apply, because this methodology is used in several countries for non-radioactive contamination assessments. Since the world radioprotection system follows a number of institutions (UNSCEAR, ICRP, IAEA and regulatory institutions of member countries) that use dose calculation, this appears to be the way for biota radioprotection. We here review and comment the evolution of the concepts and approaches of the recommendations for radioprotection of non-human biota. 展开更多
关键词 BIOTA absorbed dose RADIOPROTECTION International Recommendations
下载PDF
XPS study of surface absorbed oxygen of ABO_3 mixed oxides 被引量:9
11
作者 赵馨 杨秋华 崔津津 《Journal of Rare Earths》 SCIE EI CAS CSCD 2008年第4期511-514,共4页
Perovskite-type complex oxides ABO3 (A=Sr, La; B=Mn, Fe, Co) were prepared by citric acid method. The degradation of water-solubilized dyes was carried out using the mixed oxides as photocatalyst. The surface absorb... Perovskite-type complex oxides ABO3 (A=Sr, La; B=Mn, Fe, Co) were prepared by citric acid method. The degradation of water-solubilized dyes was carried out using the mixed oxides as photocatalyst. The surface absorbed oxygen was analyzed using X-ray photoelectron spectroscopy (XPS). The results indicated that there was a relationship between the photocatalytic activity and the content of the surface absorbed oxygen. The higher the content of the surface absorbed oxygen was, the better the performance of the photocatalyst. 展开更多
关键词 PEROVSKITE x-ray photoelectron spectroscopy surface absorbed oxygen PHOTOCATALYSIS rare earths
下载PDF
Radiation Doses in Diagnostic Radiology and Method for Dose Reduction
12
作者 Taha M. Taha Hoda A. Ahmed Fathy A. Shaheen 《Open Journal of Radiology》 2023年第1期34-41,共8页
Objective: The current research study aims to calculate entrance surface air kerma for skull, chest, cervical spine, lumbar spine, and pelvic X-ray examinations in interior posterior and posterior interior positions a... Objective: The current research study aims to calculate entrance surface air kerma for skull, chest, cervical spine, lumbar spine, and pelvic X-ray examinations in interior posterior and posterior interior positions and generate a method for chest dose reduction to decrease radiation risk. Materials and Methods: The indirect dose measurement was used in the current research. The X-ray tube output was measured using RAD-CHECK Plus ionization chamber and the