The advantages of a flat-panel X-ray source(FPXS)make it a promising candidate for imaging applications.Accurate imaging-system modeling and projection simulation are critical for analyzing imaging performance and res...The advantages of a flat-panel X-ray source(FPXS)make it a promising candidate for imaging applications.Accurate imaging-system modeling and projection simulation are critical for analyzing imaging performance and resolving overlapping projection issues in FPXS.The conventional analytical ray-tracing approach is limited by the number of patterns and is not applicable to FPXS-projection calculations.However,the computation time of Monte Carlo(MC)simulation is independent of the size of the patterned arrays in FPXS.This study proposes two high-efficiency MC projection simulators for FPXS:a graphics processing unit(GPU)-based phase-space sampling MC(gPSMC)simulator and GPU-based fluence sampling MC(gFSMC)simulator.The two simulators comprise three components:imaging-system modeling,photon initialization,and physical-interaction simulations in the phantom.Imaging-system modeling was performed by modeling the FPXS,imaging geometry,and detector.The gPSMC simulator samples the initial photons from the phase space,whereas the gFSMC simulator performs photon initialization from the calculated energy spectrum and fluence map.The entire process of photon interaction with the geometry and arrival at the detector was simulated in parallel using multiple GPU kernels,and projections based on the two simulators were calculated.The accuracies of the two simulators were evaluated by comparing them with the conventional analytical ray-tracing approach and acquired projections,and the efficiencies were evaluated by comparing the computation time.The results of simulated and realistic experiments illustrate the accuracy and efficiency of the proposed gPSMC and gFSMC simulators in the projection calculation of various phantoms.展开更多
Distributed X-ray sources comprise a single vacuum chamber containing multiple X-ray sources that are triggered and emit X-rays at a specific time and location. This process facilitates an application for innovative s...Distributed X-ray sources comprise a single vacuum chamber containing multiple X-ray sources that are triggered and emit X-rays at a specific time and location. This process facilitates an application for innovative system concepts in X-ray and computer tomography. This paper proposes a novel electron beam focusing, shaping,and deflection electron gun for distributed X-ray sources.The electron gun uses a dispenser cathode as an electron emitter, a mesh grid to control emission current, and two electrostatic lenses for beam shaping, focusing, and deflection. Novel focusing and deflecting electrodes were designed to increase the number of focal spots in the distributed source. Two identical half-rectangle opening electrodes are controlled by adjusting the potential of the two electrodes to control the electron beam trajectory, and then, multifocal spots are obtained on the anode target. The electron gun can increase the spatial density of the distributed X-ray sources, thereby improving the image quality. The beam experimental results show that the focal spot sizes of the deflected(deflected amplitude 10.5 mm)and non-deflected electron beams at full width at half maximum are 0.80 mm 90.50 mm and 0.55 mm 90.40 mm, respectively(anode voltage 160 kV; beam current 30 mA). The imaging experimental results demonstrate the excellent spatial resolution and time resolution of an imaging system built with the sources, which has an excellent imaging effect on a field-programmable gate array chip and a rotating metal disk.展开更多
An experiment with thin titanium foils irradiated by two pulses delayed in time is conducted on the bnenguang-Il laser facility. A prepulse induces an underdense plasma, 2-ns later a main pulse (λL ≈ 0.35 μm, EL ...An experiment with thin titanium foils irradiated by two pulses delayed in time is conducted on the bnenguang-Il laser facility. A prepulse induces an underdense plasma, 2-ns later a main pulse (λL ≈ 0.35 μm, EL ≈120 J, τL ≈100 ps) is injected into the underdense plasma and produces strong line emission from the titanium K shell (i.e., Hea at 4.7 keV). Data show that the intensity of 4.7-keV X-ray emission with the prepulse is approximately twice more than without the prepulse, and can be used as a backlighting source satisfying the diagnostic requirements for dense plasma probing. High- quality plasma images are obtained with the backlighfing 4.7-keV X-rays in a Rayleigh-Taylor hydrodynamic instability experiment.展开更多
Although discovered more than 100 years ago, X-ray source technology has evolved rather slowly. The recent invention of the carbon nanotube (CNT) X-ray source technology holds great promise to revolutionize the fiel...Although discovered more than 100 years ago, X-ray source technology has evolved rather slowly. The recent invention of the carbon nanotube (CNT) X-ray source technology holds great promise to revolutionize the field of biomedical X-ray imaging. CNT X-ray sources have been successfully adapted to several biomedical imaging applications including dynamic rnicro-CT of small animals and stationary breast tomosynthesis of breast cancers. Yet their more irnportant biomedical imaging applications still lie ahead in the future, with the devel- oprnent of stationary rnulti-source CT as a noteworthy exarnple.展开更多
