The measurement of cholesterol and triglycerides in blood by Z-scan technique is proposed.The nonlinear refractive index of cholesterol and triglycerides was found to vary linearly with concentration.Hence by calculat...The measurement of cholesterol and triglycerides in blood by Z-scan technique is proposed.The nonlinear refractive index of cholesterol and triglycerides was found to vary linearly with concentration.Hence by calculating the nonlinear refractive index it is possible to measure their concentration in the sample.These measured values are found in equivalence with conventional colorimetric method.展开更多
The third-order optical nonlinearities of [(CH3)4N]Au(dmit)2 (dmit = 4,5-dithiolate-1,3-dithiole-2-thione) at 532 nm and 1064 nm are investigated using the Z-scan technique with pulses of picoseconds duration. T...The third-order optical nonlinearities of [(CH3)4N]Au(dmit)2 (dmit = 4,5-dithiolate-1,3-dithiole-2-thione) at 532 nm and 1064 nm are investigated using the Z-scan technique with pulses of picoseconds duration. The Z-scan spectra reveal a strong nonlinear absorption (reverse saturable absorption) and a negative nonlinear refraction at 532 nm. No nonlinear absorption is observed at 1064 nm. The molecular second-order hyperpolarizability γ for the [(CH3)4N]Au(dmit)2 molecule at 532nm is estimated to be as high as (2.1 ±0.1) × 10^-31 esu, which is nearly three times larger than that at 1064 nm. The mechanism responsible for the difference between the results is analysed. Nonlinear transmission measurements suggest that this material has potential applications in optical limiting.展开更多
The nonlinear optical properties of a phosphate vitreous system [(ZnO)x-(MgO)30-x-(P2O5)70], where x=8, 10, 15, 18, and 20 mol% synthesized through the melt-quenching technique have been investigated by using th...The nonlinear optical properties of a phosphate vitreous system [(ZnO)x-(MgO)30-x-(P2O5)70], where x=8, 10, 15, 18, and 20 mol% synthesized through the melt-quenching technique have been investigated by using the Z-scan technique. In the experiment, a continuous-wave laser with a wavelength of 405 nm was utilized to determine the sign and value of the nonlinear refractive (NLR) index and the absorption coefficient with closed and opened apertures of the Z-scan setup. The NLR index was found to increase with the ZnO concentration in the glass samples by an order of 10-10 cm2·W-1. The real and imaginary parts of the third-order nonlinear susceptibility were calculated by referring to the NLR index (n2) and absorption coefficient (β) of the samples. The value of the third-order nonlinear susceptibility was presented by nonlinear refractive or absorptive behavior of phosphate glasses for proper utilization in nonlinear optical devices. Based on the measurement, the positive sign of the NLR index shows a self-focusing phenomenon. The figures of merit for each sample were calculated to judge the potential of phosphate glasses for application in optical switching.展开更多
We present a theoretical model to analyse the propagation of a Gaussian laser beam through double-sided nonlinear media. This model is based on the Huygens-Fresnel diffraction integral method. This theoretical model i...We present a theoretical model to analyse the propagation of a Gaussian laser beam through double-sided nonlinear media. This model is based on the Huygens-Fresnel diffraction integral method. This theoretical model is not only consistent with the cascade structure model for a small nonlinear phase-shift but also can be used for a large nonlinear phase-shift. It has been verified that it is suitable to characterize the double-sided nonlinear media compared with the cascade structure model. A good agreement between the experimental data and the results from the theoretical model is obtained. It will be useful for the design of multi-sided nonlinear materials.展开更多
The third-order nonlinear optical properties of two dmit organometallic complexes, [(CH3)4N] [Au(C3S5)2] (MeAu) and [(CH3)4N][Ni(C3S5)2] (Me Ni) in acetone solutions, were characterized us- ing a short pulse Z-scan te...The third-order nonlinear optical properties of two dmit organometallic complexes, [(CH3)4N] [Au(C3S5)2] (MeAu) and [(CH3)4N][Ni(C3S5)2] (Me Ni) in acetone solutions, were characterized us- ing a short pulse Z-scan technique at 1064 nm wavelength. Self-defocusing effects were found in both samples and stronger saturable absorp-tion was observed in MeNi solution comparing with that of MeAu. The origins were analyzed for the differences between the results. Two figures of merit W and T were also calculated to evalu-ate the suitability of two materials for all-optical integrated devices. The results of W=22.84 and T≈0 of MeAu make it an excellent candidate for the all-optical applications.展开更多
Z-scan technique is an effective tool for measuring the optical nonlinearity of the materials. By using this technique the measurement was made for total protein and albumin. The nonlinear refractive index of the tota...Z-scan technique is an effective tool for measuring the optical nonlinearity of the materials. By using this technique the measurement was made for total protein and albumin. The nonlinear refractive index of the total protein and albumin were found to vary linearly with concentration. Hence by calculating the nonlinear refractive index it is possible to measure their concentration in the sample. The values measured thus are found in equivalence with conventional colorimetric method.展开更多
This paper reports the theoretical study of combining Z-scan technique with Gauss-Bessel (GB) beams beside a phase object (PO) to measure the third-order nonlinear susceptibility components. By using this method, ...This paper reports the theoretical study of combining Z-scan technique with Gauss-Bessel (GB) beams beside a phase object (PO) to measure the third-order nonlinear susceptibility components. By using this method, the sign of refractive index which depends on the shape of the close aperture Z-scan curve can be easily determined. Meanwhile, the magnitude of nonlinear coefficients can also be deduced by theoretical fit. The proposed method is advantageous for high sensitivity and imposes a lower stress in the cases of fragile materials, since small pulse energy is enough for the measurement of nonlinear coefficients. Predictions of the models are compared with Gaussian Z-scan measurement and GB Z-scan measurement. By using GB beams with a PO, the sensitivity of Z-scan measurements is found to be a factor of over 60 times greater than for Gaussian beams and 2 times greater than for Gaussian-Bessel beams.展开更多
The development of intestinal anastomosis techniques,including hand suturing,stapling,and compression anastomoses,has been a significant advancement in surgical practice.These methods aim to prevent leakage and minimi...The development of intestinal anastomosis techniques,including hand suturing,stapling,and compression anastomoses,has been a significant advancement in surgical practice.These methods aim to prevent leakage and minimize tissue fibrosis,which can lead to stricture formation.The healing process involves various phases:hemostasis and inflammation,proliferation,and remodeling.Mechanical staplers and sutures can cause inflammation and fibrosis due to the release of profibrotic chemokines.Compression anastomosis devices,including those made of nickel-titanium alloy,offer a minimally invasive option for various surgical challenges and have shown safety and efficacy.However,despite advancements,anastomotic techniques are evaluated based on leakage risk,with complications being a primary concern.Newer devices like Magnamosis use magnetic rings for compression anastomosis,demonstrating greater strength and patency compared to stapling.Magnetic technology is also being explored for other medical treatments.While there are promising results,particularly in animal models,the realworld application in humans is limited,and further research is needed to assess their safety and practicality.展开更多
