Estimated Average Glandular Dose for 1,828 Mammography Procedures in China: A Multicenter Study 被引量:2
1
作者 DU Xiang WANG Jin ZHU Bao Li 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2019年第4期242-249,共8页
Objective To understand the distribution of the average glandular dose(AGD) in mammography by investigating 1,828 exposure parameters of 8 mammography machines in three cities, by using random sampling. Methods A surv... Objective To understand the distribution of the average glandular dose(AGD) in mammography by investigating 1,828 exposure parameters of 8 mammography machines in three cities, by using random sampling. Methods A survey of 8 mammography machines in three different cities, sampled using stratified random sampling methods, was performed, and 1,828 mammography exposure parameters were recorded. Incident air kerma(k) was measured by Quality-Assurance(QA) dosimeters, and AGD was calculated by series conversion coefficients based on a 3D detailed Monte Carlo breast model, published by Wang et al. Results The distribution of compressed breast thickness(CBT) fitted a normal distribution, while that of AGD fitted a skewed distribution. The mean value of CBT in a medio-lateral oblique(MLO) view was about 5.6% higher than that in the craniocaudal(CC) view, with significant statistical difference; mean value of AGD and CBT in the sample was 1.3 mGy and 4.6 cm, respectively. The AGD trended upward with increasing CBT, similar to the results of other researches. Conclusion The mean AGD and CBT levels in our study for mammography practice in China were 1.3 mGy and 4.6 cm, respectively. AGD is influenced by manufacturer-specific variation as machine response to CBT changes and target/filter combination. The present study can provide evidence for establishing a diagnostic reference level in China. 展开更多
关键词 Medical radiation mammography Compressed BREAST thickness AVERAGE GLANDULAR DOSE
下载PDF
Quantification of the Pain and Physical Burden Experienced during Positioning for Craniocaudal Imaging in Mammography, Evaluated by Measurement of Muscle Activity 被引量:3
2
作者 Mieko Uchiyama Yongbum Lee +2 位作者 Kiyoko Kazama Yasuko Minagawa Masaki Tsurumaki 《Health》 2015年第1期23-34,共12页
Mammography is carried out in a special position, i.e. “an image is taken while the breast is compressed, stretched and kept in a fixed position”. The purpose of this study was to demonstrate quantitatively and qual... Mammography is carried out in a special position, i.e. “an image is taken while the breast is compressed, stretched and kept in a fixed position”. The purpose of this study was to demonstrate quantitatively and qualitatively the physical and psychological burden due to positioning and breast compression during mammography. Muscle activity of each part of the body during positioning for the standard imaging method, to obtain craniocaudal (CC) view images, was measured in 15 adult females using surface EMG. The associated pain was analyzed using visual analogue scale (VAS) scores. During positioning for the CC view, muscle activity was highest in the biceps (24.44 iEMG/s) followed by the trapezius (17.78 iEMG/s) on the imaging side. Muscle activity of the biceps and the sternocleidomastoid on the imaging side showed significant differences compared with pre-imaging activity (biceps P < 0.031, sternocleidomastoid P < 0.005). The pain during mammography was rated as moderate to severe pain (VAS = 3.3 - 6.7) for CC views. As a result, the activities of not only the muscles directly involved in mammography positioning but also those indirectly involved were high as compared with the normal state. Measurement of muscle activity during mammography is expected to be used effectively, such as in the care to reduce pain for the subjects. 展开更多
关键词 mammography Muscle Activity PHYSICAL PAIN Surface ELECTROMYOGRAPHY Visual ANALOGUE Scale
下载PDF
The Experience of Mammography Based on the Memoirs of Examinees 被引量:2
3
作者 Mieko Uchiyama 《Health》 2014年第11期1310-1314,共5页
The purpose of this study was to shed light on the pattern of the mammography experience from the examinee’s perspective based on episodic information extracted from notes written by the examinees. Using the notes is... The purpose of this study was to shed light on the pattern of the mammography experience from the examinee’s perspective based on episodic information extracted from notes written by the examinees. Using the notes is an effective approach to maintain privacy and avoid excessive stress. The study methods were qualitative inductive analyses of four sets of notes. Results showed that examinees “checked the words and actions of the medical staff” while relying on the “peace of mind instilled by the technician” before taking the mammogram. However, as breast compression became more intense, their feelings changed to a sense of “betrayal by someone on whom they were relying” since they felt that the technician was “ignoring the situation” or “considering but continuing