A possible novel application of hard x-ray emitted during laser-plasma interaction was discussed. We established an Optical Transform Function to study the joint effect of the spectral distribution and temporal profil...A possible novel application of hard x-ray emitted during laser-plasma interaction was discussed. We established an Optical Transform Function to study the joint effect of the spectral distribution and temporal profile of the laser-produced x-ray on x-ray phase imaging. Though the laser-produced x-ray pulse duration is short and incoherent, the analysis confirms that the current x-ray phase imaging theory still holds for laser-produced x-ray phase imaging.展开更多
X-Ray sources, detectors and optical components are now used in a wide range of applications. What is crucial is the absolute calibration of such devices to permit a quantitative assessment of the system under study. ...X-Ray sources, detectors and optical components are now used in a wide range of applications. What is crucial is the absolute calibration of such devices to permit a quantitative assessment of the system under study. A new X-ray laboratory has been built in Frascati (ENEA) to develop diagnostics for nuclear fusion experiments and study applications of these X-ray techniques in other domains, like new material science, non destructive tests and so on. An in-house developed selfconsistent calibration procedure is described that permits the absolute calibration of sources (X-ray emitted fluxes) and detectors (detection efficiencies) as function of the X-ray photon energy, in the range 2 - 120 keV. The calibration procedure involves the use of an in-house developed code that also predicts the spectral response of any detector in any experimental condition that can be setup in the laboratory. The procedure has been then applied for the calibration and characterisation of gas and solid state imaging detectors, such as Medipix-2, GEM gas detector, CCD camera, Cd-Te C-MOS imager, demonstrating the versatility of the method developed here.展开更多
Z-pinch experiments with two arrays consisting, respectively, of 32 4-μm- and 6-μm-diameter tungsten wires have been carried out on QiangGuang-1 facility with a current rising up to 1.5 MA in 80 ns. At early time of...Z-pinch experiments with two arrays consisting, respectively, of 32 4-μm- and 6-μm-diameter tungsten wires have been carried out on QiangGuang-1 facility with a current rising up to 1.5 MA in 80 ns. At early time of implosion, x-ray framing images show that the initial emission comes from the central part of arrays, and double clear emission rings, drifting to the anode and the cathode at 5×10^6 cm/s and 2.4×10^7 cm/s respectively, are often produced near the electrodes. Later, in a 4-μm-diameter tungsten wire array, filamentation caused by ohmic heating is prominent, and more than ten filaments have been observed. A radial inward shift of arrays starts at about 30 ns earlier than the occurrence of the x-ray peak power for both kinds of arrays, and the shrinkage rate of emission region is as high as 1.7×107 cm/s in a 4-μm-diameter tungsten wire array, which is two times higher than that in a 6-μm one. Emission from precursor plasmas is observed in implosion of 6-μm-diameter tungsten wire arrays, but not in implosion of a 4- μm-diameter tungsten wire array. Whereas, in a 4-μm-diameter tungsten wire array, the soft x-ray emission shows the growth of m=l instability in the plasma column, which is caused by current. The reasons for the discrepancy between implosions of 4-μm- and 6-μm-diameter tungsten wire arrays are explained.展开更多
Two 50-μm Mo wires in parallel used as a Z-pinch load are electrically exploded with a pulsed current rising to 275 kA in 125 ns and their explosion processes are backlighted using an X-pinch as an x-ray source. The ...Two 50-μm Mo wires in parallel used as a Z-pinch load are electrically exploded with a pulsed current rising to 275 kA in 125 ns and their explosion processes are backlighted using an X-pinch as an x-ray source. The backlighting images show clearly the processes similar to those occurring in the initial stages of a cylindrical wire-array Z-pinch, including the electric explosion of single wires characterised by the dense wire cores surrounded by a low-density coronal plasma, the expansion of the exploding wire, the sausage instability (m = 0) in the coronal plasma around each wire, the motion of the coronal plasma as well as the wire core toward the current centroid, the formation of the precursor plasma column with a twist structure something like that of higher mode instability, especially the kink instability (m = 1).展开更多
Mineralogical analysis was performed on bulk sediments of 79 surface samples using X-ray diffraction. The analytical results, combined with data on ocean currents and the regional geological background, were used to i...Mineralogical analysis was performed on bulk sediments of 79 surface samples using X-ray diffraction. The analytical results, combined with data on ocean currents and the regional geological background, were used to investigate the mineral sources. Mineral assemblages in sediments and their distribution in the study area indicate that the material sources are complex. (1) Feldspar is abundant in the sediments of the middle Chukchi Sea near the Bering Strait, originating from sediments in the Anadyr River carried by the Anadyr Current. Sediments deposited on the western side of the Chukchi Sea are rich in feldspar. Compared with other areas, sediments in this region are rich in hornblende transported from