Epilepsy can be defined as a dysfunction of the brain network,and each type of epilepsy involves different brain-network changes that are implicated diffe rently in the control and propagation of interictal or ictal d...Epilepsy can be defined as a dysfunction of the brain network,and each type of epilepsy involves different brain-network changes that are implicated diffe rently in the control and propagation of interictal or ictal discharges.Gaining more detailed information on brain network alterations can help us to further understand the mechanisms of epilepsy and pave the way for brain network-based precise therapeutic approaches in clinical practice.An increasing number of advanced neuroimaging techniques and electrophysiological techniques such as diffusion tensor imaging-based fiber tra ctography,diffusion kurtosis imaging-based fiber tractography,fiber ball imagingbased tra ctography,electroencephalography,functional magnetic resonance imaging,magnetoencephalography,positron emission tomography,molecular imaging,and functional ultrasound imaging have been extensively used to delineate epileptic networks.In this review,we summarize the relevant neuroimaging and neuroelectrophysiological techniques for assessing structural and functional brain networks in patients with epilepsy,and extensively analyze the imaging mechanisms,advantages,limitations,and clinical application ranges of each technique.A greater focus on emerging advanced technologies,new data analysis software,a combination of multiple techniques,and the construction of personalized virtual epilepsy models can provide a theoretical basis to better understand the brain network mechanisms of epilepsy and make surgical decisions.展开更多
Congenital aortic stenosis(cAS)frequently requires intervention during the neonatal or infantile period.However,surgical repair is challenging because of the narrow surgical space.We performed bicuspidization using th...Congenital aortic stenosis(cAS)frequently requires intervention during the neonatal or infantile period.However,surgical repair is challenging because of the narrow surgical space.We performed bicuspidization using the open-sleeve technique for cAS with a unicuspid aortic valve in two patients.Postoperatively,the patients were doing well without reintervention for the aortic valve for 8 and 6 years,respectively.Their aortic annular diameter increased along with somatic growth.Bicuspidization for neonates or infancy can be performed safely using the open-sleeve technique as its midterm results have been satisfactory.展开更多
The widespread adoption of the Internet of Things (IoT) has transformed various sectors globally, making themmore intelligent and connected. However, this advancement comes with challenges related to the effectiveness...The widespread adoption of the Internet of Things (IoT) has transformed various sectors globally, making themmore intelligent and connected. However, this advancement comes with challenges related to the effectiveness ofIoT devices. These devices, present in offices, homes, industries, and more, need constant monitoring to ensuretheir proper functionality. The success of smart systems relies on their seamless operation and ability to handlefaults. Sensors, crucial components of these systems, gather data and contribute to their functionality. Therefore,sensor faults can compromise the system’s reliability and undermine the trustworthiness of smart environments.To address these concerns, various techniques and algorithms can be employed to enhance the performance ofIoT devices through effective fault detection. This paper conducted a thorough review of the existing literature andconducted a detailed analysis.This analysis effectively links sensor errors with a prominent fault detection techniquecapable of addressing them. This study is innovative because it paves theway for future researchers to explore errorsthat have not yet been tackled by existing fault detection methods. Significant, the paper, also highlights essentialfactors for selecting and adopting fault detection techniques, as well as the characteristics of datasets and theircorresponding recommended techniques. Additionally, the paper presents amethodical overview of fault detectiontechniques employed in smart devices, including themetrics used for evaluation. Furthermore, the paper examinesthe body of academic work related to sensor faults and fault detection techniques within the domain. This reflectsthe growing inclination and scholarly attention of researchers and academicians toward strategies for fault detectionwithin the realm of the Internet of Things.展开更多
Hypoparathyroidism is one of the main complications after total thyroidectomy,severely affecting patients’quality of life.How to effectively protect parathyroid function after surgery and reduce the incidence of hypo...Hypoparathyroidism is one of the main complications after total thyroidectomy,severely affecting patients’quality of life.How to effectively protect parathyroid function after surgery and reduce the incidence of hypoparathyroidism has always been a key research area in thyroid surgery.Therefore,precise localization of parathyroid glands during surgery,effective imaging,and accurate surgical resection have become hot topics of concern for thyroid surgeons.In response to this clinical phenomenon,this study compared several different imaging methods for parathyroid surgery,including nanocarbon,indocyanine green,near-infrared imaging techniques,and technetium-99m methoxyisobutylisonitrile combined with gamma probe imaging technology.The advantages and disadvantages of each method were analyzed,providing scientific recommendations for future parathyroid imaging.In recent years,some related basic and clinical research has also been conducted in thyroid surgery.This article reviewed relevant literature and provided an overview of the practical application progress of various imaging techniques in parathyroid surgery.展开更多
