An X-ray pinhole camera has been used to determine the transverse beam size and emittance on the diagnostic beam line of the storage ring at SSRF since2009.The performance of the beam size measurement is determined by...An X-ray pinhole camera has been used to determine the transverse beam size and emittance on the diagnostic beam line of the storage ring at SSRF since2009.The performance of the beam size measurement is determined by the width of the point spread function of the X-ray pinhole camera.Beam-based calibration was carried in 2012 out by varying the beam size at the source point and measuring the image size.However,this calibration method requires special beam conditions.In order to overcome this limitation,the pinhole camera was upgraded and an X-ray quasi-monochromator was installed.A novel experimental method was introduced by combining the pinhole camera with the monochromator to calibrate the point spread function.The point spread function can be accurately resolved by adjusting the angle of the monochromator and measuring the image size.The X-ray spectrum can also be obtained.In this work,the X-ray quasi-monochromator and the novel beam-based calibration method will be presented in detail.展开更多
Spatial resolution and image-processing methods for full-field X-ray fluorescence(FF-XRF)imaging using X-ray pinhole cameras were studied using Geant4simulations with different geometries and algorithms for image reco...Spatial resolution and image-processing methods for full-field X-ray fluorescence(FF-XRF)imaging using X-ray pinhole cameras were studied using Geant4simulations with different geometries and algorithms for image reconstruction.The main objectives were:(1)calculating the quantum efficiency curves of specific cameras,(2)studying the relationships between the spatial resolution and the pinhole diameter,magnification,and camera binning value,and(3)comparing image-processing methods for pinhole camera systems.Several results were obtained using a point and plane source as the X-ray fluorescence emitter and an array of 100×100 silicon pixel detectors as the X-ray camera.The quantum efficiency of a back-illuminated deep depletion(BI-DD)structure was above 30%for the XRF energies in the 0.8–9 keV range,with the maximum of 93.7%at 4 keV.The best spatial resolution of the pinhole camera was 24.7μm and 31.3 lp/mm when measured using the profile function of the point source,with the diameter of 20μm,magnification of 3.16,and camera bin of 1.A blind deconvolution algorithm with Gaussian filtering performed better than the Wiener filter and Richardson iterative methods on FF-XRF images,with the signal-to-noise ratio of 7.81 dB and improved signalto-noise ratio of 7.24 dB at the diameter of 120μm,magnification of 1.0,and camera bin of 1.展开更多
A pinhole camera for imaging X-ray synchrotron radiation from a dipole magnet is now in operation at the Shanghai Synchrotron Radiation Facility (SSRF) storage ring.The electron beam size is derived by unfolding the...A pinhole camera for imaging X-ray synchrotron radiation from a dipole magnet is now in operation at the Shanghai Synchrotron Radiation Facility (SSRF) storage ring.The electron beam size is derived by unfolding the radiation image and the point spread function (PSF) with deconvolution techniques.The performance of the pinhole is determined by the accuracy of the PSF measurement.This article will focus on a beam-based calibration scheme to measure the PSF system by varying the beam images with different quadrupole settings and fitting them with the corresponding theoretical beam sizes.Applying this method at SSRF,the PSF value of the pinhole is revised from 37 to 44μm.The deviation in beam size between the theoretical value and the measured value isminimized to 4% after calibration.This optimization allows us to observe the horizontal disturbance due to injection down to as small as 0.5μm.展开更多
