Study on sex differences and potential clinical value of threedimensional computerized tomography pelvimetry in rectal cancer patients
1
作者 Xiao-Cong Zhou Fei-Yue Ke +2 位作者 Gaurav Dhamija Hao Chen Qiang Wang 《World Journal of Gastrointestinal Oncology》 SCIE 2024年第3期773-786,共14页
BACKGROUND Laparoscopic rectal cancer radical surgery is a complex procedure affected by various factors.However,the existing literature lacks standardized parameters for the pelvic region and soft tissues,which hampe... BACKGROUND Laparoscopic rectal cancer radical surgery is a complex procedure affected by various factors.However,the existing literature lacks standardized parameters for the pelvic region and soft tissues,which hampers the establishment of consistent conclusions.AIM To comprehensively assess 16 pelvic and 7 soft tissue parameters through computerized tomography(CT)-based three-dimensional(3D)reconstruction,providing a strong theoretical basis to address challenges in laparoscopic rectal cancer radical surgery.METHODS We analyzed data from 218 patients who underwent radical laparoscopic surgery for rectal cancer,and utilized CT data for 3D pelvic reconstruction.Specific anatomical points were carefully marked and measured using advanced 3D modeling software.To analyze the pelvic and soft tissue parameters,we emp-loyed statistical methods including paired sample t-tests,Wilcoxon rank-sum tests,and correlation analysis.RESULTS The investigation highlighted significant sex disparities in 14 pelvic bone parameters and 3 soft tissue parameters.Males demonstrated larger measurements in pelvic depth and overall curvature,smaller measurements in pelvic width,a larger mesorectal fat area,and a larger anterior-posterior abdominal diameter.By contrast,females exhibited wider pelvises,shallower depth,smaller overall curvature,and an increased amount of subcutaneous fat tissue.However,there were no significant sex differences observed in certain parameters such as sacral curvature height,superior pubococcygeal diameter,rectal area,visceral fat area,waist circumference,and transverse abdominal diameter.CONCLUSION The reconstruction of 3D CT data enabled accurate pelvic measurements,revealing significant sex differences in both pelvic and soft tissue parameters.This study design offer potential in predicting surgical difficulties and creating personalized surgical plans for male rectal cancer patients with a potentially“difficult pelvis”,ultimately improving surgical outcomes.Further research and utilization of these parameters could lead to enhanced surgical methods and patient care in laparoscopic rectal cancer radical surgery. 展开更多
关键词 computerized tomography Rectal cancer Three-dimensional reconstruction PELVIMETRY Sex differences
下载PDF
Computerized tomography-guided therapeutic percutaneous puncture catheter drainage-combined with somatostatin for severe acute pancreatitis: An analysis of efficacy and safety
2
作者 Xue-Lan Zheng Wan-Ling Li +1 位作者 Yan-Ping Lin Ting-Long Huang 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第1期59-66,共8页
BACKGROUND Severe acute pancreatitis(SAP),a condition with rapid onset,critical condition and unsatisfactory prognosis,poses a certain threat to human health,warranting optimization of relevant treatment plans to impr... BACKGROUND Severe acute pancreatitis(SAP),a condition with rapid onset,critical condition and unsatisfactory prognosis,poses a certain threat to human health,warranting optimization of relevant treatment plans to improve treatment efficacy.AIM To evaluate the efficacy and safety of computerized tomography-guided the-rapeutic percutaneous puncture catheter drainage(CT-TPPCD)combined with somatostatin(SS)in the treatment of SAP.METHODS Forty-two SAP patients admitted to The Second Affiliated Hospital of Fujian Medical University from June 2020 to June 2023 were selected.On the basis of routine treatment,20 patients received SS therapy(control group)and 22 patients were given CT-TPPCD plus SS intervention(research group).The efficacy,safety(pancreatic fistula,intra-abdominal hemorrhage,sepsis,and organ dysfunction syndrome),abdominal bloating and pain relief time,bowel recovery time,hospital stay,inflammatory indicators(C-reactive protein,interleukin-6,and pro-calcitonin),and Acute Physiology and Chronic Health Evaluation(APACHE)II score of both groups were evaluated for comparison.RESULTS Compared with the control group,the research group had a markedly higher total effective rate,faster abdominal bloating and pain relief and bowel recovery,INTRODUCTION Pancreatitis,an inflammatory disease occurring in the pancreatic tissue,is classified as either acute or chronic and is associated with high morbidity and mortality,imposing a socioeconomic burden[1,2].The pathogenesis of this disease involves early protease activation,activation of nuclear factor kappa-B-related inflammatory reactions,and infiltration of immune cells[3].Severe acute pancreatitis(SAP)is a serious condition involving systemic injury and subsequent possible organ failure,accounting for 20%of all acute pancreatitis cases[4].SAP is also characterized by rapid onset,critical illness and unsatisfactory prognosis and is correlated with serious adverse events such as systemic inflammatory response syn-drome and acute lung injury,threatening the health of patients[5,6].Therefore,timely and effective therapeutic inter-ventions are of great significance for improving patient prognosis and ensuring therapeutic effects.Somatostatin(SS),a