期刊文献+
共找到1,471篇文章
< 1 2 74 >
每页显示 20 50 100
Tunable energy spectrum betatron x-ray sources in a plasma wakefield
1
作者 奚传易 寿寅任 +4 位作者 韩立琦 阿卜杜伍普尔·阿布力米提 刘晓丹 赵研英 余金清 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第8期344-350,共7页
X-ray sources with tunable energy spectra have a wide range of applications in different scenarios due to their different penetration depths.However,existing x-ray sources face difficulties in terms of energy regulati... X-ray sources with tunable energy spectra have a wide range of applications in different scenarios due to their different penetration depths.However,existing x-ray sources face difficulties in terms of energy regulation.In this paper,we present a scheme for tuning the energy spectrum of a betatron x-ray generated from a relativistic electron bunch oscillating in a plasma wakefield.The center energy of the x-ray source can be tuned from several keV to several hundred keV by changing the plasma density,thereby extending the control range by an order of magnitude.At different central energies,the brightness of the betatron radiation is in the range of 3.7×10^(22)to 5.5×10^(22)photons/(0.1%BW·s·mm^(2)·mrad^(2))and the photon divergence angle is about 2 mrad.This high-brightness,energy-controlled betatron source could pave the way to a wide range of applications requiring photons of specific energy,such as phase-contrast imaging in medicine,non-destructive testing and material analysis in industry,and imaging in nuclear physics. 展开更多
关键词 betatron plasma physics x-ray plasma wakefield acceleration(PWFA)
下载PDF
High-resolution x-ray monochromatic imaging for laser plasma diagnostics based on toroidal crystal 被引量:2
2
作者 司昊轩 董佳钦 +3 位作者 方智恒 蒋励 伊圣振 王占山 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第1期181-186,共6页
Monochromatic x-ray imaging is an essential method for plasma diagnostics related to density information.Large-field high-resolution monochromatic imaging of a He-like iron(Fe XXV)Kαcharacteristic line(6.701 keV)for ... Monochromatic x-ray imaging is an essential method for plasma diagnostics related to density information.Large-field high-resolution monochromatic imaging of a He-like iron(Fe XXV)Kαcharacteristic line(6.701 keV)for laser plasma diagnostics was achieved using a developed toroidal crystal x-ray imager.A high-index crystal orientation Ge(531)wafer with a Bragg angle of 75.37°and the toroidal substrate were selected to obtain sufficient diffraction efficiency and compensate for astigmatism under oblique incidence.A precise offline assembly method of the toroidal crystal imager based on energy substitution was proposed,and a spatial resolution of 3-7μm was obtained by toroidal crystal imaging of a 600 line-pairs/inch Au grid within an object field of view larger than 1.0 mm.The toroidal crystal x-ray imager has been successfully tested via side-on backlight imaging experiments of the sinusoidal modulation target and a 1000 line-pairs/inch Au grid with a linewidth of 5μm using an online alignment method based on dual positioning balls to indicate the target and backlighter.This paper describes the optical design,adjustment method,and experimental results of a toroidal crystal system in a laboratory and laser facility. 展开更多
关键词 laser plasma diagnostics toroidal crystal monochromatic x-ray imaging
下载PDF
The Soft X-ray Imager(SXI)on the SMILE Mission 被引量:4
3
作者 S.Sembay A.L.Alme +83 位作者 D.Agnolon T.Arnold A.Beardmore A.Belén Balado Margeli C.Bicknell C.Bouldin G.Branduardi-Raymont T.Crawford J.P.Breuer T.Buggey G.Butcher R.Canchal J.A.Carter A.Cheney Y.Collado-Vega H.Connor T.Crawford N.Eaton C.Feldman C.Forsyth T.Frantzen G.Galgóczi J.Garcia G.Y.Genov C.Gordillo H-P.Gröbelbauer M.Guedel Y.Guo M.Hailey D.Hall R.Hampson J.Hasiba O.Hetherington A.Holland S-Y.Hsieh M.W.J.Hubbard H.Jeszenszky M.Jones T.Kennedy K.Koch-Mehrin S.Kögl S.Krucker K.D.Kuntz C.Lakin G.Laky O.Lylund A.Martindale J.Miguel Mas Hesse R.Nakamura K.Oksavik N.Østgaard H.Ottacher R.Ottensamer C.Pagani S.Parsons P.Patel J.Pearson G.Peikert F.S.Porter T.Pouliantis B.H.Qureshi W.Raab G.Randal A.M.Read N.M.M.Roque M.E.Rostad C.Runciman S.Sachdev A.Samsonov M.Soman D.Sibeck S.Smit J.Søndergaard R.Speight S.Stavland M.Steller TianRan Sun J.Thornhill W.Thomas K.Ullaland B.Walsh D.Walton C.Wang S.Yang 《Earth and Planetary Physics》 EI CSCD 2024年第1期5-14,共10页
