期刊文献+
共找到107篇文章
< 1 2 6 >
每页显示 20 50 100
Effect of laser focus in two-color synthesized waveform on generation of soft x-ray high harmonics
1
作者 陈炎波 李保昌 +3 位作者 李胥红 唐翔宇 张弛 金成 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第1期319-326,共8页
Synthesis of multi-color laser pulses has been developed as a promising way to improve low conversion efficiency of high-order harmonic generation(HHG). Here we systematically study the effect of laser focus in a two-... Synthesis of multi-color laser pulses has been developed as a promising way to improve low conversion efficiency of high-order harmonic generation(HHG). Here we systematically study the effect of laser focus in a two-color waveform on generation of macroscopic HHG in soft x-rays. We find that the dependence of HHG yields on laser focus at low or high gas pressure is sensitive to the characteristics of single-atom harmonic response, in which “short”-or “long”-trajectory emissions can be selectively controlled by changing the waveform of two-color synthesized laser pulse. We uncover the phase-matching mechanism of HHG in the gas medium by examining the propagation of the two-color waveform and the evolution of time-frequency emissions of high-harmonic field. We further reveal that the nonlinear effects, such as geometric phase, atomic dispersion, and plasma defocusing, are responsible for modification of two-color waveform upon propagation. This work can be used to find better macroscopic conditions for generating soft x-ray HHG by employing two-color optimized waveforms. 展开更多
关键词 high-order harmonic generation two-color waveform soft x-rays macroscopic propagation laser focus
下载PDF
Polycapillary X-ray lens for the secondary focusing Beijing synchrotron radiation source 被引量:3
2
作者 李玉德 林晓燕 +4 位作者 刘世岗 何金龙 郭非 孙天希 刘鹏 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第4期248-252,共5页
According to intensity distribution of the synchrotron radiation source focused by a toroidal mirror at the Beijing synchrotron radiation biological macromolecule station, theoretical modeling of the Beijing synchrotr... According to intensity distribution of the synchrotron radiation source focused by a toroidal mirror at the Beijing synchrotron radiation biological macromolecule station, theoretical modeling of the Beijing synchrotron radiation source is developed for capillary optics. Using this theoretical modeling, the influences of the configuration curve of the polycapillary X-ray lens on transmission efficiency and working distance are analyzed. The experimental results of the transmission efficiency and working distance at the biological macromolecule station are in good agreement with the theoretical results. 展开更多
关键词 Beijing synchrotron radiation facility polycapillary x-ray lens secondary focusing
下载PDF
Properties of focused Laguerre–Gaussian beam propagating in anisotropic ocean turbulence
3
作者 王新光 马洋斌 +3 位作者 袁邱杰 陈伟 王乐 赵生妹 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第2期386-393,共8页
We analyze the properties of a focused Laguerre–Gaussian(LG)beam propagating through anisotropic ocean turbulence based on the Huygens–Fresnel principle.Under the Rytov approximation theory,we derive the analytical ... We analyze the properties of a focused Laguerre–Gaussian(LG)beam propagating through anisotropic ocean turbulence based on the Huygens–Fresnel principle.Under the Rytov approximation theory,we derive the analytical formula of the channel capacity of the focused LG beam in the anisotropic ocean turbulence,and analyze the relationship between the capacity and the light source parameters as well as the turbulent ocean parameters.It is found that the focusing mirror can greatly enhance the channel capacity of the system at the geometric focal plane in oceanic turbulence.The results also demonstrate that the communication link can obtain high channel capacity by adopting longer beam wavelength,greater initial beam waist radius,and larger number of transmission channels.Further,the capacity of the system increases with the decrease of the mean squared temperature dissipation rate,temperature-salinity contribution ratio and turbulence outer scale factor,and with the increase of the kinetic energy dissipation rate per unit mass of fluid,turbulence inner scale factor and anisotropy factor.Compared to a Hankel–Bessel beam with diffraction-free characteristics and unfocused LG beam,the focused LG beam shows superior anti-turbulence interference properties,which provide a theoretical reference for research and development of underwater optical communication links using focused LG beams. 展开更多
关键词 vortex beam orbital angular momentum focusing mirror anisotropic turbulence
下载PDF
The Study Internal Structure of the Annual Layers in Lake Sediments Using Synchrotron Radiation with X-ray Focusing Optics
4
作者 Fedor DARIN Ivan KALUGIN +1 位作者 Andrey DARIN Yakov RAKSHUN 《Acta Geologica Sinica(English Edition)》 SCIE CAS CSCD 2014年第S1期5-6,共2页
1 Introduction Annually laminated(varve)sedimentary deposits are considered as one of the most important archives,since they offer precise temporal information(years)in combination with high time resolutions.Bottom se... 1 Introduction Annually laminated(varve)sedimentary deposits are considered as one of the most important archives,since they offer precise temporal information(years)in combination with high time resolutions.Bottom sediments of the lakes contain detailed geochemical information on 展开更多
关键词 VARVE .synchrotron radiation scanning X_ray fluorescence microanalysis focusing x-ray optics.