breast compression”. They were also affected by the “shooting position which is impossible to avoid”. Breast compression during the mammography was a “pressure pain that exceeded their expectations” causing “dissatisfaction with the screening as a result of the pain” and “subconsciously created systemic tension”. Meanwhile, during the shooting, the examinees had performed “quiet countermeasures” such as “self-coping to distract themselves from the pain”. Examinees “earnestly desired a minimal shooting time” but, on the other hand, they also wanted “certainty of shooting rather than consideration of pain”. From these results, it is apparent that examinees were objectively observing the staff, even during shooting and the examinees were using self-coping measures to counter the pain. Providing support measures during mammography procedures is suggested based on the patterns of experiences. 展开更多
关键词 BREAST CANCER mammography SCREENING
下载PDF
Detection and classification of breast lesions using multiple information on contrast-enhanced mammography by a multiprocess deep-learning system: A multicenter study 被引量:4
4
作者 Yuqian Chen Zhen Hua +16 位作者 Fan Lin Tiantian Zheng Heng Zhou Shijie Zhang Jing Gao Zhongyi Wang Huafei Shao Wenjuan Li Fengjie Liu Simin Wang Yan Zhang Feng Zhao Hao Liu Haizhu Xie Heng Ma Haicheng Zhang Ning Mao 《Chinese Journal of Cancer Research》 SCIE CAS CSCD 2023年第4期408-423,共16页
Objective: Accurate detection and classification of breast lesions in early stage is crucial to timely formulate effective treatments for patients. We aim to develop a fully automatic system to detect and classify bre... Objective: Accurate detection and classification of breast lesions in early stage is crucial to timely formulate effective treatments for patients. We aim to develop a fully automatic system to detect and classify breast lesions using multiple contrast-enhanced mammography(CEM) images.Methods: In this study, a total of 1,903 females who underwent CEM examination from three hospitals were enrolled as the training set, internal testing set, pooled external testing set and prospective testing set. Here we developed a CEM-based multiprocess detection and classification system(MDCS) to perform the task of detection and classification of breast lesions. In this system, we introduced an innovative auxiliary feature fusion(AFF)algorithm that could intelligently incorporates multiple types of information from CEM images. The average freeresponse receiver operating characteristic score(AFROC-Score) was presented to validate system’s detection performance, and the performance of classification was evaluated by area under the receiver operating characteristic curve(AUC). Furthermore, we assessed the diagnostic value of MDCS through visual analysis of disputed cases,comparing its performance and efficiency with that of radiologists and exploring whether it could augment radiologists’ performance.Results: On the pooled external and prospective testing sets, MDCS always maintained a high standalone performance, with AFROC-Scores of 0.953 and 0.963 for detection task, and AUCs for classification were 0.909[95% confidence interval(95% CI): 0.822-0.996] and 0.912(95% CI: 0.840-0.985), respectively. It also achieved higher sensitivity than all senior radiologists and higher specificity than all junior radiologists on pooled external and prospective testing sets. Moreover, MDCS performed superior diagnostic efficiency with an average reading time of 5 seconds, compared to the radiologists’ average reading time of 3.2 min. The average performance of all radiologists was also improved to varying degrees with MDCS assistance.Conclusions: MDCS demonstrated excellent performance in the detection and classification of breast lesions,and greatly enhanced the overall performance of radiologists. 展开更多
关键词 Deep learning contrast-enhanced mammography breast lesions DETECTION CLASSIFICATION
下载PDF
Clinical study of digital mammography,contrast-enhanced MRI as well as their combination in the diagnosis of breast cancer 被引量:3
5
作者 Fang Ye Mengsu Zeng Fuhua Yan Wei Feng Meiling Zhou Renchen Li Wenfang Chen 《The Chinese-German Journal of Clinical Oncology》 CAS 2008年第5期286-291,共6页
Objective: To compare the effectiveness of digital mammography and MRI in the detection and diagnosis of breast cancer and to assess the value of these modalities as well as the combination of the two. Methods: Sixt... Objective: To compare the effectiveness of digital mammography and MRI in the detection and diagnosis of breast cancer and to assess the value of these modalities as well as the combination of the two. Methods: Sixty-seven patients with surgery and pathology proved breast lesion (malignant, n = 32; benign, n = 46) underwent digital mammography and MRI, the pulse sequences included T1WI, T2WI, diffuse weighted imaging (DWI), and dynamic contrast-enhanced MRI before surgery. Of the results of these two modalities, all lesions were classified into 5 groups