BACKGROUND The magnetic compression technique has been used to establish an animal model of tracheoesophageal fistula(TEF),but the commonly shaped magnets present limitations of poor homogeneity of TEF and poor model ...BACKGROUND The magnetic compression technique has been used to establish an animal model of tracheoesophageal fistula(TEF),but the commonly shaped magnets present limitations of poor homogeneity of TEF and poor model control.We designed a Tshaped magnet system to overcome these problems and verified its effectiveness via animal experiments.AIM To investigate the effectiveness of a T-shaped magnet system for establishing a TEF model in beagle dogs.METHODS Twelve beagles were randomly assigned to groups in which magnets of the Tshaped scheme(study group,n=6)or normal magnets(control group,n=6)were implanted into the trachea and esophagus separately under gastroscopy.Operation time,operation success rate,and accidental injury were recorded.After operation,the presence and timing of cough and the time of magnet shedding were observed.Dogs in the control group were euthanized after X-ray and gastroscopy to confirm establishment of TEFs after coughing,and gross specimens of TEFs were obtained.Dogs in the study group were euthanized after X-ray and gastroscopy 2 wk after surgery,and gross specimens were obtained.Fistula size was measured in all animals,and then harvested fistula specimens were examined by hematoxylin and eosin(HE)and Masson trichrome staining.RESULTS The operation success rate was 100%for both groups.Operation time did not differ between the study group(5.25 min±1.29 min)and the control group(4.75 min±1.70 min;P=0.331).No bleeding,perforation,or unplanned magnet attraction occurred in any animal during the operation.In the early postoperative period,all dogs ate freely and were generally in good condition.Dogs in the control group had severe cough after drinking water at 6-9 d after surgery.X-ray indicated that the magnets had entered the stomach,and gastroscopy showed TEF formation.Gross specimens of TEFs from the control group showed the formation of fistulas with a diameter of 4.94 mm±1.29 mm(range,3.52-6.56 mm).HE and Masson trichrome staining showed scar tissue formation and hierarchical structural disorder at the fistulas.Dogs in the study group did not exhibit obvious coughing after surgery.X-ray examination 2 wk after surgery indicated fixed magnet positioning,and gastroscopy showed no change in magnet positioning.The magnets were removed using a snare under endoscopy,and TEF was observed.Gross specimens showed well-formed fistulas with a diameter of 6.11 mm±0.16 mm(range,5.92-6.36 mm),which exceeded that in the control group(P<0.001).Scar formation was observed on the internal surface of fistulas by HE and Masson trichrome staining,and the structure was more regular than that in the control group.CONCLUSION Use of the modified T-shaped magnet scheme is safe and feasible for establishing TEF and can achieve a more stable and uniform fistula size compared with ordinary magnets.Most importantly,this model offers better controllability,which improves the flexibility of follow-up studies.展开更多
When a customer uses the software, then it is possible to occur defects that can be removed in the updated versions of the software. Hence, in the present work, a robust examination of cross-project software defect pr...When a customer uses the software, then it is possible to occur defects that can be removed in the updated versions of the software. Hence, in the present work, a robust examination of cross-project software defect prediction is elaborated through an innovative hybrid machine learning framework. The proposed technique combines an advanced deep neural network architecture with ensemble models such as Support Vector Machine (SVM), Random Forest (RF), and XGBoost. The study evaluates the performance by considering multiple software projects like CM1, JM1, KC1, and PC1 using datasets from the PROMISE Software Engineering Repository. The three hybrid models that are compared are Hybrid Model-1 (SVM, RandomForest, XGBoost, Neural Network), Hybrid Model-2 (GradientBoosting, DecisionTree, LogisticRegression, Neural Network), and Hybrid Model-3 (KNeighbors, GaussianNB, Support Vector Classification (SVC), Neural Network), and the Hybrid Model 3 surpasses the others in terms of recall, F1-score, accuracy, ROC AUC, and precision. The presented work offers valuable insights into the effectiveness of hybrid techniques for cross-project defect prediction, providing a comparative perspective on early defect identification and mitigation strategies. .展开更多
BACKGROUND Radical surgery combined with systemic chemotherapy offers the possibility of long-term survival or even cure for patients with pancreatic ductal adenocar-cinoma(PDAC),although tumor recurrence,especially l...BACKGROUND Radical surgery combined with systemic chemotherapy offers the possibility of long-term survival or even cure for patients with pancreatic ductal adenocar-cinoma(PDAC),although tumor recurrence,especially locally,still inhibits the treatment efficacy.The TRIANGLE technique was introduced as an extended dissection procedure to improve the R0 resection rate of borderline resectable or locally advanced PDAC.However,there was a lack of studies concerning postoperative complications and long-term outcomes of this procedure on patients with resectable PDAC.PDAC.METHODS Patients with resectable PDAC eligible for PD from our hospital between June 2018 and December 2021 were enrolled in this retrospective cohort study.All the patients were divided into PDstandard and PDTRIANGLE groups according to the surgical procedure.Baseline characteristics,surgical data,and postoperative morbidities were recorded.All of the patients were followed up,and the date and location of tumor recurrence,and death were recorded.The Kaplan-Meier method and log-rank test were used for the survival analysis.RESULTS There were 93 patients included in the study and 37 underwent the TRIANGLE technique.Duration of operation was longer in the PDTRIANGLE group compared with the PDstandard group[440(410-480)min vs 320(265-427)min](P=0.001).Intraoperative blood loss[700(500-1200)mL vs 500(300-800)mL](P=0.009)and blood transfusion[975(0-1250)mL vs 400(0-800)mL](P=0.009)were higher in the PDTRIANGLE group.There was a higher incidence of surgical site infection(43.2%vs 12.5%)(P=0.001)and postoperative diarrhea(54.1%vs 12.5%)(P=0.001)in the PDTRIANGLE group.The rates of R0 resection and local recurrence,overall survival,and disease-free survival did not differ significantly between the two groups.CONCLUSION The TRIANGLE technique is safe,with acceptable postoperative morbidities compared with standardized PD,but it does not improve prognosis for patients with resectable PDAC.展开更多
BACKGROUND Developmental dysplasia of the hip(DDH)is a common osteoarticular deformity in pediatric orthopedics.A patient with bilateral DDH was diagnosed and treated using our improved technique"(powerful overtu...BACKGROUND Developmental dysplasia of the hip(DDH)is a common osteoarticular deformity in pediatric orthopedics.A patient with bilateral DDH was diagnosed and treated using our improved technique"(powerful overturning acetabuloplasty)"combined with femoral rotational shortening osteotomy.CASE SUMMARY A 4-year-old girl who was diagnosed with bilateral DDH could not stand normally,and sought surgical treatment to solve the problem of double hip extension and standing.As this child had high dislocation of the hip joint and the acetabular index was high,we changed the traditional acetabuloplasty to"powerful turnover acetabuloplasty"combined with femoral rotation shortening osteotomy.During the short-term postoperative follow-up(1,3,6,9,12,and 15 months),the child had no discomfort in her lower limbs.After the braces and internal fixation plates were removed,formal rehabilitation training was actively carried out.CONCLUSION Our"powerful overturning acetabuloplasty"combined with femoral rotational shortening osteotomy is feasible in the treatment of DDH in children.This technology may be widely used in the clinic.展开更多