indirect entrance surface air kerma was calculated via applying physical acquisition parameters such as a focus on skin distance, tube current times exposure time (mAs), and applied tube voltage (kV), and applying a mathematical model. Results: The main findings were obtained from comparing the radiation doses with the reference levels of International organizations such as the American College of Radiology and the International Atomic Energy Authority. The mean entrance skin dose for the skull (AP), skull (PA), skull (LAT), cervical spine (PA), cervical spine (LAT), lumbar spine (AP), lumbar spine (LAT), pelvis (AP), and pelvis (LAT) of adult X-ray examinations was within the diagnostic reference dose level values obtained by ACR (2018) except for the ESD for chest (AP) which was 0.88 mGy. Conclusions: The results of the study concluded that by adjusting the applied tube voltage, kV, and tube current product time, mAs decreased the radiation dose to the chest X-ray by 58%. 展开更多
关键词 RADIOLOGY Entrance Skin dose Chest x-ray dose Minimization
下载PDF
水量热法^(60)Coγ射线水吸收剂量的绝对测量
13
作者 杨乾 范杰 许诗朦 《核技术》 EI CAS CSCD 北大核心 2024年第7期25-31,共7页
目前国内大多数放射治疗剂量只能溯源到^(60)Co γ射线空气比释动能,与溯源至空气比释动能相比,将放射治疗剂量直接溯源至水吸收剂量的不确定度要小很多。为了解决^(60)Co γ射线水吸收剂量量值溯源与传递问题,进一步提升^(60)Co γ射... 目前国内大多数放射治疗剂量只能溯源到^(60)Co γ射线空气比释动能,与溯源至空气比释动能相比,将放射治疗剂量直接溯源至水吸收剂量的不确定度要小很多。为了解决^(60)Co γ射线水吸收剂量量值溯源与传递问题,进一步提升^(60)Co γ射线水吸收剂量的量值溯源与传递能力,中国测试技术研究院(National Institute of Measurement and Testing Technology,NIMTT)采用水量热法建立了^(60)Co γ射线水吸收剂量绝对测量装置,实现了水吸收剂量的绝对测量,复现了^(60)Co γ射线水吸收剂量,其量值复现的相对标准不确定度为0.45%。为了进一步验证^(60)Co γ射线水吸收剂量复现结果的准确性与一致性,将NIMTT实验室与加拿大国家研究委员会(National Research Council,NRC)实验室的复现结果进行了实验室之间的比对,结果在相对标准不确定度0.71%以内呈现一致性,归一化误差En值为-0.45。表明NIMTT具有^(60)Co γ射线水吸收剂量量值溯源与传递的能力,本研究结果也为^(60)Co γ射线吸收剂量的绝对测量提供了参考。 展开更多
关键词 水量热法 水吸收剂量 电离辐射 绝对测量
下载PDF
双重血浆分子吸附联合低剂量血浆置换治疗肝衰竭高胆红素患者的疗效研究
14
作者 陈佳炜 蔡毅峰 +1 位作者 章志坚 翁冬锐 《中外医疗》 2024年第11期9-12,共4页
目的探究双重血浆分子吸附(Double Plasma Molecular Absorb System,DPMAS)联合低剂量血浆置换(Plasma Exchange,PE)治疗肝衰竭高胆红素患者的疗效。方法简单随机选取2021年3月—2023年3月潮州市中心医院收治的50例肝衰竭高胆红素患者... 目的探究双重血浆分子吸附(Double Plasma Molecular Absorb System,DPMAS)联合低剂量血浆置换(Plasma Exchange,PE)治疗肝衰竭高胆红素患者的疗效。方法简单随机选取2021年3月—2023年3月潮州市中心医院收治的50例肝衰竭高胆红素患者作为研究对象,采用简单随机化法将其分为DPMAS+PE组(n=25)和PE组(n=25)。观察两组疗效、肝功能、血常规指标与凝血功能。结果DPMAS+PE组总有效率(96.00%)高于PE组(72.00%),差异有统计学意义(P<0.05);DPMAS+PE组谷草转氨酶、总胆红素以及谷丙转氨酶低于PE组,差异有统计学意义(P均<0.05);DPMAS+PE组活化部分凝血酶原时间、凝血酶原活动度优于PE组,差异有统计学意义(P均<0.05)。治疗后两组血红蛋白、血小板计数、白细胞比较,差异无统计学意义(P均>0.05)。结论DPMAS+PE可有效提高在肝衰竭高胆红素患者中的疗效,改善患者的肝功能及凝血功能指标。 展开更多