according to BI-RADS classification, and the imaging findings were correlated to histopathology. The sensitivity and specificity of each modality as well as the combination of the two were calculated. Results: Of these 78 breasts lesions, The sensitivity was 78.13%% (25/32) for digital mammography and 93.75% (30/32) for MRI (P 〉 0.05). The specificity was 73.91%% (34/46) and 89.13% (41/46) accordingly (P 〈 0.05), both of them showed statistical difference. The sensitivity and specificity was 98.63% and 97.16% respectively as these two modalities were used in combination. Conclusion: Digital mammography in combination with MRI is helpful in the diagnosis of breast cancer, the sensitivity and specificity was enhanced when compared to that of single modality. 展开更多
关键词 magnetic resonance imaging breast neoplasms mammography
下载PDF
Efficacy of Magnetic Resonance Imaging in BIRADS 3, 4 and 5 Patients Detected on Full Field Digital Mammography: Our Experience 被引量:1
6
作者 Atul Patil Samadhan Pawar +1 位作者 Raj Nagarkar Bhargav Gaikwad 《Open Journal of Clinical Diagnostics》 2019年第1期33-49,共17页
Aim of the study: To perform Dynamic contrast enhanced MRI of breast in patients with positive findings (BIRADS 3, 4 and 5) detected on screening mammography;to correlate the findings of digital mammography and contra... Aim of the study: To perform Dynamic contrast enhanced MRI of breast in patients with positive findings (BIRADS 3, 4 and 5) detected on screening mammography;to correlate the findings of digital mammography and contrast enhanced MRI of breast with histopathological examinations. Settings and Design: A prospective observation study was conducted at a single centre, i.e. HCG Manavata Cancer Centre. Materials and Methods: Screening mammography was performed on patients with age > 40 years and on patients with age 35 - 40 years having positive family history. The positive mammography was reported and the lesions classified according to BIRADS criteria for mammography. Results: Mammographic examination of the breast lesions yielded an overall sensitivity of 97.67% and a specificity of 85.71%. In our study we combined both morphologic and dynamic parameters and its modification into BIRADS category for lesion classification. The sensitivity of MRI examinations was 97.67% while the specificity was 71.43%. Spiculated margins were encountered only in malignant lesions (p = 0.0006). Statistical correlation was obtained between the pathologically proven benign and malignant lesions regarding their enhancement pattern with p value of Conclusion: As per the results, dynamic contrast MRI had high sensitivity but limited specificity. We did not find any significant difference between FFDM and MRI in terms of diagnostic accuracy. The use of DWI showed high specificity at cut off point of ADC value—0.85 mm2/s. Thus, DWI can be used in addition of morphological and dynamic kinetic characteristics to increase specificity of MRI. 展开更多
关键词 BREAST Cancer Screening mammography Magnetic Resonance Imaging
下载PDF
Content-based image retrieval applied to BI-RADS tissue classification in screening mammography 被引量:1
7
作者 Júlia Epischina Engrácia de Oliveira Arnaldo de Albuquerque Araújo Thomas M Deserno 《World Journal of Radiology》 CAS 2011年第1期24-31,共8页
AIM:To present a content-based image retrieval(CBIR) system that supports the classification of breast tissue density and can be used in the processing chain to adapt parameters for lesion segmentation and classificat... AIM:To present a content-based image retrieval(CBIR) system that supports the classification of breast tissue density and can be used in the processing chain to adapt parameters for lesion segmentation and classification.METHODS:Breast density is characterized by image texture using singular value decomposition(SVD) and histograms.Pattern similarity is computed by a support vector machine(SVM) to separate the four BI-RADS tissue categories.The crucial number of remaining singular values is varied(SVD),and linear,radial,and polynomial kernels are investigated(SVM).The system is supported by a large reference database for training and evaluation.Experiments are based on 5-fold cross validation.RESULTS:Adopted from DDSM,MIAS,LLNL,and RWTH datasets,the reference database is composed of over 10000 various mammograms with unified and reliable ground truth.An average precision of 82.14% is obtained using 25 singular values(SVD),polynomial kernel and the one-against-one(SVM).CONCLUSION:Breast density characterization using SVD allied with SVM for image retrieval enable the development of a CBIR system that can effectively aid radiologists in their diagnosis. 展开更多
关键词 COMPUTER-AIDED diagnosis CONTENT-BASED IMAGE retrieval IMAGE processing Screening mammography SINGULAR value decomposition Support vector machine
下载PDF
Pupil Size Measurement and Sucrose Ingestion for Quantifying and Decreasing Burden of Women during Mammography 被引量:1
8