peptide hormone that can be secreted by endocrine cells and the central nervous system,is in-volved in the regulatory mechanism of glucagon and insulin synthesis in the pancreas[7].It has complex and pleiotropic effects on the gastrointestinal tract,which can inhibit the release of gastrointestinal hormones and negatively modulate the exocrine function of the stomach,pancreas and bile,while exerting a certain influence on the absorption of the di-gestive system[8,9].SS has shown certain clinical effectiveness when applied to SAP patients and can regulate the severity of SAP and immune inflammatory responses,and this regulation is related to its influence on leukocyte apoptosis and adhesion[10,11].Computerized tomography-guided therapeutic percutaneous puncture catheter drainage(CT-TPPCD)is a surgical procedure to collect lesion fluid and pus samples from necrotic lesions and perform puncture and drainage by means of CT image examination and precise positioning[12].In the research of Liu et al[13],CT-TPPCD applied to pa-tients undergoing pancreatic surgery contributes to not only good curative effects but also a low surgical risk.Baudin et al[14]also reported that CT-TPPCD has a clinical success rate of 64.6%in patients with acute infectious necrotizing pan-creatitis,with nonfatal surgery-related complications found in only two cases,suggesting that this procedure is clinically effective and safe in the treatment of the disease.In light of the limited studies on the efficacy and safety of SS plus CT-TPPCD in SAP treatment,this study performed a relevant analysis to improve clinical outcomes in SAP patients. 展开更多
关键词 computerized tomography guidance Therapeutic percutaneous puncture catheter drainage SOMATOSTATIN Severe acute pancreatitis Efficacy and safety
下载PDF
Detection of tracheal branching with computerized tomography:The relationship between the angles and age-gender
3
作者 Şevket Kahraman Mesut Furkan Yazar +2 位作者 Hüseyin Aydemir Mecit Kantarci Sonay Aydin 《World Journal of Radiology》 2023年第4期118-126,共9页
BACKGROUND The data obtained on the anatomical knowledge of the tracheobronchial system can be used for diagnosis,treatment and interventional interventions in areas such as anesthesia,thoracic surgery,pulmonary physi... BACKGROUND The data obtained on the anatomical knowledge of the tracheobronchial system can be used for diagnosis,treatment and interventional interventions in areas such as anesthesia,thoracic surgery,pulmonary physiology.AIM To determine the tracheobronchial branching angles in pediatric and adult populations by using the multislice computed tomography(CT)and minimum intensity projection(MinIP)technique,which is a non-invasive method.METHODS Our study was carried out retrospectively.Patients who underwent contrast and non-contrast CT examination,whose anatomically and pathophysiologically good tracheobronchial system and lung parenchyma images were obtained,were included in the study.Measurements were made in the coronal plane of the lung parenchyma.In the coronal plane,right main bronchus-left main bronchus angle,right upper lobe bronchus-intermedius bronchus angle,right middle lobe bronchus-right lower lobe bronchus angle,left upper lobe bronchus-left lower lobe bronchus angle were measured.RESULTS The study population consisted of 1511 patients,753 pediatric(mean age:13.4±4.3;range:1-18 years)and 758 adults(mean age:54.3±17.3;range:19-94 years).In our study,tracheal bifurcation angle was found to be 73.3°±13.7°(59.6°-87°)in the whole population.In the pediatric group,the right-left main coronal level was found to be higher in boys compared to girls(74.6°±12.9°vs 71.2°±13.9°,P=0.001).In the adult group,the right-left main coronal level was found to be lower in males compared to females(71.9°±12.9°vs 75.8°±14.7°,P<0.001).CONCLUSIONS Our study,with the number of 1511 patients,is the first study in the literature with the largest number of patient populations including pediatric and adult demographic data,measuring the angle values of the tracheobronchial system using multislice CT and MinIP technique.Study data will not only be a guide during invasive procedures,but it can also guide studies to be done with imaging methods. 展开更多
关键词 Tracheobronchial branching angles Subcarinal angle Multislice computerized tomography Minimum intensity projection technique
下载PDF
Tracking the phase transformation and microstructural evolution of Sn anode using operando synchrotron X-ray energy-dispersive diffraction and X-ray tomography 被引量:1
4
作者 Kang Dong Fu Sun +4 位作者 Andre Hilger Paul H.Kamm Markus Osenberg Francisco Garcia-Moreno Ingo Manke 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2023年第1期429-437,I0011,共10页