下载PDF
Focusing high-energy x-rays by a P MMA compound x-ray lens on Beijing synchrotron radiation facility
5
作者 乐孜纯 梁静秋 +6 位作者 董文 朱佩平 彭良强 王维彪 黄万霞 袁清习 王寯越 《Chinese Physics B》 SCIE EI CAS CSCD 2007年第4期984-988,共5页
The x-ray compound lens is a novel refractive x-ray optical device. This paper reports the authors' recent research on a polymethyl methacrylate (PMMA) compound x-ray lens. Firstly the designing and LIGA fabricatio... The x-ray compound lens is a novel refractive x-ray optical device. This paper reports the authors' recent research on a polymethyl methacrylate (PMMA) compound x-ray lens. Firstly the designing and LIGA fabrication process for the PMMA compound x-ray lens are briefly described. Then, a method for theoretical analysis, as well as the experimental system for measurement is also introduced. Finally, the focusing spots for 8keV monochromatic x-rays by the PMMA compound x-ray lens are measured and analysed. According to the experimental results, it is concluded that the PMMA compound x-ray lens promises a good focusing performance under the high-energy x-rays. 展开更多
关键词 PMMA compound x-ray lens focusing performance Beijing synchrotron radiation facility (BSRF)
下载PDF
In-Orbit Calibration and Data Analysis of China's First Grazing Incidence Focusing X-Ray Pulsar Telescope
6
作者 LV Zhengxin MEI Zhiwu +10 位作者 DENG Loulou LI Liansheng SHI Yongqiang CHEN Jianwu ZUO Fuchang LIU Ke WANG Chunyu ZHANG Jianfu MO Yanan WANG Shuyan ZHAO Yuan 《Aerospace China》 2017年第3期3-10,共8页
The grazing incidence focusing X-ray pulsar telescope(iFXPT), as the main payload of the X-ray Pulsar Navigation Test Satellite(XPNAV-1), will have great significance on China's space scientific exploration and X-... The grazing incidence focusing X-ray pulsar telescope(iFXPT), as the main payload of the X-ray Pulsar Navigation Test Satellite(XPNAV-1), will have great significance on China's space scientific exploration and X-ray pulsar navigation. With PSR B0531+21(Crab Pulsar) as the observation target, the pulsar profile has been recovered based on the data obtained by iFXPT, realizing the main objective of "observing" PSR B0531+21 for the first time in China. This payload mainly consists of the Wolter-I X-ray optics, silicon drift detector, magnetic deflector, electronics, high-energy particle shield and high-stability structures. Currently, the iFXPT, with its good in-orbit performance, has obtained a considerable observation data. The effective area, sensitivity and energy response have been calibrated both on ground and in-orbit, demonstrating a high degree of consistency. Meanwhile, the in-orbit observation data and information for pulsar navigation has also been analyzed simultaneously. As a result, the feasibility of the exploration scheme and the performance of the telescope have been fully validated. 展开更多
关键词 x-ray pulsar navigation satellite focusing x-ray telescope in-orbit observation profile folding timing residual
下载PDF
A high quality surface finish grinding process to produce total reflection mirror for x-ray fluorescence analysis 被引量:3
7
作者 Hitoshi Ohmori Shinjiro Umezu +8 位作者 Yunji Kim Yoshihiro Uehara Hiroshi Kasuga Teruko Kato Nobuhide Itoh Syuhei Kurokawa Takayuki Kusumi Yugo Sugawara Shinsuke Kunimura 《International Journal of Extreme Manufacturing》 2020年第1期156-162,共7页
Total reflection x-ray fluorescence analysis is applied to trace element detection in liquid for effective environmental monitoring.This analytical approach requires x-ray total reflection mirrors.In order to achieve ... Total reflection x-ray fluorescence analysis is applied to trace element detection in liquid for effective environmental monitoring.This analytical approach requires x-ray total reflection mirrors.In order to achieve high sensitivity element detection,the mirrors require high surface quality for high x-ray reflectivity.Surface finishing for x-ray mirrors is typically conducted through a series of abrasive processes,such as grinding and polishing,and is thus time consuming.The purpose of this study is to streamline and enhance the surface finishing process based on unique high quality grinding techniques for the production of x-ray total reflection mirrors. 展开更多
