[Objective] The study aimed to discuss the factors influencing the application of shaping biomass energy in the NHJHe absorption re- frigeration system. [ Method] In the NHJHe absorption refrigeration system, the ther...[Objective] The study aimed to discuss the factors influencing the application of shaping biomass energy in the NHJHe absorption re- frigeration system. [ Method] In the NHJHe absorption refrigeration system, the thermodynamic analysis of semi-gasification furnace based on sec- tional combustion technology and absorption refrigeration system was performed. [ Result] Biomass could burn cleanly and efficiently in the semi- gasification furnace, which can reduce the environmental pollution caused by the combustion of coal and other fossil fuels. The heating power of the furnace for the absorption refrigeration system could not be too high, so biomass energy and other low-grade energy can be used as heat sources, which opens up a new way for the utilization of biomass energy. [ Conclusion] Biomass energy was applied successfully in the absorption refrigera- tion system.展开更多
In this study, the first and second laws of thermodynamics are used to analyze the performance of a single-stage absorption refrigeration system powered by solar energy. The working pair used in this study is LiBr-H2O...In this study, the first and second laws of thermodynamics are used to analyze the performance of a single-stage absorption refrigeration system powered by solar energy. The working pair used in this study is LiBr-H2O where water (H2O) is the refrigerant and the lithium bromide (LiBr) is the absorbent. A mathematical model based on exergy analysis is applied to analyse the system performance. Temperature, enthalpy, entropy, mass flow rate and exergy loss of each component including evacuated tube solar collector are evaluated. Furthermore, the overall coefficient of performance (COPcooling) and the overall exergetic coefficient of performance (ECOPcooling) of the solar absorption system (absorption system coupled to an evacuated tube solar collector) for cooling purpose are calculated from the thermodynamic properties of the working fluids under weather conditions of Ngaoundere city, Cameroon. The calculations were done on the basis of a half hourly analysis from 6:30 AM to 6:30 PM. The results were compared and they show that the exergy destruction highly occurs in the generator and the solar collector. The simulation results can be used for the thermodynamics optimization of solar absorption refrigeration systems.展开更多
The utilization of sensible waste heat such as flue gas and industrial surplus heat is essential for energy saving. Supercritical CO2 power generation cycle is a promising way to be used in this field. In this paper, ...The utilization of sensible waste heat such as flue gas and industrial surplus heat is essential for energy saving. Supercritical CO2 power generation cycle is a promising way to be used in this field. In this paper, a new supercritical CO2 Rankine cycle coupled with an absorption refrigeration cycle is proposed, which consists of a reheating supercritical CO2 cycle, a mixed-effect Li Br-H2O absorption refrigeration cycle and solar subsystem including evacuated-tube collector and a hot water storage tank. The system has four variants according to the presence or absence of solar subsystem and net cooling energy output. The thermodynamic model of the proposed system was established and its performance was evaluated. The proposed system is able to realize cascade utilization of flue gas waste heat and efficient conversion of solar energy. It has much higher thermodynamic efficiency than the reference system(i.e., the conventional supercritical CO2 Brayton cycle). Taking combined power and cooling system driven by flue gas waste heat and solar energy as an example, its thermal efficiency and exergy efficiency are 20.37% and 54.18% respectively, compared with the 14.74% and 35.96% of the reference system. Energy Utilization Diagrams(EUD) are implemented to investigate the irreversible losses and variation of the exergy destruction in the energy conversion process. Parametric analysis in two key parameters is conducted to provide guidance for the system optimal design.展开更多
This research paper aims to perform dynamics analysis,3E assessment including energy,exergy,exergoeconomic,and the multiobjective evolutionary optimization on a novel solar Li-Br absorption refrigeration cycle.The res...This research paper aims to perform dynamics analysis,3E assessment including energy,exergy,exergoeconomic,and the multiobjective evolutionary optimization on a novel solar Li-Br absorption refrigeration cycle.The research is time-dependent,owing to solar radiation variability during different timelines.Theoretically,all the necessary thermodynamic,energy,and exergy equations are applied initially.This is followed by the thermoeconomic analysis,which takes place after defining the designing variables during the thermoeconomic optimization process and is presented together with the economic relations of the system and its thermoeconomic characteristics.Furthermore,the sensitivity analysis is undertaken,the source of system inefficiency is determined,the multi-objective evolutionary optimization of the whole system is carried out,and the optimal values are compared with the primary stage.Engineering Equation Solver(EES)software has been used to accomplish comprehensive analyses.As part of the validation process,the results of the research are compared with those published previously and are found to be relatively consistent.展开更多
Einstein cycle is a kind of single-pressure absorption refrigerator, using n-butane-ammonia-water as working fluids, driven by low grade heat source.The original cycle was improved, in which two solution heat exchange...Einstein cycle is a kind of single-pressure absorption refrigerator, using n-butane-ammonia-water as working fluids, driven by low grade heat source.The original cycle was improved, in which two solution heat exchangers were configured respectively before the generator and the evaporator to modify thermal performance of the refrigeration equipment.By using the exergy analysis method, the exergy losses of all thermal parts of the refrigerator were obtained, and the theoretical basis for improving design was given.The energy-saving places and the correlative further improvements were presented to minimize the exergy losses and optimize the whole refrigeration cycle.In addition, the generator and the condenser were the main parts where exergy losses existed.展开更多
基金Supported by Scientific and Technological Project of Educational Commission of Henan Province,China(2009B480006)
文摘[Objective] The study aimed to discuss the factors influencing the application of shaping biomass energy in the NHJHe absorption re- frigeration system. [ Method] In the NHJHe absorption refrigeration system, the thermodynamic analysis of semi-gasification furnace based on sec- tional combustion technology and absorption refrigeration system was performed. [ Result] Biomass could burn cleanly and efficiently in the semi- gasification furnace, which can reduce the environmental pollution caused by the combustion of coal and other fossil fuels. The heating power of the furnace for the absorption refrigeration system could not be too high, so biomass energy and other low-grade energy can be used as heat sources, which opens up a new way for the utilization of biomass energy. [ Conclusion] Biomass energy was applied successfully in the absorption refrigera- tion system.
