A 67-year-old man had a sev-ere cough and pulmonary infection for 1 wk before seeking evaluation at our hospital.He had undergone esophagectomy with gastric pull-up and radiotherapy for esophageal cancer 3 years previ...A 67-year-old man had a sev-ere cough and pulmonary infection for 1 wk before seeking evaluation at our hospital.He had undergone esophagectomy with gastric pull-up and radiotherapy for esophageal cancer 3 years previously.After admission to our hospital,gastroscopy and bronchoscopy revealed a fistulous communication between the posterior tracheal wallnear the carina and the upper residual stomach.We measured the diameter of the trachea and bronchus and determined the site and size of the fistula using multislice computed tomography and gastroscopy.A covered self-expanding Y-shaped metallic stent was implanted into the trachea and bronchus.Subsequently,the fistula was closed completely.The patient tolerated the stent well and had good palliation of his symptoms.展开更多
BACKGROUND With the development of percutaneous coronary intervention(PCI),the number of interventional procedures without implantation,such as bioresorbable stents(BRS)and drug-coated balloons,has increased annually....BACKGROUND With the development of percutaneous coronary intervention(PCI),the number of interventional procedures without implantation,such as bioresorbable stents(BRS)and drug-coated balloons,has increased annually.Metal drug-eluting stent unloading is one of the most common clinical complications.Comparatively,BRS detachment is more concealed and harmful,but has yet to be reported in clinical research.In this study,we report a case of BRS unloading and successful rescue.This is a case of a 59-year-old male with the following medical history:“Type 2 diabetes mellitus”for 2 years,maintained with metformin extended-release tablets,1 g PO BID;“hypertension”for 20 years,with long-term use of metoprolol sustained-release tablets,47.5 mg PO QD;“hyperlipidemia”for 20 years,without regular medication.He was admitted to the emergency department of our hospital due to intermittent chest pain lasting 18 hours,on February 20,2022 at 15:35.Electrocardiogram results showed sinus rhythm,ST-segment elevation in leads I and avL,and poor R-wave progression in leads V1–3.High-sensitivity troponin I level was 4.59 ng/mL,indicating an acute high lateral wall myocardial infarction.The patient’s family requested treatment with BRS,without implanta-tion.During PCI,the BRS became unloaded but was successfully rescued.The patient was followed up for 2 years;he had no episodes of angina pectoris and was in generally good condition.CONCLUSION We describe a case of a 59-year-old male experienced BRS unloading and successful rescue.By analyzing images,the causes of BRS unloading and the treatment plan are discussed to provide insights for BRS release operations.We discuss preventive measures for BRS unloading.展开更多
BACKGROUND Endoscopic ultrasound-guided biliary drainage using electrocautery-enhanced(ECE)delivery of lumen-apposing metal stent(LAMS)is gradually being re-cognized as a viable palliative technique for malignant bili...BACKGROUND Endoscopic ultrasound-guided biliary drainage using electrocautery-enhanced(ECE)delivery of lumen-apposing metal stent(LAMS)is gradually being re-cognized as a viable palliative technique for malignant biliary obstruction after endoscopic retrograde cholangiopancreatography(ERCP)failure.However,most of the studies that have assessed its efficacy and safety were small and hetero-geneous.Prior meta-analyses of six or fewer studies that were published 2 years ago were therefore underpowered to yield convincing evidence.AIM To update the efficacy and safety of ECE-LAMS for treatment of biliary ob-struction after ERCP failure.METHODS We searched PubMed,EMBASE,and Scopus databases from the inception of the ECE technique to May 13,2022.Primary outcome measure was pooled technical success rate,and secondary outcomes were pooled rates of clinical success,re-intervention,and adverse events.Meta-analysis was performed using a random-effects model following Freeman-Tukey double-arcsine transformation in R soft-ware(version 4.1.3).RESULTS Fourteen eligible studies involving 620 participants were ultimately included.The pooled rate of technical success was 96.7%,and clinical success was 91.0%.Adverse events were reported in 17.5%of patients.Overall reinter-vention rate was 7.3%.Subgroup analyses showed results were generally consistent.CONCLUSION ECE-LAMS has favorable success with acceptable adverse events in relieving biliary obstruction when ERCP is impossible.The consistency of results across most subgroups suggested that this is a generalizable approach.展开更多
Objective:Double-J(DJ)ureteric stents are commonly placed perioperatively for semirigid or flexible ureteroscopic renal surgery.It is believed that lesser stent material within the bladder mitigates stent-related symp...Objective:Double-J(DJ)ureteric stents are commonly placed perioperatively for semirigid or flexible ureteroscopic renal surgery.It is believed that lesser stent material within the bladder mitigates stent-related symptoms.This study aimed to evaluate the J-Fil ureteral stent,a single pigtail suture stent compared with conventional DJ stent in relation to stent symptoms in an Asian population undergoing ureterorenal intervention.Methods:Based on internal audit committee recommendation approval,the records of 50 patients retrieved,available data of 41 patients who were prospectively enrolled into two groups(Group 1[J-Fil stent group],n=21 and Group 2[DJ stent group],n=20)between August 2020 to January 2021,were analysed.Parameters compared were nature of procedure,stone location and size,ease of deployment or removal,and complications.A modified universal stent symptom questionnaire was used to assess morbidity of stent symptoms within 48 h of insertion and at removal.Results:Both groups had similar median age,distribution in male to female ratio,and stone size.The overall median universal stent symptom questionnaire score at insertion was similar for bladder pain,flank or loin pain,and quality of life between Group 1 and 2;however,at removal Group 1 fared significantly better than Group 2,especially for flank or loin pain and pain at voiding.Both groups had similar ease in insertion with no hospital readmissions.Conclusion:Our audit favoured the single pigtail suture stent in Asian ureters in mitigating stent-related issues.It showed a good safety profile with easy deployment and removal.It promises a new standard in stenting.展开更多
