BACKGROUND Early-stage breast cancer patients often lack specific clinical manifestations,making diagnosis difficult.Molybdenum target X-ray and magnetic resonance imaging(MRI)examinations both have their own advantag...BACKGROUND Early-stage breast cancer patients often lack specific clinical manifestations,making diagnosis difficult.Molybdenum target X-ray and magnetic resonance imaging(MRI)examinations both have their own advantages.Thus,a combined examination methodology may improve early breast cancer diagnoses.AIM To explore the combined diagnostic efficacy of molybdenum target X-ray and MRI examinations in breast cancer.METHODS Patients diagnosed with breast cancer at our hospital from March 2019 to April 2021 were recruited,as were the same number of patients during the same period with benign breast tumors.Both groups underwent molybdenum target X-ray and MRI examinations,and diagnoses were given based on each exam.The single(i.e.,X-ray or MRI)and combined(i.e.,using both methods)diagnoses were counted,and the MRI-related examination parameters(e.g.,T-wave peak,peak and early enhancement rates,and apparent diffusion coefficient)were compared between the groups.RESULTS In total,63 breast cancer patients and 63 benign breast tumor patients were recruited.MRI detected 53 breast cancer cases and 61 benign breast tumor cases.Molybdenum target X-ray detected 50 breast cancer cases and 60 benign breast tumor cases.The combined methodology detected 61 breast cancer cases and 61 benign breast tumor cases.The sensitivity(96.83%)and accuracy(96.83%)of the combined methodology were higher than single-method MRI(84.13%and 90.48%,respectively)and molybdenum target X-ray(79.37%and 87.30%,respectively)(P<0.05).The combined methodology specificity(96.83%)did not differ from singlemethod MRI(96.83%)or molybdenum target X-ray(95.24%)(P>0.05).The Twave peak(169.43±32.05)and apparent diffusion coefficient(1.01±0.23)were lower in the breast cancer group than in the benign tumor group(228.86±46.51 and 1.41±0.35,respectively).However,the peak enhancement rate(1.08±0.24)and early enhancement rate(1.07±0.26)were significantly higher in the breast cancer group than in the benign tumor group(0.83±0.19 and 0.75±0.19,respectively)(P<0.05).CONCLUSION Combined molybdenum target X-ray and MRI examinations for diagnosing breast cancer improved the diagnostic sensitivity and accuracy,minimizing the missedand misdiagnoses risks and promoting timely treatment intervention.展开更多
BACKGROUND Conventional plain X-ray images of rats,the most common animals used as degeneration models,exhibit unclear vertebral structure and blurry intervertebral disc spaces due to their small size,slender vertebra...BACKGROUND Conventional plain X-ray images of rats,the most common animals used as degeneration models,exhibit unclear vertebral structure and blurry intervertebral disc spaces due to their small size,slender vertebral bodies.AIM To apply molybdenum target X-ray photography in the evaluation of caudal intervertebral disc(IVD)degeneration in rat models.METHODS Two types of rat caudal IVD degeneration models(needle-punctured model and endplate-destructed model)were established,and their effectiveness was verified using nuclear magnetic resonance imaging.Molybdenum target inspection and routine plain X-ray were then performed on these models.Additionally,four observers were assigned to measure the intervertebral height of degenerated segments on molybdenum target plain X-ray images and routine plain X-ray images,respectively.The degeneration was evaluated and statistical analysis was subsequently conducted.RESULTS Nine rats in the needle-punctured model and 10 rats in the endplate-destructed model were effective.Compared with routine plain X-ray images,molybdenum target plain X-ray images showed higher clarity,stronger contrast,as well as clearer and more accurate structural development.The McNemar test confirmed that the difference was statistically significant(P=0.031).In the two models,the reliability of the intervertebral height measured by the four observers on routine plain X-ray images was poor(ICC<0.4),while the data obtained from the molybdenum target plain X-ray images were more reliable.CONCLUSIONMolybdenum target inspection can obtain clearer images and display fine calcification in the imaging evaluation of caudal IVD degeneration in rats,thus ensuring a more accurate evaluation of degeneration.展开更多