作者 Yongbum Lee Mieko Uchiyama Tomoko Sumiyoshi 《Journal of Biomedical Science and Engineering》 2015年第10期700-706,共7页
Many women feel a physical burden, which usually appears as a pain, during mammography. We examined the pain-related pupil dilation response during mammography. Twenty-four healthy women participated in the examinatio... Many women feel a physical burden, which usually appears as a pain, during mammography. We examined the pain-related pupil dilation response during mammography. Twenty-four healthy women participated in the examination. They were randomly assigned to water group or sucrose group. Water group and sucrose group ingested distilled water and a sucrose solution during mammography, respectively. Their pupil sizes were measured during mammography excluding X-ray irradiation. The subjective intensity of pain during mammography was also assessed using visual analogue scales (VAS). The mean pupil diameter was 2.99 mm in relaxation phase before mammography, while it was 3.15 mm in a few seconds after breast compression (pressure phase). The difference between the two was statistically significant (p p < 0.01). These results suggest that we may be able to assess objectively the degree of pain associated with mammography and sweet taste stimuli may be effective to alleviate a women’s burden received during mammography. 展开更多
关键词 mammography PAIN Assessment PAIN Alleviation PUPIL DILATION Sweet Stimuli
下载PDF
Solid neuroendocrine breast carcinoma:mammographic and sonographic features in thirteen cases 被引量:7
9
作者 Jing Wu Qiu-Xia Yang +7 位作者 Yao-PanWu De-Ling Wang Xue-Wen Liu Chun-Yan Cui Ling Wang Yao Chen Chuan-Miao Xie Rong Zhang 《Chinese Journal of Cancer》 SCIE CAS CSCD 2012年第11期549-556,共8页
This study aimed to determine and quantitate the mammographic and sonographic characteristics in 13 cases of solid neuroendocrine breast carcinoma(NEBC) and to analyze the association of radiological findings with the... This study aimed to determine and quantitate the mammographic and sonographic characteristics in 13 cases of solid neuroendocrine breast carcinoma(NEBC) and to analyze the association of radiological findings with the clinical and histopathologic findings.The clinical data and imaging findings of 13 female patients with histologically confirmed solid NEBC were reviewed.Imaging data were evaluated by two radiologists for a consensual diagnosis.All patients presented with one palpable mass;only 1 experienced occasional breast pain,and 5 complained of fluid discharge.In 7 patients,the masses were firm and mobile.Regional lymph node metastasis was noted in only 1 patient.For the 10 patients who underwent mammography,6 had a mass,1 had clustered small nodules with clustered punctuate microcalcifications,2 had asymmetric focal density,and 1 had solitary punctuate calcification.Most of the masses had irregular shape with indistinct or microlobulated margins.For the 9 patients who underwent ultrasonography(US),9 masses were depicted,all of which were hypoechoic,mostly with irregular shape and without acoustic phenomena.Different types of acoustic phenomena were also identified.One patient had developed distant metastases during follow-up.NEBC has a variety of presentations,but it is mostly observed on mammograms as a dense,irregular mass with indistinct or microlobulated margins.Sonographically,it typically presents as an irregular,heterogeneously hypoechoic mass with normal sound transmission.Histories of nipple discharge and calcification observed using imaging are not rare. 展开更多
关键词 神经内分泌 超音波 乳腺癌 乳房 摄影 固体 不规则形状 临床资料
下载PDF
Comparison between Visualization of Microcalcifications by Digital Breast Tomosynthesis and Full-Field Digital Mammography 被引量:1
10
作者 Ryusuke Murakami Hitomi Tani +3 位作者 Izumi Miki Tamiko Yoshida Shinichiro Kumita Nachiko Uchiyama 《Open Journal of Radiology》 2020年第2期90-100,共11页
<strong>Objective:</strong> To date, few studies have compared the diagnostic performance and visibility of microcalcifications obtained using digital breast tomosynthesis (DBT) with those obtained from fu... <strong>Objective:</strong> To date, few studies have compared the diagnostic performance and visibility of microcalcifications obtained using digital breast tomosynthesis (DBT) with those obtained from full-field digital mammography (FFDM). The visualization and characterization of microcalcifications with DBT remain controversial. The purpose of this study was to compare the visibility of microcalcifications and determine whether DBT exhibits a diagnostic advantage for visualizing microcalcifications over FFDM.