Objective: To examine factors to predict the optimal stent pusher position when inserting ureteral stents under fluoroscopy.Methods: We retrospectively reviewed 327 patients who underwent ureteral stent insertion. We ...Objective: To examine factors to predict the optimal stent pusher position when inserting ureteral stents under fluoroscopy.Methods: We retrospectively reviewed 327 patients who underwent ureteral stent insertion. We considered the pubic bone as a useful anatomical landmark to insert ureteral stents under fluoroscopic guidance. Thus, we categorized patients into three groups (proximal, middle, and distal groups) according to the position of the radiopaque tip of the push catheter when inserting the ureteral stent. Success was defined as a completely curled ureteral stent tail. We compared stent insertion success rates among the three groups. A multivariate analysis was performed to identify the factors affecting stent insertion success.Results: In men, 36 (63.2%) cases were deemed successful in the proximal group compared with 40 (80.0%) cases in the middle group and 12 (20.7%) cases in the distal group (p<0.001). In women, 26 (45.6%) cases were deemed successful in the proximal group compared with 54 (98.2%) cases in the middle group and 38 (76.0%) cases in the distal group (p<0.001). With the multivariate analysis, the stent pusher position was the most significant factor influencing successful stent insertion (men: odds ratio 6.00, 95% confidence interval 2.66-13.51, p<0.001;women: odds ratio 37.80, 95% confidence interval 4.94-289.22, p<0.001).Conclusion: The position of the stent pusher affects stent insertion success. The middle of the pubic symphysis is the optimal position for the radiopaque tip of the pusher when inserting ureteral stents under fluoroscopic guidance.展开更多
Background: Bifurcation lesions pose a high risk for adverse events after percutaneous coronary intervention (PCI). Evidence supporting the benefits of the two-stent strategy (2SS) for treating coronary bifurcation le...Background: Bifurcation lesions pose a high risk for adverse events after percutaneous coronary intervention (PCI). Evidence supporting the benefits of the two-stent strategy (2SS) for treating coronary bifurcation lesions in India is limited. This study aimed to evaluate the clinical outcomes of various 2SSs for percutaneous transluminal coronary angioplasty for bifurcation lesions in India. Materials and Methods: This retrospective, observational, multicentric, real-world study included 64 patients over 8 years. Data on demographics, medical history, PCI procedures, and outcomes were recorded. Descriptive statistics were computed using the SPSS software. Results: Patients (n = 64) had an average age of 65.3 ± 11.1 years, with 78.1% males. Acute coronary syndrome was reported in 18.8%, chronic stable angina in 40.6%, and unstable angina in 34.4% of participants. Two-vessel disease was observed in 98.4% of patients, and 99.4% had true bifurcation lesions. The commonly involved vessels were the left anterior descending artery (50%), left circumflex coronary artery (34.4%), and first diagonal artery (43.8%). Mean percent diameter stenosis was 87.2% ± 10.1%. The mean number of stents used was 2.00 ± 0.34. The 2SS techniques included the T and small protrusion (TAP) (39.1%), double kissing (DK) crush (18.8%), and the culotte techniques (14.1%). Procedural and angiographic success rate was 92.18%. Major adverse cardiovascular events at 1-year follow-up occurred in 7.8% of cases. Conclusion: The 2SS for bifurcation lesions showed favorable in-hospital and follow-up outcomes. Findings can serve as a resource for bifurcation angioplasty in India. Larger real-world studies with robust methodology are needed to validate these results.展开更多
Objective:Ureteral stents are customarily inserted to facilitate urinary drainage,but they come with their own glitches of being forgotten and/or encrusted leading to serious consequences.The present study aimed to re...Objective:Ureteral stents are customarily inserted to facilitate urinary drainage,but they come with their own glitches of being forgotten and/or encrusted leading to serious consequences.The present study aimed to report the complications in patients with forgotten and encrusted stents according to the Clavien-Dindo system specific to urological procedures and identify the factors leading to high-grade(Clavien-Dindo Grade 4A or above)complications.Methods:The hospital records of patients with forgotten encrusted double-J stents over a period of 8 years were reviewed.The parameters recorded included patient demographics,indwelling time,need for percutaneous nephrostomy,hemodialysis,urine culture,blood culture,total blood counts,serum creatinine,radiologic findings,management techniques,number of surgical interventions,modified Clavien-Dindo complications,follow-up,and mortality,if any.Results:Forty patients were included in the study.The median age was 52(range 6-85)years.Of the total,25(62.5%)patients had a“significant”stent load;31(77.5%)had renal failure or acute kidney injury on presentation;19(47.5%)patients had sepsis at presentation.Among the patients presented with sepsis,11(57.9%)patients demonstrated a positive urine culture;and 7/11(63.6%)patients exhibited pan-resistant organisms.Twelve out of 40(30.0%)patients in our series developed high-grade Clavien-Dindo complications.On univariate analysis,sepsis at presentation(p=0.007),stent load(p=0.031),diabetes(p=0.023),positive urine culture(p=0.007),and stent indwelling time of more than 1 year(p=0.031)were found to be significant.On multivariate logistic regression analysis,sepsis at presentation(p=0.017)and positive urine culture(p=0.016)were significant predictors for high-grade complications.Conclusion:It is prudent to identify specific risk factors,namely sepsis at presentation and positive urine culture to triage and optimize these patients before surgical management.展开更多
Patients with malignant biliary obstruction,following endoscopic retrograde cholangiopancreatography(ERCP)failure could be referred for endoscopicultrasound-guided biliary drainage through electrocautery-enhanced(ECE)...Patients with malignant biliary obstruction,following endoscopic retrograde cholangiopancreatography(ERCP)failure could be referred for endoscopicultrasound-guided biliary drainage through electrocautery-enhanced(ECE)lumen-apposing metal stent(LAMS)placement.However,the efficacy and safety of ECE-LAMS in this scenario have remained debatable due to minimal scientific evidence.The current confirmed 91.0%clinical success,96.7%technical success,7.3%reintervention rate,and 17.5%adverse events,following the treatment of malignant biliary obstruction with ECE-LAMS delivery.Finally,ECE-LAMS proved to be a generalizable strategy for managing biliary obstruction for patients who were excluded from ERCP.展开更多