Tin(Sn)holds great promise as an anode material for next-generation lithium(Li)ion batteries but suffers from massive volume change and poor cycling performance.To clarify the dynamic chemical and microstructural evol... Tin(Sn)holds great promise as an anode material for next-generation lithium(Li)ion batteries but suffers from massive volume change and poor cycling performance.To clarify the dynamic chemical and microstructural evolution of Sn anode during lithiation and delithiation,synchrotron X-ray energydispersive diffraction and X-ray tomography are simultaneously employed during Li/Sn cell operation.The intermediate Li-Sn alloy phases during de/lithiation are identified,and their dynamic phase transformation is unraveled which is further correlated with the volume variation of the Sn at particle-and electrode-level.Moreover,we find that the Sn particle expansion/shrinkage induced particle displacement is anisotropic:the displacement perpendicular to the electrode surface(z-axis)is more pronounced compared to the directions(x-and y-axis)along the electrode surface.This anisotropic particle displacement leads to an anisotropic volume variation at the electrode level and eventually generates a net electrode expansion towards the separator after cycling,which could be one of the root causes of mechanical detachment and delamination of electrodes during long-term operation.The unraveled chemical evolution of Li-Sn and deep insights into the microstructural evolution of Sn anode provided here could guide future design and engineering of Sn and other alloy anodes for high energy density Li-and Na-ion batteries. 展开更多
关键词 Sn anode Li-Sn phase transformation x-ray tomography Operando x-ray diffraction Anisotropic displacement Digital volume correlation(DVC)
下载PDF
Positron emission tomography/computerized tomography in the evaluation of primary non-Hodgkin's lymphoma of prostate 被引量:4
5
作者 Bo Pan Jian-Kui Han +1 位作者 Shi-Cun Wang Ao Xu 《World Journal of Gastroenterology》 SCIE CAS 2013年第39期6699-6702,共4页
Primary malignant lymphoma of the prostate is exceedingly rare.Here we report a case of a 65-year-old man who presented with increased urinary frequency,urinary urgency,and urinary incontinence for two years.Benign pr... Primary malignant lymphoma of the prostate is exceedingly rare.Here we report a case of a 65-year-old man who presented with increased urinary frequency,urinary urgency,and urinary incontinence for two years.Benign prostatic hypertrophy was suspected at primary impression.Ultrasound revealed a hypoechoic lesion of the prostate.The total serum prostate-specific antigen was within normal range.Positron emission tomography/computerized tomography(PET/CT)showed a hypermetabolic prostatic lesion.Prostate biopsy was consistent with a non-germinal center diffuse large B cell lymphoma.There was complete remission of the prostatic lesion following six cycles of chemotherapy as shown on the second PET/CT imaging.18F-fluoro-deoxy glucose PET/CT is not only a complement to conventional imaging,but also plays a significant role in the diagnosis and evaluation of treatment response of prostatic lymphoma. 展开更多
关键词 Fluoro-Deoxy-Glucose Positron emission tomography/computerized tomography Non-Hodgkin’s LYMPHOMA PROSTATIC LYMPHOMA EVALUATION
下载PDF
Application of Proton Magnetic Resonance Spectroscopy and Computerized Tomography in the Diagnosis and Treatment of Nonalcoholic Fatty Liver Disease 被引量:4
6
作者 王南 董慧 +1 位作者 魏世超 陆付耳 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2008年第3期295-298,共4页
In order to investigate the application of proton magnetic resonance spectroscopy (ill-MRS) and computerized tomography (CT) in the quantitative diagnosis of nonalcoholic fatty liver disease (NAFLD) and evaluati... In order to investigate the application of proton magnetic resonance spectroscopy (ill-MRS) and computerized tomography (CT) in the quantitative diagnosis of nonalcoholic fatty liver disease (NAFLD) and evaluation of therapeutic effects, 22 patients with NAFLD were selected according to the Chinese Medical Association's (CMA) standard of the NAFLD in comparison with 20 healthy volunteers (as control group). Blood samples for biochemistry were collected. The severity of hepatosteatosis was evaluated by ^1H-MRS scan and CT scan of liver. The intrahepatic content of lipid (IHCL) and CT value ratio of liver to spleen were calculated. The patients in NAFLD group were treated with Ganzhixiao Capsule for 8 weeks. The changes in IHCL and CT value ratio of liver to spleen were observed before and after treatment. In NAFLD group serum ALT, TG, IHCL calculated by ^1HMRS were increased and CT value ratio of liver to spleen decreased significantly as compared with control group. After treatment for 8 weeks serum ALT, TG, IHCL were decreased significantly, while CT value ratio of liver to spleen increased significantly in NAFLD group. It was suggested that IHCL could be measured precisely by ^1HMRS. NAFLD was treated effectively by Ganzhixiao capsule. 展开更多
关键词 proton magnetic resonance spectroscopy computerized tomography nonalcoholic fatty liver disease
下载PDF
Finding the magnetopause location using soft X-ray observations and a statistical inverse method 被引量:1
7
作者 Gonzalo Cucho-Padin Hyunju Connor +2 位作者 Jaewoong Jung Brian Walsh David G.Sibeck 《Earth and Planetary Physics》 EI CSCD 2024年第1期184-203,共20页
Variability in the location and shape of the dayside magnetopause is attributed to magnetic reconnection,a fundamental process that enables the transfer of mass,energy,and momentum from the solar wind into the magneto... Variability in the location and shape of the dayside magnetopause is attributed to magnetic reconnection,a fundamental process that enables the transfer of mass,energy,and momentum from the solar wind into the magnetosphere.The spatial and temporal properties of the magnetopause,under varying solar and magnetospheric conditions,remain largely unknown because empirical studies using in-situ observations are challenging to interpret.Global wide field-of-view(FOV)imaging is the only means to simultaneously observe the spatial distribution of the plasma properties over the vast dayside magnetospheric region and,subsequently,quantify the energy transport from the interplanetary medium