Needs in scintimammography applications,especially for small animal cardiac imaging,lead to develop a small field of view,high spatial resolution gamma camera with a pinhole collimator.However the ideal pinhole collim...Needs in scintimammography applications,especially for small animal cardiac imaging,lead to develop a small field of view,high spatial resolution gamma camera with a pinhole collimator.However the ideal pinhole collimator must keep a compromise between spatial resolution and sensitivity.In order to design a pinhole collimator with an optimized sensitivity and spatial resolution,the spatial resolution and the geometric sensitivity response as a function of the source to collimator distance has been obtained by means of Monte-Carlo simulation for a small field of view gamma camera with a pinhole collimator of various-hole diameters.The results show that the camera with pinhole of 1 mm,1.5 mm and 2 mm diameter has respectively spatial resolution of 1.5 mm,2.25 mm and 3 mm and geometric sensitivity of 0.016%,0.022%and 0.036%,while the source to collimator distance is 3 cm.We chose the pinhole collimator with hole diameter size of 1.2 mm for our the gamma camera designed based on the trade-off between sensitivity and resolution.展开更多
A set of point spread functions (PSF) has been obtained by means of Monte-Carlo simulation for asmall gamma camera with a pinhole collimator of various hole diameters. The FOV (field of view) of the camera isexpended ...A set of point spread functions (PSF) has been obtained by means of Monte-Carlo simulation for asmall gamma camera with a pinhole collimator of various hole diameters. The FOV (field of view) of the camera isexpended from 45 mm to 70 mm in diameter. The position dependence of the variances of PSF is presented, and theacceptance for the 140 kev gamma rays is explored. A phantom of 70 mm in diameter was experimentally imaged inthe camera with effective FOV of only 45 mm in diameter.展开更多
A method to measure the detailed performance of polycapillary x-ray optics by a pinhole and charge coupled device(CCD)detector was proposed in this study.The pinhole was located between the x-ray source and the polyca...A method to measure the detailed performance of polycapillary x-ray optics by a pinhole and charge coupled device(CCD)detector was proposed in this study.The pinhole was located between the x-ray source and the polycapillary x-ray optics to determine the illuminating region of the incident x-ray beam on the input side of the optics.The CCD detector placed downstream of the polycapillary x-ray optics ensured that the incident x-ray beam controlled by the pinhole irradiated a specific region of the input surface of the optics.The intensity of the output beam of the polycapillary x-ray optics was obtained from the far-field image of the output beam of the optics captured by CCD detector.As an application example,the focal spot size,gain in power density,transmission efficiency,and beam divergence of different parts of a polycapillary focusing x-ray lenses(PFXRL)were measured by a pinhole and CCD detector.Three pinholes with diameters of 500,1000,and 2000μm were used to adjust the diameter of the incident x-ray beam illuminating the PFXRL from 500μm to the entire surface of the input side of the PFXRL.The focal spot size of the PFXRL,gain in power density,transmission efficiency,and beam divergence ranged from 27.1μm to 34.6μm,400 to 3460,26.70%to 5.38%,and 16.8 mrad to 84.86 mrad,respectively.展开更多
The radial x-ray camera(RXC) is designed to measure the poloidal profile of plasma x-ray emission with high spatial and temporal resolution. The RXC diagnostic system consists of internal camera module and external ca...The radial x-ray camera(RXC) is designed to measure the poloidal profile of plasma x-ray emission with high spatial and temporal resolution. The RXC diagnostic system consists of internal camera module and external camera module that view the core region and outer region through the vertical slots of the diagnostic first wall and diagnostics shield module of the equatorial port plug. To ensure the normal performance of the silicon photodiode array detectors of the cameras in the hard neutron irradiation environment in ITER tokamak, it is necessary to calculate neutron flux, radiation damage and the nuclear heating of the silicon photodiode array detectors and simulate the radiation maps of the range of RXC. This work estimated the nuclear environment of RXC based on Monte Carlo N-particle transport code, plasma scenarios of ITER tokamak and the RXC-integrated ITER CLITE model. The neutron flux of silicon photodiode array detectors and the lifetime of the silicon photodiode detector in the camera were calculated. The neutronic analysis results show that the shielding design has achieved the effect as expected and is able to guarantee the normal work of the detector during the ITER deuterium–deuterium phase without replacement, three detectors of the external camera can be operated during the whole deuterium–tritium phase without replacement.展开更多