The Soft X-ray Imager(SXI)is part of the scientific payload of the Solar wind Magnetosphere Ionosphere Link Explorer(SMILE)mission.SMILE is a joint science mission between the European Space Agency(ESA)and the Chinese... The Soft X-ray Imager(SXI)is part of the scientific payload of the Solar wind Magnetosphere Ionosphere Link Explorer(SMILE)mission.SMILE is a joint science mission between the European Space Agency(ESA)and the Chinese Academy of Sciences(CAS)and is due for launch in 2025.SXI is a compact X-ray telescope with a wide field-of-view(FOV)capable of encompassing large portions of Earth’s magnetosphere from the vantage point of the SMILE orbit.SXI is sensitive to the soft X-rays produced by the Solar Wind Charge eXchange(SWCX)process produced when heavy ions of solar wind origin interact with neutral particles in Earth’s exosphere.SWCX provides a mechanism for boundary detection within the magnetosphere,such as the position of Earth’s magnetopause,because the solar wind heavy ions have a very low density in regions of closed magnetic field lines.The sensitivity of the SXI is such that it can potentially track movements of the magnetopause on timescales of a few minutes and the orbit of SMILE will enable such movements to be tracked for segments lasting many hours.SXI is led by the University of Leicester in the United Kingdom(UK)with collaborating organisations on hardware,software and science support within the UK,Europe,China and the United States. 展开更多
关键词 Soft x-ray Imaging micropore optics large area CCD
下载PDF
Time-resolved K-shell x-ray spectra of nanosecond laser-produced titanium tracer in gold plasmas
4
作者 何贞岑 张继彦 +2 位作者 杨家敏 闫冰 胡智民 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第1期51-55,共5页
A study of a nanosecond laser irradiation on the titanium-layer-buried gold planar target is presented. The timeresolved x-ray emission spectra of titanium tracer are measured by a streaked crystal spectrometer. By co... A study of a nanosecond laser irradiation on the titanium-layer-buried gold planar target is presented. The timeresolved x-ray emission spectra of titanium tracer are measured by a streaked crystal spectrometer. By comparing the simulated spectra obtained by using the FLYCHK code with the measured titanium spectra, the temporal plasma states, i.e.,the electron temperatures and densities, are deduced. To evaluate the feasibility of using the method for the characterization of Au plasma states, the deduced plasma states from the measured titanium spectra are compared with the Multi-1D hydrodynamic simulations of laser-produced Au plasmas. By comparing the measured and simulated results, an overall agreement for the electron temperatures is found, whereas there are deviations in the electron densities. The experiment–theory discrepancy may suggest that the plasma state could not be well reproduced by the Multi-1D hydrodynamic simulation, in which the radial gradient is not taken into account. Further investigations on the spectral characterization and hydrodynamic simulations of the plasma states are needed. All the measured and FLYCHK simulated spectra are given in this paper as datasets. The datasets are openly available at http://www.doi.org/10.57760/sciencedb.j00113.00032. 展开更多
关键词 nanosecond laser irradiation time-resolved x-ray spectra characterization of plasma states Multi-1D hydrodynamic simulations
下载PDF
Property of slice square polycapillary x-ray optics 被引量:1
5
作者 彭诗棋 刘志国 +5 位作者 孙天希 王锴 易龙涛 杨魁 陈曼 王金榜 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第2期159-163,共5页
A geometrical description of square polycapillary x-ray optics and the basic theory of the transmission of x-rays are presented. A method of numerical calculation is developed based on ray-tracing theory. The method s... A geometrical description of square polycapillary x-ray optics and the basic theory of the transmission of x-rays are presented. A method of numerical calculation is developed based on ray-tracing theory. The method simulates the intensity distribution of x-rays propagating through slice square polycapillary x-ray optics. The simulation results are compared with the experimental results. 展开更多
关键词 x-ray square polycapillary x-ray optics RAY-TRACING simulation computing
下载PDF
Development of D_α band symmetrical visible optical diagnostic for boundary reconstruction on EAST tokamak
6
作者 陈明 沈飊 +4 位作者 Shinichiro KADO 郭笔豪 陈大龙 蔡福瑞 肖炳甲 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第2期44-53,共10页