into the terrestrial magnetosphere.Two upcoming missions,ESA/CAS SMILE and NASA’s LEXI will provide wide-field imagery of the dayside magnetosheath in soft X-rays,an emission generated by charge exchange interactions between high charge-state heavy ions of solar wind origin and exospheric neutral atoms.High-cadence two-dimensional observations of the magnetosheath will allow the estimation of dynamic properties of its inner boundary,the magnetopause,and enable studies of its response to changes in the solar wind dynamic pressure and interplanetary magnetic field orientation.This work introduces a statistically-based estimation approach based on inverse theory to estimate the spatial distribution of magnetosheath soft X-ray emissivities and,with this,identify the location of the magnetopause over the Sun−Earth line.To do so,we simulate the magnetosheath structure using the MHD-based OpenGGCM model and generate synthetic soft X-ray images using LEXI’s orbit and attitude information.Our results show that 3-D estimations using the described statistically-based technique are robust against Poisson-distributed shot noise inherent to soft X-ray images.Also,our proposed methodology shows that the accuracy of both three-dimensional(3-D)estimation and the magnetopause standoff distance calculation highly depends on the observational point. 展开更多
关键词 MAGNETOPAUSE soft x-ray tomography
下载PDF
Tomographic reconstruction of the Earth’s magnetosheath from multiple spacecraft:a theoretical study 被引量:1
8
作者 A.M.Jorgensen TianRan Sun +4 位作者 Y.Huang L.Li R.Xu L.Dai Chi Wang 《Earth and Planetary Physics》 EI CSCD 2024年第1期204-214,共11页
Following our earlier work on tomographic reconstruction of the magnetosheath soft X-ray emissions with superposed epoch analysis of many images recorded from a single spacecraft we now explore the instantaneous recon... Following our earlier work on tomographic reconstruction of the magnetosheath soft X-ray emissions with superposed epoch analysis of many images recorded from a single spacecraft we now explore the instantaneous reconstruction of the magnetosheath and magnetopause using a few images recorded simultaneously from a few spacecraft.This work is motivated by the prospect of possibly having two or three soft X-ray imagers in space in the coming years,and that many phenomena which occur at the magnetopause boundary,such as reconnection events and pressure pulse responses,do not lend themselves as well to superposed epoch analysis.If the reconstruction is successful-which we demonstrate in this paper that it can be-this collection of imagers can be used to reconstruct the magnetosheath and magnetopause from a single image from each spacecraft,allowing for high time resolution reconstructions.In this paper we explore the reconstruction using,two,three,and four spacecraft.We show that the location of the subsolar point of the magnetopause can be determined with just two satellites,and that volume emissions of soft X-rays,and the shape of the boundary,can be reconstructed using three or more satellites. 展开更多
关键词 MAGNETOSHEATH tomography soft x-ray imaging SMILE
下载PDF
Seeing through Materials:X-Ray Imaging Using Computed Tomography
9
作者 Yisheng Miao Chengpeng Xue +2 位作者 Xuelong Wu Zhongyao Li Junsheng Wang 《Journal of Beijing Institute of Technology》 EI CAS 2023年第4期494-516,共23页
X-ray computed tomography(XCT)has recently emerged as a powerful tool for characterizing the evolution of microstructure during phase transformation in three dimensional(3D)such as dendritic solidification of alloys.T... X-ray computed tomography(XCT)has recently emerged as a powerful tool for characterizing the evolution of microstructure during phase transformation in three dimensional(3D)such as dendritic solidification of alloys.This paper briefly reviews the recent advances in the in-situ observation of aluminium alloys,magnesium alloys and nickel-based superalloys during solidification using laboratory XCT and synchrotron X-ray sources.The focus is on the growth kinetics of dendrites,porosity and secondary phases.In addition,in-situ characterization during the loading and corrosion process is also discussed. 展开更多
关键词 x-ray computed tomography(XCT) SYNCHROTRON DENDRITE POROSITY ALLOYS
下载PDF
Effects of Irregular Respiratory Motion on the Positioning Accuracy of Moving Target with Free Breathing Cone-Beam Computerized Tomography 被引量:1
10
作者 Xiang Li Tianfang Li +9 位作者 Ellen Yorke Gig Mageras Xiaoli Tang Maria Chan Weijun Xiong Marsha Reyngold Richard Gewanter Abraham Wu John Cuaron Margie Hunt 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2018年第2期173-183,共11页
For positioning a moving target, a maximum intensity projection (MIP) or average intensity projection (AIP) image derived from 4DCT is often used as the reference image which is matched to free breathing cone-beam CT ... For positioning a moving target, a maximum intensity projection (MIP) or average intensity projection (AIP) image derived from 4DCT is often used as the reference image which is matched to free breathing cone-beam CT (FBCBCT) before treatment. This method can be highly accurate if the respiratory motion of the patient is stable. However, a patient’s breathing pattern is often irregular. The purpose of this study is to investigate the effects of irregular respiration on positioning accuracy for a moving target aligned with FBCBCT. Nine patients’ respiratory motion curves were selected to drive a Quasar motion phantom with one embedded cubic