Nanocomposite Cr C/hydrogenated amorphous carbon(nc-CrC/a-C:H) coatings were deposited by a hybrid beams system comprised of a hollow cathode ion source and a cathodic arc ion-plating unit with varying H_2 flow rates....Nanocomposite Cr C/hydrogenated amorphous carbon(nc-CrC/a-C:H) coatings were deposited by a hybrid beams system comprised of a hollow cathode ion source and a cathodic arc ion-plating unit with varying H_2 flow rates. The influences of H_2 flow rates on the morphologies, microstructures, and properties of the coatings were systematically studied. The morphologies and microstructures of the coatings were characterized by SEM, AFM, XPS, Raman spectroscopy, GIXRD, and HRTEM. The mechanical and tribological properties were measured by a nano-indenter, scratch tester, and ball-ondisk tribometer. The wear tracks were evaluated using 3D profilometer, optical microscope, and EDS analysis. It has been found that a moderate H_2 flow rate can effectively smooth the surface, enlarge the fraction of a sp^3 bond, and improve the properties. The coating exhibits the highest hardness and elastic modulus at the H_2 flow rate of 40 sccm. A superior combination of adhesion strength,friction coefficient, and wear resistance can be achieved at the H_2 flow rate of 80 sccm.展开更多
Fe-based and Co-based cladding layers were prepared on the surface of AISI H13 hot die steel by laser cladding technology.The microstructure,hardness and abrasion resistance of the two cladding layers were studied by ...Fe-based and Co-based cladding layers were prepared on the surface of AISI H13 hot die steel by laser cladding technology.The microstructure,hardness and abrasion resistance of the two cladding layers were studied by means of optical microscope,scanning electron microscope,rockwell hardness tester,and high temperature friction and wear tester.Also,the red hardness of the cladding layers was measured,after holding the layers at 600℃ for 1 hour by muffle furnace and repeated 4 times.The rockwell hardness values of the substrate,the Fe-based and the Co-based alloy coating measured were HRC 47,HRC 52 and HRC 48,respectively.The red hardness values of the substrate and the Fe-based cladding layer were decreased,while that of the Co-based cladding layer was increased.The Co-based cladding layer has the minimal wear loss weight and friction coefficient among them.The wear mechanisms of the substrate,the Fe-based layer and the Cobased layer attribute mainly to abrasive wear,adhesion wear,and both of them,respectively.展开更多
The microstructures and properties of coating from cemented carbide on the substrate of H 13 by vacuum powder sintering were studied. The effect of sintering temperature on the microstructures of coating was discussed...The microstructures and properties of coating from cemented carbide on the substrate of H 13 by vacuum powder sintering were studied. The effect of sintering temperature on the microstructures of coating was discussed. The interface characteristics between coating and H 13 steel substrate, microhardness distribution and wear resistance in the coating were analyzed. The coating from cemented carbide with thickness of 1-3 mm by vacuum powder sintering at temperature ranging from 1280℃to 1300 ℃ was obtained. The experimental results indicated that the coating with microhardness of HV 1600 favorable to wear resistance is strongly bonded with the H 13 steel substrate by mutual diffusion and penetration of Fe,Cr, Mo,V in substrate towards the coating and W, Co,Ni in coating towards the substrate.展开更多
Fluorine-doped hydrogenated amorphous carbon (a-C:H:F) film was deposited on a flow-straightener, impeller and diffuser surface (SUS 304) of an enclosed-impeller type flow blood pump using the ionization deposition me...Fluorine-doped hydrogenated amorphous carbon (a-C:H:F) film was deposited on a flow-straightener, impeller and diffuser surface (SUS 304) of an enclosed-impeller type flow blood pump using the ionization deposition method with a source gas of C6F5H. The surface characteristics of the a-C:H:F film were examined using atomic force microscopy, X-ray photoelectron spectroscopy, and measurements of surface roughness, friction and surface potential. The a-C:H:F film tends to increase surface roughness and the negative surface charge. In addition, the surface energy and friction decrease with fluorine dopant in the a-C:H film. To estimate the hemolytic performance of a blood pump with the a-C:H:F film coating, the amount of hemolysis was measured using a mock circulatory system (in vitro test) with 500 mL of pig blood containing sodium citrate. In vitro test was conducted for 180 min with the blood flow and pump head maintained at 5 L/min and 100 mmHg, respectively. The a-C:H:F film coating reduced the amount of hemolysis and improved the hemolytic performance. Decreasing the surface energy and negative surface charge of the a-C:H:F film contributes to the improvement of the hemolytic performance. The a-C:H:F film coating is thus expected to be utilized in medical technology as a surface coating technology for artificial heart blood pumps.展开更多