To investigate the potential of utilizing visible spectral imaging for controlling the plasma boundary shape during stable operation of plasma in future tokamak, a D_α band symmetric visible light diagnostic system w... To investigate the potential of utilizing visible spectral imaging for controlling the plasma boundary shape during stable operation of plasma in future tokamak, a D_α band symmetric visible light diagnostic system was designed and implemented on the Experimental Advanced Superconducting Tokamak(EAST). This system leverages two symmetric optics for joint plasma imaging. The optical system exhibits a spatial resolution less than 2 mm at the poloidal cross-section, distortion within the field of view below 10%, and relative illumination of 91%.The high-quality images obtained enable clear observation of both the plasma boundary position and the characteristics of components within the vacuum vessel. Following system calibration and coordinate transformation, the image coordinate boundary features are mapped to the tokamak coordinate system. Utilizing this system, the plasma boundary was reconstructed, and the resulting representation showed alignment with the EFIT(Equilibrium Fitting) results. This underscores the system's superior performance in boundary reconstruction applications and provides a diagnostic foundation for boundary shape control based on visible spectral imaging. 展开更多
关键词 visible optical diagnostic plasma boundary reconstruction EAST
下载PDF
Optimized online filter stack spectrometer for ultrashort X-ray pulses
7
作者 Jia-Xing Wen Ge Ma +17 位作者 Ming-Hai Yu Yu-Chi Wu Yong-Hong Yan Shao-Yi Wang Huai-Zhong Gao Lu-Shan Wang Yu-Gang Zhou Qiang Li Yue Yang Fang Tan Xiao-Hui Zhang Jie Zhang Wen-Bo Mo Jing-Qin Su Wei-Min Zhou Yu-Qiu Gu Ming Zeng Zong-Qing Zhao 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第5期85-98,共14页
Currently,with the advent of high-repetition-rate laser-plasma experiments,the demand for online diagnosis for the X-ray spectrum is increasing because the laser-plasma-generated X-ray spectrum is very important for c... Currently,with the advent of high-repetition-rate laser-plasma experiments,the demand for online diagnosis for the X-ray spectrum is increasing because the laser-plasma-generated X-ray spectrum is very important for characterizing electron dynamics and applications.In this study,scintillators and silicon PIN(P-type–intrinsic-N-type semiconductor)diodes were used to construct a wideband online filter stack spectrometer.The X-ray sensor and filter arrangement was optimized using a genetic algorithm to minimize the condition number of the response matrix.Consequently,the unfolding error was significantly reduced based on numerical experiments.The detector responses were quantitatively calibrated by irradiating the scintillator and PIN diode with various nuclides and comparing the measuredγ-ray peaks.A prototype 15-channel spectrometer was developed by integrating an X-ray detector with front-and back-end electronics.The prototype spectrometer could record X-ray pulse signals at a repetition rate of 1 kHz.Furthermore,an optimized spectrometer was employed to record the real-time spectra of laser-driven bremsstrahlung sources.This optimized spectrometer offers a compact solution for spectrum diagnostics of ultrashort X-ray pulses,exhibiting improved accuracy in terms of spectrum measurements and repetition rates,and could be widely used in next-generation high-repetition-rate high-power laser facilities. 展开更多
关键词 Filter stack spectrometer Laser plasma diagnostics x-ray diagnostics Scintillator PIN diode
下载PDF
Transition from a filamentary mode to a diffuse one with varying distance from needle to stream of an argon plasma jet
8
作者 许慧敏 高敬格 +3 位作者 贾鹏英 冉俊霞 陈俊宇 李金懋 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第1期539-544,共6页
Plasma jet has extensive application potentials in various fields, which normally operates in a diffuse mode when helium is used as the working gas. However, when less expensive argon is used, the plasma jet often ope... Plasma jet has extensive application potentials in various fields, which normally operates in a diffuse mode when helium is used as the working gas. However, when less expensive argon is used, the plasma jet often operates in a filamentary mode. Compared to the filamentary mode, the diffuse mode is more desirable for applications. Hence, many efforts have been exerted to accomplish the diffuse mode of the argon plasma jet. In this paper, a novel single-needle argon plasma jet is developed to obtain the diffuse mode. It is found that the plasma jet operates in the filamentary mode when the distance from the needle tip to the central line of the argon stream(d) is short. It transits to the diffuse mode with increasing d. For the diffuse mode, there is always one discharge pulse per voltage cycle, which