关键词 双重血浆分子吸附 低剂量血浆置换 肝衰竭 高胆红素 疗效
下载PDF
光子吸收剂量的蒙特卡罗计算方法研究
15
作者 谢蓉 郝建红 +5 位作者 赵强 张芳 范杰清 薛碧曦 董志伟 曹相春 《强激光与粒子束》 CAS CSCD 北大核心 2024年第10期150-157,共8页
为了能够通过选择合适的计算方法对不同辐射情况的光子剂量进行准确有效的计算和评估,对比研究了蒙特卡罗模拟软件中常用的四种光子剂量计算方法:剂量转换系数法、发热数法、径迹长度能量沉积法和脉冲高度计数法,从计算原理出发结合仿... 为了能够通过选择合适的计算方法对不同辐射情况的光子剂量进行准确有效的计算和评估,对比研究了蒙特卡罗模拟软件中常用的四种光子剂量计算方法:剂量转换系数法、发热数法、径迹长度能量沉积法和脉冲高度计数法,从计算原理出发结合仿真结果分析比较了这四种方法。通过模拟不同能量的单能光子束入射不同体积大小的水球,分析了用比释动能近似吸收剂量导致的误差,并且模拟分析了不同含量的高原子序数元素钆对于吸收剂量计算结果差异的影响。由于转换系数是根据参考人模计算得到的,因此剂量转换系数法只能对吸收剂量进行快速的估计计算,很难在特定情况下得到精准剂量;当高能量光子入射小体积物质时,比释动能会大于吸收剂量,使用发热数法和径迹长度能量沉积法会产生误差,采用脉冲高度计数法更加合适;在低能量和大体积时可以根据计算精度和计算机资源选择任意方法;当组成物质的高原子序数元素含量增多时,径迹长度能量沉积法和脉冲高度计数法之间的计算误差会减少。 展开更多
关键词 光子 吸收剂量 蒙特卡罗方法 人体模型模拟计算
下载PDF
多种水等效材料的医用电子束修正因子研究
16
作者 姚金涛 李毅华 +3 位作者 王坤 王志鹏 金孙均 吴晗 《计量学报》 CSCD 北大核心 2024年第5期747-754,共8页
针对水等效材料在医用电子束剂量测量中修正因子的测量和使用问题,通过扫描医用电子束在水中和水等效材料中的百分深度剂量(percentage depth dose,PDD)曲线,计算获得深度缩放因子c_(pl)、注量缩放因子h_(pl)及总修正因子k_(pl)的实验... 针对水等效材料在医用电子束剂量测量中修正因子的测量和使用问题,通过扫描医用电子束在水中和水等效材料中的百分深度剂量(percentage depth dose,PDD)曲线,计算获得深度缩放因子c_(pl)、注量缩放因子h_(pl)及总修正因子k_(pl)的实验值。结果表明,通过c_(pl)和h_(pl)组合或仅使用k_(pl)均可将水等效材料测量结果转换为水吸收剂量。比较PDD曲线表明,在10~20 MeV电子能量下3种水等效材料通过c_(pl)-h_(pl)修正后的R_(50),较水中测量最大偏差分别为0.19%、0.28%、0.22%;经k_(pl)修正得到的R_(50),较水中测量最大偏差分别为0.23%、0.29%、0.18%。结论:研究提供了多种材料c_(pl)-h_(pl)、k_(pl)的实验值,可方便用户快速完成电子束水吸收剂量的测量,相比于c_(pl)-h_(pl),使用k_(pl)更加简单高效。 展开更多
关键词 电离辐射计量 吸收剂量 电子束 缩放因子 修正因子 水等效材料
下载PDF
事故吸入^(241)Am后RBE加权吸收剂量系数计算
17
作者 陈倩兰 陈宝维 +2 位作者 夏益华 骆志平 刘森林 《辐射防护》 CAS CSCD 北大核心 2024年第1期27-32,共6页
当已经发生或即将发生放射性核素急性大量摄入时,对于确定效应(或组织反应)剂量范围,需要一个能够快速估计敏感靶器官或组织在短时间内吸收辐射能量的技术手段或工具,从而能够基于国际原子能机构(IAEA)安全导则GSG-2进行核与辐射应急响... 当已经发生或即将发生放射性核素急性大量摄入时,对于确定效应(或组织反应)剂量范围,需要一个能够快速估计敏感靶器官或组织在短时间内吸收辐射能量的技术手段或工具,从而能够基于国际原子能机构(IAEA)安全导则GSG-2进行核与辐射应急响应和其他响应行动决策,尽可能地减少受照射人员的急性大剂量照射、保护人员的生命健康。本文在系统研究国际放射防护委员会(ICRP)呼吸道模型、系统模型、消化道模型设计原理和参数建立依据基础上,编写^(241)Am为代表的超铀核素吸入后的滞留排泄份额m(t)计算程序,计算事故吸入^(241)Am后敏感靶器官的短期相对生物效应(RBE)加权吸收剂量AD(30)_(T)系数,并经验证确保计算结果正确。 展开更多
关键词 生物动力学模型 RBE加权 吸收剂量系数 滞留排泄份额 验证 确定效应 ^(241)Am
下载PDF
金属有机框架材料(MOFs)的电子束辐射稳定性
18
作者 刘泽鹏 蒙宇 +3 位作者 李林繁 李景烨 王自强 虞鸣 《辐射研究与辐射工艺学报》 CAS CSCD 2024年第1期18-27,共10页