文摘In this study, the first and second laws of thermodynamics are used to analyze the performance of a single-stage absorption refrigeration system powered by solar energy. The working pair used in this study is LiBr-H2O where water (H2O) is the refrigerant and the lithium bromide (LiBr) is the absorbent. A mathematical model based on exergy analysis is applied to analyse the system performance. Temperature, enthalpy, entropy, mass flow rate and exergy loss of each component including evacuated tube solar collector are evaluated. Furthermore, the overall coefficient of performance (COPcooling) and the overall exergetic coefficient of performance (ECOPcooling) of the solar absorption system (absorption system coupled to an evacuated tube solar collector) for cooling purpose are calculated from the thermodynamic properties of the working fluids under weather conditions of Ngaoundere city, Cameroon. The calculations were done on the basis of a half hourly analysis from 6:30 AM to 6:30 PM. The results were compared and they show that the exergy destruction highly occurs in the generator and the solar collector. The simulation results can be used for the thermodynamics optimization of solar absorption refrigeration systems.
基金support of the China Postdoctoral Science Foundation(No.2018M641288)the Science and Technology Project of China Electric Power Planning&Engineering Institute(No.K201730-X)。
文摘The utilization of sensible waste heat such as flue gas and industrial surplus heat is essential for energy saving. Supercritical CO2 power generation cycle is a promising way to be used in this field. In this paper, a new supercritical CO2 Rankine cycle coupled with an absorption refrigeration cycle is proposed, which consists of a reheating supercritical CO2 cycle, a mixed-effect Li Br-H2O absorption refrigeration cycle and solar subsystem including evacuated-tube collector and a hot water storage tank. The system has four variants according to the presence or absence of solar subsystem and net cooling energy output. The thermodynamic model of the proposed system was established and its performance was evaluated. The proposed system is able to realize cascade utilization of flue gas waste heat and efficient conversion of solar energy. It has much higher thermodynamic efficiency than the reference system(i.e., the conventional supercritical CO2 Brayton cycle). Taking combined power and cooling system driven by flue gas waste heat and solar energy as an example, its thermal efficiency and exergy efficiency are 20.37% and 54.18% respectively, compared with the 14.74% and 35.96% of the reference system. Energy Utilization Diagrams(EUD) are implemented to investigate the irreversible losses and variation of the exergy destruction in the energy conversion process. Parametric analysis in two key parameters is conducted to provide guidance for the system optimal design.
基金supported by the National Natural Science Foundation of China(Grant No.52176016)。
文摘This research paper aims to perform dynamics analysis,3E assessment including energy,exergy,exergoeconomic,and the multiobjective evolutionary optimization on a novel solar Li-Br absorption refrigeration cycle.The research is time-dependent,owing to solar radiation variability during different timelines.Theoretically,all the necessary thermodynamic,energy,and exergy equations are applied initially.This is followed by the thermoeconomic analysis,which takes place after defining the designing variables during the thermoeconomic optimization process and is presented together with the economic relations of the system and its thermoeconomic characteristics.Furthermore,the sensitivity analysis is undertaken,the source of system inefficiency is determined,the multi-objective evolutionary optimization of the whole system is carried out,and the optimal values are compared with the primary stage.Engineering Equation Solver(EES)software has been used to accomplish comprehensive analyses.As part of the validation process,the results of the research are compared with those published previously and are found to be relatively consistent.
文摘Einstein cycle is a kind of single-pressure absorption refrigerator, using n-butane-ammonia-water as working fluids, driven by low grade heat source.The original cycle was improved, in which two solution heat exchangers were configured respectively before the generator and the evaporator to modify thermal performance of the refrigeration equipment.By using the exergy analysis method, the exergy losses of all thermal parts of the refrigerator were obtained, and the theoretical basis for improving design was given.The energy-saving places and the correlative further improvements were presented to minimize the exergy losses and optimize the whole refrigeration cycle.In addition, the generator and the condenser were the main parts where exergy losses existed.