The diagnosis of water trees of cable insulation is of great importance as the water-treeing is a primary cause of aging breakdown for the middle voltage cables. In this paper, it is described how the water-tree-aged ...The diagnosis of water trees of cable insulation is of great importance as the water-treeing is a primary cause of aging breakdown for the middle voltage cables. In this paper, it is described how the water-tree-aged 10 kV XLPE cables were diagnosed. The cables were subjected to electrical stress of 5.9 kV/mm and a thermal load cycle in a curved water-filled tube for 3, 6 and 12 months of aging in accor- dance with the accelerated water-tree test method. The aged cables were used as the samples for water-tree diagnosis. First, the water-tree degraded cable, was charged by a DC voltage, and then the cable was grounded while a pulse voltage was applied to it for releasing the space charge trapped in the water trees. The amount of the space charge, which corresponds to the deterioration degree of the water trees, was calculated. The effects of DC voltage amplitude, pulse voltage repetition rate and aging conditions on the amount of the space charge were studied. Obtained results show that the amount of the space charge has a positive correlation with the applied DC voltage and the ag- ing time of the cables, and that a peak value of space charge appears with the increase of the pulse voltage repetition rate. An optimum pulse voltage repetition rate under which the space charge can be released rapidly is obtained. Furthermore, the releasing mechanism of space charge by the pulse voltage is discussed. Accumulated results show that the presented method has a high resolution for the diagnosis of water tree degradation degree and is expected to be applied in practice in future.展开更多
Cables that have been in service for over 20 years in Shanghai, a city with abundant surface water, failed more frequently and induced different cable accidents. This necessitates researches on the insulation aging st...Cables that have been in service for over 20 years in Shanghai, a city with abundant surface water, failed more frequently and induced different cable accidents. This necessitates researches on the insulation aging state of cables working in special circumstances. We performed multi-parameter tests with samples from about 300 cable lines in Shanghai. The tests included water tree investigation, tensile test, dielectric spectroscopy test, thermogravimetric analysis (TGA), fourier transform infrared spectroscopy (FTIR), and electrical aging test. Then, we carried out regression analysis between every two test parameters. Moreover, through two-sample t-Test and analysis of va- riance (ANOVA) of each test parameter, we analyzed the influences of cable-laying method and sampling section on the degradation of cable insulation respectively. Furthermore, the test parameters which have strong correlation in the regression analysis or significant differ- ences in the t-Test or ANOVA analysis were determined to be the ones identifying the XLPE cable insulation aging state. The thresholds for distinguishing insulation aging states had been also obtained with the aid of statistical analysis and fuzzy clustering. Based on the fuzzy in- ference, we established a cable insulation aging diagnosis model using the intensity transfer method. The results of regression analysis indicate that the degradation of cable insulation accelerates as the degree of in-service aging increases. This validates the rule that the in- crease of microscopic imperfections in solid material enhances the dielectric breakdown strength. The results of the two-sample t-Test and the ANOVA indicate that the direct-buried cables are more sensitive to insulation degradation than duct cables. This confirms that the tensile strength and breakdown strength are reliable functional parameters in cable insulation evaluations. A case study further indicates that the proposed diagnosis model based on the fuzzy inference can reflect the comprehensive aging state of cable insulation well, and that the cable service time has no correlation with the insulation aging state.展开更多
This paper deals with the experimental study on the correlation betweeninsulation resistance (R) and direct current (DC) component (i_(de)) and corresponding aging degreeof insulation in the course of the aging within...This paper deals with the experimental study on the correlation betweeninsulation resistance (R) and direct current (DC) component (i_(de)) and corresponding aging degreeof insulation in the course of the aging within cross linked polyethylene (XLPE) insulation. Theaging tests were performed on a section of 10 kV transmission XLPE cable by means of water needlemethod, and _R was measured by DC voltage superimposed method, R and i_(de) were found to besignificantly dependent on the correspondingaging degree of insulation in the course of aging ofXLPE, and different kind of aging stage has different characteristics. Beside, there are generallysimilar regularity but different amplitude in the course of aging of XLPE insulation in differentelectrolyte, and the various electrochemical tree were found on the surface of aging XLPE cableimmersed in CuSO_4, solution. Therefore, according to the changing regularity of the DCcharacteristic parameters i. e. R and i_(de) within XLPE insulation judging the aging degree of XLPEinsulation will be an effective method.展开更多
Two commercial crosslinkable polyethylene insulation cable granules, designed for 110 and 35 kV voltage insulation, with similar crosslinking temperature but different melting temperature, were chosen as experimental ...Two commercial crosslinkable polyethylene insulation cable granules, designed for 110 and 35 kV voltage insulation, with similar crosslinking temperature but different melting temperature, were chosen as experimental samples for examining their linear dynamic responses during cross-linking. It has been found that the gel contents of cable compounds for 110 and 35 kV insulation are almost the same after they have been cross-linked at the same temperature, pressure and time. And the sample melts show the similar dependence of the dynamic storage modulus, G; on strain. On the other hand, the dynamic temperature ramp test and the dynamic time sweep test indicate that the samples exhibit different dynamic viscoelastic responses during their crosslinking. An expression for describing their erosslinking process was proposed via probing rheokinetics of crosslinking for the two samples.展开更多
基金Project supported by National Natural Science Foundation of China(51277131), State Key Laboratory Electrical Insulation and Power Equipment, State Key Laboratory Power System (SKLD 11KZ06).