BACKGROUND Esophageal stricture is one of the complications after esophageal varices sclero-therapy injection(ESI),and the incidence rate is between 2%-10%.AIM To explore the efficacy of self-expanding metal stent(SEM...BACKGROUND Esophageal stricture is one of the complications after esophageal varices sclero-therapy injection(ESI),and the incidence rate is between 2%-10%.AIM To explore the efficacy of self-expanding metal stent(SEMS)for the stricture after endoscopic injection with cyanoacrylate(CYA)and sclerotherapy for esophageal varices.METHODS We retrospectively analyzed the efficacy of SEMS to improve the stricture after endoscopic injection with CYA and sclerotherapy for esophageal varices in 4 patients from February 2023 to June 2023.RESULTS The strictures were improved in four patients after stenting.The stent was removed after two weeks because of chest pain with embedding into esophageal mucosa in one patient.The stent was removed after one month,however,the stent was reinserted because of the strictures happening again in two patients.The stent was removed after three months,however,the stent was reinserted because of the strictures happening again in one patient.The stent embedded into esophageal mucosa in three patients.There were 3 patients suffered reflux esophagitis,and the acid reflux was relieved by taking hydrotalcite.There was no other complication of esophageal perforation,bleeding from varices or infection.CONCLUSION SEMS may relieve the stricture which happened after endoscopic injection with CYA and sclerotherapy for esophageal varices.However,when we should remove the stent still needs to be explored.展开更多
BACKGROUND Postoperative abdominal infections are an important and heterogeneous health challenge.Many samll abdominal abscesses are resolved with antibiotics,but larger or symptomatic abscesses may require procedural...BACKGROUND Postoperative abdominal infections are an important and heterogeneous health challenge.Many samll abdominal abscesses are resolved with antibiotics,but larger or symptomatic abscesses may require procedural management.CASE SUMMARY A 65-year-old male patient who suffered operation for the left hepatocellular carcinoma eight months ago,came to our hospital with recurrent abdominal pain,vomit,and fever for one month.Abdominal computed tomography showed that a big low-density dumbbell-shaped mass among the liver and intestine.Colonoscopy showed a submucosal mass with a fistula at colon of liver region.Gastroscopy showed a big rupture on the submucosal mass at the descending duodenum and a fistula at the duodenal bulb.Under colonoscopy,the brown liquid and pus were drained from the mass with“special stent device”.Under gastroscopy,we closed the rupture of the mass with a loop and six clips for purse stitching at the descending duodenum,and the same method as colonoscopy was used to drain the brown liquid and pus from the mass.The symptom of abdominal pain,vomit and fever were relieved after the treatment.CONCLUSION The special stent device could be effectively for draining the abdominal abscess respectively from colon and duodenum.展开更多
Objective: To assess if there is a preferable intervention between retrograde ureteral stent (RUS) and percutaneous nephrostomy (PCN) tube, in cases of upper urinary tract stone obstruction with complications requirin...Objective: To assess if there is a preferable intervention between retrograde ureteral stent (RUS) and percutaneous nephrostomy (PCN) tube, in cases of upper urinary tract stone obstruction with complications requiring urgent drainage, by evaluating outcomes regarding urinary symptoms, quality of life (QoL), spontaneous stone passage, and length of hospital stays, since there is no literature stating the superiority of one modality over the other.Methods: We searched MEDLINE and other sources for relevant articles in June 2019 without any date restrictions or filters applied. The selection was done first by the title and abstract screening and then by full-text assessment for eligibility. Only randomized controlled trials or cohort studies in patients with hydronephrosis secondary to obstructive urolithiasis that presented comparative data between PCN and RUS placement concerning at least one of the defined outcome measures were included. Lastly, MEDLINE database and PubMed platform were screened again using the same terms, from June 2019 until November 2022.Results: Of 556 initial articles, seven were included in this review. Most works were considered of moderate-to-high quality. Three studies regarding QoL showed a tendency against stenting, even though only one demonstrated statistically significant negative impact on overall health state. Two works reported significantly more post-intervention urinary symptoms in stenting patients. One article found that PCN is a significant predictor of spontaneous stone passage, when adjusted for stone size and location. Findings on length of hospital stays were not consistent among articles.Conclusion: PCN appears to be the intervention better tolerated, with less impact on the patient’s perceived QoL and less post-operative urinary symptoms, in comparison with RUS. Nevertheless, further studies with larger samples and a randomized controlled design are suggested.展开更多
Vertebral artery dissection is a rare pathology that can cause ischemic stroke in young people.Cervical massage,especially improper pulling manipulation,is a cause of vertebral artery dissection.We present a case of 3...Vertebral artery dissection is a rare pathology that can cause ischemic stroke in young people.Cervical massage,especially improper pulling manipulation,is a cause of vertebral artery dissection.We present a case of 32-year old woman who developed acute multiple posterior circulation ischemic cerebral infarctions as a result of left vertebral artery V4 segment dissection after receiving neck massage.She underwent emergency vertebral artery stent implantation at the site of the dissection.Symptoms were relieved the day after treatment.The patient recovered without adverse complications or endovascular restenosis in the following year.展开更多