initiates at the rising edge of the positive voltage. For comparison, the number of discharge pulse increases with an increase in the peak voltage for the filamentary mode. Fast photography reveals that the plasma plume in the filamentary mode results from a guided positive streamer,which propagates in the argon stream. However, the plume in the diffuse mode originates from a branched streamer, which propagates in the interfacial layer between the argon stream and the surrounding air. By optical emission spectroscopy,plasma parameters are investigated for the two discharge modes, which show a similar trend with increasing d. The diffuse mode has lower electron temperature, electron density, vibrational temperature, and gas temperature compared to the filamentary mode. 展开更多
关键词 plasma jet diffuse mode filamentary mode optical emission spectroscopy
下载PDF
The Study Internal Structure of the Annual Layers in Lake Sediments Using Synchrotron Radiation with X-ray Focusing Optics
9
作者 Fedor DARIN Ivan KALUGIN +1 位作者 Andrey DARIN Yakov RAKSHUN 《Acta Geologica Sinica(English Edition)》 SCIE CAS CSCD 2014年第S1期5-6,共2页
1 Introduction Annually laminated(varve)sedimentary deposits are considered as one of the most important archives,since they offer precise temporal information(years)in combination with high time resolutions.Bottom se... 1 Introduction Annually laminated(varve)sedimentary deposits are considered as one of the most important archives,since they offer precise temporal information(years)in combination with high time resolutions.Bottom sediments of the lakes contain detailed geochemical information on 展开更多
关键词 VARVE .synchrotron radiation scanning X_ray fluorescence microanalysis focusing x-ray optics.
下载PDF
Space Soft X-ray and EUV Optics in CIOMP
10
作者 CHEN Bo NI Qi-liang WANG Jun-lin 《光机电信息》 2006年第12期40-43,共4页
1 Introduction Since the early of 1980’s,the studies of soft X-ray and EUV optics have been implemented in CIOMP (Changchun Institute of Optics,Fine Mechanics and Physics).So far,the research system of soft X-ray an... 1 Introduction Since the early of 1980’s,the studies of soft X-ray and EUV optics have been implemented in CIOMP (Changchun Institute of Optics,Fine Mechanics and Physics).So far,the research system of soft X-ray and EUV optics has been founded including sources,ra- diometry,testing and manufacturing of the super smooth mirror and multilayer coating mirror fabrication.Based on the above technologies,we started to develop the soft X-ray and EUV optical system such as a space EUV solar telescope and a EUV imager. 展开更多
关键词 EUV Space Soft x-ray and EUV optics in CIOMP
下载PDF
PLASMA RESONANCE FIBER OPTIC SENSOR FOR CURE MONITORING OF EPOXY COMPOSITE
11
作者 邱浩 梁大开 +1 位作者 张焕春 经亚枝 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2001年第2期182-187,共6页
The plasma resonance fiber optic sensor has a research values in theory and is widely used in engineering because of its simple structure and high sensitivity. It is a simple and sensitive method to measure the refrac... The plasma resonance fiber optic sensor has a research values in theory and is widely used in engineering because of its simple structure and high sensitivity. It is a simple and sensitive method to measure the refractive index with optical fiber plasma wave. We make use of this characteristic to manufacture the plasma resonance fiber optic sensor which can detect the cure of epoxy compo site. We study the method of testing the solutions which have different refractive index with plasma resonance fiber optic sensor. A fiber optic sensing probe which has reliable performance and convenient operation for detecting the refractive index has been designed. The system for detecting the solution refractive index is developed and used to measure the refractive index of epoxy during the different phases in the cure process. Result shows that this system is credible and stable, the parameters tested are in accord with the facts. 展开更多
关键词 plasma wave fiber optic sensor refractive index EPOXY cure detecting
下载PDF
Plasma diagnostics by optical emission spectroscopy on manganese ore in conjunction with XRD, XRF and SEM-EDS 被引量:4
12
作者 Muhammad FAHAD Sajad ALI Yaseen IQBAL 《Plasma Science and Technology》 SCIE EI CAS CSCD 2019年第8期103-110,共8页