The diagnostic methods for the profile of the radiation source were estab-lished at first based on the pinhole imaging principle. In this paper, the relationships among various parameters of the gamma-rays crammer suc...The diagnostic methods for the profile of the radiation source were estab-lished at first based on the pinhole imaging principle. In this paper, the relationships among various parameters of the gamma-rays crammer such as the modulation transfer function (MTF), the noise power spectrum (NPS), the signal-noise ratio (SNR) and the detective quantum efficiency (DQE) are developed and studied experimentally on the cobalt radiation source. The image diagnostic system is consisting with rays-fluorescence convertor (YAG crystal), optical imaging system, MCP image intensifier, CCD camera and other devices. The spatial resolution of the modulation transfer function (MTF) at 10% intensity was measured as 1 lp/mm by knife-edge method. The quantum of the measurement system is about 150 under weak radiation condition due to the single particle detection efficiency of the system. The dynamic range was inferred preliminarily as about 437. The required radiation intensity was calculated using the experiment result for the (SNR) = 1, 5, 10, respectively. The theoretical investigation results show that the radiation image with (SNR) = 1 can be only obtained when the pinhole diameter is 0.7 mm, object distance and image distance are both 200 cm, and the radiation intensity is about 1.0 × 1012 Sr-1·cm-2.展开更多
The streak camera is an ultra-fast diagnostic instrument with high sensitivity, and a high temporal and spatial resolution. It is primarily employed in various scientific research, such as inertial confinement fusion(...The streak camera is an ultra-fast diagnostic instrument with high sensitivity, and a high temporal and spatial resolution. It is primarily employed in various scientific research, such as inertial confinement fusion(ICF),synchrotron light sources, and electron–positron colliders.An automatic control system for an X-ray streak camera is presented in this paper. The output terminal of an analogto-digital converter was isolated from its input terminal, to reduce interference from high-voltage electrodes. Compared with traditional methods, this scheme also improved the internal electromagnetic interface immunity. Therefore,the system stability was enhanced. With this optimized control system, some characterizations of the streak camera were measured. Static and dynamic spatial resolutions of 25 and 20 lp/mm(CTF = 20%), respectively, were obtained. In addition, a dynamic range of 552:1 and a temporal resolution of 7.3 ps were achieved. The results confirmed that these characterizations are sufficient for the specifications derived from the diagnostic requirements of ICF.展开更多
It is challenging to make an ultrafast diagnosis of the temporal evolution of small and short-lived plasma in two dimensions. To overcome this difficulty, we have developed a well-timed diagnostic utilizing an x-ray s...It is challenging to make an ultrafast diagnosis of the temporal evolution of small and short-lived plasma in two dimensions. To overcome this difficulty, we have developed a well-timed diagnostic utilizing an x-ray streak camera equipped with a row of multi-pinhole arrays. By processing multiple sets of one-dimensional streaked image data acquired from various pinholes, we are capable of reconstructing high-resolution two-dimensional images with a temporal resolution of 38 ps and a spatial resolution of 18 μm. The temporal fiducial pulses accessed from external sources can advance the precise timing and accurately determine the arrival time of the laser. Moreover, it can correct the nonlinear sweeping speed of the streak camera. The effectiveness of this diagnostic has been successfully verified at the Shenguang-II laser facility,providing an indispensable tool for observing complex physical phenomena, such as the implosion process of laser-fusion experiments.展开更多