Chinese chive is a kind of medicinal and edible plant,with many diseases,and chemical fungicides are usually used for control.In order to find out the risk of pesticide residues in Chinese chives,this paper summarized...Chinese chive is a kind of medicinal and edible plant,with many diseases,and chemical fungicides are usually used for control.In order to find out the risk of pesticide residues in Chinese chives,this paper summarized relevant literatures published in recent years,and sorted out and analyzed the types of pesticides used and detection techniques of common diseases in Chinese chives.展开更多
Reliable long-term settlement prediction of a high embankment relates to mountain infrastructure safety.This study developed a novel hybrid model(NHM)that combines a joint denoising technique with an enhanced gray wol...Reliable long-term settlement prediction of a high embankment relates to mountain infrastructure safety.This study developed a novel hybrid model(NHM)that combines a joint denoising technique with an enhanced gray wolf optimizer(EGWO)-n-support vector regression(n-SVR)method.High-embankment field measurements were preprocessed using the joint denoising technique,which in-cludes complete ensemble empirical mode decomposition,singular value decomposition,and wavelet packet transform.Furthermore,high-embankment settlements were predicted using the EGWO-n-SVR method.In this method,the standard gray wolf optimizer(GWO)was improved to obtain the EGWO to better tune the n-SVR model hyperparameters.The proposed NHM was then tested in two case studies.Finally,the influences of the data division ratio and kernel function on the EGWO-n-SVR forecasting performance and prediction efficiency were investigated.The results indicate that the NHM suppresses noise and restores details in high-embankment field measurements.Simultaneously,the NHM out-performs other alternative prediction methods in prediction accuracy and robustness.This demonstrates that the proposed NHM is effective in predicting high-embankment settlements with noisy field mea-surements.Moreover,the appropriate data division ratio and kernel function for EGWO-n-SVR are 7:3 and radial basis function,respectively.展开更多
BACKGROUND Previous studies have validated the efficacy of both magnetic compression and surgical techniques in creating rabbit tracheoesophageal fistula(TEF)models.Magnetic compression achieves a 100%success rate but...BACKGROUND Previous studies have validated the efficacy of both magnetic compression and surgical techniques in creating rabbit tracheoesophageal fistula(TEF)models.Magnetic compression achieves a 100%success rate but requires more time,while surgery,though less frequently successful,offers rapid model establishment and technical maturity in larger animal models.AIM To determine the optimal approach for rabbit disease modeling and refine the process.METHODS TEF models were created in 12 rabbits using both the modified magnetic compression technique and surgery.Comparisons of the time to model establishment,success rate,food and water intake,weight changes,activity levels,bronchoscopy findings,white blood cell counts,and biopsies were performed.In response to the failures encountered during modified magnetic compression modeling,we increased the sample size to 15 rabbit models and assessed the repeatability and stability of the models,comparing them with the original magnetic compression technique.RESULTS The modified magnetic compression technique achieved a 66.7%success rate,whereas the success rate of the surgery technique was 33.3%.Surviving surgical rabbits might not meet subsequent experimental requirements due to TEF-related inflammation.In the modified magnetic compression group,one rabbit died,possibly due to magnet corrosion,and another died from tracheal magnet obstruction.Similar events occurred during the second round of modified magnetic compression modeling,with one rabbit possibly succumbing to aggravated lung infection.The operation time of the first round of modified magnetic compression was 3.2±0.6 min,which was significantly reduced to 2.1±0.4 min in the second round,compared to both the first round and that of the original technique.CONCLUSION The modified magnetic compression technique exhibits lower stress responses,a simple procedure,a high success rate,and lower modeling costs,making it a more appropriate choice for constructing TEF models in rabbits.展开更多
Amplitudes have been found to be a function of incident angle and offset. Hence data required to test for amplitude variation with angle or offset needs to have its amplitudes for all offsets preserved and not stacked...Amplitudes have been found to be a function of incident angle and offset. Hence data required to test for amplitude variation with angle or offset needs to have its amplitudes for all offsets preserved and not stacked. Amplitude Variation with Offset (AVO)/Amplitude Variation with Angle (AVA) is necessary to account for information in the offset/angle parameter (mode converted S-wave and P-wave velocities). Since amplitudes are a function of the converted S- and P-waves, it is important to investigate the dependence of amplitudes on the elastic (P- and S-waves) parameters from the seismic data. By modelling these effects for different reservoir fluids via fluid substitution, various AVO geobody classes present along the well and in the entire seismic cube can be observed. AVO analysis was performed on one test well (Well_1) and 3D pre-stack angle gathers from the Tano Basin. The analysis involves creating a synthetic model to infer the effect of offset scaling techniques on amplitude responses in the Tano basin as compared to the effect of unscaled seismic data. The spectral balance process was performed to match the amplitude spectra of all angle stacks to that of the mid (26°) stack on the test lines. The process had an effect primarily on the far (34° - 40°) stacks. The frequency content of these stacks slightly increased to match that of the near and mid stacks. In offset scaling process, the root mean square (RMS) amplitude comparison between the synthetic and seismic suggests that the amplitude of the far traces should be reduced relative to the nears by up to 16%. However, the exact scaler values depend on the time window considered. This suggests that the amplitude scaling with offset delivered from seismic processing is only approximately correct and needs to be checked with well synthetics and adjusted accordingly prior to use for AVO studies. The AVO attribute volumes generated were better at resolving anomalies on spectrally balanced and offset scaled data than data delivered from conventional processing. A typical class II AVO anomaly is seen along the test well from the cross-plot analysis and AVO attribute cube which indicates an oil filled reservoir.展开更多
文摘The measurement of cholesterol and triglycerides in blood by Z-scan technique is proposed.The nonlinear refractive index of cholesterol and triglycerides was found to vary linearly with concentration.Hence by calculating the nonlinear refractive index it is possible to measure their concentration in the sample.These measured values are found in equivalence with conventional colorimetric method.