Laser-induced breakdown spectroscopy has been recognized as a significant tool for element diagnostics in plasma–wall interaction. In this work, a one-dimensional numerical model is developed to simulate the laser ab...Laser-induced breakdown spectroscopy has been recognized as a significant tool for element diagnostics in plasma–wall interaction. In this work, a one-dimensional numerical model is developed to simulate the laser ablation processes of a molybdenum(Mo) target in vacuum conditions. The thermal process of the interaction between the ns-pulse laser with wavelength of 1064 nm and the Mo target is described by the heat conduction equation. The plasma plume generation and expansion are described by Euler equations, in which the conservation of mass density, momentum and energy are included. Saha equations are used to describe the local thermal equilibrium of electrons, Mo atoms,Mo~+ and Mo^(2+) Plasma shielding and emission are all considered in this model. The mainly numerical results are divided into three parts, as listed below.Firstly, the rule of the plasma shielding effect varying with laser intensity is demonstrated quantitatively and fitted with the Nelder function. Secondly, the key parameters of plasma plume,such as the number density of species, the propagation velocity and the temperature, are all calculated in this model. The results indicate that the propagation velocity of the plume center increased with time in a general trend, however, one valley value appeared at about 20 ns due to the pressure gradient near the target surface leading to negative plasma velocity. Thirdly, the persistent lines of a Mo atom in the wavelength range from 300 nm to 600 nm are selected and the spectrum is calculated. Moreover, the temporal evolutions of Mo's spectral lines at wavelength of 550.6494 nm,553.3031 nm and 557.0444 nm are given and the results are compared with experimental data in this work.展开更多
The title complex was obtained by reactions of [Mo(CO)_3(MeCN)_3] with [CuBr(pySH)(PPh_3)_2]or directly with pySH and PPh_3. The latter method can be used to synthesize the corresponding tungsten complex [W_2(CO)_4(μ...The title complex was obtained by reactions of [Mo(CO)_3(MeCN)_3] with [CuBr(pySH)(PPh_3)_2]or directly with pySH and PPh_3. The latter method can be used to synthesize the corresponding tungsten complex [W_2(CO)_4(μ-pyS)_2(PPh_3)_2].The molecular structure of the title compound was determined by X-ray diffraction method.展开更多
基金Supported by Clinical Plateau Department,Shanghai Pudong New Area Health Construction Commission,No.PWYgy2018-04.
文摘BACKGROUND Early-stage breast cancer patients often lack specific clinical manifestations,making diagnosis difficult.Molybdenum target X-ray and magnetic resonance imaging(MRI)examinations both have their own advantages.Thus,a combined examination methodology may improve early breast cancer diagnoses.AIM To explore the combined diagnostic efficacy of molybdenum target X-ray and MRI examinations in breast cancer.METHODS Patients diagnosed with breast cancer at our hospital from March 2019 to April 2021 were recruited,as were the same number of patients during the same period with benign breast tumors.Both groups underwent molybdenum target X-ray and MRI examinations,and diagnoses were given based on each exam.The single(i.e.,X-ray or MRI)and combined(i.e.,using both methods)diagnoses were counted,and the MRI-related examination parameters(e.g.,T-wave peak,peak and early enhancement rates,and apparent diffusion coefficient)were compared between the groups.RESULTS In total,63 breast cancer patients and 63 benign breast tumor patients were recruited.MRI detected 53 breast cancer cases and 61 benign breast tumor cases.Molybdenum target X-ray detected 50 breast cancer cases and 60 benign breast tumor cases.The combined methodology detected 61 breast cancer cases and 61 benign breast tumor cases.The sensitivity(96.83%)and accuracy(96.83%)of the combined methodology were higher than single-method MRI(84.13%and 90.48%,respectively)and molybdenum target X-ray(79.37%and 87.30%,respectively)(P<0.05).The combined methodology specificity(96.83%)did not differ from singlemethod MRI(96.83%)or molybdenum target X-ray(95.24%)(P>0.05).The Twave peak(169.43±32.05)and apparent diffusion coefficient(1.01±0.23)were lower in the breast cancer group than in the benign tumor group(228.86±46.51 and 1.41±0.35,respectively).However,the peak enhancement rate(1.08±0.24)and early enhancement rate(1.07±0.26)were significantly higher in the breast cancer group than in the benign tumor group(0.83±0.19 and 0.75±0.19,respectively)(P<0.05).CONCLUSION Combined molybdenum target X-ray and MRI examinations for diagnosing breast cancer improved the diagnostic sensitivity and accuracy,minimizing the missedand misdiagnoses risks and promoting timely treatment intervention.