<strong> Methods: </strong>We retrospectively reviewed 120 cases including DBT and FFDM imaging (60 histologically verified as breast cancers and 60 as benign microcalcifications or normal). DBT images with a wide scan-angle of 50<span style="white-space:nowrap;"><span style="white-space:nowrap;">&deg;</span></span> and FFDM images were obtained using a flat-panel system (MAMMOMAT Inspiration, Siemens). Images were independently reviewed by four board-certified radiologists and evaluated for the presence of microcalcifications, probability of malignancy (BI-RADS classification), and visibility. <strong>Results:</strong> In predicting the malignancy of detected microcalcifications, no significant difference was found between readers’ areas under the receiver operating characteristic curve for DBT and FFDM (p = 0.068). The visibility scores of detected microcalcifications were 3.74 <span style="white-space:nowrap;"><span style="white-space:nowrap;"><span style="white-space:nowrap;">&plusmn;</span></span></span> 1.06 for DBT and 3.46 <span style="white-space:nowrap;"><span style="white-space:nowrap;"><span style="white-space:nowrap;">&plusmn;</span></span></span> 0.93 for FFDM, respectively. The visibility of microcalcifications when using DBT was found to be significantly superior to that of FFDM (p < 0.05). <strong>Conclusion:</strong> Our results suggest that the image quality of DBT with a wide scan-angle is comparable or superior to that obtained with FFDM in terms of both visibility and assessment of microcalcifications. 展开更多
关键词 BREAST Breast Cancer MICROCALCIFICATIONS Digital mammography Digital Breast Tomosynthesis
下载PDF
Evaluation of Breast Masses Using Mammography and Sonography as First Line Investigations 被引量:1
11
作者 Kishor Taori Suresh Dhakate +5 位作者 Jawahar Rathod Anand Hatgaonkar Amit Disawal Prasad Wavare Vishal Bakare Rakhi P. Puri 《Open Journal of Medical Imaging》 2013年第1期40-49,共10页
Purpose: To study the specificity of mammography and ultrasonography separately and in combination for detection of breast masses (ultrasonography-mammography correlation);To study the investigations to evaluate vario... Purpose: To study the specificity of mammography and ultrasonography separately and in combination for detection of breast masses (ultrasonography-mammography correlation);To study the investigations to evaluate various breast masses;To describe suitable indications, advantages and limitations of each technique compared with other available modalities;To study the mimics of breast masses;To have histopathology follow-up and retrospective evaluation with imaging findings to improve diagnostic skills in series of 166 patients complaining of breast mass. Material: The prospective clinical study was carried out in the department of Radiodiagnosis for a period of 2 year extending from December 2010 to December 2012 infemale patients complaining of breast mass. Well informed written consent was obtained from them. Histopathology follow up was obtained from either biopsy or post operative tissue. USG machine: Philips HD 11 XE USG of the breasts and axillary region done in supine position in presence of female attendant;Mammography machine: Allengers machine with Agfa special mammography cassettes. Cranio caudal and Medio-Lateral Oblique views are taken in the presence of female attendant. MRI: PHILIPS 1.5 T machine;CT: SIEMENS duel slice CT machine. Results: Ultrasonography and mammography was done in most of the cases were sufficient to diagnose the lesion in most of the cases especially in benign breast masses. MRI and CT scan was used in special cases to know the extent of the lesions, in mimics of breast masses, bony extensions, primary muscular and bony lesions. Total 166 patients complaining of breast mass in one or both breasts were examined and evaluated with USG and mammography. The lesions were confirmed on histopathology (FNAC/biopsy). Out of 30 diagnosed malignancies two lesions were missed on mammography and four lesions were missed on ultrasonography. One of them was missed on both. For malignancies specificity of mammography is 93.3% and that of ultrasonography is 86.67%. Combining both the modalities specificity is near 97%. Out of total 92 abnormal breasts 12 were missed on USG and 20 were missed on mammography. Combining both the modalities only 2 lesions were missed and were diagnosed on histopathology alone. Overall specificity for USG in breast masses is 86.9% and for mammography it is 78.6%. Combining both the modalities the specificity is 97.6%. The “p” value is obtained which is highly significant for combination of ultrasonography and mammography in comparison with any individual modality (p = 0.0059 & p = 0.0001 respectively). Conclusion: Our study confirms the higher combined sensitivity rate for ultrasonography and mammography for detection of breast masses including malignancies. USG is useful in cystic lesions, ectasias, infections, pregnancy-lactation, and dense breast evaluation and for image guidance, whereas mammography is useful in detecting microcalcifications, spiculated masses for early detection of malignancies and for stereotactic biopsies. To suggest single modality, ultrasonography is better in younger population and BIRAD 1, 2 & 3 lesions. Whereas, mammography is better in older population and BIRAD 4 & 5 lesions. However, sono-mammographic correlation is best in both. 展开更多