and two spherical targets. A 4DCT of the phantom was acquired on a CT scanner (Philips Brilliance 16) equipped with a Varian RPM system. The phase binned 4DCT images and the corresponding MIP and AIP images were transferred into Eclipse for analysis. FBCBCTs of the phantom driven by the same respiratory curves were also acquired on a Varian TrueBeam and fused such that both CBCT and MIP/AIP images share the same target zero positions. The sphere and cube volumes and centroid differences (alignment error) determined by MIP, AIP and FBCBCT images were calculated, respectively. Compared to the volume determined by MIP, the volumes of the cube, large sphere, and small sphere in AIP and FBCBCT images were smaller. The alignment errors for the cube, large sphere and small sphere with center to center matches between MIP and FBCBCT were 2.5 ± 1.8 mm, 2.4 ± 2.1 mm, and 3.8 ± 2.8 mm, and the alignment errors between AIP and FBCBCT were 0.5 ± 1.1 mm, 0.3 ± 0.8 mm, and 1.8 ± 2.0 mm, respectively. AIP images appear to be superior reference images to MIP images. However, irregular respiratory pattern could compromise the positioning accuracy, especially for smaller targets. 展开更多
关键词 CONE Beam computerized tomography RESPIRATORY Motion Effect
下载PDF
Importance of computed tomography in posterior malleolar fractures:Added information to preoperative X-ray studies
11
作者 NoéDe Marchi Neto Pietro Felice Tomazini Nesello +3 位作者 Jordanna Maria Bergamasco Marco Tulio Costa Ralph Walter Christian Nilson Roberto Severino 《World Journal of Orthopedics》 2023年第12期868-877,共10页
BACKGROUND Ankle fractures are common lesions of the lower limbs.Approximately 40%of ankle fractures affect the posterior malleolus(PM).Historically,PM osteosynthesis was recommended when PM size in X-ray images was g... BACKGROUND Ankle fractures are common lesions of the lower limbs.Approximately 40%of ankle fractures affect the posterior malleolus(PM).Historically,PM osteosynthesis was recommended when PM size in X-ray images was greater than 25%of the joint.Currently,computed tomography(CT)has been gaining traction in the preoperative evaluation of ankle fractures.AIM To elucidate the similarity in dimensions and to correlate PM size in X-ray images with the articular surface of the affected tibial plafond in the axial view on CT(AXCT)of a PM fracture.METHODS Eighty-one patients(mean age:39.4±13.5 years)were evaluated(54.3%were male).Two independent examiners measured PM size in profile X-ray images(PMXR)and sagittal CT(SAGCT)slices.The correlation of the measurements between the examiners and the difference in the PM fragment sizes between the two images were compared.Next,the PM size in PMXR was compared with the surface of the tibial plafond involved in the fracture in AXCT according to the Haraguchi classification.RESULTS The correlation rates between the examiners were 0.93 and 0.94 for PMXR and SAGCT,respectively(P<0.001).Fragments were 2.12%larger in SAGCT than in PMXR(P=0.018).In PMXR,there were 56 cases<25%and 25 cases≥25%.When PMXR was<25%,AXCT corresponded to 10.13%of the tibial plafond.When PMXR was≥25%,AXCT was 24.52%(P<0.001).According to the Haraguchi classification,fracture types I and II had similar PMXR measurements that were greater than those of type III.When analyzing AXCT,a significant difference was found between the three types,with II>I>III(P<0.001).CONCLUSION PM fractures show different sizes using X-ray or CT images.CT showed a larger PM in the sagittal plane and allowed the visualization of the real dimensions of the tibial plafond surface. 展开更多
关键词 Ankle fracture Posterior malleolar fracture Computed tomography x-ray Posterior malleolus fracture Trimalleolar facture
下载PDF
The Differences of Interstitial Lung Diseases in High-Resolution Computerized Tomography and Pulmonary Function Test among Different Connective Tissue Diseases, and the Correlated Factors 被引量:1
12
作者 Zhen Jiang Wenyou Pan +1 位作者 Jinhui Tao Xiangpei Li 《Open Journal of Rheumatology and Autoimmune Diseases》 2018年第2期53-65,共13页
Objective. To study the difference of interstitial lung diseases (ILDs) in high-resolution computerized tomography and pulmonary function test among different connective tissue diseases (CTDs). Methods. 209 patients w... Objective. To study the difference of interstitial lung diseases (ILDs) in high-resolution computerized tomography and pulmonary function test among different connective tissue diseases (CTDs). Methods. 209 patients with different CTDs were recruited and underwent lung HRCT and PFT. Eerythrocyte sedimentation rate (ESR), C-reactive protein (CRP), serum ferritin (SF), anti-SSA, and so on were tested. Based on HRCT, a patient was classified into ILD group (CTD+ILD) or non-ILD group (CTD-ILD). HRCT, PFT, and laboratory markers were compared according to CTDs and CTD-associated ILDs. Results. The incidences of ILD were 79.6%, 82.0%, 89.7%, and 97.1% respectively for Rheumatoid arthritis (RA), primary Sjogren’s symptom (pSS), dermatomyositis/polymyositis (DM/PM), and systemic sclerosis (SSc) groups. RA and pSS patients exhibited more nodules, patching, ground-glass opacity, and cord shadow foci in HRCT, DM/PM and SSc patients exhibited more reticular opacity and honeycombing foci. RA and pSS patients exhibited more obstructive ventilatory disorder, small airway dysfunction and emphysema in PFT, and DM/PM and SSc patients exhibited more restrictive ventilatory disorder, mixed ventilatory disorder. ESR, CRP and SF were significantly higher in total CTD+ILD group than in total CTD-ILD group (P = 0.047, 0.006, 0.004, respectively), and higher in different CTD+ ILD groups than in comparable CTD-ILD groups (P = 0.049, 0.048, and 0.023, pSS+ILD, SSc+ILD and RA+ILD compared to pSS-ILD, SSc-ILD and RA-ILD, respectively for ESR, CRP, SF). The positive rate of anti-SSA was significantly higher in DM/PM+ILD group than in DM/PM-ILD group (P = 0.025). Conclusions. The manifestations and incidences of ILDs differ among different CTDs in HRCT and PFT, and inflammation and anti-SSA are positively correlated with ILDs in different CTDs, which provide important evidences for judging disease condition and prognosis. 展开更多