基金Project supported by the National Natural Science Foundation of China (Grant Nos 60377016 and 60476020) and the National High Technology Development Program of China (Grant No 2002AA313070).
文摘The third-order optical nonlinearities of [(CH3)4N]Au(dmit)2 (dmit = 4,5-dithiolate-1,3-dithiole-2-thione) at 532 nm and 1064 nm are investigated using the Z-scan technique with pulses of picoseconds duration. The Z-scan spectra reveal a strong nonlinear absorption (reverse saturable absorption) and a negative nonlinear refraction at 532 nm. No nonlinear absorption is observed at 1064 nm. The molecular second-order hyperpolarizability γ for the [(CH3)4N]Au(dmit)2 molecule at 532nm is estimated to be as high as (2.1 ±0.1) × 10^-31 esu, which is nearly three times larger than that at 1064 nm. The mechanism responsible for the difference between the results is analysed. Nonlinear transmission measurements suggest that this material has potential applications in optical limiting.
基金Project supported by the Ministry of Higher Education(Grant Nos.1-11-08-664FR/F1 and 01-0410-861FR)
文摘The nonlinear optical properties of a phosphate vitreous system [(ZnO)x-(MgO)30-x-(P2O5)70], where x=8, 10, 15, 18, and 20 mol% synthesized through the melt-quenching technique have been investigated by using the Z-scan technique. In the experiment, a continuous-wave laser with a wavelength of 405 nm was utilized to determine the sign and value of the nonlinear refractive (NLR) index and the absorption coefficient with closed and opened apertures of the Z-scan setup. The NLR index was found to increase with the ZnO concentration in the glass samples by an order of 10-10 cm2·W-1. The real and imaginary parts of the third-order nonlinear susceptibility were calculated by referring to the NLR index (n2) and absorption coefficient (β) of the samples. The value of the third-order nonlinear susceptibility was presented by nonlinear refractive or absorptive behavior of phosphate glasses for proper utilization in nonlinear optical devices. Based on the measurement, the positive sign of the NLR index shows a self-focusing phenomenon. The figures of merit for each sample were calculated to judge the potential of phosphate glasses for application in optical switching.
基金Project supported by the Natural National Science Foundation of China (Grant Nos 20131040 and 50172013), the Heilongjiang Province Science Foundation (Grant No F2004-8), and the 0utstanding Young Research Foundation of Heilongjiang University (Grant No JC200307).
文摘We present a theoretical model to analyse the propagation of a Gaussian laser beam through double-sided nonlinear media. This model is based on the Huygens-Fresnel diffraction integral method. This theoretical model is not only consistent with the cascade structure model for a small nonlinear phase-shift but also can be used for a large nonlinear phase-shift. It has been verified that it is suitable to characterize the double-sided nonlinear media compared with the cascade structure model. A good agreement between the experimental data and the results from the theoretical model is obtained. It will be useful for the design of multi-sided nonlinear materials.
文摘The third-order nonlinear optical properties of two dmit organometallic complexes, [(CH3)4N] [Au(C3S5)2] (MeAu) and [(CH3)4N][Ni(C3S5)2] (Me Ni) in acetone solutions, were characterized us- ing a short pulse Z-scan technique at 1064 nm wavelength. Self-defocusing effects were found in both samples and stronger saturable absorp-tion was observed in MeNi solution comparing with that of MeAu. The origins were analyzed for the differences between the results. Two figures of merit W and T were also calculated to evalu-ate the suitability of two materials for all-optical integrated devices. The results of W=22.84 and T≈0 of MeAu make it an excellent candidate for the all-optical applications.
文摘Z-scan technique is an effective tool for measuring the optical nonlinearity of the materials. By using this technique the measurement was made for total protein and albumin. The nonlinear refractive index of the total protein and albumin were found to vary linearly with concentration. Hence by calculating the nonlinear refractive index it is possible to measure their concentration in the sample. The values measured thus are found in equivalence with conventional colorimetric method.
基金supported by the National Natural Science Fundation of China (Grant No. 90922007)
文摘This paper reports the theoretical study of combining Z-scan technique with Gauss-Bessel (GB) beams beside a phase object (PO) to measure the third-order nonlinear susceptibility components. By using this method, the sign of refractive index which depends on the shape of the close aperture Z-scan curve can be easily determined. Meanwhile, the magnitude of nonlinear coefficients can also be deduced by theoretical fit. The proposed method is advantageous for high sensitivity and imposes a lower stress in the cases of fragile materials, since small pulse energy is enough for the measurement of nonlinear coefficients. Predictions of the models are compared with Gaussian Z-scan measurement and GB Z-scan measurement. By using GB beams with a PO, the sensitivity of Z-scan measurements is found to be a factor of over 60 times greater than for Gaussian beams and 2 times greater than for Gaussian-Bessel beams.
