超极化气体氙-129的低场NMR测量 被引量:5
1
作者 赵修超 孙献平 +3 位作者 袁亚平 石磊 叶朝辉 周欣 《波谱学杂志》 CAS CSCD 北大核心 2016年第3期458-467,共10页
在自旋交换光泵过程中,多种参数可能会影响到最终可获得的超极化气体氙-129核自旋极化度.通过低场(0.002 T)核磁共振(NMR)系统研究了连续流动工作模式的自旋交换光泵过程,当混合工作气体流量为0.3 SLPM和0.5 SLPM时,实验测量得到最佳光... 在自旋交换光泵过程中,多种参数可能会影响到最终可获得的超极化气体氙-129核自旋极化度.通过低场(0.002 T)核磁共振(NMR)系统研究了连续流动工作模式的自旋交换光泵过程,当混合工作气体流量为0.3 SLPM和0.5 SLPM时,实验测量得到最佳光泵泡工作温度;对于同位素富集和自然丰度的氙-129气体,核自旋极化度的建立时间分别为15 min和22 min.由于混合工作气体的压力以及组分会导致铷原子吸收线的频移和展宽,并且影响到其线型,实验通过低场NMR系统测量确定了用于自旋交换光泵的最佳激光工作波长.低场NMR测量为获得具有高核自旋极化度的超极化气体氙-129,并且能够用于人体肺部MRI研究提供了实验依据. 展开更多
关键词 低场核磁共振 超极化气体氙-129 自旋交换光泵
下载PDF
Design and development of a new dedicated RF sensor for the MRI of rat brain
2
作者 Aktham Asfour 《Journal of Biomedical Science and Engineering》 2010年第2期167-180,共14页
The design and development of a new dual-frequency RF probe-head are presented. This probe was initially dedicated for the MRI of both proton (1H) and hyperpolarized Xenon-129 (HP 129Xe) in the rat brain at 2.35 Tesla... The design and development of a new dual-frequency RF probe-head are presented. This probe was initially dedicated for the MRI of both proton (1H) and hyperpolarized Xenon-129 (HP 129Xe) in the rat brain at 2.35 Tesla. It consists of a double-tuned (100 MHz- 27.7 MHz) volume coil, which could be used for both transmitting and receiving, and of a receive-only single-tuned (27.7 MHz) coil. The double-tuned coil consists of two concentric birdcage resonators. The inner one is a low-pass design and it is tuned to 27.7 MHz, while the outer one, tuned to 100 MHz, is high-pass. The receive-only coil is a surface coil which is decoupled from the double-tuned volume coil by an active decoupling circuitry based on the use of PIN diodes. A home-built Transmit/Receive (T/R) driver ensures biasing of the PIN diodes in both volume and surface coils. The original concepts of the design are addressed, and practical details of realization are presented. One of the underlying ideas behind this work is to proceed well beyond the application to the MRI of HP 129Xe. Actually, this design could be easily adapted for a large palette of other MRI applications. Indeed, we tried to make the design versatile, simple and easy to replicate by other research groups, with a low-cost, minimum development time and accepted performances. The prototype was validated at 100 MHz and at 26.4 MHz (sodium-23 resonance frequency at 2.35 T). MRI experiments were performed using phantoms. In vivo 1H images and 23Na spectra of the rat brain are also presented. 展开更多
关键词 MRI RF Coils Double-Tune Active DECOUPLING Proton Sodium-23 Hyperpolarized xenon-129
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部