关键词 GRINDING FINISHING x-ray mirror
下载PDF
Energy spectrum of multi-radiation of X-rays in a low energy Mather-type plasma focus device 被引量:1
8
作者 Farzin M.Aghamir Reza A.Behbahani 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第6期375-380,共6页
The multi-radiation of X-rays was investigated with special attention to their energy spectrum in a Mather-type plasma focus device (operated with argon gas). The analysis is based on the effect of anomalous resista... The multi-radiation of X-rays was investigated with special attention to their energy spectrum in a Mather-type plasma focus device (operated with argon gas). The analysis is based on the effect of anomalous resistances. To study the energy spectrum, a four-channel diode X-ray spectrometer was used along with a special set of filters. The filters were suitable for detection of medium range X-rays as well as hard X-rays with energy exceeding 30 keV. The results indicate that the anomalous resistivity effect during the post pinch phase may cause multi-radiation of X-rays with a total duration of 300 ± 50 ns. The significant contribution of Cu-Kα was due to the medium range X-rays, nonetheless, hard X-rays with energies greater than 15 keV also participate in the process. The total emitted X-ray energy in the forms of Cu-K and Cu-K/3 was around 0.14 ± 0.02 (J/Sr) and 0.04 ±0.01 (J/Sr), respectively. The total energy of the emitted hard X-ray (〉 15 keV) was around 0.12± 0.02 (J/Sr). 展开更多
关键词 Mather-type plasma focus device hard x-rays multi-radiation tube multiple voltage peaks anomalous resistances
下载PDF
Electron Temperature Measurement Using PIN Diodes as Detectors to Record the X-ray Pulses from a Low-Energy Mather-Type Plasma Focus
9
作者 M.Asif Amna Ikram 《Plasma Science and Technology》 SCIE EI CAS CSCD 2004年第2期2199-2203,共5页
In the experiment to determine the plasma electron temperature, a modifiedmultichannel PIN diodes assembly is used as detectors to record the X-ray pulses from a low-energyMather-type plasma focus device energized by ... In the experiment to determine the plasma electron temperature, a modifiedmultichannel PIN diodes assembly is used as detectors to record the X-ray pulses from a low-energyMather-type plasma focus device energized by a 32μF, 15 kV (3.6kJ) single capacitor, with deuteriumas a filling gas. The ratio of the integrated bremsstrahlung emission transmitting through foils tothe total incident flux as a function of foil thickness at various temperatures is obtained forfoil absorbers of material. Using 3 μm, 6 μm, 9 μm,12 μm,15 μm and 18 μm thick aluminiumabsorbers, the transmitted X-ray flux is detected. By comparing the experimental and theoreticalcurves through a computer program, the plasma electron temperature is determined. Results show thatthe deuterium focus plasma electron temperature is about 800 eV. 展开更多
关键词 plasma focus PIN diodes x-ray foil absorber thickness
下载PDF
Low Energy Plasma Focus as an Intense X-ray Source for Radiography
10
作者 S.Hussain M.Zakaullah +1 位作者 Shujaat Ali A.Waheed 《Plasma Science and Technology》 SCIE EI CAS CSCD 2004年第3期2296-2300,共5页
Study on X-ray emission from a low energy (1.8 kJ) plasma focus devicepowered by a 9 μF capacitor bank, charged at 20 kV and giving peak discharge current of about 175kA by using a lead-inserted copper-tapered anode ... Study on X-ray emission from a low energy (1.8 kJ) plasma focus devicepowered by a 9 μF capacitor bank, charged at 20 kV and giving peak discharge current of about 175kA by using a lead-inserted copper-tapered anode is reported. The X-ray yield in different energywindows is measured as a function of hydrogen filling pressure. The maximum yield in 4π-geometry isfound to be (27.3+-1.1) J and corresponding wall plug efficiency for X-ray generation is 1.52+-0.06%. X-ray emission, presumably due to bombarding activity of electrons in current sheath at theanode tip was dominant, which is confirmed by the pinhole images. The feasibility of the device asan intense X-ray source for radiography is demonstrated. 展开更多