文摘The diagnosis of water trees of cable insulation is of great importance as the water-treeing is a primary cause of aging breakdown for the middle voltage cables. In this paper, it is described how the water-tree-aged 10 kV XLPE cables were diagnosed. The cables were subjected to electrical stress of 5.9 kV/mm and a thermal load cycle in a curved water-filled tube for 3, 6 and 12 months of aging in accor- dance with the accelerated water-tree test method. The aged cables were used as the samples for water-tree diagnosis. First, the water-tree degraded cable, was charged by a DC voltage, and then the cable was grounded while a pulse voltage was applied to it for releasing the space charge trapped in the water trees. The amount of the space charge, which corresponds to the deterioration degree of the water trees, was calculated. The effects of DC voltage amplitude, pulse voltage repetition rate and aging conditions on the amount of the space charge were studied. Obtained results show that the amount of the space charge has a positive correlation with the applied DC voltage and the ag- ing time of the cables, and that a peak value of space charge appears with the increase of the pulse voltage repetition rate. An optimum pulse voltage repetition rate under which the space charge can be released rapidly is obtained. Furthermore, the releasing mechanism of space charge by the pulse voltage is discussed. Accumulated results show that the presented method has a high resolution for the diagnosis of water tree degradation degree and is expected to be applied in practice in future.
基金Project supported by National Natural Science Foundation of China(51277117), Shang- hai Science and Technology Comrmssion(11 DZ2283000).
文摘Cables that have been in service for over 20 years in Shanghai, a city with abundant surface water, failed more frequently and induced different cable accidents. This necessitates researches on the insulation aging state of cables working in special circumstances. We performed multi-parameter tests with samples from about 300 cable lines in Shanghai. The tests included water tree investigation, tensile test, dielectric spectroscopy test, thermogravimetric analysis (TGA), fourier transform infrared spectroscopy (FTIR), and electrical aging test. Then, we carried out regression analysis between every two test parameters. Moreover, through two-sample t-Test and analysis of va- riance (ANOVA) of each test parameter, we analyzed the influences of cable-laying method and sampling section on the degradation of cable insulation respectively. Furthermore, the test parameters which have strong correlation in the regression analysis or significant differ- ences in the t-Test or ANOVA analysis were determined to be the ones identifying the XLPE cable insulation aging state. The thresholds for distinguishing insulation aging states had been also obtained with the aid of statistical analysis and fuzzy clustering. Based on the fuzzy in- ference, we established a cable insulation aging diagnosis model using the intensity transfer method. The results of regression analysis indicate that the degradation of cable insulation accelerates as the degree of in-service aging increases. This validates the rule that the in- crease of microscopic imperfections in solid material enhances the dielectric breakdown strength. The results of the two-sample t-Test and the ANOVA indicate that the direct-buried cables are more sensitive to insulation degradation than duct cables. This confirms that the tensile strength and breakdown strength are reliable functional parameters in cable insulation evaluations. A case study further indicates that the proposed diagnosis model based on the fuzzy inference can reflect the comprehensive aging state of cable insulation well, and that the cable service time has no correlation with the insulation aging state.
基金Supported by the National Natural Science Foundation of China (59677018)
文摘This paper deals with the experimental study on the correlation betweeninsulation resistance (R) and direct current (DC) component (i_(de)) and corresponding aging degreeof insulation in the course of the aging within cross linked polyethylene (XLPE) insulation. Theaging tests were performed on a section of 10 kV transmission XLPE cable by means of water needlemethod, and _R was measured by DC voltage superimposed method, R and i_(de) were found to besignificantly dependent on the correspondingaging degree of insulation in the course of aging ofXLPE, and different kind of aging stage has different characteristics. Beside, there are generallysimilar regularity but different amplitude in the course of aging of XLPE insulation in differentelectrolyte, and the various electrochemical tree were found on the surface of aging XLPE cableimmersed in CuSO_4, solution. Therefore, according to the changing regularity of the DCcharacteristic parameters i. e. R and i_(de) within XLPE insulation judging the aging degree of XLPEinsulation will be an effective method.
基金Supported by the National Key Technologies Research and Development Program of China During the 11th Five-Year Plan Period(No.2007BAE19B01)the Industrial Research Projects of the Science and Technology Plan of Ningbo City,China (No.2007B10033)
文摘Two commercial crosslinkable polyethylene insulation cable granules, designed for 110 and 35 kV voltage insulation, with similar crosslinking temperature but different melting temperature, were chosen as experimental samples for examining their linear dynamic responses during cross-linking. It has been found that the gel contents of cable compounds for 110 and 35 kV insulation are almost the same after they have been cross-linked at the same temperature, pressure and time. And the sample melts show the similar dependence of the dynamic storage modulus, G; on strain. On the other hand, the dynamic temperature ramp test and the dynamic time sweep test indicate that the samples exhibit different dynamic viscoelastic responses during their crosslinking. An expression for describing their erosslinking process was proposed via probing rheokinetics of crosslinking for the two samples.