关键词 CONNECTIVE Tissue Diseases INTERSTITIAL lung Disease HIGH-RESOLUTION computerized tomography PULMONARY Function Test Inflammation
下载PDF
Pore structure of ore granular media by computerized tomography image processing 被引量:6
13
作者 吴爱祥 杨保华 +1 位作者 习泳 江怀春 《Journal of Central South University of Technology》 EI 2007年第2期220-224,共5页
The pore structure images of ore particles located at different heights of leaching column were scanned with X-ray computerized tomography (CT) scanner, the porosity and pore size distribution were calculated and the ... The pore structure images of ore particles located at different heights of leaching column were scanned with X-ray computerized tomography (CT) scanner, the porosity and pore size distribution were calculated and the geometrical shape and connectivity of pores were analyzed based on image process method, and the three dimensional reconstruction of pore structure images was realized. The results show that the porosity of ore particles bed in leaching column is 42.92%, 41.72%, 39.34% at top, middle and bottom zone, respectively. Obviously it has spatial variability and decreases appreciably along the height of the column. The overall average porosity obtained by image processing is 41.33% while the porosity gotten from general measurement method in laboratory is 42.77% showing the results of both methods are consistent well. The pore structure of ore granular media is characterized as a dynamical space network composed of interconnected pore bodies and pore throats. The ratio of throats with equivalent diameter less than 1.91 mm to the total pores is 29.31%, and that of the large pores with equivalent diameter more than 5.73 mm is 2.90%. 展开更多
关键词 矿石颗粒介质 孔隙度 计算机化层析成像 图象处理
下载PDF
Comments on the article about correlation between computerized tomography and surgery in acute pancreatitis 被引量:1
14
作者 Enver Zerem Goran Imamovi +1 位作者 Zoran Mavija Bahrija Harai 《World Journal of Gastroenterology》 SCIE CAS CSCD 2011年第3期407-408,共2页
We read with great interest the article by Vege et al published in issue 34 of World J Gastroenterol 2010. The article evaluates the ability of contrast-enhanced computerized tomography (CECT) to characterize the natu... We read with great interest the article by Vege et al published in issue 34 of World J Gastroenterol 2010. The article evaluates the ability of contrast-enhanced computerized tomography (CECT) to characterize the nature of peripancreatic collections found at surgery. The results of their study indicate that most of the peripancreatic collections seen on CECT in patients with severe acute pancreatitis who require operative intervention contain necrotic tissue and CECT has a limited role in differentiating various types of collections. However, there are some points that need to be addressed, including data about the stage of acute pancreatitis in which CECT was done and the time span between CECT examination and surgery. 展开更多
关键词 重症急性胰腺炎 计算机断层扫描 手术 CECT 电脑 评论 胃肠病学 时间跨度
下载PDF
Assessing efficacy of standard impregnation techniques on die-cast aluminum alloys using X-ray micro-CT
15
作者 Ajith Bandara Koichi Kan +3 位作者 Katanaga Yusuke Natsuto Soga Akifumi Koike Toru Aoki 《China Foundry》 SCIE EI CAS CSCD 2024年第3期276-286,共11页
Utilizing lightweight Al alloys in various industrial applications requires achieving precise pressure tightness and leak requirements.Vacuum pressure impregnation(VPI)with thermosetting polymers is commonly used to a... Utilizing lightweight Al alloys in various industrial applications requires achieving precise pressure tightness and leak requirements.Vacuum pressure impregnation(VPI)with thermosetting polymers is commonly used to address leakage defects in die-cast Al alloys.In this study,the efficacy of the VPI technique in sealing alloy parts was investigated using a combination of nondestructive micro X-ray computed tomography(micro XCT)and a standard leak test.The results demonstrate that the commonly used water leak test is insufficient for determining the sealing performance.Instead,micro XCT shows distinct advantages by enabling more comprehensive analysis.It reveals the presence of a low atomic number impregnates sealant within casting defects,which has low grey contrast and allows for visualizing primary leakage paths in 3D.The effective atomic number of impregnated resin is 6.75 and that of Al alloy is 13.69 by dual-energy X-ray CT.This research findings will contribute to enhancing the standard VPI process parameters and the properties of impregnating sealants to improve quality assurance for impregnation in industrial metals. 展开更多
关键词 nondestructive testing Al alloy die-casting vacuum pressure impregnation micro x-ray computed tomography duel-energy x-ray CT
下载PDF
Insights into the hydrogen evolution reaction in vanadium redox flow batteries:A synchrotron radiation based X-ray imaging study
