AIM:To evaluate the efficacy of custom-made soft keratoconus(KC)lenses on corneal aberrations and photic phenomena in two different optical zones in patients with KC.METHODS:Sixty eyes of 42 patients with KC were exam...AIM:To evaluate the efficacy of custom-made soft keratoconus(KC)lenses on corneal aberrations and photic phenomena in two different optical zones in patients with KC.METHODS:Sixty eyes of 42 patients with KC were examined at baseline and after fitting HydroCone(Toris K)soft silicone hydrogel lenses.Best spectacle-corrected visual acuity(BSCVA)and contact lens-corrected visual acuity(CLCVA)were recorded.Lower-and higher-order corneal aberrations(LOAs and HOAs)were measured with and without Toris K lenses and compared in central 4.5 mm and 7 mm zones.Mesopic pupil diameter and subjective photic phenomena were also assessed.RESULTS:Mean CLCVA was significantly improved compared to BSCVA(P<0.0001).Corneal curvature and refractive measurements were found to be significantly reduced by the use of Toris K lenses,except for posterior corneal curvature values.In the 4.5 mm central optical zone,all wavefront aberrations decreased significantly after lens fitting(P<0.0001).In contrast,in the 7 mm(peripheral)optical zone,values for HOAs,spherical and residual aberrations,and optical path differences were increased,while LOAs,trefoil,and quadrifoil coefficients were decreased.The rate of photic phenomena was significantly higher in participants with a pupil size>6.00 mm(85.7%).CONCLUSION:Toris K lenses provide good visual results and a significant reduction in central corneal aberrations in patients with KC but could cause an increase in peripheral aberrations.This practical and nonsurgical approach appears to be an effective method for the visual management of KC.展开更多
AIM:To evaluate the effectiveness,safety,predictability,precision and changes of higher-order aberrations(HOAs)on corneal front surface of selective corneal wavefront aberration-guided femtosecond laser-assisted in si...AIM:To evaluate the effectiveness,safety,predictability,precision and changes of higher-order aberrations(HOAs)on corneal front surface of selective corneal wavefront aberration-guided femtosecond laser-assisted in situ keratomileusis(CW-FS-LASIK)in patients with high myopia 1-year postoperatively.METHODS:Totally 74 eyes of 37 patients with high myopia or myopic astigmatism in both the eyes who underwent the CW-FS-LASIK procedure in Xi’an Gaoxin Hospital from January 2021 to June 2021 were included.The changes of uncorrected distance visual acuity(UDVA),best corrected visual acuity(BCVA),spherical equivalent refraction(SER),astigmatism,HOAs and Strehl ratio(SR)on the anterior surface of the cornea after 1y of the surgery were analyzed.RESULTS:At postoperative 1y,the UDVA(logMAR)of 74 eyes(100%)reached 0 or better,including 0 in 8 eyes(10.81%),-0.1 in 45 eyes(60.81%),and-0.2 in 21 eyes(28.38%).The effectiveness index was 1.29±0.134.There was no decrease in postoperative BCVA compared with preoperative BCVA in all patients.Postoperative BCVA was the same in 44 eyes(59.46%)as preoperative BCVA,increased by 1 line in 23 eyes(31.08%)and increased by 2 lines in 7 eyes(9.46%)compared with preoperative BCVA.The safety index was 1.11±0.159.The estimated corrected SER before surgery was(-7.76±1.21)D,and the actual corrected SER was(-7.83±1.25)D(Y=0.9811X+0.2156,R2=0.9084).There was a high correlation between the estimated corrected SER and the actual corrected SER.The postoperative SER in 74 eyes(100%)was within±0.75 D.The postoperative astigmatism of all was within-0.75 D to 0.Root mean square(RMS)HOAs of spherical aberration and SR within 5 mm of the corneal front surface were all increased compared with those before operation(P<0.01).The total coma,horizontal coma and vertical coma were all decreased compared with those before operation(P<0.01).There was no statistically significant difference in horizontal trefoil and vertical trefoil compared with preoperative ones(P>0.05).CONCLUSION:Selective CW-FS-LASIK for correction of high myopia is effective,safe,predictive,and accurate.For patients with preoperative RMS HOAs over 0.25 defocus equivalent,postoperative coma aberration can be significantly reduced,and SR value can be increased,thus corneal imaging quality can be improved.展开更多