The FEM model of TiBN and TiBN/TiN coated cutting tool in milling of H13 steel w as developed. Process variables such as temperature and stress in the coating l ayer as well as in the substrate were analyzed. The eff...The FEM model of TiBN and TiBN/TiN coated cutting tool in milling of H13 steel w as developed. Process variables such as temperature and stress in the coating l ayer as well as in the substrate were analyzed. The efficacy of the present FEM analysis was verified by conducting controlled milling experiments on AISI H13 t o collect the relevant tool life and force data.The results show that the stress in a coated tool can significantly be reduced compared to an uncoated cutting t ool,possibly due to surface coatings improving the tribological properties of cu tting tools.Coatings with good thermal properties also help to improve the therm al behavior of cutting tool.展开更多
Hydrogenated amorphous carbon coatings, deposited by low pressure plasma to minimize the wear of C100 steel components, were optimized and characterized. In order to ensure good adhesion of the films to the steel surf...Hydrogenated amorphous carbon coatings, deposited by low pressure plasma to minimize the wear of C100 steel components, were optimized and characterized. In order to ensure good adhesion of the films to the steel surface, a thin Ti interlayer was deposited, by magnetron sputtering, before the plasma deposition. The chemical characterization of the deposits was performed by means of RAMAN, XPS, RBS and ERDA analysis, while nanoindentation, nanoscratch and nanowear tests allowed to estimating the tribomechanical properties of the deposits, with the aim of evaluating their scuff-resistance. It was found that the optimized plasma deposited hydrogenated amorphous carbon coatings were well adherent to C100 steel and increased more than 70% its surface hardness.展开更多
Oxidation behaviors of TP304H steel with electrophoresis deposited CeO2 coating in water vapor were studied at 610℃~770℃ for 65 h. The results showed that CeO2 coating reduced effectively the oxidation rate of TP30...Oxidation behaviors of TP304H steel with electrophoresis deposited CeO2 coating in water vapor were studied at 610℃~770℃ for 65 h. The results showed that CeO2 coating reduced effectively the oxidation rate of TP304H. Analysis with SEM and EDS showed the structure of oxide scale turned from multi-layer to mono-layer and oxide scale with high Cr content formed on the surface of CeO2 coating while inner oxidation disappeared. Based on test results and CeO2characters that Ce ion can vary between Ce4+ and Ce3+ under oxygen-rich and oxygen-poor environment, it is concluded that CeO2 coating acts as a barrier to prevent oxygen inner diffusion and the partial oxygen pressure of CeO2 coating-substrate interface is limited. Cr first diffuses outward across CeO2 coating and forms oxide scale on the surface, which delays formation of Fe oxide.展开更多
基金supported by the National Natural Science Foundation of China(Nos.11275141 and 11175133)the International Cooperation Program of the Ministry of Science and Technology of China(No.2015DFR00720)+2 种基金the Center for Electron Microscopy of Wuhan Universitythe Center of Nanosci. and Nanotech,Research of Wuhan Universitythe Analysis and Test Center of Wuhan University
文摘Nanocomposite Cr C/hydrogenated amorphous carbon(nc-CrC/a-C:H) coatings were deposited by a hybrid beams system comprised of a hollow cathode ion source and a cathodic arc ion-plating unit with varying H_2 flow rates. The influences of H_2 flow rates on the morphologies, microstructures, and properties of the coatings were systematically studied. The morphologies and microstructures of the coatings were characterized by SEM, AFM, XPS, Raman spectroscopy, GIXRD, and HRTEM. The mechanical and tribological properties were measured by a nano-indenter, scratch tester, and ball-ondisk tribometer. The wear tracks were evaluated using 3D profilometer, optical microscope, and EDS analysis. It has been found that a moderate H_2 flow rate can effectively smooth the surface, enlarge the fraction of a sp^3 bond, and improve the properties. The coating exhibits the highest hardness and elastic modulus at the H_2 flow rate of 40 sccm. A superior combination of adhesion strength,friction coefficient, and wear resistance can be achieved at the H_2 flow rate of 80 sccm.
文摘Fe-based and Co-based cladding layers were prepared on the surface of AISI H13 hot die steel by laser cladding technology.The microstructure,hardness and abrasion resistance of the two cladding layers were studied by means of optical microscope,scanning electron microscope,rockwell hardness tester,and high temperature friction and wear tester.Also,the red hardness of the cladding layers was measured,after holding the layers at 600℃ for 1 hour by muffle furnace and repeated 4 times.The rockwell hardness values of the substrate,the Fe-based and the Co-based alloy coating measured were HRC 47,HRC 52 and HRC 48,respectively.The red hardness values of the substrate and the Fe-based cladding layer were decreased,while that of the Co-based cladding layer was increased.The Co-based cladding layer has the minimal wear loss weight and friction coefficient among them.The wear mechanisms of the substrate,the Fe-based layer and the Cobased layer attribute mainly to abrasive wear,adhesion wear,and both of them,respectively.