16
作者 Kerstin Köble Alexey Ershov +7 位作者 Kangjun Duan Monja Schilling Alexander Rampf Angelica Cecilia TomášFaragó Marcus Zuber Tilo Baumbach Roswitha Zeis 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2024年第4期132-144,共13页
The parasitic hydrogen evolution reaction(HER)in the negative half-cell of vanadium redox flow batteries(VRFBs)causes severe efficiency losses.Thus,a deeper understanding of this process and the accompanying bubble fo... The parasitic hydrogen evolution reaction(HER)in the negative half-cell of vanadium redox flow batteries(VRFBs)causes severe efficiency losses.Thus,a deeper understanding of this process and the accompanying bubble formation is crucial.This benchmarking study locally analyzes the bubble distribution in thick,porous electrodes for the first time using deep learning-based image segmentation of synchrotron X-ray micro-tomograms.Each large three-dimensional data set was processed precisely in less than one minute while minimizing human errors and pointing out areas of increased HER activity in VRFBs.The study systematically varies the electrode potential and material,concluding that more negative electrode potentials of-200 m V vs.reversible hydrogen electrode(RHE)and lower cause more substantial bubble formation,resulting in bubble fractions of around 15%–20%in carbon felt electrodes.Contrarily,the bubble fractions stay only around 2%in an electrode combining carbon felt and carbon paper.The detected areas with high HER activity,such as the border subregion with more than 30%bubble fraction in carbon felt electrodes,the cutting edges,and preferential spots in the electrode bulk,are potential-independent and suggest that larger electrodes with a higher bulk-to-border ratio might reduce HER-related performance losses.The described combination of electrochemical measurements,local X-ray microtomography,AI-based segmentation,and 3D morphometric analysis is a powerful and novel approach for local bubble analysis in three-dimensional porous electrodes,providing an essential toolkit for a broad community working on bubble-generating electrochemical systems. 展开更多
关键词 Vanadium redox flow battery Synchrotron x-ray imaging tomography Hydrogen evolution reaction Gas bubbles Deep learning
下载PDF
Computed tomography-based nomogram of Siewert type Ⅱ/Ⅲ adenocarcinoma of esophagogastric junction to predict response to docetaxel, oxaliplatin and S-1
17
作者 Chuan-Qinyuan Zhou Dan Gao +7 位作者 Yan Gui Ning-Pu Li Wen-Wen Guo Hai-Ying Zhou Rui Li Jing Chen Xiao-Ming Zhang Tian-Wu Chen 《World Journal of Radiology》 2024年第1期9-19,共11页
BACKGROUND Neoadjuvant chemotherapy(NAC)has become the standard care for advanced adenocarcinoma of esophagogastric junction(AEG),although a part of the patients cannot benefit from NAC.There are no models based on ba... BACKGROUND Neoadjuvant chemotherapy(NAC)has become the standard care for advanced adenocarcinoma of esophagogastric junction(AEG),although a part of the patients cannot benefit from NAC.There are no models based on baseline computed tomography(CT)to predict response of Siewert type II or III AEG to NAC with docetaxel,oxaliplatin and S-1(DOS).AIM To develop a CT-based nomogram to predict response of Siewert type II/III AEG to NAC with DOS.METHODS One hundred and twenty-eight consecutive patients with confirmed Siewert type II/III AEG underwent CT before and after three cycles of NAC with DOS,and were randomly and consecutively assigned to the training cohort(TC)(n=94)and the validation cohort(VC)(n=34).Therapeutic effect was assessed by disease-control rate and progressive disease according to the Response Evaluation Criteria in Solid Tumors(version 1.1)criteria.Possible prognostic factors associated with responses after DOS treatment including Siewert classification,gross tumor volume(GTV),and cT and cN stages were evaluated using pretherapeutic CT data in addition to sex and age.Univariate and multivariate analyses of CT and clinical features in the TC were performed to determine independent factors associated with response to DOS.A nomogram was established based on independent factors to predict the response.The predictive performance of the nomogram was evaluated by Concordance index(C-index),calibration and receiver operating characteristics curve in the TC and VC.RESULTS Univariate analysis showed that Siewert type(52/55 vs 29/39,P=0.005),pretherapeutic cT stage(57/62 vs 24/32,P=0.028),GTV(47.3±27.4 vs 73.2±54.3,P=0.040)were significantly associated with response to DOS in the TC.Multivariate analysis of the TC also showed that the pretherapeutic cT stage,GTV and Siewert type were independent predictive factors related to response to DOS(odds ratio=4.631,1.027 and 7.639,respectively;all P<0.05).The nomogram developed with these independent factors showed an excellent performance to predict response to DOS in the TC and VC(C-index:0.838 and 0.824),with area under the receiver operating characteristic curve of 0.838 and 0.824,respectively.The calibration curves showed that the practical and predicted response to DOS effectively coincided.CONCLUSION A novel nomogram developed with pretherapeutic cT stage,GTV and Siewert type predicted the response of Siewert type II/III AEG to NAC with DOS. 展开更多
关键词 Esophagogastric junction ADENOCARCINOMA Neoadjuvant chemotherapy RESPONSE tomography x-ray computed Predictor
下载PDF
Screening for lung cancer with chest computerized tomography: Is it cost efficient?