文摘The development of intestinal anastomosis techniques,including hand suturing,stapling,and compression anastomoses,has been a significant advancement in surgical practice.These methods aim to prevent leakage and minimize tissue fibrosis,which can lead to stricture formation.The healing process involves various phases:hemostasis and inflammation,proliferation,and remodeling.Mechanical staplers and sutures can cause inflammation and fibrosis due to the release of profibrotic chemokines.Compression anastomosis devices,including those made of nickel-titanium alloy,offer a minimally invasive option for various surgical challenges and have shown safety and efficacy.However,despite advancements,anastomotic techniques are evaluated based on leakage risk,with complications being a primary concern.Newer devices like Magnamosis use magnetic rings for compression anastomosis,demonstrating greater strength and patency compared to stapling.Magnetic technology is also being explored for other medical treatments.While there are promising results,particularly in animal models,the realworld application in humans is limited,and further research is needed to assess their safety and practicality.
基金supported by the Natural Science Foundation of Sichuan Province of China,Nos.2022NSFSC1545 (to YG),2022NSFSC1387 (to ZF)the Natural Science Foundation of Chongqing of China,Nos.CSTB2022NSCQ-LZX0038,cstc2021ycjh-bgzxm0035 (both to XT)+3 种基金the National Natural Science Foundation of China,No.82001378 (to XT)the Joint Project of Chongqing Health Commission and Science and Technology Bureau,No.2023QNXM009 (to XT)the Science and Technology Research Program of Chongqing Education Commission of China,No.KJQN202200435 (to XT)the Chongqing Talents:Exceptional Young Talents Project,No.CQYC202005014 (to XT)。
文摘Epilepsy can be defined as a dysfunction of the brain network,and each type of epilepsy involves different brain-network changes that are implicated diffe rently in the control and propagation of interictal or ictal discharges.Gaining more detailed information on brain network alterations can help us to further understand the mechanisms of epilepsy and pave the way for brain network-based precise therapeutic approaches in clinical practice.An increasing number of advanced neuroimaging techniques and electrophysiological techniques such as diffusion tensor imaging-based fiber tra ctography,diffusion kurtosis imaging-based fiber tractography,fiber ball imagingbased tra ctography,electroencephalography,functional magnetic resonance imaging,magnetoencephalography,positron emission tomography,molecular imaging,and functional ultrasound imaging have been extensively used to delineate epileptic networks.In this review,we summarize the relevant neuroimaging and neuroelectrophysiological techniques for assessing structural and functional brain networks in patients with epilepsy,and extensively analyze the imaging mechanisms,advantages,limitations,and clinical application ranges of each technique.A greater focus on emerging advanced technologies,new data analysis software,a combination of multiple techniques,and the construction of personalized virtual epilepsy models can provide a theoretical basis to better understand the brain network mechanisms of epilepsy and make surgical decisions.
文摘Congenital aortic stenosis(cAS)frequently requires intervention during the neonatal or infantile period.However,surgical repair is challenging because of the narrow surgical space.We performed bicuspidization using the open-sleeve technique for cAS with a unicuspid aortic valve in two patients.Postoperatively,the patients were doing well without reintervention for the aortic valve for 8 and 6 years,respectively.Their aortic annular diameter increased along with somatic growth.Bicuspidization for neonates or infancy can be performed safely using the open-sleeve technique as its midterm results have been satisfactory.
文摘The widespread adoption of the Internet of Things (IoT) has transformed various sectors globally, making themmore intelligent and connected. However, this advancement comes with challenges related to the effectiveness ofIoT devices. These devices, present in offices, homes, industries, and more, need constant monitoring to ensuretheir proper functionality. The success of smart systems relies on their seamless operation and ability to handlefaults. Sensors, crucial components of these systems, gather data and contribute to their functionality. Therefore,sensor faults can compromise the system’s reliability and undermine the trustworthiness of smart environments.To address these concerns, various techniques and algorithms can be employed to enhance the performance ofIoT devices through effective fault detection. This paper conducted a thorough review of the existing literature andconducted a detailed analysis.This analysis effectively links sensor errors with a prominent fault detection techniquecapable of addressing them. This study is innovative because it paves theway for future researchers to explore errorsthat have not yet been tackled by existing fault detection methods. Significant, the paper, also highlights essentialfactors for selecting and adopting fault detection techniques, as well as the characteristics of datasets and theircorresponding recommended techniques. Additionally, the paper presents amethodical overview of fault detectiontechniques employed in smart devices, including themetrics used for evaluation. Furthermore, the paper examinesthe body of academic work related to sensor faults and fault detection techniques within the domain. This reflectsthe growing inclination and scholarly attention of researchers and academicians toward strategies for fault detectionwithin the realm of the Internet of Things.
基金Supported by The 2024 Hospital Research Funding,No.KYQ2024008.
文摘Hypoparathyroidism is one of the main complications after total thyroidectomy,severely affecting patients’quality of life.How to effectively protect parathyroid function after surgery and reduce the incidence of hypoparathyroidism has always been a key research area in thyroid surgery.Therefore,precise localization of parathyroid glands during surgery,effective imaging,and accurate surgical resection have become hot topics of concern for thyroid surgeons.In response to this clinical phenomenon,this study compared several different imaging methods for parathyroid surgery,including nanocarbon,indocyanine green,near-infrared imaging techniques,and technetium-99m methoxyisobutylisonitrile combined with gamma probe imaging technology.The advantages and disadvantages of each method were analyzed,providing scientific recommendations for future parathyroid imaging.In recent years,some related basic and clinical research has also been conducted in thyroid surgery.This article reviewed relevant literature and provided an overview of the practical application progress of various imaging techniques in parathyroid surgery.
基金Supported by the Key Research&Development Program of Shaanxi Province of China,No.2024SF-YBXM-447Institutional Foundation of The First Affiliated Hospital of Xi’an Jiaotong University,No.2022MS-07+1 种基金Fundamental Research Funds for the Central Universities,No.xzy022023068Natural Science Foundation of Shaanxi Province,No.2023-JC-QN-0814.