关键词 plasma focus x-ray source RADIOGRAPHY
下载PDF
Investigation on the hydrodynamics of slab x-ray laser plasma by nonuiform line focused laser irradiation
11
作者 程涛 李英骏 +1 位作者 孟立民 李希波 《Chinese Physics B》 SCIE EI CAS CSCD 2011年第2期260-265,共6页
Based on the two-dimensional model, this paper compares the hydrodynamics of slab x-ray laser plasma produced by different nonuniform line focused irradiations. It finds that the average intensity and the duration of ... Based on the two-dimensional model, this paper compares the hydrodynamics of slab x-ray laser plasma produced by different nonuniform line focused irradiations. It finds that the average intensity and the duration of laser pulse and the overall shape of the intensity distribution in the focal line have different influences on the plasma. Calculations show that the evolution of temperature variation is more sensitive to the pulse duration and the electron density variation is more sensitive to the pulse intensity. Pulses with duration of 200 ps to 500 ps and with intensity of 0.2 TW/cm2 to 1.0 TW/cm2 are proved acceptable in slab x-ray lasers. 展开更多
关键词 PLASMA slab x-ray laser nonuniform line focused laser irradiation HYDRODYNAMICS
下载PDF
Focusing of Intense Laser via Parabolic Plasma Concave Surface
12
作者 周维民 谷渝秋 +4 位作者 吴凤娟 张智猛 单连强 曹磊峰 张保汉 《Plasma Science and Technology》 SCIE EI CAS CSCD 2015年第12期996-999,共4页
Since laser intensity plays an important role in laser plasma interactions,a method of increasing laser intensity- focusing of an intense laser via a parabolic plasma concave surface- is proposed and investigated by t... Since laser intensity plays an important role in laser plasma interactions,a method of increasing laser intensity- focusing of an intense laser via a parabolic plasma concave surface- is proposed and investigated by three-dimensional particle-in-cell simulations.The geometric focusing via a parabolic concave surface and the temporal compression of high harmonics increased the peak intensity of the laser pulse by about two orders of magnitude.Compared with the improvement via laser optics approaches,this scheme is much more economic and appropriate for most femtosecond laser facilities. 展开更多
关键词 harmonics focusing parabolic concave intense facilities incident optics mirror spots
下载PDF
Development of aperiodic multilayer mirrors operated at W-Lβline for plasma diagnostics application
13
作者 Ze‑Hua Yang Jing‑Tao Zhu +7 位作者 Zhong‑Liang Li Hong‑Xin Luo Shang‑Yu Si Yun‑Ping Zhu Li Zhao Kuan Ren Feng Wang Rong‑Qing Yi 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第11期77-84,共8页
Multilayer interference mirrors play a pivotal role in spectroscopic diagnostic systems,which probe electron temperature and density during inertial confinement fusion processes.In this study,aperiodic Mo/B_(4)C multi... Multilayer interference mirrors play a pivotal role in spectroscopic diagnostic systems,which probe electron temperature and density during inertial confinement fusion processes.In this study,aperiodic Mo/B_(4)C multilayer mirrors of varied thick-nesses were investigated for X-ray plasma diagnostics at the 9.67-keV W-Lβline.The thickness distribution of the aperiodic multilayers was designed using the first Bragg diffraction condition and then optimized through a simplex algorithm to realize a narrow bandwidth and consistent spectral response.To enhance spectral accuracy,further refinements were undertaken by matching the grazing incidence X-ray reflectivity data with actual structural parameters.X-ray reflectivity measurements from the SSRF synchrotron radiation facility on the optimized sample showed a reflectivity of 29.7±2.6%,flat-band range of 1.3 keV,and bandwidth of 1.7 keV,making it suitable for high-temperature plasma diagnostics.The study explored the potential of predicting the 9.67 keV reflectivity spectrum using the fitting data from the grazing incidence X-ray reflectivity curves at 8.05 keV.Additionally,the short-term thermal stability of an aperiodic multilayer was assessed using temperature-dependent in situ X-ray measurements.Shifts in the reflectivity spectrum during annealing were attributed to interdiffusion and interfacial relaxation.The research team recommends the aperiodic Mo/B_(4)C multilayer mirror for operations below 300℃. 展开更多