We develop a rapid and convenient experimental method of absolutely calibrating the transmission of an x-ray flatresponse filter. The calibration experiment is performed on a small laser-target facility, and a set of ...We develop a rapid and convenient experimental method of absolutely calibrating the transmission of an x-ray flatresponse filter. The calibration experiment is performed on a small laser-target facility, and a set of high resolution holographic flat-field grating spectrometers is used as a discrimination system of the laser-produced x-ray source. Given that the holographic flat-field grating has a relatively large width, the grating is divided into two regions for use in that direction,where one region has the filter added and the other region does not. The filter transmission is determined by dividing the x-ray signal counts detected when the filter is in the line of sight by those detected when the filter is out of the line of sight.We find that the calibration results of this experiment agree with the calibration results using a synchrotron radiation source,as well as simulation results. Our method is not only highly reliable but also rapid and convenient.展开更多
The pinhole gamma camera is the basis of the newly developed method of high-resolution pinhole single photon emission computed tomography (SPECT). In this paper, a pinhole gamma camera system was examined using the ch...The pinhole gamma camera is the basis of the newly developed method of high-resolution pinhole single photon emission computed tomography (SPECT). In this paper, a pinhole gamma camera system was examined using the channel model of information theory. The model pinhole gamma camera was simplified from a noisy, lossy channel to a noiseless, lossless channel by assuming a plane source. An approximate formula of average mutual information for the pinhole gamma camera was then derived from the model. Imaging experiments validated the applicability of the analytic formula. The findings demonstrated that the pinhole gamma camera can be adequately described using the channel model of information theory, and that average mutual information can be considered a figure of merit for the optimizing design of the pinhole gamma camera.展开更多
鱼眼相机由于其超宽的视场范围(Field of view,FOV)(可以达到180°以上),得到越来越广泛的应用.常规的基于小孔成像模型的相机矫正与标定算法在超宽视场的鱼眼成像系统中已经不太适用,为了兼顾小孔模型的特点,本文提出了一种扩展小...鱼眼相机由于其超宽的视场范围(Field of view,FOV)(可以达到180°以上),得到越来越广泛的应用.常规的基于小孔成像模型的相机矫正与标定算法在超宽视场的鱼眼成像系统中已经不太适用,为了兼顾小孔模型的特点,本文提出了一种扩展小孔成像模型的鱼眼相机矫正与标定方法.此方法是对小孔成像模型的进一步拓展,不仅具备小孔模型实现简单、适合人眼视觉效果以及相机标定方便等优点,同时将小孔成像模型适用的视场范围扩展到超宽视场领域.其基本思路是:在利用小孔成像模型对鱼眼相机90°左右视场范围进行矫正与标定的基础上,使用非等间距的点阵模板,并结合直线拟合以及自然邻点插值算法,扩展小孔模型适用的视场范围.本文使用鱼眼相机从不同的角度拍摄多幅模板图,完成鱼眼相机的矫正与标定.通过求取的小孔成像模型参数实现相机的标定;对鱼眼相机拍摄的实际场景图进行畸变矫正测试,结果表明此方法能够很好地矫正鱼眼相机存在的畸变,得到符合人眼视觉效果的矫正图;单幅矫正图视场范围达到130°,结合不同角度拍摄的多幅模板图,可把矫正的视场范围扩展到180°.展开更多
基金supported by the National Science Foundation of China(No.11375255)
文摘An X-ray pinhole camera has been used to determine the transverse beam size and emittance on the diagnostic beam line of the storage ring at SSRF since2009.The performance of the beam size measurement is determined by the width of the point spread function of the X-ray pinhole camera.Beam-based calibration was carried in 2012 out by varying the beam size at the source point and measuring the image size.However,this calibration method requires special beam conditions.In order to overcome this limitation,the pinhole camera was upgraded and an X-ray quasi-monochromator was installed.A novel experimental method was introduced by combining the pinhole camera with the monochromator to calibrate the point spread function.The point spread function can be accurately resolved by adjusting the angle of the monochromator and measuring the image size.The X-ray spectrum can also be obtained.In this work,the X-ray quasi-monochromator and the novel beam-based calibration method will be presented in detail.