Manganese(Mn) is an important industrial mineral.Information about the chemical and phase constitution along with the concentration of impurities presented in Mn ore is compulsory in assessing its suitability for diff... Manganese(Mn) is an important industrial mineral.Information about the chemical and phase constitution along with the concentration of impurities presented in Mn ore is compulsory in assessing its suitability for different applications.We performed the qualitative and quantitative analysis of low-grade Mn ore(LGMO) using laser-induced breakdown spectroscopy(LIBS) in conjunction with x-ray diffraction(XRD), x-ray fluorescence(XRF) and scanning electron microscopy(SEM) coupled with energy dispersive x-ray electron spectroscopy(EDS).The optical emission spectra of the LGMO sample displayed the presence of Mn, Si, Ca, Fe, Al, Mg,V, Ti, Sr, Ni, Na, Ba and Li.The plasma parameters, electron temperature and number density were estimated using the Boltzmann plot and Stark broadening line profile methods and were found to be 7500 K±750 K and 8.18±0.8×1017 cm-3, respectively.Quantitative analysis was performed using the calibration-free LIBS(CF-LIBS) method and its outcome along with XRD, XRF and SEM-EDS data showed almost analogous elemental composition, while the LIBS method gave acceptably precise elemental analysis by detecting the low atomic number element Li besides V and Sr.The results obtained using LIBS for the LGMO exhibited its ability as a powerful analytical tool and XRF, XRD and SEM-EDS as complementary methods for the compositional analysis of complex low-grade mineral ore. 展开更多
关键词 plasma diagnostic optical emission SPECTROSCOPY spectrochemical analysis LASER-INDUCED BREAKDOWN SPECTROSCOPY SEM-EDS
下载PDF
Plasma Uniformity in a Dual Frequency Capacitively Coupled Plasma Reactor Measured by Optical Emission Spectroscopy 被引量:2
13
作者 赵国利 徐勇 +3 位作者 尚建平 刘文耀 朱爱民 王友年 《Plasma Science and Technology》 SCIE EI CAS CSCD 2011年第1期61-67,共7页
Local measurement of plasma radial uniformity was performed in a dual frequency capacitively coupled argon plasma (DF-CCP) reactor using an optical probe. The optical probe collects the light emission from a small s... Local measurement of plasma radial uniformity was performed in a dual frequency capacitively coupled argon plasma (DF-CCP) reactor using an optical probe. The optical probe collects the light emission from a small separate volume in plasma, thus enabling to diagnose the plasma uniformity for different experimental parameters. Both the gas pressure and the low- frequency (LF) power have apparent effects on the radial uniformity of argon plasma. With the increase in either pressure or LF power, the emission profiles changed from a bell-shaped to a double-peak distribution. The influence of a fused-silica ring around the electrodes on the plasma uniformity was also studied using the optical probe. Possible reasons that result in nonuniform plasmas in our experiments are discussed. 展开更多
关键词 dual frequency capacitively coupled plasma optical probe plasma uniformity
下载PDF
The determination of 52 elements in marine geological samples by an inductively coupled plasma optical emission spectrometry and an inductively coupled plasma mass spectrometry with a high-pressure closed digestion method 被引量:15
14
作者 GAO Jingjing LIU Jihua +3 位作者 LI Xianguo YAN Quanshu WANG Xiaojing WANG Hongmin 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2017年第1期109-117,共9页
An improved analytical method to determine the content of 52 major, minor and trace elements in marine geological samples, using a HF-HCl-HNO_3 acid system with a high-pressure closed digestion method(HPCD), is stud... An improved analytical method to determine the content of 52 major, minor and trace elements in marine geological samples, using a HF-HCl-HNO_3 acid system with a high-pressure closed digestion method(HPCD), is studied by an inductively coupled plasma optical emission spectrometry(ICP-OES) and an inductively coupled plasma mass spectrometry(ICP-MS). The operating parameters of the instruments are optimized, and the optimal analytical parameters are determined. The influences of optical spectrum and mass spectrum interferences, digestion methods and acid systems on the analytical results are investigated. The optimal spectral lines and isotopes are chosen, and internal standard element of rhodium is selected to compensate for matrix effects and analytical signals drifting. Compared with the methods of an electric heating plate digestion and a microwave digestion, a high-pressure closed digestion method is optimized with less acid, complete digestion,less damage for digestion process. The marine geological samples are dissolved completely by a HF-HCl-HNO_3 system, the relative error(RE) for the analytical results are all less than 6.0%. The method detection limits are 2–40μg/g by the ICP-OES, and 6–80 ng/g by ICP-MS. The methods are used to determine the marine sediment reference materials(GBW07309, GBW07311, GBW07313), rock reference materials(GBW07103, GBW07104,GBW07105), and cobalt-rich crust reference materials(GBW07337, GBW07338, GBW07339), the obtained analytical results are in agreement with the certified values, and both of the relative standard deviation(RSD) and the relative error(RE) are less than 6.0%. The analytical method meets the requirements for determining 52 elements contents of bulk marine geological samples. 展开更多