In this letter,we comment on a recent case report by Sun et al in the World Journal of Cardiology.The report describes the successful management of a rare complication:The unloading or detachment of a bioresorbable st...In this letter,we comment on a recent case report by Sun et al in the World Journal of Cardiology.The report describes the successful management of a rare complication:The unloading or detachment of a bioresorbable stent(BRS)during percutaneous coronary intervention(PCI)in a male patient.The unloading of BRS was detected via angiography and intravascular ultrasound(IVUS)imaging of the left coronary artery and left anterior descending artery.Although this case is interesting,the authors’report lacked crucial details.Specifically,insufficient information about the type of BRS used,potential causes of BRS unloading,or whether optical coherence tomography(OCT)imaging for coronary arteries was performed before,during,or after PCI.The OCT imaging of coronary arteries before PCI can potentially prevent BRS unloading due to its higher resolution compared to IVUS.In addition,despite detecting myocardial bridging during the PCI,the authors did not provide any details regarding this variation.Here we discuss the various types of BRS,the importance of OCT in PCI,and the clinical relevance of myocardial bridging.展开更多
The role of endoscopy in pathologies of the bile duct and gallbladder has seen notable advancements over the past two decades.With advancements in stent technology,such as the development of lumen-apposing metal stent...The role of endoscopy in pathologies of the bile duct and gallbladder has seen notable advancements over the past two decades.With advancements in stent technology,such as the development of lumen-apposing metal stents,and adoption of endoscopic ultrasound and electrosurgical principles in therapeutic endoscopy,what was once considered endoscopic failure has transformed into failure of an approach that could be salvaged by a second-or third-line endoscopic strategy.Incorporation of these advancements in routine patient care will require formal training and multidisciplinary acceptance of established techniques and collaboration for advancement of experimental techniques to generate robust evidence that can be utilized to serve patients to the best of our ability.展开更多
BACKGROUND In severe cases of coronary artery disease,percutaneous coronary intervention provide promising results.The stent used could be a drug-eluting stent(DES)or a titanium-nitride-oxide coated stent(TiNOS).AIM T...BACKGROUND In severe cases of coronary artery disease,percutaneous coronary intervention provide promising results.The stent used could be a drug-eluting stent(DES)or a titanium-nitride-oxide coated stent(TiNOS).AIM To compare the 5-year effectiveness and safety of the two stent types.METHODS The following systematic review and meta-analysis was conducted in accordance with the preferred reporting items for systematic reviews and meta-analysis guidelines,and PubMed/MEDLINE,Scopus,and Cochrane Central were searched from inception till August 2023.Primary outcomes were major adverse cardiac events(MACE),cardiac death,myocardial infarction(MI),cardiac death or MI,and ischemia-driven total lesion revascularization(ID-TLR).RESULTS Four randomized controlled trials(RCT),which analyzed a sum total of 3045 patients with acute coronary syndrome(ACS)after a median follow-up time of 5 years were included.Though statistically insignificant,an increase in the ID-TLR was observed in patients receiving TiNOSs vs DESs.In addition,MI,cardiac death and MI,and definite stent thrombosis(DST)were significantly decreased in the TiNOS arm.Baseline analysis revealed no significant results with meta-regression presenting non-ST elevated MI(NSTEMI)as a statistically significant covariate in the outcome of MACE.CONCLUSION TiNOS was found to be superior to DES in terms of MI,cardiac death or MI,and DST outcomes,however,the effect of the two stent types on ID-TLR and MACE was not significant.A greater number of studies are required to establish an accurate comparison of patient outcomes in TiNOS and DES.展开更多
BACKGROUND The stent embedded in the esophageal mucosa is one of the complications after stenting for esophageal stricture.We present a case of stent adjustment with the aid of a transparent cap after endoscopic injec...BACKGROUND The stent embedded in the esophageal mucosa is one of the complications after stenting for esophageal stricture.We present a case of stent adjustment with the aid of a transparent cap after endoscopic injection of an esophageal varices stent.CASE SUMMARY A 61-year-old male patient came to the hospital with discomfort of the chest after the stent implanted for the stenosis because of endoscopic injection of esophageal varices.The gastroscopy was performed,and the stent embedded into the esophageal mucosa.At first,we pulled the recycling line for shrinking the stent,however,the mucosa could not be removed from the stent.Then a forceps was performed to remove the mucosa in the stent,nevertheless,the bleeding form the mucosa was obvious.And then,we used a transparent cap to scrape the mucosa along the stent,and the mucosa were removed successfully without bleeding.CONCLUSION A transparent cap helps gastroscopy to remove the mucosa embedded in the stent after endoscopic injection of the esophageal varices stent.展开更多
Esophageal disease is a common disorder of the digestive system that can severely affect the quality of life andprognosis of patients. Esophageal stenting is an effective treatment that has been widely used in clinica...Esophageal disease is a common disorder of the digestive system that can severely affect the quality of life andprognosis of patients. Esophageal stenting is an effective treatment that has been widely used in clinical practice.However, esophageal stents of different types and parameters have varying adaptability and effectiveness forpatients, and they need to be individually selected according to the patient’s specific situation. The purposeof this study was to provide a reference for clinical doctors to choose suitable esophageal stents. We used 3Dprinting technology to fabricate esophageal stents with different ratios of thermoplastic polyurethane (TPU)/(Poly-ε-caprolactone) PCL polymer, and established an artificial neural network model that could predict the radial forceof esophageal stents based on the content of TPU, PCL and print parameter. We selected three optimal ratios formechanical performance tests and evaluated the biomechanical effects of different ratios of stents on esophagealimplantation, swallowing, and stent migration processes through finite element numerical simulation and in vitrosimulation tests. The results showed that different ratios of polymer stents had different mechanical properties,affecting the effectiveness of stent expansion treatment and the possibility of postoperative complications of stentimplantation.展开更多