基金supported by the Sichuan Science and Technology Program,China(No.2020ZDZX0004)。
文摘Spatial resolution and image-processing methods for full-field X-ray fluorescence(FF-XRF)imaging using X-ray pinhole cameras were studied using Geant4simulations with different geometries and algorithms for image reconstruction.The main objectives were:(1)calculating the quantum efficiency curves of specific cameras,(2)studying the relationships between the spatial resolution and the pinhole diameter,magnification,and camera binning value,and(3)comparing image-processing methods for pinhole camera systems.Several results were obtained using a point and plane source as the X-ray fluorescence emitter and an array of 100×100 silicon pixel detectors as the X-ray camera.The quantum efficiency of a back-illuminated deep depletion(BI-DD)structure was above 30%for the XRF energies in the 0.8–9 keV range,with the maximum of 93.7%at 4 keV.The best spatial resolution of the pinhole camera was 24.7μm and 31.3 lp/mm when measured using the profile function of the point source,with the diameter of 20μm,magnification of 3.16,and camera bin of 1.A blind deconvolution algorithm with Gaussian filtering performed better than the Wiener filter and Richardson iterative methods on FF-XRF images,with the signal-to-noise ratio of 7.81 dB and improved signalto-noise ratio of 7.24 dB at the diameter of 120μm,magnification of 1.0,and camera bin of 1.
文摘A pinhole camera for imaging X-ray synchrotron radiation from a dipole magnet is now in operation at the Shanghai Synchrotron Radiation Facility (SSRF) storage ring.The electron beam size is derived by unfolding the radiation image and the point spread function (PSF) with deconvolution techniques.The performance of the pinhole is determined by the accuracy of the PSF measurement.This article will focus on a beam-based calibration scheme to measure the PSF system by varying the beam images with different quadrupole settings and fitting them with the corresponding theoretical beam sizes.Applying this method at SSRF,the PSF value of the pinhole is revised from 37 to 44μm.The deviation in beam size between the theoretical value and the measured value isminimized to 4% after calibration.This optimization allows us to observe the horizontal disturbance due to injection down to as small as 0.5μm.
基金Supported by National Foundation of Nature Science of China(No.10275063)
文摘Needs in scintimammography applications,especially for small animal cardiac imaging,lead to develop a small field of view,high spatial resolution gamma camera with a pinhole collimator.However the ideal pinhole collimator must keep a compromise between spatial resolution and sensitivity.In order to design a pinhole collimator with an optimized sensitivity and spatial resolution,the spatial resolution and the geometric sensitivity response as a function of the source to collimator distance has been obtained by means of Monte-Carlo simulation for a small field of view gamma camera with a pinhole collimator of various-hole diameters.The results show that the camera with pinhole of 1 mm,1.5 mm and 2 mm diameter has respectively spatial resolution of 1.5 mm,2.25 mm and 3 mm and geometric sensitivity of 0.016%,0.022%and 0.036%,while the source to collimator distance is 3 cm.We chose the pinhole collimator with hole diameter size of 1.2 mm for our the gamma camera designed based on the trade-off between sensitivity and resolution.
基金Supported by the National Natural Science Foundation of China(10275063)
文摘A set of point spread functions (PSF) has been obtained by means of Monte-Carlo simulation for asmall gamma camera with a pinhole collimator of various hole diameters. The FOV (field of view) of the camera isexpended from 45 mm to 70 mm in diameter. The position dependence of the variances of PSF is presented, and theacceptance for the 140 kev gamma rays is explored. A phantom of 70 mm in diameter was experimentally imaged inthe camera with effective FOV of only 45 mm in diameter.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.11675019,12105020,and 12075031)the Bud Project of Beijing Academy of Science and Technology(Grant No.BGS202106)the National Key Research and Development Program of China(Grant No.2021YFF0701202)
文摘A method to measure the detailed performance of polycapillary x-ray optics by a pinhole and charge coupled device(CCD)detector was proposed in this study.The pinhole was located between the x-ray source and the polycapillary x-ray optics to determine the illuminating region of the incident x-ray beam on the input side of the optics.The CCD detector placed downstream of the polycapillary x-ray optics ensured that the incident x-ray beam controlled by the pinhole irradiated a specific region of the input surface of the optics.The intensity of the output beam of the polycapillary x-ray optics was obtained from the far-field image of the output beam of the optics captured by CCD detector.As an application example,the focal spot size,gain in power density,transmission efficiency,and beam divergence of different parts of a polycapillary focusing x-ray lenses(PFXRL)were measured by a pinhole and CCD detector.Three pinholes with diameters of 500,1000,and 2000μm were used to adjust the diameter of the incident x-ray beam illuminating the PFXRL from 500μm to the entire surface of the input side of the PFXRL.The focal spot size of the PFXRL,gain in power density,transmission efficiency,and beam divergence ranged from 27.1μm to 34.6μm,400 to 3460,26.70%to 5.38%,and 16.8 mrad to 84.86 mrad,respectively.