关键词 x-ray multilayer mirror Aperiodic multilayer Flat response Sputtering deposition Synchrotron radiation
下载PDF
临近空间激光雷达自调焦接收系统设计
14
作者 李英超 张庆 +2 位作者 刘壮 史浩东 付强 《红外与激光工程》 EI CSCD 北大核心 2024年第4期128-137,共10页
针对临近空间激光雷达所使用的离轴抛物面反射镜在低温下会发生形变导致反射光耦合进光纤时效率下降的问题,通过研究自调焦技术,设计了自动补偿激光雷达组件,用于抵消温度对系统的影响。利用有限元法分析了接收系统在热载荷作用下的变形... 针对临近空间激光雷达所使用的离轴抛物面反射镜在低温下会发生形变导致反射光耦合进光纤时效率下降的问题,通过研究自调焦技术,设计了自动补偿激光雷达组件,用于抵消温度对系统的影响。利用有限元法分析了接收系统在热载荷作用下的变形,获得镜面离散变形数据,使用Zernike多项式拟合镜面变形后的面形,通过光学设计软件模拟得出该激光雷达接收系统优化后的焦距变化与温度呈线性关系,经过光学设计软件确定补偿位置。使用温度自适应调整机构降低热变形带来的离焦量影响。分析结果表明,补偿后均方根半径从26.495μm下降至15.93μm,光斑半径减少39.9%,耦合效率提升至80%以上。 展开更多
关键词 离焦 调焦结构 有限元分析 耦合效率 离轴抛物面反射镜
下载PDF
Far-field vector-diffraction of off-axis parabolic mirror under oblique incidence 被引量:2
15
作者 曾夏辉 陈曦曜 《Chinese Physics B》 SCIE EI CAS CSCD 2020年第3期190-201,共12页
Based on a full vector-diffraction theory, a detailed theoretical study is carried out, aiming at providing a clear insight into the effects of different focusing and off-axis parabola parameters on far-field vector-d... Based on a full vector-diffraction theory, a detailed theoretical study is carried out, aiming at providing a clear insight into the effects of different focusing and off-axis parabola parameters on far-field vector-diffraction properties of an offaxis parabolic mirror in the presence of misalignments of the incoming beam. The physical origin of these effects is also explored. The results show that the far-field intensity profile is altered by the distortion-, coma-, and astigmatism-like aberrations, which are caused by oblique incidence rather than inherent aberrations for the off-axis configuration. The radius of 90% encircled energy also increases but does not change monotonically with incident beam size increasing, or rather,it first decreases and then increases. The focal shift strongly depends on the effective focal length and oblique incidence angle, but it is almost independent of the beam size, which affects the focusing spot patterns. The intensity distribution produces a higher astigmatic image with off-axis angle increasing. Coma-like aberration starts to become dominant with beam size increasing and results in larger curved propagation trajectory. The incident polarization also affects the intensity distribution. The variation in the Strehl ratio with oblique incidence angle strongly depends on the misalignment direction and beam size as well. In addition, we find that the difference in locus between the catacaustic and the diffraction focus in the meridian is small. But the locus of the sagittal foci is obviously different from the locus of the meridian foci and the catacaustic focus. Moreover, the peak intensity of the sagittal focus is maximum, and the ratio of the peak intensity to that in the meridian plane is approximately 1.5. Understanding these effects is valuable for assessing a practical focused intensity and describing the motion of charged particles under a strong electric field in ultraintense laser–matter interaction. 展开更多
关键词 laser beam focusing OFF-AXIS PARABOLIC mirror vector-diffraction theory oblique incidence
下载PDF
Ultrafast structural dynamics using time-resolved x-ray diffraction driven by relativistic laser pulses 被引量:2
16
作者 朱常青 谭军豪 +7 位作者 何雨航 王进光 李毅飞 鲁欣 李英骏 陈洁 陈黎明 张杰 《Chinese Physics B》 SCIE EI CAS CSCD 2021年第9期77-82,共6页