volcanic and sedimentary rocks in Siberia by the Anadyr Stream and the Siberian Coastal Current. Sediments in the eastern Chukchi Sea are rich in quartz sourced from sediments of the Yukon and Kuskokwim rivers carried by the Alaska Coastal Current. Sediments in the northern Chukchi Sea are rich in quartz and carbonates from the Mackenzie River sediments. (2) Sediments of the southern and central Canada Basin contain little calcite and dolomite, mainly due to the small impact of the Beaufort Gyre carrying carbonates from the Canadian Arctic Islands. Compared with other areas, the mica content in the region is high, implying that the Laptev Sea is the main sediment source for the southern and central Canada Basin. In the other deep sea areas, calcite and dolomite levels are high caused by the input of large amounts of sediment carried by the Beaufort Gyre from the Canadian Arctic Islands (Banks and Victoria). The Siberian Laptev Sea also provides small amounts of sediment for this region. Furthermore, the Atlantic mid-water contributes some fine-grained material to the entire deep western Arctic Ocean.展开更多
Several experiments are performed on the ShenGuang-Ⅱ laser facility to investigate an x-ray source and test radiography concepts. X-ray lines emitted from laser-produced plasmas are the most practical means of genera...Several experiments are performed on the ShenGuang-Ⅱ laser facility to investigate an x-ray source and test radiography concepts. X-ray lines emitted from laser-produced plasmas are the most practical means of generating these high intensity sources. By using a time-integrated space-resolved keV spectroscope and pinhole camera, potential helium-like titanium Kα x-ray backlighting (radiography) line source is studied as a function of laser wavelength, ratio of pre-pulse intensity to main pulse intensity, and laser intensity (from 7.25 to ~ 11.3 × 10^15 W/cm2). One-dimensional radiography using a grid consisting of 5 #m Au wires on 16 μm period and the pinhole-assisted point projection is tested. The measurements show that the size of the helium-like titanium Ka source from a simple foil target is larger than 100 ~m, and relative x-ray line emission conversion efficiency ~x from the incident laser light energy to helium- like titanium K-shell spectrum increases significantly with pre-pulse intensity increasing, increases rapidly with laser wavelength decreasing, and increases moderately with main laser intensity increasing. It is also found that a gold gird foils can reach an imaging resolution better than 5-μm featured with high contrast. It is further demonstrated that the pinhole-assisted point projection at such a level will be a novel two-dimensional imaging diagnostic technique for inertial confinement fusion experiments.展开更多
In order to acquire a broadband absorption spectrum in a single shot,a compact radiation source was developed by using a Z-pinch type electric discharge.This paper presents the mechanical and electrical construction o...In order to acquire a broadband absorption spectrum in a single shot,a compact radiation source was developed by using a Z-pinch type electric discharge.This paper presents the mechanical and electrical construction of the source,as well as its electrical and optical characteristics,including the intense continuum of radiation emitted by the source in the UV and visible spectral range.It also shows that the compactness of the source allows direct coupling with the probed medium,enabling broadband absorption measurement in the spectral range of 200e300 nm without use of an optical fiber which strongly attenuates the light in the short wavelength range.Concretely,thanks to this source,broadband spectral absorption of NO molecules around 210 nm and that of OH molecules around 310 nm were recorded in this direct coupling arrangement.Copper atom spectral absorption around 325 nm of the peripheral cold zones of an intense transient arc was also recorded.展开更多
A 2856-MHz,π-mode,seven-cell standingwave deflecting cavity was designed and fabricated for bunch length measurement in Tsinghua Thomson scattering X-ray source(TTX)facility.This cavity was installed in the TTX and p...A 2856-MHz,π-mode,seven-cell standingwave deflecting cavity was designed and fabricated for bunch length measurement in Tsinghua Thomson scattering X-ray source(TTX)facility.This cavity was installed in the TTX and provided a deflecting voltage of 4.2 MV with an input power of 2.5 MW.Bunch length diagnoses of electron beams with energies up to 39 MeV have been performed.In this article,the RF design of the cavity using HFSS,fabrication,and RF test processes are reviewed.High-power operation with accelerated beams and calibration of the deflecting voltage are also presented.展开更多
An X-ray radiation source with approximately constant radiation temperature is realized by irradiating golden hohlraum with a shaped laser pulse. A simple theoretical model based on power balance is used to design the...An X-ray radiation source with approximately constant radiation temperature is realized by irradiating golden hohlraum with a shaped laser pulse. A simple theoretical model based on power balance is used to design the shape of the drive laser pulse. Experiments are carried out on the Shenguang III prototype laser facility, and the experimentM results are presented for radiation sources with the flat-top lasting about 2.5 ns at two different peak temperatures of about 150 eV and 170 eV, respectively, including the the drive laser pulses and the time integrated possible improvements are discussed. time histories of the temperatures, the shapes of radiation spectra. The validity of the model and展开更多