Strip-shaped chromatic aberration defects on the surface of an electro-galvanized fingerprint-resistant sheet were systematically studied using Thermo-Calc thermodynamic calculations,scanning electron microscope and X...Strip-shaped chromatic aberration defects on the surface of an electro-galvanized fingerprint-resistant sheet were systematically studied using Thermo-Calc thermodynamic calculations,scanning electron microscope and X-ray diffractometer analyses,and rapid heat treatment simulation technology.The formation mechanism of these defects was also analyzed.The results show a strong correlation between the defects and the uneven distribution of the Fe(001)component on the surface of the steel substrate.The relatively high proportion of Fe(001)components on the surface of the steel substrate affects the distribution density of the Zn crystal cells in different orientations during the electrodeposition process,which causes the reflection intensity of the light of the galvanized layer to differ from various visual perspectives,and macroscopic strip-shaped chromatic aberration defects are finally formed.The high proportion of the Fe(001)component on the surface of the steel substrate is mainly related to the following two factors.First,when the strip steel is hot-rolled,the finishing hot-rolling temperature is close to theγ→αphase transition temperature.When the local temperature on the upper surface of the strip steel is low,γ+αtwo-phase rolling easily occurs,and this results in an uneven stress distribution between theγandαphases after the hot-rolling process.This uneven distribution of hot-rolling stress results in the formation of a coarse grain structure in the local area on the surface of the hot-rolled sheet,which strongly affects the subsequent cold rolling and annealing process,and the annealed steel sheet substrate ultimately contains a greater proportion of the Fe(001)component.And second,a fast cooling rate(>10 K/s)during the slow cooling stage in the continuous annealing process inhibits the transformation of the Fe(001)to the Fe(111)component on the surface of the cold-rolled steel sheet,and it is then not possible to effectively eliminate the influence of the unevenly distributed Fe(001)component on the surface of the annealed steel sheet(originating from the uneven hot-rolled microstructure).This uneven distribution of the Fe(001)component on the surface of the annealed steel sheet following the continuous annealing heat treatment has a strong effect on the electrodeposition behavior of the Zn crystal cell in the subsequent electroplating process and the formation of macroscopic strip-shaped chromatic aberration defects on the surface of electro-galvanized fingerprint-resistant sheet.展开更多
离轴反射系统设计的关键环节是确定适用初始结构并进行优化,一般从同轴结构或者专利库中寻找相似的结构开始优化,这往往需要耗费大量的时间。以Seidel像差理论为依据,研究了一种获取离轴四反系统初始结构的设计方法。在设计之初引入视...离轴反射系统设计的关键环节是确定适用初始结构并进行优化,一般从同轴结构或者专利库中寻找相似的结构开始优化,这往往需要耗费大量的时间。以Seidel像差理论为依据,研究了一种获取离轴四反系统初始结构的设计方法。在设计之初引入视场偏置,通过追迹近轴光线给出五种单色像差的初级Seidel像差表示。以Seidel像差绝对值最小化作为目标函数,同时加入对光学和系统结构上的限制条件构建含有约束条件的单目标非线性优化模型,并通过粒子群优化算法进行求解。在此基础上,通过MATLAB调用CODE V API接口,判断此视场偏置情况下是否满足无遮拦的条件,并从中挑选出满足条件的初始结构。设计了一款焦距为1200 mm,视场1.2°×20°,F数为6的离轴四反光学系统,系统结构布局紧凑,成像质量良好,各项指标均满足设计要求。展开更多
文摘AIM:To evaluate the efficacy of custom-made soft keratoconus(KC)lenses on corneal aberrations and photic phenomena in two different optical zones in patients with KC.METHODS:Sixty eyes of 42 patients with KC were examined at baseline and after fitting HydroCone(Toris K)soft silicone hydrogel lenses.Best spectacle-corrected visual acuity(BSCVA)and contact lens-corrected visual acuity(CLCVA)were recorded.Lower-and higher-order corneal aberrations(LOAs and HOAs)were measured with and without Toris K lenses and compared in central 4.5 mm and 7 mm zones.Mesopic pupil diameter and subjective photic phenomena were also assessed.RESULTS:Mean CLCVA was significantly improved compared to BSCVA(P<0.0001).Corneal curvature and refractive measurements were found to be significantly reduced by the use of Toris K lenses,except for posterior corneal curvature values.In the 4.5 mm central optical zone,all wavefront aberrations decreased significantly after lens fitting(P<0.0001).In contrast,in the 7 mm(peripheral)optical zone,values for HOAs,spherical and residual aberrations,and optical path differences were increased,while LOAs,trefoil,and quadrifoil coefficients were decreased.The rate of photic phenomena was significantly higher in participants with a pupil size>6.00 mm(85.7%).CONCLUSION:Toris K lenses provide good visual results and a significant reduction in central corneal aberrations in patients with KC but could cause an increase in peripheral aberrations.This practical and nonsurgical approach appears to be an effective method for the visual management of KC.
