在采样系统的分析中,系统的脉冲 Z 传函 G(Z)或者系统输出的 Z 变换Y(Z)的求取是十分重要的工作。本文提出一种“星”运算法,并在此基础上推导证明了适用于采样系统变形的 Mason 公式,利用此公式,可以方便地求取某些采样系统的 Y(Z)或 G...在采样系统的分析中,系统的脉冲 Z 传函 G(Z)或者系统输出的 Z 变换Y(Z)的求取是十分重要的工作。本文提出一种“星”运算法,并在此基础上推导证明了适用于采样系统变形的 Mason 公式,利用此公式,可以方便地求取某些采样系统的 Y(Z)或 GB(Z)。展开更多
A generalized formula for penetrating boundary conditions is derived based on the Z-transform. The well-known absorbing boundary conditions (ABCs), such as the Mur’s ABC, and Liao’s ABC, can be deduced from the form...A generalized formula for penetrating boundary conditions is derived based on the Z-transform. The well-known absorbing boundary conditions (ABCs), such as the Mur’s ABC, and Liao’s ABC, can be deduced from the formula. Furthermore, some new ABCs can also be deduced from it. The stability of these ABCs are demonstrated via Von Neurmann method and their validity is verified by numerical examples.展开更多
In actual air-conditioning systems,accurate calculation of dynamic loads is demandedfor the energy and materials saving and comfort control.At about the beginning of the1970s,researchers abroad developed the harmonic ...In actual air-conditioning systems,accurate calculation of dynamic loads is demandedfor the energy and materials saving and comfort control.At about the beginning of the1970s,researchers abroad developed the harmonic wave method(HWM),thermal responsefactor method(TRFM)and Z-transfer function method(ZTFM),and made greatachievements on the transition of air-conditioning loads calculation from steady methods展开更多
文摘A generalized formula for penetrating boundary conditions is derived based on the Z-transform. The well-known absorbing boundary conditions (ABCs), such as the Mur’s ABC, and Liao’s ABC, can be deduced from the formula. Furthermore, some new ABCs can also be deduced from it. The stability of these ABCs are demonstrated via Von Neurmann method and their validity is verified by numerical examples.
基金Project supported by the National Natural Science Foundation of ChinaDoctor Subject Foundation of China, College Faculty Academic Foundation of Shanghaithe Science and Technology Foundation of Shanghai Jiaotong University.
文摘In actual air-conditioning systems,accurate calculation of dynamic loads is demandedfor the energy and materials saving and comfort control.At about the beginning of the1970s,researchers abroad developed the harmonic wave method(HWM),thermal responsefactor method(TRFM)and Z-transfer function method(ZTFM),and made greatachievements on the transition of air-conditioning loads calculation from steady methods