Energy spectra, angular distributions, and temporal profiles of the photons produced by an all-optical Thomson scat- tering X-ray source are explored through numerical simulations based on the parameters of the SILEX-...Energy spectra, angular distributions, and temporal profiles of the photons produced by an all-optical Thomson scat- tering X-ray source are explored through numerical simulations based on the parameters of the SILEX-I laser system (800 nm, 30 fs, 300 TW) and the previous wakefield acceleration experimental results. The simulation results show that X-ray pulses with a duration of 30 fs and an emission angle of 50 mrad can be produced from such a source. Using the optimized electron parameters, X-ray pulses with better directivity and narrower energy spectra can be obtained. Besides the electron parameters, the laser parameters such as the wavelength, pulse duration, and spot size also affect the X-ray yield, the angular distribution, and the maximum photon energy, except the X-ray pulse duration which is slightly changed for the case of ultrafast laser-electron interaction.展开更多
Study on X-ray emission from a low energy (1.8 kJ) plasma focus devicepowered by a 9 μF capacitor bank, charged at 20 kV and giving peak discharge current of about 175kA by using a lead-inserted copper-tapered anode ...Study on X-ray emission from a low energy (1.8 kJ) plasma focus devicepowered by a 9 μF capacitor bank, charged at 20 kV and giving peak discharge current of about 175kA by using a lead-inserted copper-tapered anode is reported. The X-ray yield in different energywindows is measured as a function of hydrogen filling pressure. The maximum yield in 4π-geometry isfound to be (27.3+-1.1) J and corresponding wall plug efficiency for X-ray generation is 1.52+-0.06%. X-ray emission, presumably due to bombarding activity of electrons in current sheath at theanode tip was dominant, which is confirmed by the pinhole images. The feasibility of the device asan intense X-ray source for radiography is demonstrated.展开更多
This paper studies the properties of a kind of portable ultra-bright microfocus x-ray source with the Monte-Carlo method in detail. The new x-ray source consists of an electron-emission system, an electrostatic focusi...This paper studies the properties of a kind of portable ultra-bright microfocus x-ray source with the Monte-Carlo method in detail. The new x-ray source consists of an electron-emission system, an electrostatic focusing system and a metal target. A crystal Lanthanum Hexaboride cathode, a Wehnelt grid and an extracted electrode compose the triode electrode electron-gun system. Two equal radius cylinder electrodes form the focusing system. The key factors determining the focus properties of the electron beam such as the ratio Dw/H, grid bias Vg, and the properties of the extracted electrode arc numerically studied. The calculated results reveal that when Dw/H, Vg, the length of the extracted electrode, and the distance between the grid and the extracted electrode equals 5, q).6 kV, 10 mm, and 8 mm respectively, the electron beam focal spot can be concentrated down to 9 μm in radius and a reasonable focal length about 72.5 mm can be achieved, at the same time, the cathode emission currents can be as high as 30 mA.展开更多
X-ray in-line phase contrast imaging enables weakly to absorb specimens to be imaged successfully with high resolution and definition. In this paper we use computer simulation method to analyze how each parameter infl...X-ray in-line phase contrast imaging enables weakly to absorb specimens to be imaged successfully with high resolution and definition. In this paper we use computer simulation method to analyze how each parameter influences the quality of the image. It can avoid wasting unnecessary time and materials in the course of experiment to get ideal images.展开更多
An experiment facility has been set up for the study of metal cluster compounds in our laboratory, which consists of a nano-electrospray ionization source, an ion transmission and focus system, and a reflectron time-o...An experiment facility has been set up for the study of metal cluster compounds in our laboratory, which consists of a nano-electrospray ionization source, an ion transmission and focus system, and a reflectron time-of-fight mass spectrometer. Taking advantage of the nano-electrospray ionization source, polyvalent ions are usually produced in the "ionization" process and the obtained mass resolution of the equipment is over 8000. The molecular ion peaks of metal cluster compounds [Au20(PPhpy2)10Cl2](SbF6)4, where PPhpy2=bis(2- pyridyl)phenylphosphine, and [AuaAg2(C)L6](BF4)4, where L=2-(diphenylphosphino)-5- methylpyridine, are distinguished in the respective mass spectrum, accompanied by some fragment ion peaks. In addition, the mass-to-charge ratios of the parent ions are determi- nated. Preliminary results suggest that the device is a powerful tool for the study of metal cluster compounds. It turns out that the information obtained by the instrumentation serves as an essential supplement to single crystal X-ray diffraction for structure characterization of metal cluster compounds.展开更多