文摘BACKGROUND The magnetic compression technique has been used to establish an animal model of tracheoesophageal fistula(TEF),but the commonly shaped magnets present limitations of poor homogeneity of TEF and poor model control.We designed a Tshaped magnet system to overcome these problems and verified its effectiveness via animal experiments.AIM To investigate the effectiveness of a T-shaped magnet system for establishing a TEF model in beagle dogs.METHODS Twelve beagles were randomly assigned to groups in which magnets of the Tshaped scheme(study group,n=6)or normal magnets(control group,n=6)were implanted into the trachea and esophagus separately under gastroscopy.Operation time,operation success rate,and accidental injury were recorded.After operation,the presence and timing of cough and the time of magnet shedding were observed.Dogs in the control group were euthanized after X-ray and gastroscopy to confirm establishment of TEFs after coughing,and gross specimens of TEFs were obtained.Dogs in the study group were euthanized after X-ray and gastroscopy 2 wk after surgery,and gross specimens were obtained.Fistula size was measured in all animals,and then harvested fistula specimens were examined by hematoxylin and eosin(HE)and Masson trichrome staining.RESULTS The operation success rate was 100%for both groups.Operation time did not differ between the study group(5.25 min±1.29 min)and the control group(4.75 min±1.70 min;P=0.331).No bleeding,perforation,or unplanned magnet attraction occurred in any animal during the operation.In the early postoperative period,all dogs ate freely and were generally in good condition.Dogs in the control group had severe cough after drinking water at 6-9 d after surgery.X-ray indicated that the magnets had entered the stomach,and gastroscopy showed TEF formation.Gross specimens of TEFs from the control group showed the formation of fistulas with a diameter of 4.94 mm±1.29 mm(range,3.52-6.56 mm).HE and Masson trichrome staining showed scar tissue formation and hierarchical structural disorder at the fistulas.Dogs in the study group did not exhibit obvious coughing after surgery.X-ray examination 2 wk after surgery indicated fixed magnet positioning,and gastroscopy showed no change in magnet positioning.The magnets were removed using a snare under endoscopy,and TEF was observed.Gross specimens showed well-formed fistulas with a diameter of 6.11 mm±0.16 mm(range,5.92-6.36 mm),which exceeded that in the control group(P<0.001).Scar formation was observed on the internal surface of fistulas by HE and Masson trichrome staining,and the structure was more regular than that in the control group.CONCLUSION Use of the modified T-shaped magnet scheme is safe and feasible for establishing TEF and can achieve a more stable and uniform fistula size compared with ordinary magnets.Most importantly,this model offers better controllability,which improves the flexibility of follow-up studies.
文摘When a customer uses the software, then it is possible to occur defects that can be removed in the updated versions of the software. Hence, in the present work, a robust examination of cross-project software defect prediction is elaborated through an innovative hybrid machine learning framework. The proposed technique combines an advanced deep neural network architecture with ensemble models such as Support Vector Machine (SVM), Random Forest (RF), and XGBoost. The study evaluates the performance by considering multiple software projects like CM1, JM1, KC1, and PC1 using datasets from the PROMISE Software Engineering Repository. The three hybrid models that are compared are Hybrid Model-1 (SVM, RandomForest, XGBoost, Neural Network), Hybrid Model-2 (GradientBoosting, DecisionTree, LogisticRegression, Neural Network), and Hybrid Model-3 (KNeighbors, GaussianNB, Support Vector Classification (SVC), Neural Network), and the Hybrid Model 3 surpasses the others in terms of recall, F1-score, accuracy, ROC AUC, and precision. The presented work offers valuable insights into the effectiveness of hybrid techniques for cross-project defect prediction, providing a comparative perspective on early defect identification and mitigation strategies. .
基金Supported by the National Natural Science Foundation of China,No.31971518.
文摘BACKGROUND Radical surgery combined with systemic chemotherapy offers the possibility of long-term survival or even cure for patients with pancreatic ductal adenocar-cinoma(PDAC),although tumor recurrence,especially locally,still inhibits the treatment efficacy.The TRIANGLE technique was introduced as an extended dissection procedure to improve the R0 resection rate of borderline resectable or locally advanced PDAC.However,there was a lack of studies concerning postoperative complications and long-term outcomes of this procedure on patients with resectable PDAC.PDAC.METHODS Patients with resectable PDAC eligible for PD from our hospital between June 2018 and December 2021 were enrolled in this retrospective cohort study.All the patients were divided into PDstandard and PDTRIANGLE groups according to the surgical procedure.Baseline characteristics,surgical data,and postoperative morbidities were recorded.All of the patients were followed up,and the date and location of tumor recurrence,and death were recorded.The Kaplan-Meier method and log-rank test were used for the survival analysis.RESULTS There were 93 patients included in the study and 37 underwent the TRIANGLE technique.Duration of operation was longer in the PDTRIANGLE group compared with the PDstandard group[440(410-480)min vs 320(265-427)min](P=0.001).Intraoperative blood loss[700(500-1200)mL vs 500(300-800)mL](P=0.009)and blood transfusion[975(0-1250)mL vs 400(0-800)mL](P=0.009)were higher in the PDTRIANGLE group.There was a higher incidence of surgical site infection(43.2%vs 12.5%)(P=0.001)and postoperative diarrhea(54.1%vs 12.5%)(P=0.001)in the PDTRIANGLE group.The rates of R0 resection and local recurrence,overall survival,and disease-free survival did not differ significantly between the two groups.CONCLUSION The TRIANGLE technique is safe,with acceptable postoperative morbidities compared with standardized PD,but it does not improve prognosis for patients with resectable PDAC.
文摘BACKGROUND Developmental dysplasia of the hip(DDH)is a common osteoarticular deformity in pediatric orthopedics.A patient with bilateral DDH was diagnosed and treated using our improved technique"(powerful overturning acetabuloplasty)"combined with femoral rotational shortening osteotomy.CASE SUMMARY A 4-year-old girl who was diagnosed with bilateral DDH could not stand normally,and sought surgical treatment to solve the problem of double hip extension and standing.As this child had high dislocation of the hip joint and the acetabular index was high,we changed the traditional acetabuloplasty to"powerful turnover acetabuloplasty"combined with femoral rotation shortening osteotomy.During the short-term postoperative follow-up(1,3,6,9,12,and 15 months),the child had no discomfort in her lower limbs.After the braces and internal fixation plates were removed,formal rehabilitation training was actively carried out.CONCLUSION Our"powerful overturning acetabuloplasty"combined with femoral rotational shortening osteotomy is feasible in the treatment of DDH in children.This technology may be widely used in the clinic.