18
作者 Tomasz Jaroslaw Szczesny Malgorzata Kanarkiewicz Janusz Kowalewski 《World Journal of Respirology》 2015年第2期160-165,共6页
Despite lung cancer(LC) screening by low-dose computerized tomography(LDCT) gaining many proponents worldwide, for many years it was not recognized as a life-prolonging and cost-effective procedure, until recently. Pr... Despite lung cancer(LC) screening by low-dose computerized tomography(LDCT) gaining many proponents worldwide, for many years it was not recognized as a life-prolonging and cost-effective procedure, until recently. Prospective observational studies had not been able to prove that this screening prolongs survival, but they helped to specify the inclusion and exclusion criteria. Long-awaited results of a prospective, randomized trial finally provided the evidence that LC screening with LDCT can prolong survival of the screened population. Several costeffectiveness analyses were performed to justify mass introduction of this screening. Results of these analyses are equivocal, although conclusions highly depend upon inclusion and exclusion criteria, methods of analysis and prices of medical procedures which differ between countries as well as the incidence of other pulmonary nodules, especially tuberculosis. Therefore, costeffectiveness analysis should be performed separately for every country. Cost-effectiveness depends especially upon the rate of false-positive results and the rate of unnecessary diagnostic, screening and treatment procedures. To ensure high cost-effectiveness, LC screening should be performed in accordance with screening protocol, in dedicated screening centers equipped with nodule volume change analysis, or as a prospective non-randomized trial, to ensure compliance with the inclusion and exclusion criteria. To ensure high cost-effectiveness of LC screening, future research should concentrate on determination of highrisk groups and further specifying the inclusion and exclusion criteria. 展开更多
关键词 Lung cancer Non-small cell lung cancers SCREENING COST-EFFECTIVENESS computerized tomography Low-dose computerized tomography
下载PDF
The possible value of ~18F-FDG positron emission tomography/computerized tomography imaging in detection of atherosclerotic plaque
19
作者 Jianwei Yuan Yanlin Feng +1 位作者 Lingxiao Fan Xiaohong He 《Journal of Nanjing Medical University》 2008年第1期61-65,共5页
Objective:To evaluate the clinical value with positron emission tomography/computerized tomography(PET/CT) imaging for the detection of vulnerable plaque in atherosclerotic lesions. Methods:Sixty people with a age... Objective:To evaluate the clinical value with positron emission tomography/computerized tomography(PET/CT) imaging for the detection of vulnerable plaque in atherosclerotic lesions. Methods:Sixty people with a age of over 60[mean age (69.2 ± 7.1)years] underwent three dimension(3D) whole-body fluorine-18-2-fluoro-2-deoxy-D-glucose(^18F-FDG) PET/CT imaging and were evaluated retrospectively, including 6 cases assessed as normal and 54 cases with active atherosclerotic plaque. Fifty-four cases with SUVs and CT values in the aortic wall of high-FDG-uptake were measured retrospectively. These high-FDG-uptake cases in the aortic wall were divided into three groups according their CT value. Cases in group 1 had high uptake in atherosclerotic lesions of the aortic wall with CT value of less than 60 Hu(soft plaque). Cases in group 2 had high uptake with CT value between 60-100 Hu (intermediate plaque), Cases in group 3 had high uptake with CT value more than 100 Hu(calcified plaque), Group 4 was normal. Results: In group 1, there were 42 high-FDG-uptake sites (average SUV 1.553 ± 0.486). In group 2, there were 30 high-FDG-uptake sites(average SUV 1.393 ± 0.296). In group 3, there were 36 high-FDG-uptake sites(average SUV 1.354 ± 0.189). In group 4, there were 33 normal-FDG-uptake sites (average SUV was 1.102 ± 0.141), The SUVs showed significant difference among the four groups(F = 678.909, P = 0.000). There were also significant difference found between the normal-FDG-uptake group and the high-FDG-uptake groups(P = 0.000, 0.000, 0.001, respectively). Conclusion:Different degrees of ^18F-FDG uptake in active large atherosclerotic plaque were shown in different stages of atherosclerotic plaque formation. The soft plaque had the highest FDG uptake in this study. This suggested that ^18F- FDG PET/CT imaging may be of great potential value in early diagnosis and monitoring of vulnerable soft plaque in atherosclerotic lesions. 展开更多
关键词 fluorine-18-2-fluoro-2-deoxy-D-glucose positron-emission tomography computerized tomography ATHEROSCLEROSIS vulnerable plaque
下载PDF
Multi-slice computerized tomography critical role in transcatheter aortic valve implantation plan: Review of current literature
20
作者 Edward Koifman Ashraf Hamdan 《World Journal of Hypertension》 2015年第3期107-114,共8页
Transcatheter aortic valve implantation(TAVI) has been shown in improve outcome of severe aortic stenosis(AS) patients, deemed surgical high-risk or inoperable, and has grown popular in the past decade. The procedure ... Transcatheter aortic valve implantation(TAVI) has been shown in improve outcome of severe aortic stenosis(AS) patients, deemed surgical high-risk or inoperable, and has grown popular in the past decade. The procedure requires accurate prior planning, and demands an integration of a "Heart Team" consisted from cardiac surgeons, interventional cardiologists, and imaging experts. The role of cardiac imaging and especially multi-slice computerized tomography(MSCT) has been a mainstay of pre-evaluation of severe AS patients that allows to accurately depict and size the cardiac and vascular structures, and has become the primary tool for procedural planning. This article is aimed to evaluate current uses of MSCT in severe AS patients undergoing TAVI, delineate the various measurements derived from this modality and review current literature regarding it's advantages over other techniques. 展开更多
关键词 TRANSCATHETER AORTIC valve implantation Multi-slice computerized tomography AORTIC annular SIZING Vascular access
下载PDF