Objective:Patients with ductal-dependent pulmonary circulation require alternative bloodflow to provide and maintain adequate oxygenation.Modified Blalock-Taussig Shunt(MBTS)has been the standard for providing such a ...Objective:Patients with ductal-dependent pulmonary circulation require alternative bloodflow to provide and maintain adequate oxygenation.Modified Blalock-Taussig Shunt(MBTS)has been the standard for providing such a result.Currently,less invasive methods such as Arterial Duct(AD)stenting have been performed as alter-natives.This study aims to compare the outcome of AD stenting and MBTS.Method:Systematic research was performed in online databases using the PRISMA protocol.The outcomes measured were 30-day mortality,com-plication,unplanned intervention,oxygen saturation,duration of hospital,and ICU length of stay.Any compara-tive study provided with full text is included.The outcome of each study was analyzed using a trandom effects model with relative risk and mean difference as the effect size.Bias risk assessment was conducted using the New-castle-Ottawa Scale.All analyses were performed using Review Manager 5.4.1.Result:A total of 11 studies with 3154 samples included in this study.There is no significant difference in 30-day mortality between the two groups(p-value=0.10).However,there is significantly less complication(RR 0.53[0.35,0.82];p-value=0.004)and unplanned intervention(RR 0.59[0.38,0.92];p-value=0.02)in the AD stent group.Comparison of the Nakata index showed no significant difference(p-value=0.88).Post-operative oxygen saturation was measured signifi-cantly higher in the AD stenting(MD 1.80[0.85,2.74];p-value=0.0002).However,AD stent group shows sig-nificantly lower long-term oxygen saturation(MD-8.43[-14.38,-2.48];p-value=0.005).Both hospital and ICU length of stay was significantly shorter in the AD stent group(MD-8.30[-11.13,-5.48];p-value<0.00001;MD-5.09[-7.79,-2.38];p-value=0.0002).Conclusion:AD stenting provides comparable outcomes relative to MBTS as it provides less complication and unplanned intervention and higher post-procedural O2 saturation.However,MBTS proved its superiority in maintaining higher long-term oxygen saturation and still became the preferred option to manage complex cases where stenting is either challenging or unsuccessful.展开更多
文摘A 67-year-old man had a sev-ere cough and pulmonary infection for 1 wk before seeking evaluation at our hospital.He had undergone esophagectomy with gastric pull-up and radiotherapy for esophageal cancer 3 years previously.After admission to our hospital,gastroscopy and bronchoscopy revealed a fistulous communication between the posterior tracheal wallnear the carina and the upper residual stomach.We measured the diameter of the trachea and bronchus and determined the site and size of the fistula using multislice computed tomography and gastroscopy.A covered self-expanding Y-shaped metallic stent was implanted into the trachea and bronchus.Subsequently,the fistula was closed completely.The patient tolerated the stent well and had good palliation of his symptoms.
基金Supported by Health Commission of Hunan Province,No.202203014389Chinese Medicine Research Project of Hunan Province,No.A2023051the Natural Science Foundation of Hunan Province,No.2024JJ9414.
文摘BACKGROUND With the development of percutaneous coronary intervention(PCI),the number of interventional procedures without implantation,such as bioresorbable stents(BRS)and drug-coated balloons,has increased annually.Metal drug-eluting stent unloading is one of the most common clinical complications.Comparatively,BRS detachment is more concealed and harmful,but has yet to be reported in clinical research.In this study,we report a case of BRS unloading and successful rescue.This is a case of a 59-year-old male with the following medical history:“Type 2 diabetes mellitus”for 2 years,maintained with metformin extended-release tablets,1 g PO BID;“hypertension”for 20 years,with long-term use of metoprolol sustained-release tablets,47.5 mg PO QD;“hyperlipidemia”for 20 years,without regular medication.He was admitted to the emergency department of our hospital due to intermittent chest pain lasting 18 hours,on February 20,2022 at 15:35.Electrocardiogram results showed sinus rhythm,ST-segment elevation in leads I and avL,and poor R-wave progression in leads V1–3.High-sensitivity troponin I level was 4.59 ng/mL,indicating an acute high lateral wall myocardial infarction.The patient’s family requested treatment with BRS,without implanta-tion.During PCI,the BRS became unloaded but was successfully rescued.The patient was followed up for 2 years;he had no episodes of angina pectoris and was in generally good condition.CONCLUSION We describe a case of a 59-year-old male experienced BRS unloading and successful rescue.By analyzing images,the causes of BRS unloading and the treatment plan are discussed to provide insights for BRS release operations.We discuss preventive measures for BRS unloading.
基金The authors have read the PRISMA 2009 Checklist,and the manuscript was prepared and revised according to the PRISMA 2009 Checklist.
文摘BACKGROUND Endoscopic ultrasound-guided biliary drainage using electrocautery-enhanced(ECE)delivery of lumen-apposing metal stent(LAMS)is gradually being re-cognized as a viable palliative technique for malignant biliary obstruction after endoscopic retrograde cholangiopancreatography(ERCP)failure.However,most of the studies that have assessed its efficacy and safety were small and hetero-geneous.Prior meta-analyses of six or fewer studies that were published 2 years ago were therefore underpowered to yield convincing evidence.AIM To update the efficacy and safety of ECE-LAMS for treatment of biliary ob-struction after ERCP failure.METHODS We searched PubMed,EMBASE,and Scopus databases from the inception of the ECE technique to May 13,2022.Primary outcome measure was pooled technical success rate,and secondary outcomes were pooled rates of clinical success,re-intervention,and adverse events.Meta-analysis was performed using a random-effects model following Freeman-Tukey double-arcsine transformation in R soft-ware(version 4.1.3).RESULTS Fourteen eligible studies involving 620 participants were ultimately included.The pooled rate of technical success was 96.7%,and clinical success was 91.0%.Adverse events were reported in 17.5%of patients.Overall reinter-vention rate was 7.3%.Subgroup analyses showed results were generally consistent.CONCLUSION ECE-LAMS has favorable success with acceptable adverse events in relieving biliary obstruction when ERCP is impossible.The consistency of results across most subgroups suggested that this is a generalizable approach.
