A TOTAL CONTENT X—RAY FLUORESCENCE METHOD FOR COPPER PROSPECTING
1
作者 周四春 谢庭周 葛良全 《Nuclear Science and Techniques》 SCIE CAS CSCD 1992年第3期191-195,共5页
A new method is proposed to prospect copper deposits with portable XRF analyzer. The method is based on the close relation between Cu and the chalcophile elements or some other elements in the geochemical anomalies of... A new method is proposed to prospect copper deposits with portable XRF analyzer. The method is based on the close relation between Cu and the chalcophile elements or some other elements in the geochemical anomalies of a Cu deposit. Applications of the technique in Northeast China are presented. 展开更多
关键词 Portable x-ray fluorescence analyzerS Total content x-ray fluorescence method PROSPECTING for COPPER DEPOSITS
下载PDF
Quantification of Silicon (SI) and Silicon Dioxide (SiO2) from the Nafud Desert-Al-Qassim Region, Kingdom of Saudi Arabia Using XRD Analysis
2
作者 Nagwa Ibrahim Mohamed 《Advances in Materials Physics and Chemistry》 CAS 2024年第5期67-75,共9页
This research was conducted in the Qassim region, Kingdom of Saudi Arabia. The goal of this research is to determine the percentage of silicon in the Rub al-Khali desert. Samples were collected from four cities locate... This research was conducted in the Qassim region, Kingdom of Saudi Arabia. The goal of this research is to determine the percentage of silicon in the Rub al-Khali desert. Samples were collected from four cities located in the Al-Qassim Region of Saudi Arabia (Uyun Al-Jawa, Al-Fuwailiq, Al-Sulaibiya, and Al-Qawara), from three distinct depths (the earth’s surface, 50 cm, and 100 cm). The percentages of silicon in these places vary between the highest value for silicon dioxide, which is 74.47 m/m%, and 34.8 m/m% for silicon in Al-Qawara city at a depth of 100 cm. We used an x-ray fluorescence (XRF) instrument to evaluate the samples. There are high percentage of both silica and silicon in the Nafud desert. Studies have shown that these ratios can help investors benefit from an element of Silicon and silicon dioxide, so the sands of the Nafud desert is sufficient for extracting Silicon and silica in huge quantities. This may transform the Kingdom into a leading country in the global computer technology industry that depends on silicon extracted from the desert sands, the most important of which are microcomputer data processing devices. 展开更多
关键词 Silica Sand Dispersive x-ray fluorescence (EDXRF) analyzer Solar Cells Nafud Desert Al-Qawwarh
下载PDF
X-Supreme 8000型X射线荧光定硫仪硫含量测定方法探讨
3
作者 侯慧玉 李广益 江建英 《石油化工安全环保技术》 CAS 2023年第5期46-49,I0003,共5页