To study ultrafast processes at the sub-picosecond level, novel methods based on coherent harmonic generation technologies have been proposed to generate ultrashort radiation pulses in existing ring-based light source...To study ultrafast processes at the sub-picosecond level, novel methods based on coherent harmonic generation technologies have been proposed to generate ultrashort radiation pulses in existing ring-based light sources. Using the High Energy Photon Source as an example, we numerically test the feasibility of implementing one coherent harmonic generation technology, i.e.,the echo-enabled harmonic generation(EEHG) scheme, in a diffraction-limited storage ring(DLSR). Two different EEHG element layouts are considered, and the effect of the EEHG process on the electron beam quality is also analyzed. Studies suggest that soft X-ray pulses, with pulse lengths of a few femtoseconds and peak powers of up to1 MW, can be generated by using the EEHG scheme, while causing little perturbation to the regular operation of a DLSR.展开更多
文摘The advantages of a flat-panel X-ray source(FPXS)make it a promising candidate for imaging applications.Accurate imaging-system modeling and projection simulation are critical for analyzing imaging performance and resolving overlapping projection issues in FPXS.The conventional analytical ray-tracing approach is limited by the number of patterns and is not applicable to FPXS-projection calculations.However,the computation time of Monte Carlo(MC)simulation is independent of the size of the patterned arrays in FPXS.This study proposes two high-efficiency MC projection simulators for FPXS:a graphics processing unit(GPU)-based phase-space sampling MC(gPSMC)simulator and GPU-based fluence sampling MC(gFSMC)simulator.The two simulators comprise three components:imaging-system modeling,photon initialization,and physical-interaction simulations in the phantom.Imaging-system modeling was performed by modeling the FPXS,imaging geometry,and detector.The gPSMC simulator samples the initial photons from the phase space,whereas the gFSMC simulator performs photon initialization from the calculated energy spectrum and fluence map.The entire process of photon interaction with the geometry and arrival at the detector was simulated in parallel using multiple GPU kernels,and projections based on the two simulators were calculated.The accuracies of the two simulators were evaluated by comparing them with the conventional analytical ray-tracing approach and acquired projections,and the efficiencies were evaluated by comparing the computation time.The results of simulated and realistic experiments illustrate the accuracy and efficiency of the proposed gPSMC and gFSMC simulators in the projection calculation of various phantoms.
文摘Distributed X-ray sources comprise a single vacuum chamber containing multiple X-ray sources that are triggered and emit X-rays at a specific time and location. This process facilitates an application for innovative system concepts in X-ray and computer tomography. This paper proposes a novel electron beam focusing, shaping,and deflection electron gun for distributed X-ray sources.The electron gun uses a dispenser cathode as an electron emitter, a mesh grid to control emission current, and two electrostatic lenses for beam shaping, focusing, and deflection. Novel focusing and deflecting electrodes were designed to increase the number of focal spots in the distributed source. Two identical half-rectangle opening electrodes are controlled by adjusting the potential of the two electrodes to control the electron beam trajectory, and then, multifocal spots are obtained on the anode target. The electron gun can increase the spatial density of the distributed X-ray sources, thereby improving the image quality. The beam experimental results show that the focal spot sizes of the deflected(deflected amplitude 10.5 mm)and non-deflected electron beams at full width at half maximum are 0.80 mm 90.50 mm and 0.55 mm 90.40 mm, respectively(anode voltage 160 kV; beam current 30 mA). The imaging experimental results demonstrate the excellent spatial resolution and time resolution of an imaging system built with the sources, which has an excellent imaging effect on a field-programmable gate array chip and a rotating metal disk.
文摘An experiment with thin titanium foils irradiated by two pulses delayed in time is conducted on the bnenguang-Il laser facility. A prepulse induces an underdense plasma, 2-ns later a main pulse (λL ≈ 0.35 μm, EL ≈120 J, τL ≈100 ps) is injected into the underdense plasma and produces strong line emission from the titanium K shell (i.e., Hea at 4.7 keV). Data show that the intensity of 4.7-keV X-ray emission with the prepulse is approximately twice more than without the prepulse, and can be used as a backlighting source satisfying the diagnostic requirements for dense plasma probing. High- quality plasma images are obtained with the backlighfing 4.7-keV X-rays in a Rayleigh-Taylor hydrodynamic instability experiment.
基金supported by Dr.Guohua Cao’s CAREER award from the U.S.National Science Foundation(CBET 1351936)
文摘Although discovered more than 100 years ago, X-ray source technology has evolved rather slowly. The recent invention of the carbon nanotube (CNT) X-ray source technology holds great promise to revolutionize the field of biomedical X-ray imaging. CNT X-ray sources have been successfully adapted to several biomedical imaging applications including dynamic rnicro-CT of small animals and stationary breast tomosynthesis of breast cancers. Yet their more irnportant biomedical imaging applications still lie ahead in the future, with the devel- oprnent of stationary rnulti-source CT as a noteworthy exarnple.