关键词 marine geological sample high-pressure closed digestion method inductively coupled plasma optical emission spectrometry inductively coupled plasma mass spectrometry major element minor element trace element
下载PDF
2D hydrodynamic simulation of a line-focused plasma in Ni-like Ag x-ray laser research 被引量:3
15
作者 郑无敌 张国平 《Chinese Physics B》 SCIE EI CAS CSCD 2007年第8期2439-2443,共5页
In most collisional schemes of x-ray laser (XRL) experiments, a bow-like intensity distribution of XRL is often observed, and it is generally ascribed to the two-dimensional hydrodynamic behaviour of expanding plasm... In most collisional schemes of x-ray laser (XRL) experiments, a bow-like intensity distribution of XRL is often observed, and it is generally ascribed to the two-dimensional hydrodynamic behaviour of expanding plasma. In order to better understand its essence in physics, a newly developed two-dimensional non-equilibrium radiation hydrodynamic code XRL2D is used to simulate a quasi-steady state Ni-like Ag XRL experiment on ShenGuang-Ⅱfacility. The simulation results show that the bow-like distribution of Ni-like ions caused by over-ionization in the central area of plasma is responsible for the bow-like shape of the XRL intensity distribution observed. 展开更多
关键词 x-ray laser numerical simulation line-focused plasma
下载PDF
Investigation on plasma characteristics in a laser ablation pulsed plasma thruster by optical emission spectroscopy 被引量:2
16
作者 Yu ZHANG Jianjun WU +2 位作者 Yang OU Daixian ZHANG Jian LI 《Plasma Science and Technology》 SCIE EI CAS CSCD 2020年第4期83-89,共7页
In order to further improve the propulsion performance of pulsed plasma thrusters for space micro propulsion,a novel laser ablation pulsed plasma thruster is proposed,which separated the laser ablation and electromagn... In order to further improve the propulsion performance of pulsed plasma thrusters for space micro propulsion,a novel laser ablation pulsed plasma thruster is proposed,which separated the laser ablation and electromagnetic acceleration.Optical emission spectroscopy is utilized to investigate the plasma characteristics in the thruster.The spectral lines at different times,positions and discharge intensities are experimentally recorded,and the plasma characteristics in the discharge channel are concluded through analyzing the variation of spectral lines.With the discharge energy of 24 J,laser energy of 0.6 J and the use of aluminum propellant,the specific impulse and thrust efficiency reach 6808 s and 70.6%,respectively. 展开更多
关键词 laser ablation PULSED plasma THRUSTER optical EMISSION SPECTROSCOPY plasma PROPULSION performance
下载PDF
A comparison among optical emission spectroscopic methods of determining electron temperature in low pressure argon plasmas 被引量:3
17
作者 牛田野 曹金祥 +4 位作者 刘磊 刘金英 王艳 王亮 吕铀 《Chinese Physics B》 SCIE EI CAS CSCD 2007年第9期2757-2763,共7页
In this article, four kinds of optical emission spectroscopic methods of determining electron temperature are used to investigate the relationship between electron temperature and pressure in the cylindrical plasmas o... In this article, four kinds of optical emission spectroscopic methods of determining electron temperature are used to investigate the relationship between electron temperature and pressure in the cylindrical plasmas of dc glow discharges at low pressures in laboratory by measuring the relative intensities of ArI lines at various pressures. These methods are developed respectively on the basis of the Fermi-Dirac model, corona model, and two kinds of electron collision cross section models according to the kinetic analysis. Their theoretical bases and the conditions to which they are applicable are reviewed, and their calculation results and fitting errors are compared with each other. The investigation has indicated that the electron temperatures obtained by the four methods become consistent with each other when the pressure increases in the low pressure argon plasmas. 展开更多