文摘AIM:To evaluate the effectiveness,safety,predictability,precision and changes of higher-order aberrations(HOAs)on corneal front surface of selective corneal wavefront aberration-guided femtosecond laser-assisted in situ keratomileusis(CW-FS-LASIK)in patients with high myopia 1-year postoperatively.METHODS:Totally 74 eyes of 37 patients with high myopia or myopic astigmatism in both the eyes who underwent the CW-FS-LASIK procedure in Xi’an Gaoxin Hospital from January 2021 to June 2021 were included.The changes of uncorrected distance visual acuity(UDVA),best corrected visual acuity(BCVA),spherical equivalent refraction(SER),astigmatism,HOAs and Strehl ratio(SR)on the anterior surface of the cornea after 1y of the surgery were analyzed.RESULTS:At postoperative 1y,the UDVA(logMAR)of 74 eyes(100%)reached 0 or better,including 0 in 8 eyes(10.81%),-0.1 in 45 eyes(60.81%),and-0.2 in 21 eyes(28.38%).The effectiveness index was 1.29±0.134.There was no decrease in postoperative BCVA compared with preoperative BCVA in all patients.Postoperative BCVA was the same in 44 eyes(59.46%)as preoperative BCVA,increased by 1 line in 23 eyes(31.08%)and increased by 2 lines in 7 eyes(9.46%)compared with preoperative BCVA.The safety index was 1.11±0.159.The estimated corrected SER before surgery was(-7.76±1.21)D,and the actual corrected SER was(-7.83±1.25)D(Y=0.9811X+0.2156,R2=0.9084).There was a high correlation between the estimated corrected SER and the actual corrected SER.The postoperative SER in 74 eyes(100%)was within±0.75 D.The postoperative astigmatism of all was within-0.75 D to 0.Root mean square(RMS)HOAs of spherical aberration and SR within 5 mm of the corneal front surface were all increased compared with those before operation(P<0.01).The total coma,horizontal coma and vertical coma were all decreased compared with those before operation(P<0.01).There was no statistically significant difference in horizontal trefoil and vertical trefoil compared with preoperative ones(P>0.05).CONCLUSION:Selective CW-FS-LASIK for correction of high myopia is effective,safe,predictive,and accurate.For patients with preoperative RMS HOAs over 0.25 defocus equivalent,postoperative coma aberration can be significantly reduced,and SR value can be increased,thus corneal imaging quality can be improved.
文摘Strip-shaped chromatic aberration defects on the surface of an electro-galvanized fingerprint-resistant sheet were systematically studied using Thermo-Calc thermodynamic calculations,scanning electron microscope and X-ray diffractometer analyses,and rapid heat treatment simulation technology.The formation mechanism of these defects was also analyzed.The results show a strong correlation between the defects and the uneven distribution of the Fe(001)component on the surface of the steel substrate.The relatively high proportion of Fe(001)components on the surface of the steel substrate affects the distribution density of the Zn crystal cells in different orientations during the electrodeposition process,which causes the reflection intensity of the light of the galvanized layer to differ from various visual perspectives,and macroscopic strip-shaped chromatic aberration defects are finally formed.The high proportion of the Fe(001)component on the surface of the steel substrate is mainly related to the following two factors.First,when the strip steel is hot-rolled,the finishing hot-rolling temperature is close to theγ→αphase transition temperature.When the local temperature on the upper surface of the strip steel is low,γ+αtwo-phase rolling easily occurs,and this results in an uneven stress distribution between theγandαphases after the hot-rolling process.This uneven distribution of hot-rolling stress results in the formation of a coarse grain structure in the local area on the surface of the hot-rolled sheet,which strongly affects the subsequent cold rolling and annealing process,and the annealed steel sheet substrate ultimately contains a greater proportion of the Fe(001)component.And second,a fast cooling rate(>10 K/s)during the slow cooling stage in the continuous annealing process inhibits the transformation of the Fe(001)to the Fe(111)component on the surface of the cold-rolled steel sheet,and it is then not possible to effectively eliminate the influence of the unevenly distributed Fe(001)component on the surface of the annealed steel sheet(originating from the uneven hot-rolled microstructure).This uneven distribution of the Fe(001)component on the surface of the annealed steel sheet following the continuous annealing heat treatment has a strong effect on the electrodeposition behavior of the Zn crystal cell in the subsequent electroplating process and the formation of macroscopic strip-shaped chromatic aberration defects on the surface of electro-galvanized fingerprint-resistant sheet.
文摘离轴反射系统设计的关键环节是确定适用初始结构并进行优化,一般从同轴结构或者专利库中寻找相似的结构开始优化,这往往需要耗费大量的时间。以Seidel像差理论为依据,研究了一种获取离轴四反系统初始结构的设计方法。在设计之初引入视场偏置,通过追迹近轴光线给出五种单色像差的初级Seidel像差表示。以Seidel像差绝对值最小化作为目标函数,同时加入对光学和系统结构上的限制条件构建含有约束条件的单目标非线性优化模型,并通过粒子群优化算法进行求解。在此基础上,通过MATLAB调用CODE V API接口,判断此视场偏置情况下是否满足无遮拦的条件,并从中挑选出满足条件的初始结构。设计了一款焦距为1200 mm,视场1.2°×20°,F数为6的离轴四反光学系统,系统结构布局紧凑,成像质量良好,各项指标均满足设计要求。