Based on a femtosecond laser plasma-induced hard x-ray source with a high laser pulse energy(>100 mJ)at 10 Hz repetition rate,we present a time-resolved x-ray diffraction system on an ultrafast time scale.The laser... Based on a femtosecond laser plasma-induced hard x-ray source with a high laser pulse energy(>100 mJ)at 10 Hz repetition rate,we present a time-resolved x-ray diffraction system on an ultrafast time scale.The laser intensity is at relativistic regime(2×10^(19)W/cm^(2)),which is essential for effectively generating K_(α)source in high-Z metal material.The produced copper K_(α)radiation yield reaches to 2.5×10^(8)photons/sr/shot.The multilayer mirrors are optimized for monochromatizating and two-dimensional beam shaping of Kαemission.Our experiment exhibits its ability of monitoring the transient structural changes in a thin film SrCoO_(2.5)crystal.It is demonstrated that this facility is a powerful tool to perform dynamic studies on samples and adaptable to the specific needs for different particular applications with high flexibility. 展开更多
关键词 ultrafast x-ray diffraction transient structural changes multilayer mirrors
下载PDF
Annealing treatment of focused gallium ion beam processing of SERS gold substrate 被引量:2
17
作者 Zhixiang Tao Wei Zhao +4 位作者 Shang Wang Boyu Zhao Rushuai Hua Ji Qin Zongwei Xu 《Nanotechnology and Precision Engineering》 CAS CSCD 2021年第4期37-44,共8页
Raman spectroscopy is a type of inelastic scattering spectroscopy that is widely used in determining and analyzing molecular structure.It also has a number of practical applications in evaluating food safety,medicine,... Raman spectroscopy is a type of inelastic scattering spectroscopy that is widely used in determining and analyzing molecular structure.It also has a number of practical applications in evaluating food safety,medicine,and forensics.The Raman spectral signal is weak,but the development of the surface-enhanced Raman scattering(SERS)technique has overcome this problem and led to further developments in Raman spectroscopy.This paper describes a fundamental study of the use of focused ion beam(FIB)direct writing for preparing gold substrates for SERS.Molecular dynamics and Monte Carlo simulation methods are used to investigate the damage induced by gallium ion implantation of a gold substrate.Based on characterization by x-ray photoelectron spectroscopy(XPS)and scanning electron microscopy,the mechanism by which ion implantation and annealing influence the damage induced by a gallium FIB is analyzed.After annealing at 350 XC,a mixture of metallic gallium,its oxide Ga2O3 conforming to the stoichiometric ratio,and its sub-stable oxide(Ga2Ox)in sub-stoichiometric ratio precipitated on the surface are detected by XPS.Annealing treatment can effectively reduce the effect of gallium ion implantation on a SERS substrate fabricated by FIB direct writing. 展开更多
关键词 Raman spectroscopy focused ion beam ANNEALING x-ray photoelectron spectroscopy
下载PDF
Present Status of EUV Interferometer Development at the Research Center for Soft X-ray Microscopy
18
作者 Masaki Yamamoto, Tadashi Hatano, Minaji Furudate (Research Center for Soft X-ray Microscopy, Institute of Multidisciplinary Research for Advanced Materials, Tohoku University, Japan) 《光学精密工程》 EI CAS CSCD 2001年第5期405-410,共6页
A new interferometer for extreme ultraviolet (EUV) radiation with a laser produced plasma (LPP) laboratory source is under construction. The LPP source is operated with a Sn solid rod target on which pulsed YAG laser ... A new interferometer for extreme ultraviolet (EUV) radiation with a laser produced plasma (LPP) laboratory source is under construction. The LPP source is operated with a Sn solid rod target on which pulsed YAG laser is focused to produce high temperature plasma emitting EUV radiation. The source is equipped with a newly designed debris stopper protecting a condenser multilayer mirror from the particle debris of the target. The condenser mirror focuses the light onto an EUV beam-splitter to form transmitted and reflected paths for producing interference fringes of a sharing type. The optical configuration is of a common path based on a triangular path type with a focusing at the beam-splitter, which is enabled to produce fringes by a low coherence radiation with a standard optical quality beam-splitter. The fringes are recorded by an imaging plate with pixels as small as 25μm. The dynamic range of linearity in detection of the EUV light was found to be more than 10 4 with sensitivity of 10 4 photons/pixel, enough for the purpose of interferogram recording, possibly with one laser shot. 展开更多
