In order to improve the lightning protection performance of transmission lines, lightning protection management has been divided into every tower that lightning protection performance has been evaluated respectively. ...In order to improve the lightning protection performance of transmission lines, lightning protection management has been divided into every tower that lightning protection performance has been evaluated respectively. According to factors such as landform, span, tower type, grounding resistance, isolator type, and so on, relative ratio of tripping operation of every tower in the line has been calculated to evaluate its lightning protection safety performance, it is beneficial to operation maintenance and lightning reconstruction of transmission lines.展开更多
Several large-scale wind turbine tripping accidents occurred in Jiuquan wind power base in 2011.According to the on-site survey and analysis of these accidents related to relay protection,causes were found to be the c...Several large-scale wind turbine tripping accidents occurred in Jiuquan wind power base in 2011.According to the on-site survey and analysis of these accidents related to relay protection,causes were found to be the collection system defects and low correct operation rate of small current grounded line selectors of the unearthed neutral point collection system.By referring to both the characteristics of Jiuquan wind power base and arrangement of relay protection,the short-circuit features of wind power and its impacts on relay protection are analyzed.The collection system and the retrofit of the small current grounded line selector are improved by specific countermeasures.Finally,further research subjects are put forward.展开更多
文摘In order to improve the lightning protection performance of transmission lines, lightning protection management has been divided into every tower that lightning protection performance has been evaluated respectively. According to factors such as landform, span, tower type, grounding resistance, isolator type, and so on, relative ratio of tripping operation of every tower in the line has been calculated to evaluate its lightning protection safety performance, it is beneficial to operation maintenance and lightning reconstruction of transmission lines.
基金supported by National High Technology Research and Development Program of China(863Program)(No.2011AA05A104)
文摘Several large-scale wind turbine tripping accidents occurred in Jiuquan wind power base in 2011.According to the on-site survey and analysis of these accidents related to relay protection,causes were found to be the collection system defects and low correct operation rate of small current grounded line selectors of the unearthed neutral point collection system.By referring to both the characteristics of Jiuquan wind power base and arrangement of relay protection,the short-circuit features of wind power and its impacts on relay protection are analyzed.The collection system and the retrofit of the small current grounded line selector are improved by specific countermeasures.Finally,further research subjects are put forward.