基金supported by National Natural Science Foundation of China (No. 11605240)China International Nuclear Fusion Energy Program Execution Center Radial x-ray Camera Design Contract (No. 5.5.P1.CN.02/1A)
文摘The radial x-ray camera(RXC) is designed to measure the poloidal profile of plasma x-ray emission with high spatial and temporal resolution. The RXC diagnostic system consists of internal camera module and external camera module that view the core region and outer region through the vertical slots of the diagnostic first wall and diagnostics shield module of the equatorial port plug. To ensure the normal performance of the silicon photodiode array detectors of the cameras in the hard neutron irradiation environment in ITER tokamak, it is necessary to calculate neutron flux, radiation damage and the nuclear heating of the silicon photodiode array detectors and simulate the radiation maps of the range of RXC. This work estimated the nuclear environment of RXC based on Monte Carlo N-particle transport code, plasma scenarios of ITER tokamak and the RXC-integrated ITER CLITE model. The neutron flux of silicon photodiode array detectors and the lifetime of the silicon photodiode detector in the camera were calculated. The neutronic analysis results show that the shielding design has achieved the effect as expected and is able to guarantee the normal work of the detector during the ITER deuterium–deuterium phase without replacement, three detectors of the external camera can be operated during the whole deuterium–tritium phase without replacement.
文摘The diagnostic methods for the profile of the radiation source were estab-lished at first based on the pinhole imaging principle. In this paper, the relationships among various parameters of the gamma-rays crammer such as the modulation transfer function (MTF), the noise power spectrum (NPS), the signal-noise ratio (SNR) and the detective quantum efficiency (DQE) are developed and studied experimentally on the cobalt radiation source. The image diagnostic system is consisting with rays-fluorescence convertor (YAG crystal), optical imaging system, MCP image intensifier, CCD camera and other devices. The spatial resolution of the modulation transfer function (MTF) at 10% intensity was measured as 1 lp/mm by knife-edge method. The quantum of the measurement system is about 150 under weak radiation condition due to the single particle detection efficiency of the system. The dynamic range was inferred preliminarily as about 437. The required radiation intensity was calculated using the experiment result for the (SNR) = 1, 5, 10, respectively. The theoretical investigation results show that the radiation image with (SNR) = 1 can be only obtained when the pinhole diameter is 0.7 mm, object distance and image distance are both 200 cm, and the radiation intensity is about 1.0 × 1012 Sr-1·cm-2.
文摘The streak camera is an ultra-fast diagnostic instrument with high sensitivity, and a high temporal and spatial resolution. It is primarily employed in various scientific research, such as inertial confinement fusion(ICF),synchrotron light sources, and electron–positron colliders.An automatic control system for an X-ray streak camera is presented in this paper. The output terminal of an analogto-digital converter was isolated from its input terminal, to reduce interference from high-voltage electrodes. Compared with traditional methods, this scheme also improved the internal electromagnetic interface immunity. Therefore,the system stability was enhanced. With this optimized control system, some characterizations of the streak camera were measured. Static and dynamic spatial resolutions of 25 and 20 lp/mm(CTF = 20%), respectively, were obtained. In addition, a dynamic range of 552:1 and a temporal resolution of 7.3 ps were achieved. The results confirmed that these characterizations are sufficient for the specifications derived from the diagnostic requirements of ICF.