关键词 soft x-ray INTERFEROMETERS MULTILAYER mirrors FIGURE error imaging optics
下载PDF
Role of Ion Beam Irradiation and Annealing Efect on the Deposition of AlON Nanolayers by Using Plasma Focus Device
19
作者 I.A.KHAN R.S.RAWAT +4 位作者 R.VERMA G.MACHARAGA R.AHMAD Z.A.UMAR M.A.K.SHAHID 《Plasma Science and Technology》 SCIE EI CAS CSCD 2013年第11期1127-1135,共9页
AlON nanolayers are synthesized on Al substrate by the irradiation of energetic nitrogen ions using plasma focusing. Samples are exposed to multiple (5, 10, 15, 20 and 25) focus shots. Ion energy and ion number dens... AlON nanolayers are synthesized on Al substrate by the irradiation of energetic nitrogen ions using plasma focusing. Samples are exposed to multiple (5, 10, 15, 20 and 25) focus shots. Ion energy and ion number density range from 80 keV to 1.4 MeV and 5.6×10^19 m^- 3 to 1.3×10^19 m ^-3, respectively. Moreover, the effect of continuous annealing (473 K and 523 K) on an AlN surface layer synthesized with 25 focus shots is also examined. The main features of the X-ray diffraction (XRD) patterns with increasing focus shots are: (i) variation in the crystallinity of AlN along (111), (200) and (311) planes, (ii) increasing average crystallite size of AlN (111) plane, and (iii) stress relaxation observed in AlN (111) and (200) planes. The crystallinity of AlN surface layer is comparatively better at 473 K annealing temperature. A broadened diffraction peak related to an aluminium oxide phase showing weak crystallinity is observed for 15 focus shots while non-bounded oxides are present in all other deposited layers. Raman and Fourier transform infrared spectroscopy (FTIR) analysis confirm the presence of AlN and Al203 for the surface layer annealed at 473 K temperature. Raman analysis shows that the overlapping of AlN and Al2Oa results in the development of residual stresses. Scanning electron microscope (SEM) results demonstrate that the formation of rounded grains (range from 20 nm to 200 nm) and variations in their microstructures features depend on the increasing number of focus shots. Decomposition of larger clusters into smaller ones is observed. 展开更多
关键词 characterization XRD focus shots x-ray diffraction NUCLEATION surface layer
下载PDF
Development of a radiographic method for measuring the discrete spectrum of the electron beam from a plasma focus device
20
作者 Neda SHAMSIAN Babak SHIRANI BIDABADI Hosein PIRJAMADI 《Plasma Science and Technology》 SCIE EI CAS CSCD 2017年第7期26-33,共8页
An indirect method is proposed for measuring the relative energy spectrum of the pulsed electron beam of a plasma focus device. The Bremsstrahlung x-ray, generated by the collision of electrons against the anode surfa... An indirect method is proposed for measuring the relative energy spectrum of the pulsed electron beam of a plasma focus device. The Bremsstrahlung x-ray, generated by the collision of electrons against the anode surface, was measured behind lead filters with various thicknesses using a radiographic film system. A matrix equation was considered in order to explain the relation between the x-ray dose and the spectral amplitudes of the electron beam. The electron spectrum of the device was measured at 0.6 mbar argon and 22 kV charging voltage, in four discrete energy intervals extending up to 500 keV. The results of the experiments show that most of the electrons are emitted in the 125-375 keV energy range and the spectral amplitude becomes negligible beyond 375 keV. 展开更多
关键词 magnetized plasma plasma focus plasma diagnostics electron beam energyspectrum x-ray dosimetry
下载PDF
上一页 1 2 6 下一页 到第
使用帮助 返回顶部