BACKGROUND: The robotic surgical system overcomes many technological obstacles of conventional laparoscopic surgery, and possesses enormous clinical applied potential. The aim of this study was to compare the efficacy...BACKGROUND: The robotic surgical system overcomes many technological obstacles of conventional laparoscopic surgery, and possesses enormous clinical applied potential. The aim of this study was to compare the efficacy of Zeus robot-assisted laparoscopic cholecystectomy with conventional laparoscopic cholecystectomy. METHODS: Forty patients undergoing elective cholecystectomy were randomly divided into two groups. Patients in group A (n=20) underwent Zeus robot-assisted laparoscopic cholecystectomy, and patients in group B (n=20) received conventional laparoscopic cholecystectomy. The parameters on operative field, operative time, the number of actions, the rate of operative errors and minimal trauma were evaluated and compared between the two groups. RESULTS: The number of cleating camera (1.1±1.0 times) and the time of adjusting the operative field (2.2±0.7 minutes) in group A were significantly less than those (4.5±1.5 times) and (7.5±1.2 minutes) in group B. The number of dissection actions (337±86 times) and the rate of operative errors (10%) in group A were less than those (389±94 times), (25%) in group B. The total operation time (104.9±20.5 minutes) and setup time (29.5±9.8 minutes) in group A were significandy longer than those (78.6±17.1 minutes), (12.6±2.5 minutes) in group B. Blood loss and postoperative hospitalization were similar. No postoperative complications occurred in both groups, and open cholecystectomy was performed in each group. CONCLUSIONS: Zeus robot-assisted cholecystectomy inherits the benefits of minimally invasive surgery. The Zeus robotic surgical system is better than conventional laparoscopic technique in controlling the operative field and can be manipulated precisely and stablely though it requires more operative time.展开更多
AIM: To summarize the performing essentials and analyze the characteristics of remote Zeus robot-assisted laparoscopic cholecystectomy. METHODS: Robot-assisted laparoscopic cholecystectomy was performed in 40 patien...AIM: To summarize the performing essentials and analyze the characteristics of remote Zeus robot-assisted laparoscopic cholecystectomy. METHODS: Robot-assisted laparoscopic cholecystectomy was performed in 40 patients between May 2004 and July 2005. The operating procedures and a variety of clinical parameters were recorded and analyzed. RESULTS: Forty laparoscopic cholecystectomy procedures were successfully completed with Zeus robotic system. And there were no post-operative complications. Total operating time, system setup time and performing time were 100.3±18.5 min, 27.7±8.8 min and 65.6±18.3 min, respectively. The blood loss and postoperative hospital stay were 30.6±10.2 mL and 2.8±0.8 d, respectively. Camera clearing times and time used for operative field adjustment were 1.1±1.0 min and 2.0±0.8 rain, respectively. The operative error was 7.5%. CONCLUSION: Robot-assisted laparoscopic cholecystectomy following the principles of laparoscopic operation has specific performing essentials. It preserves the benefits of minimally invasive surgery and offers enhanced ability of controlling operation field, precise and stable operative manipulations.展开更多
RTS Zeus Ⅲ是新一代的紧凑型内部通话系统.并带有更多的配置选择Zeus Ⅲ提供32路的进/出通道以2路可配置的Partyline接口通道。它紧凑的尺寸很适合空间有限的环境。增加的以太网功能使Zeus Ⅲ可通过网络使用AZedit内部通话软件在任...RTS Zeus Ⅲ是新一代的紧凑型内部通话系统.并带有更多的配置选择Zeus Ⅲ提供32路的进/出通道以2路可配置的Partyline接口通道。它紧凑的尺寸很适合空间有限的环境。增加的以太网功能使Zeus Ⅲ可通过网络使用AZedit内部通话软件在任何地点来进行配置。Zeus Ⅲ可以直接通过前面板的USB接口或后面板的以太网接口连接到AZedit配置软件。展开更多
基金The study was supported by a grant from the Jie-Ping Wu Medical Foundation China (No. 2003-49-A).
文摘BACKGROUND: The robotic surgical system overcomes many technological obstacles of conventional laparoscopic surgery, and possesses enormous clinical applied potential. The aim of this study was to compare the efficacy of Zeus robot-assisted laparoscopic cholecystectomy with conventional laparoscopic cholecystectomy. METHODS: Forty patients undergoing elective cholecystectomy were randomly divided into two groups. Patients in group A (n=20) underwent Zeus robot-assisted laparoscopic cholecystectomy, and patients in group B (n=20) received conventional laparoscopic cholecystectomy. The parameters on operative field, operative time, the number of actions, the rate of operative errors and minimal trauma were evaluated and compared between the two groups. RESULTS: The number of cleating camera (1.1±1.0 times) and the time of adjusting the operative field (2.2±0.7 minutes) in group A were significantly less than those (4.5±1.5 times) and (7.5±1.2 minutes) in group B. The number of dissection actions (337±86 times) and the rate of operative errors (10%) in group A were less than those (389±94 times), (25%) in group B. The total operation time (104.9±20.5 minutes) and setup time (29.5±9.8 minutes) in group A were significandy longer than those (78.6±17.1 minutes), (12.6±2.5 minutes) in group B. Blood loss and postoperative hospitalization were similar. No postoperative complications occurred in both groups, and open cholecystectomy was performed in each group. CONCLUSIONS: Zeus robot-assisted cholecystectomy inherits the benefits of minimally invasive surgery. The Zeus robotic surgical system is better than conventional laparoscopic technique in controlling the operative field and can be manipulated precisely and stablely though it requires more operative time.
基金Supported by the Jieping Wu Medical Foundation, No.2003-49-A
文摘AIM: To summarize the performing essentials and analyze the characteristics of remote Zeus robot-assisted laparoscopic cholecystectomy. METHODS: Robot-assisted laparoscopic cholecystectomy was performed in 40 patients between May 2004 and July 2005. The operating procedures and a variety of clinical parameters were recorded and analyzed. RESULTS: Forty laparoscopic cholecystectomy procedures were successfully completed with Zeus robotic system. And there were no post-operative complications. Total operating time, system setup time and performing time were 100.3±18.5 min, 27.7±8.8 min and 65.6±18.3 min, respectively. The blood loss and postoperative hospital stay were 30.6±10.2 mL and 2.8±0.8 d, respectively. Camera clearing times and time used for operative field adjustment were 1.1±1.0 min and 2.0±0.8 rain, respectively. The operative error was 7.5%. CONCLUSION: Robot-assisted laparoscopic cholecystectomy following the principles of laparoscopic operation has specific performing essentials. It preserves the benefits of minimally invasive surgery and offers enhanced ability of controlling operation field, precise and stable operative manipulations.