基金the National Natural Science Foundation of China(No.50175086,50335060)Ministry of Education(No.[2002]383)Hubei Provincial Department of Education(No.2004J002)
文摘The microstructures and properties of coating from cemented carbide on the substrate of H 13 by vacuum powder sintering were studied. The effect of sintering temperature on the microstructures of coating was discussed. The interface characteristics between coating and H 13 steel substrate, microhardness distribution and wear resistance in the coating were analyzed. The coating from cemented carbide with thickness of 1-3 mm by vacuum powder sintering at temperature ranging from 1280℃to 1300 ℃ was obtained. The experimental results indicated that the coating with microhardness of HV 1600 favorable to wear resistance is strongly bonded with the H 13 steel substrate by mutual diffusion and penetration of Fe,Cr, Mo,V in substrate towards the coating and W, Co,Ni in coating towards the substrate.
文摘Fluorine-doped hydrogenated amorphous carbon (a-C:H:F) film was deposited on a flow-straightener, impeller and diffuser surface (SUS 304) of an enclosed-impeller type flow blood pump using the ionization deposition method with a source gas of C6F5H. The surface characteristics of the a-C:H:F film were examined using atomic force microscopy, X-ray photoelectron spectroscopy, and measurements of surface roughness, friction and surface potential. The a-C:H:F film tends to increase surface roughness and the negative surface charge. In addition, the surface energy and friction decrease with fluorine dopant in the a-C:H film. To estimate the hemolytic performance of a blood pump with the a-C:H:F film coating, the amount of hemolysis was measured using a mock circulatory system (in vitro test) with 500 mL of pig blood containing sodium citrate. In vitro test was conducted for 180 min with the blood flow and pump head maintained at 5 L/min and 100 mmHg, respectively. The a-C:H:F film coating reduced the amount of hemolysis and improved the hemolytic performance. Decreasing the surface energy and negative surface charge of the a-C:H:F film contributes to the improvement of the hemolytic performance. The a-C:H:F film coating is thus expected to be utilized in medical technology as a surface coating technology for artificial heart blood pumps.
基金Funded by the National Natural Science Foundation of China (No.50465003) the Natural Science Foundation of Jiangxi Province (No.0350005) the State Key Laboratory Foundation of Die Technology at Huazhong University of Science and Technology (No.04 8)
文摘The FEM model of TiBN and TiBN/TiN coated cutting tool in milling of H13 steel w as developed. Process variables such as temperature and stress in the coating l ayer as well as in the substrate were analyzed. The efficacy of the present FEM analysis was verified by conducting controlled milling experiments on AISI H13 t o collect the relevant tool life and force data.The results show that the stress in a coated tool can significantly be reduced compared to an uncoated cutting t ool,possibly due to surface coatings improving the tribological properties of cu tting tools.Coatings with good thermal properties also help to improve the therm al behavior of cutting tool.
文摘Hydrogenated amorphous carbon coatings, deposited by low pressure plasma to minimize the wear of C100 steel components, were optimized and characterized. In order to ensure good adhesion of the films to the steel surface, a thin Ti interlayer was deposited, by magnetron sputtering, before the plasma deposition. The chemical characterization of the deposits was performed by means of RAMAN, XPS, RBS and ERDA analysis, while nanoindentation, nanoscratch and nanowear tests allowed to estimating the tribomechanical properties of the deposits, with the aim of evaluating their scuff-resistance. It was found that the optimized plasma deposited hydrogenated amorphous carbon coatings were well adherent to C100 steel and increased more than 70% its surface hardness.
文摘Oxidation behaviors of TP304H steel with electrophoresis deposited CeO2 coating in water vapor were studied at 610℃~770℃ for 65 h. The results showed that CeO2 coating reduced effectively the oxidation rate of TP304H. Analysis with SEM and EDS showed the structure of oxide scale turned from multi-layer to mono-layer and oxide scale with high Cr content formed on the surface of CeO2 coating while inner oxidation disappeared. Based on test results and CeO2characters that Ce ion can vary between Ce4+ and Ce3+ under oxygen-rich and oxygen-poor environment, it is concluded that CeO2 coating acts as a barrier to prevent oxygen inner diffusion and the partial oxygen pressure of CeO2 coating-substrate interface is limited. Cr first diffuses outward across CeO2 coating and forms oxide scale on the surface, which delays formation of Fe oxide.