基金This work is supported in part by the National Natural Science Foundation of China under Grant No. 69978023.
文摘A possible novel application of hard x-ray emitted during laser-plasma interaction was discussed. We established an Optical Transform Function to study the joint effect of the spectral distribution and temporal profile of the laser-produced x-ray on x-ray phase imaging. Though the laser-produced x-ray pulse duration is short and incoherent, the analysis confirms that the current x-ray phase imaging theory still holds for laser-produced x-ray phase imaging.
文摘X-Ray sources, detectors and optical components are now used in a wide range of applications. What is crucial is the absolute calibration of such devices to permit a quantitative assessment of the system under study. A new X-ray laboratory has been built in Frascati (ENEA) to develop diagnostics for nuclear fusion experiments and study applications of these X-ray techniques in other domains, like new material science, non destructive tests and so on. An in-house developed selfconsistent calibration procedure is described that permits the absolute calibration of sources (X-ray emitted fluxes) and detectors (detection efficiencies) as function of the X-ray photon energy, in the range 2 - 120 keV. The calibration procedure involves the use of an in-house developed code that also predicts the spectral response of any detector in any experimental condition that can be setup in the laboratory. The procedure has been then applied for the calibration and characterisation of gas and solid state imaging detectors, such as Medipix-2, GEM gas detector, CCD camera, Cd-Te C-MOS imager, demonstrating the versatility of the method developed here.
基金Project supported by the National Natural Science Foundation of China (Grant No 10035030).
文摘Z-pinch experiments with two arrays consisting, respectively, of 32 4-μm- and 6-μm-diameter tungsten wires have been carried out on QiangGuang-1 facility with a current rising up to 1.5 MA in 80 ns. At early time of implosion, x-ray framing images show that the initial emission comes from the central part of arrays, and double clear emission rings, drifting to the anode and the cathode at 5×10^6 cm/s and 2.4×10^7 cm/s respectively, are often produced near the electrodes. Later, in a 4-μm-diameter tungsten wire array, filamentation caused by ohmic heating is prominent, and more than ten filaments have been observed. A radial inward shift of arrays starts at about 30 ns earlier than the occurrence of the x-ray peak power for both kinds of arrays, and the shrinkage rate of emission region is as high as 1.7×107 cm/s in a 4-μm-diameter tungsten wire array, which is two times higher than that in a 6-μm one. Emission from precursor plasmas is observed in implosion of 6-μm-diameter tungsten wire arrays, but not in implosion of a 4- μm-diameter tungsten wire array. Whereas, in a 4-μm-diameter tungsten wire array, the soft x-ray emission shows the growth of m=l instability in the plasma column, which is caused by current. The reasons for the discrepancy between implosions of 4-μm- and 6-μm-diameter tungsten wire arrays are explained.
基金supported by the National Natural Science Foundation of China (Grant No. 10635050)the Foundation for the Author of National Excellent Doctoral Dissertation of China (Grant No. 200748)+2 种基金the International Atomic Energy Agency (Grant No. 14509)the Postdoctoral Science Foundation of China (Grant No. 20090450355)the Special Research Fund for the Doctoral Program of Higher Education,China (Grant No. 200800030037)
文摘Two 50-μm Mo wires in parallel used as a Z-pinch load are electrically exploded with a pulsed current rising to 275 kA in 125 ns and their explosion processes are backlighted using an X-pinch as an x-ray source. The backlighting images show clearly the processes similar to those occurring in the initial stages of a cylindrical wire-array Z-pinch, including the electric explosion of single wires characterised by the dense wire cores surrounded by a low-density coronal plasma, the expansion of the exploding wire, the sausage instability (m = 0) in the coronal plasma around each wire, the motion of the coronal plasma as well as the wire core toward the current centroid, the formation of the precursor plasma column with a twist structure something like that of higher mode instability, especially the kink instability (m = 1).