基金Supported by the National Key Research and Development Program of China,No.2017YFA0105404。
文摘BACKGROUND Conventional plain X-ray images of rats,the most common animals used as degeneration models,exhibit unclear vertebral structure and blurry intervertebral disc spaces due to their small size,slender vertebral bodies.AIM To apply molybdenum target X-ray photography in the evaluation of caudal intervertebral disc(IVD)degeneration in rat models.METHODS Two types of rat caudal IVD degeneration models(needle-punctured model and endplate-destructed model)were established,and their effectiveness was verified using nuclear magnetic resonance imaging.Molybdenum target inspection and routine plain X-ray were then performed on these models.Additionally,four observers were assigned to measure the intervertebral height of degenerated segments on molybdenum target plain X-ray images and routine plain X-ray images,respectively.The degeneration was evaluated and statistical analysis was subsequently conducted.RESULTS Nine rats in the needle-punctured model and 10 rats in the endplate-destructed model were effective.Compared with routine plain X-ray images,molybdenum target plain X-ray images showed higher clarity,stronger contrast,as well as clearer and more accurate structural development.The McNemar test confirmed that the difference was statistically significant(P=0.031).In the two models,the reliability of the intervertebral height measured by the four observers on routine plain X-ray images was poor(ICC<0.4),while the data obtained from the molybdenum target plain X-ray images were more reliable.CONCLUSIONMolybdenum target inspection can obtain clearer images and display fine calcification in the imaging evaluation of caudal IVD degeneration in rats,thus ensuring a more accurate evaluation of degeneration.
基金supported by National Magnetic Confinement Fusion Science Program of China (No.2013GB109005)National Natural Science Foundation of China (Nos.11475039,11605023)
文摘Laser-induced breakdown spectroscopy has been recognized as a significant tool for element diagnostics in plasma–wall interaction. In this work, a one-dimensional numerical model is developed to simulate the laser ablation processes of a molybdenum(Mo) target in vacuum conditions. The thermal process of the interaction between the ns-pulse laser with wavelength of 1064 nm and the Mo target is described by the heat conduction equation. The plasma plume generation and expansion are described by Euler equations, in which the conservation of mass density, momentum and energy are included. Saha equations are used to describe the local thermal equilibrium of electrons, Mo atoms,Mo~+ and Mo^(2+) Plasma shielding and emission are all considered in this model. The mainly numerical results are divided into three parts, as listed below.Firstly, the rule of the plasma shielding effect varying with laser intensity is demonstrated quantitatively and fitted with the Nelder function. Secondly, the key parameters of plasma plume,such as the number density of species, the propagation velocity and the temperature, are all calculated in this model. The results indicate that the propagation velocity of the plume center increased with time in a general trend, however, one valley value appeared at about 20 ns due to the pressure gradient near the target surface leading to negative plasma velocity. Thirdly, the persistent lines of a Mo atom in the wavelength range from 300 nm to 600 nm are selected and the spectrum is calculated. Moreover, the temporal evolutions of Mo's spectral lines at wavelength of 550.6494 nm,553.3031 nm and 557.0444 nm are given and the results are compared with experimental data in this work.
文摘The title complex was obtained by reactions of [Mo(CO)_3(MeCN)_3] with [CuBr(pySH)(PPh_3)_2]or directly with pySH and PPh_3. The latter method can be used to synthesize the corresponding tungsten complex [W_2(CO)_4(μ-pyS)_2(PPh_3)_2].The molecular structure of the title compound was determined by X-ray diffraction method.