文摘Objective:Double-J(DJ)ureteric stents are commonly placed perioperatively for semirigid or flexible ureteroscopic renal surgery.It is believed that lesser stent material within the bladder mitigates stent-related symptoms.This study aimed to evaluate the J-Fil ureteral stent,a single pigtail suture stent compared with conventional DJ stent in relation to stent symptoms in an Asian population undergoing ureterorenal intervention.Methods:Based on internal audit committee recommendation approval,the records of 50 patients retrieved,available data of 41 patients who were prospectively enrolled into two groups(Group 1[J-Fil stent group],n=21 and Group 2[DJ stent group],n=20)between August 2020 to January 2021,were analysed.Parameters compared were nature of procedure,stone location and size,ease of deployment or removal,and complications.A modified universal stent symptom questionnaire was used to assess morbidity of stent symptoms within 48 h of insertion and at removal.Results:Both groups had similar median age,distribution in male to female ratio,and stone size.The overall median universal stent symptom questionnaire score at insertion was similar for bladder pain,flank or loin pain,and quality of life between Group 1 and 2;however,at removal Group 1 fared significantly better than Group 2,especially for flank or loin pain and pain at voiding.Both groups had similar ease in insertion with no hospital readmissions.Conclusion:Our audit favoured the single pigtail suture stent in Asian ureters in mitigating stent-related issues.It showed a good safety profile with easy deployment and removal.It promises a new standard in stenting.
文摘Objective: To examine factors to predict the optimal stent pusher position when inserting ureteral stents under fluoroscopy.Methods: We retrospectively reviewed 327 patients who underwent ureteral stent insertion. We considered the pubic bone as a useful anatomical landmark to insert ureteral stents under fluoroscopic guidance. Thus, we categorized patients into three groups (proximal, middle, and distal groups) according to the position of the radiopaque tip of the push catheter when inserting the ureteral stent. Success was defined as a completely curled ureteral stent tail. We compared stent insertion success rates among the three groups. A multivariate analysis was performed to identify the factors affecting stent insertion success.Results: In men, 36 (63.2%) cases were deemed successful in the proximal group compared with 40 (80.0%) cases in the middle group and 12 (20.7%) cases in the distal group (p<0.001). In women, 26 (45.6%) cases were deemed successful in the proximal group compared with 54 (98.2%) cases in the middle group and 38 (76.0%) cases in the distal group (p<0.001). With the multivariate analysis, the stent pusher position was the most significant factor influencing successful stent insertion (men: odds ratio 6.00, 95% confidence interval 2.66-13.51, p<0.001;women: odds ratio 37.80, 95% confidence interval 4.94-289.22, p<0.001).Conclusion: The position of the stent pusher affects stent insertion success. The middle of the pubic symphysis is the optimal position for the radiopaque tip of the pusher when inserting ureteral stents under fluoroscopic guidance.
文摘Background: Bifurcation lesions pose a high risk for adverse events after percutaneous coronary intervention (PCI). Evidence supporting the benefits of the two-stent strategy (2SS) for treating coronary bifurcation lesions in India is limited. This study aimed to evaluate the clinical outcomes of various 2SSs for percutaneous transluminal coronary angioplasty for bifurcation lesions in India. Materials and Methods: This retrospective, observational, multicentric, real-world study included 64 patients over 8 years. Data on demographics, medical history, PCI procedures, and outcomes were recorded. Descriptive statistics were computed using the SPSS software. Results: Patients (n = 64) had an average age of 65.3 ± 11.1 years, with 78.1% males. Acute coronary syndrome was reported in 18.8%, chronic stable angina in 40.6%, and unstable angina in 34.4% of participants. Two-vessel disease was observed in 98.4% of patients, and 99.4% had true bifurcation lesions. The commonly involved vessels were the left anterior descending artery (50%), left circumflex coronary artery (34.4%), and first diagonal artery (43.8%). Mean percent diameter stenosis was 87.2% ± 10.1%. The mean number of stents used was 2.00 ± 0.34. The 2SS techniques included the T and small protrusion (TAP) (39.1%), double kissing (DK) crush (18.8%), and the culotte techniques (14.1%). Procedural and angiographic success rate was 92.18%. Major adverse cardiovascular events at 1-year follow-up occurred in 7.8% of cases. Conclusion: The 2SS for bifurcation lesions showed favorable in-hospital and follow-up outcomes. Findings can serve as a resource for bifurcation angioplasty in India. Larger real-world studies with robust methodology are needed to validate these results.
文摘Objective:Ureteral stents are customarily inserted to facilitate urinary drainage,but they come with their own glitches of being forgotten and/or encrusted leading to serious consequences.The present study aimed to report the complications in patients with forgotten and encrusted stents according to the Clavien-Dindo system specific to urological procedures and identify the factors leading to high-grade(Clavien-Dindo Grade 4A or above)complications.Methods:The hospital records of patients with forgotten encrusted double-J stents over a period of 8 years were reviewed.The parameters recorded included patient demographics,indwelling time,need for percutaneous nephrostomy,hemodialysis,urine culture,blood culture,total blood counts,serum creatinine,radiologic findings,management techniques,number of surgical interventions,modified Clavien-Dindo complications,follow-up,and mortality,if any.Results:Forty patients were included in the study.The median age was 52(range 6-85)years.Of the total,25(62.5%)patients had a“significant”stent load;31(77.5%)had renal failure or acute kidney injury on presentation;19(47.5%)patients had sepsis at presentation.Among the patients presented with sepsis,11(57.9%)patients demonstrated a positive urine culture;and 7/11(63.6%)patients exhibited pan-resistant organisms.Twelve out of 40(30.0%)patients in our series developed high-grade Clavien-Dindo complications.On univariate analysis,sepsis at presentation(p=0.007),stent load(p=0.031),diabetes(p=0.023),positive urine culture(p=0.007),and stent indwelling time of more than 1 year(p=0.031)were found to be significant.On multivariate logistic regression analysis,sepsis at presentation(p=0.017)and positive urine culture(p=0.016)were significant predictors for high-grade complications.Conclusion:It is prudent to identify specific risk factors,namely sepsis at presentation and positive urine culture to triage and optimize these patients before surgical management.