主要对X-Supreme 8000型X射线荧光定硫仪准确测定原油、汽柴油原料油、石脑油、柴油产品、航煤产品等油品硫含量的分析方法进行试验探讨,优化分析条件,根据硫含量的大小不同,分别建立不同的工作曲线,相关系数均大于0.999。实验结果表明... 主要对X-Supreme 8000型X射线荧光定硫仪准确测定原油、汽柴油原料油、石脑油、柴油产品、航煤产品等油品硫含量的分析方法进行试验探讨,优化分析条件,根据硫含量的大小不同,分别建立不同的工作曲线,相关系数均大于0.999。实验结果表明:在选定的测定条件下,X-Supreme 8000型X射线荧光定硫仪能准确测定原油、汽柴油原料油、石脑油、柴油产品、航煤产品等油品中的硫含量,测定结果的重复性和再现性均能够满足现行有效的方法 GB/T 17040—2019的要求[1]。 展开更多
关键词 X射线荧光定硫仪 X-Supreme 8000 硫含量
下载PDF
石墨矿中硫含量测定的研究 被引量:1
4
作者 朱萌 《云南化工》 CAS 2023年第1期81-84,共4页
硫在石墨矿中属于有害物质,硫含量的高低会影响石墨矿的品位。石墨矿样品在微机库仑测硫仪中经高温燃烧分解,电解池电解所消耗的电量可以得出硫含量。利用标准加入的方法做方法的回收试验,测得的回收率在92%~100%之间,微机库仑法的硫含... 硫在石墨矿中属于有害物质,硫含量的高低会影响石墨矿的品位。石墨矿样品在微机库仑测硫仪中经高温燃烧分解,电解池电解所消耗的电量可以得出硫含量。利用标准加入的方法做方法的回收试验,测得的回收率在92%~100%之间,微机库仑法的硫含量测定值与燃烧碘量法和X射线荧光光谱法测定结果相符。同时对影响微机库仑测硫结果的因素进行了分析,对于石墨矿中硫含量的测定具有重要的意义。 展开更多
关键词 石墨矿 硫含量 微机库仑测硫仪 燃烧碘量法 X射线荧光光谱法
下载PDF
燃料油中硫含量的在线检测技术
5
作者 孙伟峰 《仪器仪表用户》 2023年第2期31-34,共4页
面对日益增长的环境污染带来的挑战,尤其是车用燃料油带来硫化物颗粒导致PM2.5居高不下问题,国家相关部门发布了新的国家车用汽油标准(即国五标准),要求从2017年1月1日起,在中国市场上销售的车用汽油含硫量不能高于10ppm。如何贯彻新的... 面对日益增长的环境污染带来的挑战,尤其是车用燃料油带来硫化物颗粒导致PM2.5居高不下问题,国家相关部门发布了新的国家车用汽油标准(即国五标准),要求从2017年1月1日起,在中国市场上销售的车用汽油含硫量不能高于10ppm。如何贯彻新的燃油标准,确保所提供油品质量,并实时监测脱硫装置、在线调和装置的运行效率,成为众多炼油企业的难题。采用脉冲紫外荧光技术的在线总硫分析仪为人们提供了可靠的选择。希望通过对新标准的解读,使人们了解可靠总硫检测手段,对在线总硫分析仪有一个清晰的认知以及在炼油企业中的成功应用,为过程控制和产品质量提供更好的解决方案。 展开更多
关键词 车用汽油标准 脉冲紫外荧光法 在线总硫分析仪
下载PDF
X射线荧光光谱法石油产品硫含量分析仪校准方法 被引量:2
6
作者 李向召 黄志凡 +1 位作者 何小青 黄俊华 《化学分析计量》 CAS 2011年第1期83-84,共2页
探讨X射线荧光光谱法石油产品硫含量分析仪的校准方法,确定了标准曲线相关系数、示值误差、仪器测量重复性、仪器稳定性校准指标。该方法合理、简便易行,各项指标评价结果基本符合仪器的设计性能和实际工作测试要求。
关键词 X射线荧光光谱 硫分析仪 校准方法 性能评价
下载PDF
紫外荧光二氧化硫分析仪中滤光器的优化 被引量:1
7
作者 杜伟 何振江 韩鹏 《半导体光电》 CAS CSCD 北大核心 2013年第4期702-705,共4页
为了获得紫外荧光二氧化硫分析仪中所需的213.4nm激发光,研究了采用色散型紫外滤光器的参数优化,系统分析了装置中入射和出射狭缝对输出光的强度、稳定性及光谱纯度的影响,探讨了其物理机制,并通过实验得到了该装置中的最优参数为入射... 为了获得紫外荧光二氧化硫分析仪中所需的213.4nm激发光,研究了采用色散型紫外滤光器的参数优化,系统分析了装置中入射和出射狭缝对输出光的强度、稳定性及光谱纯度的影响,探讨了其物理机制,并通过实验得到了该装置中的最优参数为入射狭缝宽度50μm,出射狭缝宽度40μm。该结果对于提高仪器的准确性、灵敏度及长期稳定性等性能参数有重要意义。 展开更多
关键词 紫外荧光 二氧化硫分析仪 紫外滤光器
下载PDF
基于ARM11的大气痕量硫检测仪 被引量:1
8
作者 白雪美 唐慧强 周继威 《仪表技术与传感器》 CSCD 北大核心 2017年第7期27-28,31,共3页
利用紫外荧光法测硫原理,设计了一款基于ARM11和WinCE6.0实时操作系统的新型嵌入式硫检测仪。硬件电路主要包括高压电源模块、信号采集和放大电路、模数转换电路、温度气体流量控制电路以及串口通信电路。ARM11微处理器和WinCE6.0操作... 利用紫外荧光法测硫原理,设计了一款基于ARM11和WinCE6.0实时操作系统的新型嵌入式硫检测仪。硬件电路主要包括高压电源模块、信号采集和放大电路、模数转换电路、温度气体流量控制电路以及串口通信电路。ARM11微处理器和WinCE6.0操作系统提供上位机操作界面,通过对检测数据进行分析处理,实现了在精度和重复性上的较大改善,能够完成0~200 mg/m^3的硫含量检测。 展开更多
关键词 嵌入式 硫检测仪 紫外荧光法 ARM11
下载PDF
Sulfur speciation and bioaccumulation in camphor tree leaves as atmospheric sulfur indicator analyzed by synchrotron radiation XRF and XANES 被引量:9
9
作者 Jianrong Zeng Guilin Zhang +5 位作者 Liangman Bao Shilei Long Mingguang Tan Yan Li Chenyan Ma Yidong Zhao 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2013年第3期605-612,共8页