关键词 BREAST MASSES ULTRASONOGRAPHY mammography MIMICS Correlation
下载PDF
Using a Wavelet-Based and Fine-Tuned Convolutional Neural Network for Classification of Breast Density in Mammographic Images 被引量:1
12
作者 Eri Matsuyama Megumi Takehara Du-Yih Tsai 《Open Journal of Medical Imaging》 2020年第1期17-29,共13页
Classification of breast density is significantly important during the process of breast diagnosis. The purpose of this study was to develop a useful computer-ized tool to help radiologists determine the patient’s br... Classification of breast density is significantly important during the process of breast diagnosis. The purpose of this study was to develop a useful computer-ized tool to help radiologists determine the patient’s breast density category on the mammogram. In this article, we presented a model for automatically classi-fying breast densities by employing a wavelet transform-based and fine-tuned convolutional neural network (CNN). We modified a pre-trained AlexNet model by removing the last two fully connected (FC) layers and appending two newly created layers to the remaining structure. Unlike the common CNN-based methods that use original or pre-processed images as inputs, we adopted the use of redundant wavelet coefficients at level 1 as inputs to the CNN model. Our study mainly focused on discriminating between scattered density and heterogeneously dense which are the two most difficult density cat-egories to differentiate for radiologists. The proposed system achieved 88.3% overall accuracy. In order to demonstrate the effectiveness and usefulness of the proposed method, the results obtained from a conventional fine-tuning CNN model was compared with that from the proposed method. The results demon-strate that the proposed technique is very promising to help radiologists and serve as a second eye for them to classify breast density categories in breast cancer screening. 展开更多
关键词 mammography MAMMARY GLAND Density CNN WAVELET TRANSFORM
下载PDF
Correlativity study on mammographic features and c-erbB-2 of breast cancer 被引量:1
13
作者 Jie Ma Min Zuo Guoping Sun Da Zang Xiaomei Wang Jianmin Xu 《The Chinese-German Journal of Clinical Oncology》 CAS 2006年第5期350-353,共4页
Objective: To investigate the correlativity between mammographic features and c-erbB-2 of breast cancer. Meth- ods: The mammographic features of 165 patients, including calcification, distinct, esion concentration, br... Objective: To investigate the correlativity between mammographic features and c-erbB-2 of breast cancer. Meth- ods: The mammographic features of 165 patients, including calcification, distinct, esion concentration, breast cysitic hyperplasia accompanied, were studied comparatively with c-erbB-2 gene stained with immunohistochemical technique. Results: Of 165 cases, calcification impression was 84 cases (50.91%), indistinct 80 cases (48.40%), lesions were concentrated of 87 case (52.73%), accompanied breast cysitic hyperplasia 85 cases (51.52%). Conclusion: Mammographic features of breast cancer could show the status of c-erbB-2, the positive chance is higher with calcification, indistinct, lesion concentration and accompa- nied breast cysitic hyperplasia. 展开更多
关键词 breast neoplasms mammography molecular biology c-erbB-2 gene
下载PDF
Optical mammography:Diffuse optical imaging of breast cancer 被引量:1
14
作者 Kijoon Lee 《World Journal of Clinical Oncology》 CAS 2011年第1期64-72,共9页
Existing imaging modalities for breast cancer screening,diagnosis and therapy monitoring,namely X-ray mammography and magnetic resonance imaging,have been proven to have limitations.Diffuse optical imaging is a set of... Existing imaging modalities for breast cancer screening,diagnosis and therapy monitoring,namely X-ray mammography and magnetic resonance imaging,have been proven to have limitations.Diffuse optical imaging is a set of non-invasive imaging modalities that use near-infrared light,which can be an alternative,if not replacement,to those existing modalities.This review covers the background knowledge,recent clinical outcome,and future outlook of this newly emerging medical imaging modality. 展开更多
关键词 DIFFUSE OPTICAL imaging DIFFUSE OPTICAL spectroscopy BREAST cancer OPTICAL mammography THERAPY monitoring
下载PDF
Mammography combined with breast dynamic contrast-enhanced-magnetic resonance imaging for the diagnosis of early breast cancer 被引量:4
15
作者 Yakun He Guohui Xu +4 位作者 Jin Ren Bin Feng Xiaolei Dong Hao Lu Changjiu He 《Oncology and Translational Medicine》 2016年第4期165-168,共4页