文摘Patients with malignant biliary obstruction,following endoscopic retrograde cholangiopancreatography(ERCP)failure could be referred for endoscopicultrasound-guided biliary drainage through electrocautery-enhanced(ECE)lumen-apposing metal stent(LAMS)placement.However,the efficacy and safety of ECE-LAMS in this scenario have remained debatable due to minimal scientific evidence.The current confirmed 91.0%clinical success,96.7%technical success,7.3%reintervention rate,and 17.5%adverse events,following the treatment of malignant biliary obstruction with ECE-LAMS delivery.Finally,ECE-LAMS proved to be a generalizable strategy for managing biliary obstruction for patients who were excluded from ERCP.
文摘BACKGROUND Esophageal stricture is one of the complications after esophageal varices sclero-therapy injection(ESI),and the incidence rate is between 2%-10%.AIM To explore the efficacy of self-expanding metal stent(SEMS)for the stricture after endoscopic injection with cyanoacrylate(CYA)and sclerotherapy for esophageal varices.METHODS We retrospectively analyzed the efficacy of SEMS to improve the stricture after endoscopic injection with CYA and sclerotherapy for esophageal varices in 4 patients from February 2023 to June 2023.RESULTS The strictures were improved in four patients after stenting.The stent was removed after two weeks because of chest pain with embedding into esophageal mucosa in one patient.The stent was removed after one month,however,the stent was reinserted because of the strictures happening again in two patients.The stent was removed after three months,however,the stent was reinserted because of the strictures happening again in one patient.The stent embedded into esophageal mucosa in three patients.There were 3 patients suffered reflux esophagitis,and the acid reflux was relieved by taking hydrotalcite.There was no other complication of esophageal perforation,bleeding from varices or infection.CONCLUSION SEMS may relieve the stricture which happened after endoscopic injection with CYA and sclerotherapy for esophageal varices.However,when we should remove the stent still needs to be explored.
文摘BACKGROUND Postoperative abdominal infections are an important and heterogeneous health challenge.Many samll abdominal abscesses are resolved with antibiotics,but larger or symptomatic abscesses may require procedural management.CASE SUMMARY A 65-year-old male patient who suffered operation for the left hepatocellular carcinoma eight months ago,came to our hospital with recurrent abdominal pain,vomit,and fever for one month.Abdominal computed tomography showed that a big low-density dumbbell-shaped mass among the liver and intestine.Colonoscopy showed a submucosal mass with a fistula at colon of liver region.Gastroscopy showed a big rupture on the submucosal mass at the descending duodenum and a fistula at the duodenal bulb.Under colonoscopy,the brown liquid and pus were drained from the mass with“special stent device”.Under gastroscopy,we closed the rupture of the mass with a loop and six clips for purse stitching at the descending duodenum,and the same method as colonoscopy was used to drain the brown liquid and pus from the mass.The symptom of abdominal pain,vomit and fever were relieved after the treatment.CONCLUSION The special stent device could be effectively for draining the abdominal abscess respectively from colon and duodenum.
文摘Objective: To assess if there is a preferable intervention between retrograde ureteral stent (RUS) and percutaneous nephrostomy (PCN) tube, in cases of upper urinary tract stone obstruction with complications requiring urgent drainage, by evaluating outcomes regarding urinary symptoms, quality of life (QoL), spontaneous stone passage, and length of hospital stays, since there is no literature stating the superiority of one modality over the other.Methods: We searched MEDLINE and other sources for relevant articles in June 2019 without any date restrictions or filters applied. The selection was done first by the title and abstract screening and then by full-text assessment for eligibility. Only randomized controlled trials or cohort studies in patients with hydronephrosis secondary to obstructive urolithiasis that presented comparative data between PCN and RUS placement concerning at least one of the defined outcome measures were included. Lastly, MEDLINE database and PubMed platform were screened again using the same terms, from June 2019 until November 2022.Results: Of 556 initial articles, seven were included in this review. Most works were considered of moderate-to-high quality. Three studies regarding QoL showed a tendency against stenting, even though only one demonstrated statistically significant negative impact on overall health state. Two works reported significantly more post-intervention urinary symptoms in stenting patients. One article found that PCN is a significant predictor of spontaneous stone passage, when adjusted for stone size and location. Findings on length of hospital stays were not consistent among articles.Conclusion: PCN appears to be the intervention better tolerated, with less impact on the patient’s perceived QoL and less post-operative urinary symptoms, in comparison with RUS. Nevertheless, further studies with larger samples and a randomized controlled design are suggested.
文摘Vertebral artery dissection is a rare pathology that can cause ischemic stroke in young people.Cervical massage,especially improper pulling manipulation,is a cause of vertebral artery dissection.We present a case of 32-year old woman who developed acute multiple posterior circulation ischemic cerebral infarctions as a result of left vertebral artery V4 segment dissection after receiving neck massage.She underwent emergency vertebral artery stent implantation at the site of the dissection.Symptoms were relieved the day after treatment.The patient recovered without adverse complications or endovascular restenosis in the following year.
文摘In this letter,we comment on a recent case report by Sun et al in the World Journal of Cardiology.The report describes the successful management of a rare complication:The unloading or detachment of a bioresorbable stent(BRS)during percutaneous coronary intervention(PCI)in a male patient.The unloading of BRS was detected via angiography and intravascular ultrasound(IVUS)imaging of the left coronary artery and left anterior descending artery.Although this case is interesting,the authors’report lacked crucial details.Specifically,insufficient information about the type of BRS used,potential causes of BRS unloading,or whether optical coherence tomography(OCT)imaging for coronary arteries was performed before,during,or after PCI.The OCT imaging of coronary arteries before PCI can potentially prevent BRS unloading due to its higher resolution compared to IVUS.In addition,despite detecting myocardial bridging during the PCI,the authors did not provide any details regarding this variation.Here we discuss the various types of BRS,the importance of OCT in PCI,and the clinical relevance of myocardial bridging.
