X-ray mass absorption coefficients play an important role in the accu racy of any XRF intensity calculation. It is necessary to determine the proper schemes for providing satisfying values μ/ρ. In this work we exami...X-ray mass absorption coefficients play an important role in the accu racy of any XRF intensity calculation. It is necessary to determine the proper schemes for providing satisfying values μ/ρ. In this work we examined and compared various schemes. A program based on the existing schemes to provide more accurate and convenient μ/ρ values was then introduced. The results from the program appears to be tolerable.展开更多
The full-spectrum least-squares(FSLS) method is introduced to perform quantitative energy-dispersive X-ray fluorescence analysis for unknown solid samples.Based on the conventional least-squares principle, this spectr...The full-spectrum least-squares(FSLS) method is introduced to perform quantitative energy-dispersive X-ray fluorescence analysis for unknown solid samples.Based on the conventional least-squares principle, this spectrum evaluation method is able to obtain the background-corrected and interference-free net peaks, which is significant for quantization analyses. A variety of analytical parameters and functions to describe the features of the fluorescence spectra of pure elements are used and established, such as the mass absorption coefficient, the Gi factor, and fundamental fluorescence formulas. The FSLS iterative program was compiled in the C language. The content of each component should reach the convergence criterion at the end of the calculations. After a basic theory analysis and experimental preparation, 13 national standard soil samples were detected using a spectrometer to test the feasibility of using the algorithm. The results show that the calculated contents of Ti, Fe, Ni, Cu, and Zn have the same changing tendency as the corresponding standard content in the 13 reference samples. Accuracies of 0.35% and 14.03% are obtained, respectively, for Fe and Ti, whose standard concentrations are 8.82% and 0.578%, respectively. However, the calculated results of trace elements (only tens of lg/g) deviate from the standard values. This may be because of measurement accuracy and mutual effects between the elements.展开更多
A new method for quantitative X-ray diffraction phase analysis of a powder misture has been developed according to Popovic's doping method. The weight fraction of amorphous material in the analysed sample is obtai...A new method for quantitative X-ray diffraction phase analysis of a powder misture has been developed according to Popovic's doping method. The weight fraction of amorphous material in the analysed sample is obtained. For a multicomponent system in which (n-2) pure phases are added into an n-phase compnent sample and theweight fractions of all n phases can be determined by the method. The test results of confirmation agree well with the theory.展开更多
文摘X-ray mass absorption coefficients play an important role in the accu racy of any XRF intensity calculation. It is necessary to determine the proper schemes for providing satisfying values μ/ρ. In this work we examined and compared various schemes. A program based on the existing schemes to provide more accurate and convenient μ/ρ values was then introduced. The results from the program appears to be tolerable.
基金supported by the National Key R&D Project of China(No.2017YFC0602100)the National Natural Science Foundation of China(No.41774147)Sichuan Science and Technology Support Program(No.2015GZ0272)
文摘The full-spectrum least-squares(FSLS) method is introduced to perform quantitative energy-dispersive X-ray fluorescence analysis for unknown solid samples.Based on the conventional least-squares principle, this spectrum evaluation method is able to obtain the background-corrected and interference-free net peaks, which is significant for quantization analyses. A variety of analytical parameters and functions to describe the features of the fluorescence spectra of pure elements are used and established, such as the mass absorption coefficient, the Gi factor, and fundamental fluorescence formulas. The FSLS iterative program was compiled in the C language. The content of each component should reach the convergence criterion at the end of the calculations. After a basic theory analysis and experimental preparation, 13 national standard soil samples were detected using a spectrometer to test the feasibility of using the algorithm. The results show that the calculated contents of Ti, Fe, Ni, Cu, and Zn have the same changing tendency as the corresponding standard content in the 13 reference samples. Accuracies of 0.35% and 14.03% are obtained, respectively, for Fe and Ti, whose standard concentrations are 8.82% and 0.578%, respectively. However, the calculated results of trace elements (only tens of lg/g) deviate from the standard values. This may be because of measurement accuracy and mutual effects between the elements.
文摘A new method for quantitative X-ray diffraction phase analysis of a powder misture has been developed according to Popovic's doping method. The weight fraction of amorphous material in the analysed sample is obtained. For a multicomponent system in which (n-2) pure phases are added into an n-phase compnent sample and theweight fractions of all n phases can be determined by the method. The test results of confirmation agree well with the theory.