Analyzing and understanding the effects of ambient pollution on plants is getting more and more attention as a topic of environmental biology.A method based on synchrotron radiation X-ray fluorescence and X-ray absorp... Analyzing and understanding the effects of ambient pollution on plants is getting more and more attention as a topic of environmental biology.A method based on synchrotron radiation X-ray fluorescence and X-ray absorption near edge structure spectroscopy was established to analyze the sulfur concentration and speciation in mature camphor tree leaves (CTLs),which were sampled from 5 local fields in Shanghai,China.Annual SO2 concentration,SO42-concentration in atmospheric particulate,SO42-and sulfur concentration in soil were also analyzed to explore the relationship between ambient sulfur sources and the sulfur nutrient cycling in CTLs.Total sulfur concentration in mature camphor tree leaves was 766-1704 mg/kg.The mainly detected sulfur states and their corresponding compounds were +6 (sulfate,include inorganic sulfate and organic sulfate),+5.2 (sulfonate),+2.2 (suloxides),+0.6 (thiols and thiothers),+0.2 (organic sulfides).Total sulfur concentration was strongly correlated with sulfate proportion with a linear correlation coefficient up to 0.977,which suggested that sulfur accumulated in CTLs as sulfate form.Reduced sulfur compounds (organic sulfides,thiols,thioethers,sulfoxide and sulfonate) assimilation was sufficed to meet the nutrient requirement for growth at a balanced level around 526 mg/kg.The sulfate accumulation mainly caused by atmospheric sulfur pollution such as SO2 and airborne sulfate particulate instead of soil contamination.From urban to suburb place,sulfate in mature CTLs decreased as the atmospheric sulfur pollution reduced,but a dramatic increase presented near the seashore,where the marine sulfate emission and maritime activity pollution were significant.The sulfur concentration and speciation in mature CTLs effectively represented the long-term biological accumulation of atmospheric sulfur pollution in local environment. 展开更多
关键词 synchrotron radiation x-ray fluorescence x-ray absorption near edge structure sulfur speciation sulfur bioaccumulation camphor tree leaves
原文传递
紫外荧光分析仪在天然气总硫分析中的应用 被引量:6
10
作者 陈忠仕 《石油化工自动化》 CAS 2015年第2期47-50,共4页
天然气中总硫质量分数是装置工艺控制的关键指标,是影响生产装置安全、稳定、长效运行的重要参数。介绍了天然气总硫在线分析方法和比选情况,阐述了紫外荧光法分析仪的测量原理、构成和性能指标,对分析仪系统的设计原则、设计方案和系... 天然气中总硫质量分数是装置工艺控制的关键指标,是影响生产装置安全、稳定、长效运行的重要参数。介绍了天然气总硫在线分析方法和比选情况,阐述了紫外荧光法分析仪的测量原理、构成和性能指标,对分析仪系统的设计原则、设计方案和系统各组成部分、现场应用情况、存在的问题进行了详细说明。 展开更多