基金supported by the Strategic Priority Research Program of the Chinese Academy of Sciences (Grant Nos. XDA25030700 and XDA25030500)the National Key R&D Program of China (Grant Nos. 2022YFA1603200 and 2022YFA1603203)the National Natural Science Foundation of China (Grant Nos. 12175018, 12135001, 12075030, and 11903006)。
文摘It is challenging to make an ultrafast diagnosis of the temporal evolution of small and short-lived plasma in two dimensions. To overcome this difficulty, we have developed a well-timed diagnostic utilizing an x-ray streak camera equipped with a row of multi-pinhole arrays. By processing multiple sets of one-dimensional streaked image data acquired from various pinholes, we are capable of reconstructing high-resolution two-dimensional images with a temporal resolution of 38 ps and a spatial resolution of 18 μm. The temporal fiducial pulses accessed from external sources can advance the precise timing and accurately determine the arrival time of the laser. Moreover, it can correct the nonlinear sweeping speed of the streak camera. The effectiveness of this diagnostic has been successfully verified at the Shenguang-II laser facility,providing an indispensable tool for observing complex physical phenomena, such as the implosion process of laser-fusion experiments.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.11405158 and 11775203)the Presidential Foundation of China Academy of Engineering Physics(Grant No.YZJJLX 2016007)
文摘We develop a rapid and convenient experimental method of absolutely calibrating the transmission of an x-ray flatresponse filter. The calibration experiment is performed on a small laser-target facility, and a set of high resolution holographic flat-field grating spectrometers is used as a discrimination system of the laser-produced x-ray source. Given that the holographic flat-field grating has a relatively large width, the grating is divided into two regions for use in that direction,where one region has the filter added and the other region does not. The filter transmission is determined by dividing the x-ray signal counts detected when the filter is in the line of sight by those detected when the filter is out of the line of sight.We find that the calibration results of this experiment agree with the calibration results using a synchrotron radiation source,as well as simulation results. Our method is not only highly reliable but also rapid and convenient.
文摘The pinhole gamma camera is the basis of the newly developed method of high-resolution pinhole single photon emission computed tomography (SPECT). In this paper, a pinhole gamma camera system was examined using the channel model of information theory. The model pinhole gamma camera was simplified from a noisy, lossy channel to a noiseless, lossless channel by assuming a plane source. An approximate formula of average mutual information for the pinhole gamma camera was then derived from the model. Imaging experiments validated the applicability of the analytic formula. The findings demonstrated that the pinhole gamma camera can be adequately described using the channel model of information theory, and that average mutual information can be considered a figure of merit for the optimizing design of the pinhole gamma camera.
文摘鱼眼相机由于其超宽的视场范围(Field of view,FOV)(可以达到180°以上),得到越来越广泛的应用.常规的基于小孔成像模型的相机矫正与标定算法在超宽视场的鱼眼成像系统中已经不太适用,为了兼顾小孔模型的特点,本文提出了一种扩展小孔成像模型的鱼眼相机矫正与标定方法.此方法是对小孔成像模型的进一步拓展,不仅具备小孔模型实现简单、适合人眼视觉效果以及相机标定方便等优点,同时将小孔成像模型适用的视场范围扩展到超宽视场领域.其基本思路是:在利用小孔成像模型对鱼眼相机90°左右视场范围进行矫正与标定的基础上,使用非等间距的点阵模板,并结合直线拟合以及自然邻点插值算法,扩展小孔模型适用的视场范围.本文使用鱼眼相机从不同的角度拍摄多幅模板图,完成鱼眼相机的矫正与标定.通过求取的小孔成像模型参数实现相机的标定;对鱼眼相机拍摄的实际场景图进行畸变矫正测试,结果表明此方法能够很好地矫正鱼眼相机存在的畸变,得到符合人眼视觉效果的矫正图;单幅矫正图视场范围达到130°,结合不同角度拍摄的多幅模板图,可把矫正的视场范围扩展到180°.