基金Supported by Special Project of the Central Government in Guidance of Local Science and Technology Development (Scientific and Technological Innovation Base Project) (226Z5504G)The Fourth Batch of High-end Talent Project in Hebei Province.
文摘Chinese chive is a kind of medicinal and edible plant,with many diseases,and chemical fungicides are usually used for control.In order to find out the risk of pesticide residues in Chinese chives,this paper summarized relevant literatures published in recent years,and sorted out and analyzed the types of pesticides used and detection techniques of common diseases in Chinese chives.
基金We acknowledge the funding support from the National Natural Science Foundation of China(Grant No.51808462)the Natural Science Foundation Project of Sichuan Province,China(Grant No.2023NSFSC0346)the Science and Technology Project of Inner Mongolia Transportation Department,China(Grant No.NJ-2022-14).
文摘Reliable long-term settlement prediction of a high embankment relates to mountain infrastructure safety.This study developed a novel hybrid model(NHM)that combines a joint denoising technique with an enhanced gray wolf optimizer(EGWO)-n-support vector regression(n-SVR)method.High-embankment field measurements were preprocessed using the joint denoising technique,which in-cludes complete ensemble empirical mode decomposition,singular value decomposition,and wavelet packet transform.Furthermore,high-embankment settlements were predicted using the EGWO-n-SVR method.In this method,the standard gray wolf optimizer(GWO)was improved to obtain the EGWO to better tune the n-SVR model hyperparameters.The proposed NHM was then tested in two case studies.Finally,the influences of the data division ratio and kernel function on the EGWO-n-SVR forecasting performance and prediction efficiency were investigated.The results indicate that the NHM suppresses noise and restores details in high-embankment field measurements.Simultaneously,the NHM out-performs other alternative prediction methods in prediction accuracy and robustness.This demonstrates that the proposed NHM is effective in predicting high-embankment settlements with noisy field mea-surements.Moreover,the appropriate data division ratio and kernel function for EGWO-n-SVR are 7:3 and radial basis function,respectively.
基金Independent Scientific Research Project for Graduate Students of Beijing University of Chinese Medicine(2023),No.ZJKT2023020.
文摘BACKGROUND Previous studies have validated the efficacy of both magnetic compression and surgical techniques in creating rabbit tracheoesophageal fistula(TEF)models.Magnetic compression achieves a 100%success rate but requires more time,while surgery,though less frequently successful,offers rapid model establishment and technical maturity in larger animal models.AIM To determine the optimal approach for rabbit disease modeling and refine the process.METHODS TEF models were created in 12 rabbits using both the modified magnetic compression technique and surgery.Comparisons of the time to model establishment,success rate,food and water intake,weight changes,activity levels,bronchoscopy findings,white blood cell counts,and biopsies were performed.In response to the failures encountered during modified magnetic compression modeling,we increased the sample size to 15 rabbit models and assessed the repeatability and stability of the models,comparing them with the original magnetic compression technique.RESULTS The modified magnetic compression technique achieved a 66.7%success rate,whereas the success rate of the surgery technique was 33.3%.Surviving surgical rabbits might not meet subsequent experimental requirements due to TEF-related inflammation.In the modified magnetic compression group,one rabbit died,possibly due to magnet corrosion,and another died from tracheal magnet obstruction.Similar events occurred during the second round of modified magnetic compression modeling,with one rabbit possibly succumbing to aggravated lung infection.The operation time of the first round of modified magnetic compression was 3.2±0.6 min,which was significantly reduced to 2.1±0.4 min in the second round,compared to both the first round and that of the original technique.CONCLUSION The modified magnetic compression technique exhibits lower stress responses,a simple procedure,a high success rate,and lower modeling costs,making it a more appropriate choice for constructing TEF models in rabbits.
文摘Amplitudes have been found to be a function of incident angle and offset. Hence data required to test for amplitude variation with angle or offset needs to have its amplitudes for all offsets preserved and not stacked. Amplitude Variation with Offset (AVO)/Amplitude Variation with Angle (AVA) is necessary to account for information in the offset/angle parameter (mode converted S-wave and P-wave velocities). Since amplitudes are a function of the converted S- and P-waves, it is important to investigate the dependence of amplitudes on the elastic (P- and S-waves) parameters from the seismic data. By modelling these effects for different reservoir fluids via fluid substitution, various AVO geobody classes present along the well and in the entire seismic cube can be observed. AVO analysis was performed on one test well (Well_1) and 3D pre-stack angle gathers from the Tano Basin. The analysis involves creating a synthetic model to infer the effect of offset scaling techniques on amplitude responses in the Tano basin as compared to the effect of unscaled seismic data. The spectral balance process was performed to match the amplitude spectra of all angle stacks to that of the mid (26°) stack on the test lines. The process had an effect primarily on the far (34° - 40°) stacks. The frequency content of these stacks slightly increased to match that of the near and mid stacks. In offset scaling process, the root mean square (RMS) amplitude comparison between the synthetic and seismic suggests that the amplitude of the far traces should be reduced relative to the nears by up to 16%. However, the exact scaler values depend on the time window considered. This suggests that the amplitude scaling with offset delivered from seismic processing is only approximately correct and needs to be checked with well synthetics and adjusted accordingly prior to use for AVO studies. The AVO attribute volumes generated were better at resolving anomalies on spectrally balanced and offset scaled data than data delivered from conventional processing. A typical class II AVO anomaly is seen along the test well from the cross-plot analysis and AVO attribute cube which indicates an oil filled reservoir.