Objective The aim of this study was to investigate the application of mammography combined with breast dynamic contrast-enhanced magnetic resonance imaging(DCE-MRI) for the diagnosis of early breast cancer. Methods Ma... Objective The aim of this study was to investigate the application of mammography combined with breast dynamic contrast-enhanced magnetic resonance imaging(DCE-MRI) for the diagnosis of early breast cancer. Methods Mammography and DCE-MRI were performed for 120 patients with breast cancer(malignant, 102; benign; 18). Results The sensitivity of mammography for early diagnosis of breast cancer was 66.67%, specificity was 77.78%, and accuracy was 68.33%. The sensitivity of MRI for early diagnosis of breast cancer was 94.12%, specificity was 88.89%, and accuracy was 93.33%. However, the sensitivity of mammography combined with DCE-MRI volume imaging with enhanced water signal(VIEWS) scanning for early diagnosis of breast cancer was 97.06%, specificity was 94.44%, and accuracy was 96.67%. Conclusion Mammography combined with DCE-MRI increased the sensitivity, specificity, and accuracy of diagnosing early breast cancer. 展开更多
关键词 breast carcinoma mammography nuclear magnetic resonance dynamic enhancement time signal curve
下载PDF
BI-RADS CATEGORIZATION AND POSITIVE PREDICTIVE VALUE OF MAMMOGRAPHIC FEATURES
16
作者 唐瑞英 高文 +2 位作者 马丽华 林本耀 徐光炜 《Chinese Journal of Cancer Research》 SCIE CAS CSCD 2001年第3期202-205,共4页
Objective: To determine whether the categories defined in the Breast Imaging Reporting and Data System (BI-RADS) are useful predictors of malignancy. Methods: A total of 348 cases with benign and malignant breast dise... Objective: To determine whether the categories defined in the Breast Imaging Reporting and Data System (BI-RADS) are useful predictors of malignancy. Methods: A total of 348 cases with benign and malignant breast diseases were collected. Mammographic and pathologic findings were reviewed. Mammograms of 348 cases were characterized according to BI-RADS descriptors and were categorized by the final assessment categories. Results: Of the all 348 patients, 232 (67%) were carcinomas. Significantly more masses with calcification and speculation were found in breast cancers than in benign breast diseases. BI-RADS final assessment categories were category 2 and 3 in 106 cases, in which 75% (79/106) were benign; category 4 and 5 in 242 cases, in which 85% (205/242) were carcinomas. BI-RADS categories 4 and 5 are useful predictors of relative likelihood of malignancy. The features with higher positive predictive values for carcinomas were irregular shape, indistinct or speculated margins, fine or linear calcification morphology, and regional calcification distribution. Conclusion: BI-RADS lexicon is successful in providing a standardized language for physicians to describe lesion morphology. BI-RADS category is useful for predicting the presence of malignancy. 展开更多
关键词 Breast cancer mammography BI-RADS
下载PDF
THE MAMMOGRAPHIC CALCIFICATIONS IN BREAST CANCER
17
作者 唐瑞英 刘静贤 高文 《Chinese Journal of Cancer Research》 SCIE CAS CSCD 1998年第3期61-63,共3页
Objective: This study was performed to exam the relativeship between mammographic calcifications and breast cancer. Methods: All of the 184 patients with breast diseases underwent mammography before either an open ... Objective: This study was performed to exam the relativeship between mammographic calcifications and breast cancer. Methods: All of the 184 patients with breast diseases underwent mammography before either an open biopsy or a mastectomy. The presence, morphology, and distribution of calcifications visualized on mammograms for breast cancer were compared with the controls who remained cancer free. Statistical comparisons were made by using the x 2 test. Results: Of the 184 patients with breast diaeases, 93 malignant and 91 benign lesions were histologically confirmed. Calcifications were visualized on mammograms in 60 (64%)of 93 breast cancers and 26(28%)of 91 non breast cancers. The estimated odds ratio (OR) of breast cancer was 4.5 in women with calcifications seen on mammo grams, compared with those having none ( P < 0.01). Of the 60 breast carcinomas having mammographic calcifi cations, 28 (47%) were infiltrating ductal carcinomas. There were only 8 (24%) cases with infiltrating ductal cancers in the group of without calcifications seen on the mammograms ( P <0.05). Conclusion: Our finding sug gests that mammographic calcification appears to be a risk factor for breast cancer. The granular and linear cast type calcification provide clues to the presence of breast cancer, especially when the carcinomas without associated masses were seen on mammograms. 展开更多
关键词 Breast neoplasms mammography Imaging diagnosis
下载PDF
COMPARISON OF INFRARED LIGHTSCANNING AND MAMMOGRAPHY IN BREAST CANCER DETECTION
18
作者 唐瑞英 胡永升 徐光炜 《Chinese Journal of Cancer Research》 SCIE CAS CSCD 1995年第4期308-310,共3页