关键词 plasma diagnostics gas discharge optic emission spectroscopy electron temperature
下载PDF
Measurement of electron density and electron temperature of a cascaded arc plasma using laser Thomson scattering compared to an optical emission spectroscopic approach 被引量:2
18
作者 Yong WANG Cong LI +2 位作者 Jielin SHI Xingwei WU Hongbin DING 《Plasma Science and Technology》 SCIE EI CAS CSCD 2017年第11期23-30,共8页
As advanced linear plasma sources, cascaded arc plasma devices have been used to generate steady plasma with high electron density, high particle flux and low electron temperature. To measure electron density and elec... As advanced linear plasma sources, cascaded arc plasma devices have been used to generate steady plasma with high electron density, high particle flux and low electron temperature. To measure electron density and electron temperature of the plasma device accurately, a laser Thomson scattering(LTS) system, which is generally recognized as the most precise plasma diagnostic method, has been established in our lab in Dalian University of Technology. The electron density has been measured successfully in the region of 4.5?×10^19m^-3 to7.1?×10^20m^-3 and electron temperature in the region of 0.18 eV to 0.58 eV. For comparison,an optical emission spectroscopy(OES) system was established as well. The results showed that the electron excitation temperature(configuration temperature) measured by OES is significantly higher than the electron temperature(kinetic electron temperature) measured by LTS by up to 40% in the given discharge conditions. The results indicate that the cascaded arc plasma is recombining plasma and it is not in local thermodynamic equilibrium(LTE). This leads to significant error using OES when characterizing the electron temperature in a non-LTE plasma. 展开更多
关键词 laser Thomson scattering optical emission spectroscopy cascaded arc plasma electron density electron temperature electron excitation temperature
下载PDF
Numerical Simulation of Ion Extraction Through Ion Thruster Optics 被引量:1
19
作者 钟凌伟 刘宇 +1 位作者 温正 任军学 《Plasma Science and Technology》 SCIE EI CAS CSCD 2010年第1期103-108,共6页
Based on the particle-in-cell (PIC) method, a two-dimensional numerical scheme was developed to investigate the ion beam extraction phenomena through the ion thruster optics. According to the calculated results, the... Based on the particle-in-cell (PIC) method, a two-dimensional numerical scheme was developed to investigate the ion beam extraction phenomena through the ion thruster optics. According to the calculated results, the plasma sheath upstream of the screen grid, the electric field in the calculation domain, and the ion and electron spatial distributions are obtained for different accelerator grid voltages. The results indicate that the accelerator grid voltage affects the plasma sheath upstream of the screen grid significantly. It is found that a moderate accelerator grid voltage results in an ion optical performance better than either a higher or lower voltage, from a point of ion extraction from the discharge chamber and erosion mitigation of the accelerator grid due to the direct ion impingement. 展开更多
关键词 electric propulsion ion thruster ion optics particle simulation plasma sheath
下载PDF
Time-Resolved Optical Emission Spectroscopy Diagnosis of CO_2 Laser-Produced SnO_2 Plasma 被引量:1
20
作者 兰慧 王新兵 左都罗 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第9期902-906,共5页
The spectral emission and plasma parameters of SnO2 plasmas have been investigated. A planar ceramic SnO2 target was irradiated by a CO2 laser with a full width at half maximmn of 80 ns. The temporal behavior of the s... The spectral emission and plasma parameters of SnO2 plasmas have been investigated. A planar ceramic SnO2 target was irradiated by a CO2 laser with a full width at half maximmn of 80 ns. The temporal behavior of the specific emission lines from the SnO2 plasma was characterized. The intensities of Sn I and Sn Ⅱ lines first increased, and then decreased with the delay time. The results also showed a faster decay of Sn I atoms than that of Sn II ionic species. The temporal evolutions of the SnO2 plasma parameters (electron temperature and density) were deduced. The measured temperature and density of SnO2 plasma are 4.38 eV to 0.5 eV and 11.38×1017 cm 3 to 1.1×1017^ cm-3, for delay times between 0.1 μs and 2.2 #s. We also investigated the effect of the laser pulse energy on Sn02 plasma. 展开更多
关键词 optical emission spectroscopy laser produced plasma C02 laser electrontemperature electron density
下载PDF
上一页 1 2 74 下一页 到第
使用帮助 返回顶部