文摘The role of endoscopy in pathologies of the bile duct and gallbladder has seen notable advancements over the past two decades.With advancements in stent technology,such as the development of lumen-apposing metal stents,and adoption of endoscopic ultrasound and electrosurgical principles in therapeutic endoscopy,what was once considered endoscopic failure has transformed into failure of an approach that could be salvaged by a second-or third-line endoscopic strategy.Incorporation of these advancements in routine patient care will require formal training and multidisciplinary acceptance of established techniques and collaboration for advancement of experimental techniques to generate robust evidence that can be utilized to serve patients to the best of our ability.
文摘BACKGROUND In severe cases of coronary artery disease,percutaneous coronary intervention provide promising results.The stent used could be a drug-eluting stent(DES)or a titanium-nitride-oxide coated stent(TiNOS).AIM To compare the 5-year effectiveness and safety of the two stent types.METHODS The following systematic review and meta-analysis was conducted in accordance with the preferred reporting items for systematic reviews and meta-analysis guidelines,and PubMed/MEDLINE,Scopus,and Cochrane Central were searched from inception till August 2023.Primary outcomes were major adverse cardiac events(MACE),cardiac death,myocardial infarction(MI),cardiac death or MI,and ischemia-driven total lesion revascularization(ID-TLR).RESULTS Four randomized controlled trials(RCT),which analyzed a sum total of 3045 patients with acute coronary syndrome(ACS)after a median follow-up time of 5 years were included.Though statistically insignificant,an increase in the ID-TLR was observed in patients receiving TiNOSs vs DESs.In addition,MI,cardiac death and MI,and definite stent thrombosis(DST)were significantly decreased in the TiNOS arm.Baseline analysis revealed no significant results with meta-regression presenting non-ST elevated MI(NSTEMI)as a statistically significant covariate in the outcome of MACE.CONCLUSION TiNOS was found to be superior to DES in terms of MI,cardiac death or MI,and DST outcomes,however,the effect of the two stent types on ID-TLR and MACE was not significant.A greater number of studies are required to establish an accurate comparison of patient outcomes in TiNOS and DES.
基金Supported by Hangzhou Agricultural and Social Development Research Guidance Project,No.20220919Y037.
文摘BACKGROUND The stent embedded in the esophageal mucosa is one of the complications after stenting for esophageal stricture.We present a case of stent adjustment with the aid of a transparent cap after endoscopic injection of an esophageal varices stent.CASE SUMMARY A 61-year-old male patient came to the hospital with discomfort of the chest after the stent implanted for the stenosis because of endoscopic injection of esophageal varices.The gastroscopy was performed,and the stent embedded into the esophageal mucosa.At first,we pulled the recycling line for shrinking the stent,however,the mucosa could not be removed from the stent.Then a forceps was performed to remove the mucosa in the stent,nevertheless,the bleeding form the mucosa was obvious.And then,we used a transparent cap to scrape the mucosa along the stent,and the mucosa were removed successfully without bleeding.CONCLUSION A transparent cap helps gastroscopy to remove the mucosa embedded in the stent after endoscopic injection of the esophageal varices stent.
基金Nanning Technology and Innovation Special Program(20204122)and Research Grant for 100 Talents of Guangxi Plan.
文摘Esophageal disease is a common disorder of the digestive system that can severely affect the quality of life andprognosis of patients. Esophageal stenting is an effective treatment that has been widely used in clinical practice.However, esophageal stents of different types and parameters have varying adaptability and effectiveness forpatients, and they need to be individually selected according to the patient’s specific situation. The purposeof this study was to provide a reference for clinical doctors to choose suitable esophageal stents. We used 3Dprinting technology to fabricate esophageal stents with different ratios of thermoplastic polyurethane (TPU)/(Poly-ε-caprolactone) PCL polymer, and established an artificial neural network model that could predict the radial forceof esophageal stents based on the content of TPU, PCL and print parameter. We selected three optimal ratios formechanical performance tests and evaluated the biomechanical effects of different ratios of stents on esophagealimplantation, swallowing, and stent migration processes through finite element numerical simulation and in vitrosimulation tests. The results showed that different ratios of polymer stents had different mechanical properties,affecting the effectiveness of stent expansion treatment and the possibility of postoperative complications of stentimplantation.
文摘Objective:Patients with ductal-dependent pulmonary circulation require alternative bloodflow to provide and maintain adequate oxygenation.Modified Blalock-Taussig Shunt(MBTS)has been the standard for providing such a result.Currently,less invasive methods such as Arterial Duct(AD)stenting have been performed as alter-natives.This study aims to compare the outcome of AD stenting and MBTS.Method:Systematic research was performed in online databases using the PRISMA protocol.The outcomes measured were 30-day mortality,com-plication,unplanned intervention,oxygen saturation,duration of hospital,and ICU length of stay.Any compara-tive study provided with full text is included.The outcome of each study was analyzed using a trandom effects model with relative risk and mean difference as the effect size.Bias risk assessment was conducted using the New-castle-Ottawa Scale.All analyses were performed using Review Manager 5.4.1.Result:A total of 11 studies with 3154 samples included in this study.There is no significant difference in 30-day mortality between the two groups(p-value=0.10).However,there is significantly less complication(RR 0.53[0.35,0.82];p-value=0.004)and unplanned intervention(RR 0.59[0.38,0.92];p-value=0.02)in the AD stent group.Comparison of the Nakata index showed no significant difference(p-value=0.88).Post-operative oxygen saturation was measured signifi-cantly higher in the AD stenting(MD 1.80[0.85,2.74];p-value=0.0002).However,AD stent group shows sig-nificantly lower long-term oxygen saturation(MD-8.43[-14.38,-2.48];p-value=0.005).Both hospital and ICU length of stay was significantly shorter in the AD stent group(MD-8.30[-11.13,-5.48];p-value<0.00001;MD-5.09[-7.79,-2.38];p-value=0.0002).Conclusion:AD stenting provides comparable outcomes relative to MBTS as it provides less complication and unplanned intervention and higher post-procedural O2 saturation.However,MBTS proved its superiority in maintaining higher long-term oxygen saturation and still became the preferred option to manage complex cases where stenting is either challenging or unsuccessful.