Purpose: This study is in an attempt to assess the diagnostic accuracy of infrared lightscanning by comparing with that of mammograpby- Methods: A total of 104 patients had been examined by both mammography and infrar... Purpose: This study is in an attempt to assess the diagnostic accuracy of infrared lightscanning by comparing with that of mammograpby- Methods: A total of 104 patients had been examined by both mammography and infrared lightscanning before surgery.All Patients were divided into two groups: cancer and non cancer. The diagnostic accuracy of these two modalities were calculated. Results: Of 104 Patients, 43 had breast cancer and 61 had benign lesions, the sensitivity and specificity for mammography were 84% and 83%, 82% and 77% for infrared lightscanning. The predictive values of positivity for mammograpby and lightscanning were 80% and 70%, the negative Predictive value for these two modalities were both 87%. Conclusion: Infrared lightscanning,being of assistance to mammography, could enhance sensitivity and predictive values of positivity in detecting breast cancer, especially, in mammographically dense breast. 展开更多
关键词 breast neoplasm mammography Imaging diagnosis Evaluation study
下载PDF
Effects of mammography positioning on the autonomic nervous function
19
作者 Mieko Uchiyama Yongbum Lee +2 位作者 Mieko Sadakata Du-Yih Tsai Mitsuko Sayama 《Health》 2013年第8期1335-1341,共7页
The physical and psychological burden on patients during mammography was analyzed using the autonomic function index in 34 adult females. The indices included heart rate (HR), high frequency (HF) of the R-R interval o... The physical and psychological burden on patients during mammography was analyzed using the autonomic function index in 34 adult females. The indices included heart rate (HR), high frequency (HF) of the R-R interval on an electrocardiogram, and the ratio of HF to LF (low frequency) (LF/HF). HR is an indicator of the degree of mental and physical activity, HF indicates the parasympathetic index and LF/HF indicates the sympathetic index. For the mediolateral oblique (MLO) view in mammography, autonomic function indices were measured before and during mammography. Statistical analysis was performed by the Mann-Whitney U test and the significance level was set at 5%. The autonomic function indices were compared before and during mammography and all showed no significant differences. The average value before imaging and the reference value at rest were compared. The results showed that HR increased 1.3-fold, HF increased 0.4-fold, and LF/HF increased 3.2-fold over reference values. Chronological changes during mammography showed that HF increased and LF/HF decreased from 120 seconds after the start of imaging. From these observations, it is evident that the state before mammography is not the same as the resting state and that the sympathetic index is dominant before imaging. They also suggest that some aspects of the psychological burden experienced during mammography are not due to the pain of breast compression alone. 展开更多
关键词 mammography PHYSICAL and PSYCHOLOGICAL BURDEN AUTONOMIC Nervous Function
下载PDF
Initial Experience with Contrast Enhanced Digital Mammography (SenoBright)—In a Comprehensive Clinical Breast Center
20
作者 Robert L. Elliott Catherine C. Baucom +2 位作者 Mary C. Elliott Emorly H. Millet Xianpeng Jiang 《Journal of Cancer Therapy》 2017年第2期146-154,共9页
Objective: The purpose of initiating contrast enhanced digital mammography in our center was to evaluate the complimentary benefit of this technology with screening digital mammography and real time ultrasound in equi... Objective: The purpose of initiating contrast enhanced digital mammography in our center was to evaluate the complimentary benefit of this technology with screening digital mammography and real time ultrasound in equivocal cases and high risk patients with dense breast. The intended goal was to reduce the incidence of further diagnostic and invasive procedures. Methods: Patients thought to be candidates who had good renal function confirmed by serum Blood Urea Nitrogen (BUN) and Creatinine were offered the procedure, and 225 patients had the procedure during the period of March 2013 through November 2014. The contrast enhanced digital mammograms (SenoBright) are performed on the Senograph Essential Unit. A total of 8 images are obtained: 4 conventional digital mammograms and 4 contrast enhanced digital mammograms. The patients with a positive SenoBright study had a tissue diagnosis of the lesion obtained by either a stereotactic needle biopsy, ultrasound guided core biopsy, or ultrasound directed open excisional biopsy. Results: The 225 patients who had the procedure included high risk patients with dense breast (41), patients with abnormal mammograms (92), and patients with equivocal clinical, mammographic and real time ultrasound findings (92). 31 studies were interpreted as positive and 194 as negative. 33 biopsies were performed, with 31 patients having a positive study and 2 patients with a negative study. 22 cancers were detected. Conclusion: We found that the addition of dynamic contrast enhanced digital subtraction mammography (SenoBright) was helpful in distinguishing malignant from non-malignant lesions. It was also effective in demonstrating multifocal lesions and identifying non-palpable occult carcinomas in the dense breast. It proved to be a valuable complimentary adjunctive diagnostic modality for a comprehensive clinical breast center. 展开更多
关键词 BREAST Cancer mammography SenoBright
下载PDF