关键词 总硫分析 紫外荧光分析法 激发态 在线分析仪系统 四流路切换
下载PDF
Rapid Growth of Pentaerythritol Crystal 被引量:1
11
作者 步欢欢 庄欣欣 +1 位作者 苏根博 贺友平 《Chinese Journal of Structural Chemistry》 SCIE CAS CSCD 2011年第1期67-70,共4页
Pentaerythritol(PET) crystal has been grown rapidly from the solution with sulfuric acid as the additive. The growth rate of PET crystal in prismatic shape exceeds 1.5 mm/day and crystallization size is 55×55&#... Pentaerythritol(PET) crystal has been grown rapidly from the solution with sulfuric acid as the additive. The growth rate of PET crystal in prismatic shape exceeds 1.5 mm/day and crystallization size is 55×55×50 mm^3. X-ray diffraction analysis was used to confirm the structure integrity. The diffraction efficiency of rapid-grown crystal was characterized as effective as that of normal growth. 展开更多
关键词 pentaerythritol x-ray analyzer crystal single-crystal diffraction x-ray fluorescence spectrum
下载PDF
紫外荧光测硫仪在LPG总硫含量分析中的应用研究 被引量:2
12
作者 张凤利 《低温与特气》 CAS 2014年第3期40-43,共4页
建立了紫外荧光法测定液化石油气中总硫含量的方法,从检测限、线性、重复性、再现性四方面考察了该方法的可行性和准确性。通过实验表明,紫外荧光法测定液化石油气中的总硫含量可满足国家标准方法要求,而且紫外荧光测硫仪较微库仑仪分... 建立了紫外荧光法测定液化石油气中总硫含量的方法,从检测限、线性、重复性、再现性四方面考察了该方法的可行性和准确性。通过实验表明,紫外荧光法测定液化石油气中的总硫含量可满足国家标准方法要求,而且紫外荧光测硫仪较微库仑仪分析效能优势明显。 展开更多
关键词 紫外荧光测硫仪 微库仑仪 总硫 液化石油气(LPG)
下载PDF
基于ZEMAX的二氧化硫分析仪光学设计 被引量:1
13
作者 李洪刚 吴岩磊 《天津科技》 2019年第7期54-56,共3页
鉴于二氧化硫分析仪中国标推荐的分析方法为紫外荧光法,根据此原理对两种光路进行了光学设计,并在ZEMAX中进行仿真和优化,结果显示:光路1的最终能量百分比为49%,光路2为9%;光路1的PMT位置光束半径为2.738mm,光路2为1.291mm。
关键词 二氧化硫分析仪 ZEMAX 光学设计 紫外荧光法
下载PDF
硫含量在线检测方法及在油品升级装置中的设计与应用
14
作者 文涛 《仪器仪表用户》 2016年第9期57-61,共5页
本文简述了电量法、波长色散X射线荧光光谱法、单波长色散X射线荧光光谱法及紫外荧光法等目前国标允许的硫含量检测方法。结合汽油加氢脱硫装置的应用,着重论述了紫外荧光在线总硫分析仪的测量原理、系统结构,并对使用过程中的故障及解... 本文简述了电量法、波长色散X射线荧光光谱法、单波长色散X射线荧光光谱法及紫外荧光法等目前国标允许的硫含量检测方法。结合汽油加氢脱硫装置的应用,着重论述了紫外荧光在线总硫分析仪的测量原理、系统结构,并对使用过程中的故障及解决方法进行了讨论。 展开更多
关键词 在线总硫分析仪 紫外荧光 汽油加氢
下载PDF
SOLA Ⅱ总硫分析仪在柴油加氢装置中的应用
15
作者 韩梅 李雪梅 +3 位作者 杜星 雷荣获 董波 康华 《化工自动化及仪表》 CAS 2018年第1期23-25,61,共4页
介绍了SOLA Ⅱ总硫分析仪的组成和原理,将该分析仪应用于庆阳石化公司年产160万吨柴油加氢装置,对分析仪在使用过程中出现的故障进行了分析和改造。
关键词 SOLA Ⅱ总硫分析仪 紫外荧光 精制柴油 总硫含量 在线分析
下载PDF
微库仑法与紫外荧光法测定煤化工产品中总硫含量的对比
16
作者 麻丽娟 白永伟 《煤炭加工与综合利用》 CAS 2018年第12期31-34,41,共5页
阐述了测定煤化工产品中总硫的两种不同方法,即紫外荧光法和微库仑法。通过对两种方法的原理,实验方法,样品测定的步骤及精密度等方面进行比较,结果表明紫外荧光法操作更简单、更环保、更高效,可用于煤化工产品中总硫含量的测定。
关键词 煤化工 紫外荧光法 微库仑法 硫分析器
下载PDF
仪器分析法测定萤石球中氟化钙含量
17
作者 于辉 曹建虎 +1 位作者 高伟伟 任新桃 《物理测试》 CAS 2022年第6期30-32,共3页
应用仪器法测定莹石球中氟化钙含量,以缩短检测时间,提高工作效率。试验选用萤石标样、石灰石标样,采用熔融法制片X射线荧光光谱法测定总钙、氧化镁含量;用碳硫仪测定总碳含量,将总碳含量减去碳酸镁中碳含量得到碳酸钙中碳含量,换算得... 应用仪器法测定莹石球中氟化钙含量,以缩短检测时间,提高工作效率。试验选用萤石标样、石灰石标样,采用熔融法制片X射线荧光光谱法测定总钙、氧化镁含量;用碳硫仪测定总碳含量,将总碳含量减去碳酸镁中碳含量得到碳酸钙中碳含量,换算得氟化钙的含量。方法精密度好,相对标准偏差(RSD)为0.35%;方法准确度高,测定值与化学法测定值基本相符,能够满足生产需要。 展开更多
关键词 X射线荧光光谱法 总钙 氧化镁 碳硫仪