本研究在不同气氛(空气、氮气)、分散液(水、甲醇、乙醇)以及不同剂量条件下对4种典型的金属有机框架材料(MOFs)(MIL-101(Cr)、ZIF-8、UiO-66和UiO-66-NH2)进行了电子束辐照处理。通过傅里叶变换红外光谱、X射线衍射谱和扫描电子显微镜... 本研究在不同气氛(空气、氮气)、分散液(水、甲醇、乙醇)以及不同剂量条件下对4种典型的金属有机框架材料(MOFs)(MIL-101(Cr)、ZIF-8、UiO-66和UiO-66-NH2)进行了电子束辐照处理。通过傅里叶变换红外光谱、X射线衍射谱和扫描电子显微镜等方法对MOFs材料在辐照前后的化学组成、晶体结构和表面形貌进行表征。结果表明,上述4种MOFs材料在高于5000 kGy的剂量辐照后,其相应的红外特征峰、衍射峰和表面形貌特征均未产生显著变化,表现出了良好的辐射稳定性。这为MOFs材料在辐射环境下的进一步应用提供了研究基础。 展开更多
关键词 金属有机框架材料(MOFs) 辐射稳定性 辐照 吸收剂量
下载PDF
Irradiation Dose for the Insect Disinfestation and Mildew Control of Peanut 被引量:1
19
作者 冯敏 朱佳廷 +4 位作者 李澧 李淑荣 杨萍 王德宁 顾贵强 《Agricultural Science & Technology》 CAS 2014年第3期477-479,共3页
The bulk peanuts were used as the materials. After ),-ray irradiation of different doses, the peanuts were stored up at room temperature, and the degree of pest infection and gradient of mould infection were observed... The bulk peanuts were used as the materials. After ),-ray irradiation of different doses, the peanuts were stored up at room temperature, and the degree of pest infection and gradient of mould infection were observed regularly. The results showed that insects began to appear in the unirradiated peanuts in 2 months, while after 4 months, the pest infection rate increased with the prolonged storage time, and the pest infection rate reached up to 58%-100% after 6 months of storage. However, the irradiated peanuts did not suffer from the pest infection throughout the storage. The unirradiated peanuts were contaminated by moulds after three months of storage, while the peanuts with an irradiation dose of 0.3-0.5 kGy were mildewed after 6 months of storage, while those with an irradiation dose of 1.0, 4.0 kGy had no mould after 12 months of storage. Combined with relevant international and national standards as well as the findings of scholars at home and abroad, the minimum effective irradiation dose for insect disinfestations of peanuts was 0,3 kGy, and the minimum effective irradiation dose for mildew control was 1.0 kGy, while the maximum tolerance dose was 4.0 kGy. 展开更多
关键词 PEANUT irradiation for insect disinfestation irradiation for mildew control absorbed dose
下载PDF
质子束水量热计中量热芯的超纯水制备与预辐照
20
作者 王菲菲 高飞 +4 位作者 丁雨阳 王子业 董璐琪 王靖谦 刘蕴韬 《同位素》 CAS 2024年第1期36-41,共6页
针对质子束的水吸收剂量绝对测量中化学热缺陷的修正问题,本研究基于热敏电阻研制水量热计,并进行气体饱和超纯水系统的设计。通过向量热芯内的超纯水充入高纯气体形成饱和状态,最大程度减少辐射化学反应的产额。在量热芯封装后通过预辐... 针对质子束的水吸收剂量绝对测量中化学热缺陷的修正问题,本研究基于热敏电阻研制水量热计,并进行气体饱和超纯水系统的设计。通过向量热芯内的超纯水充入高纯气体形成饱和状态,最大程度减少辐射化学反应的产额。在量热芯封装后通过预辐照,使量热芯超纯水中O2充分发生辐解反应,使量热芯内水环境达到无热损的稳定状态,成功研制了稳定的零热损水量热计,减少了量热芯热损对水吸收剂量绝对测量结果的影响,可为后续水吸收剂量的绝对测量提供技术支持。 展开更多
关键词 水量热计 鼓泡实验 绝对测量 热损失 水吸收剂量
下载PDF