基金supported by the National Natural Science Foundation of China (Grant nos. 41306205 and 40176136)the Polar Science Strategic Research Foundation of China (Grant no. 20120306)the Chinese Polar Environment Comprehensive lnvestigation & Assessment Programmes (Grant no. CHINARE 2014-0302)
文摘Mineralogical analysis was performed on bulk sediments of 79 surface samples using X-ray diffraction. The analytical results, combined with data on ocean currents and the regional geological background, were used to investigate the mineral sources. Mineral assemblages in sediments and their distribution in the study area indicate that the material sources are complex. (1) Feldspar is abundant in the sediments of the middle Chukchi Sea near the Bering Strait, originating from sediments in the Anadyr River carried by the Anadyr Current. Sediments deposited on the western side of the Chukchi Sea are rich in feldspar. Compared with other areas, sediments in this region are rich in hornblende transported from volcanic and sedimentary rocks in Siberia by the Anadyr Stream and the Siberian Coastal Current. Sediments in the eastern Chukchi Sea are rich in quartz sourced from sediments of the Yukon and Kuskokwim rivers carried by the Alaska Coastal Current. Sediments in the northern Chukchi Sea are rich in quartz and carbonates from the Mackenzie River sediments. (2) Sediments of the southern and central Canada Basin contain little calcite and dolomite, mainly due to the small impact of the Beaufort Gyre carrying carbonates from the Canadian Arctic Islands. Compared with other areas, the mica content in the region is high, implying that the Laptev Sea is the main sediment source for the southern and central Canada Basin. In the other deep sea areas, calcite and dolomite levels are high caused by the input of large amounts of sediment carried by the Beaufort Gyre from the Canadian Arctic Islands (Banks and Victoria). The Siberian Laptev Sea also provides small amounts of sediment for this region. Furthermore, the Atlantic mid-water contributes some fine-grained material to the entire deep western Arctic Ocean.
基金supported by the National High Technology Development Program of China (Grant No. 2009AA8046006)
文摘Several experiments are performed on the ShenGuang-Ⅱ laser facility to investigate an x-ray source and test radiography concepts. X-ray lines emitted from laser-produced plasmas are the most practical means of generating these high intensity sources. By using a time-integrated space-resolved keV spectroscope and pinhole camera, potential helium-like titanium Kα x-ray backlighting (radiography) line source is studied as a function of laser wavelength, ratio of pre-pulse intensity to main pulse intensity, and laser intensity (from 7.25 to ~ 11.3 × 10^15 W/cm2). One-dimensional radiography using a grid consisting of 5 #m Au wires on 16 μm period and the pinhole-assisted point projection is tested. The measurements show that the size of the helium-like titanium Ka source from a simple foil target is larger than 100 ~m, and relative x-ray line emission conversion efficiency ~x from the incident laser light energy to helium- like titanium K-shell spectrum increases significantly with pre-pulse intensity increasing, increases rapidly with laser wavelength decreasing, and increases moderately with main laser intensity increasing. It is also found that a gold gird foils can reach an imaging resolution better than 5-μm featured with high contrast. It is further demonstrated that the pinhole-assisted point projection at such a level will be a novel two-dimensional imaging diagnostic technique for inertial confinement fusion experiments.
文摘In order to acquire a broadband absorption spectrum in a single shot,a compact radiation source was developed by using a Z-pinch type electric discharge.This paper presents the mechanical and electrical construction of the source,as well as its electrical and optical characteristics,including the intense continuum of radiation emitted by the source in the UV and visible spectral range.It also shows that the compactness of the source allows direct coupling with the probed medium,enabling broadband absorption measurement in the spectral range of 200e300 nm without use of an optical fiber which strongly attenuates the light in the short wavelength range.Concretely,thanks to this source,broadband spectral absorption of NO molecules around 210 nm and that of OH molecules around 310 nm were recorded in this direct coupling arrangement.Copper atom spectral absorption around 325 nm of the peripheral cold zones of an intense transient arc was also recorded.
基金This work was supported by the National Natural Science Foundation of China(No.11922504).
文摘A 2856-MHz,π-mode,seven-cell standingwave deflecting cavity was designed and fabricated for bunch length measurement in Tsinghua Thomson scattering X-ray source(TTX)facility.This cavity was installed in the TTX and provided a deflecting voltage of 4.2 MV with an input power of 2.5 MW.Bunch length diagnoses of electron beams with energies up to 39 MeV have been performed.In this article,the RF design of the cavity using HFSS,fabrication,and RF test processes are reviewed.High-power operation with accelerated beams and calibration of the deflecting voltage are also presented.
文摘An X-ray radiation source with approximately constant radiation temperature is realized by irradiating golden hohlraum with a shaped laser pulse. A simple theoretical model based on power balance is used to design the shape of the drive laser pulse. Experiments are carried out on the Shenguang III prototype laser facility, and the experimentM results are presented for radiation sources with the flat-top lasting about 2.5 ns at two different peak temperatures of about 150 eV and 170 eV, respectively, including the the drive laser pulses and the time integrated possible improvements are discussed. time histories of the temperatures, the shapes of radiation spectra. The validity of the model and
基金Project supported by the National Natural Science Foundation of China(Grant Nos.10902010 and 10975121)the Foundation of China Academy of Engineering Physics(CAEP)(Grant No.2009A0102003)the Foundation of Laboratory of Science and Technology on Plasma Physics,RCLF,CAEP(Grant No.9140C680305120C68252)
文摘Energy spectra, angular distributions, and temporal profiles of the photons produced by an all-optical Thomson scat- tering X-ray source are explored through numerical simulations based on the parameters of the SILEX-I laser system (800 nm, 30 fs, 300 TW) and the previous wakefield acceleration experimental results. The simulation results show that X-ray pulses with a duration of 30 fs and an emission angle of 50 mrad can be produced from such a source. Using the optimized electron parameters, X-ray pulses with better directivity and narrower energy spectra can be obtained. Besides the electron parameters, the laser parameters such as the wavelength, pulse duration, and spot size also affect the X-ray yield, the angular distribution, and the maximum photon energy, except the X-ray pulse duration which is slightly changed for the case of ultrafast laser-electron interaction.
基金This work was partially supported by Quaid-i-Azam University Research Grant, Ministry of Science & Technology Grant, Pakistan Science Foundation Project No. PSF/R&D/C-QU/Phys (199), Higher Education Commission Project for Plasma Physics, Pakistan Atomic
文摘Study on X-ray emission from a low energy (1.8 kJ) plasma focus devicepowered by a 9 μF capacitor bank, charged at 20 kV and giving peak discharge current of about 175kA by using a lead-inserted copper-tapered anode is reported. The X-ray yield in different energywindows is measured as a function of hydrogen filling pressure. The maximum yield in 4π-geometry isfound to be (27.3+-1.1) J and corresponding wall plug efficiency for X-ray generation is 1.52+-0.06%. X-ray emission, presumably due to bombarding activity of electrons in current sheath at theanode tip was dominant, which is confirmed by the pinhole images. The feasibility of the device asan intense X-ray source for radiography is demonstrated.
基金supported by the Major Program of the National Natural Science Foundation of China(Grant No 60532090)the National Natural Science Foundation of China(Grant No 60771048)
文摘This paper studies the properties of a kind of portable ultra-bright microfocus x-ray source with the Monte-Carlo method in detail. The new x-ray source consists of an electron-emission system, an electrostatic focusing system and a metal target. A crystal Lanthanum Hexaboride cathode, a Wehnelt grid and an extracted electrode compose the triode electrode electron-gun system. Two equal radius cylinder electrodes form the focusing system. The key factors determining the focus properties of the electron beam such as the ratio Dw/H, grid bias Vg, and the properties of the extracted electrode arc numerically studied. The calculated results reveal that when Dw/H, Vg, the length of the extracted electrode, and the distance between the grid and the extracted electrode equals 5, q).6 kV, 10 mm, and 8 mm respectively, the electron beam focal spot can be concentrated down to 9 μm in radius and a reasonable focal length about 72.5 mm can be achieved, at the same time, the cathode emission currents can be as high as 30 mA.
文摘X-ray in-line phase contrast imaging enables weakly to absorb specimens to be imaged successfully with high resolution and definition. In this paper we use computer simulation method to analyze how each parameter influences the quality of the image. It can avoid wasting unnecessary time and materials in the course of experiment to get ideal images.
文摘An experiment facility has been set up for the study of metal cluster compounds in our laboratory, which consists of a nano-electrospray ionization source, an ion transmission and focus system, and a reflectron time-of-fight mass spectrometer. Taking advantage of the nano-electrospray ionization source, polyvalent ions are usually produced in the "ionization" process and the obtained mass resolution of the equipment is over 8000. The molecular ion peaks of metal cluster compounds [Au20(PPhpy2)10Cl2](SbF6)4, where PPhpy2=bis(2- pyridyl)phenylphosphine, and [AuaAg2(C)L6](BF4)4, where L=2-(diphenylphosphino)-5- methylpyridine, are distinguished in the respective mass spectrum, accompanied by some fragment ion peaks. In addition, the mass-to-charge ratios of the parent ions are determi- nated. Preliminary results suggest that the device is a powerful tool for the study of metal cluster compounds. It turns out that the information obtained by the instrumentation serves as an essential supplement to single crystal X-ray diffraction for structure characterization of metal cluster compounds.
基金supported by National Natural Science Foundation of China(No.11475202,11405187)the Youth Innovation Association of Chinese Academy of SciencesKey Research Program of Frontier Sciences,CAS(No.QYZDJ-SSW-SLH001)
文摘To study ultrafast processes at the sub-picosecond level, novel methods based on coherent harmonic generation technologies have been proposed to generate ultrashort radiation pulses in existing ring-based light sources. Using the High Energy Photon Source as an example, we numerically test the feasibility of implementing one coherent harmonic generation technology, i.e.,the echo-enabled harmonic generation(EEHG) scheme, in a diffraction-limited storage ring(DLSR). Two different EEHG element layouts are considered, and the effect of the EEHG process on the electron beam quality is also analyzed. Studies suggest that soft X-ray pulses, with pulse lengths of a few femtoseconds and peak powers of up to1 MW, can be generated by using the EEHG scheme, while causing little perturbation to the regular operation of a DLSR.