Accelerated Luminous Depreciation Testing for LED Lighting Products
1
作者 钱诚 孙博 曹峻松 《China Standardization》 2014年第5期74-79,共6页
With the application of energy-saving, environmental and durable LED lighting products, the reliability testing has become a pivot point for the large scale industrialization and popularization. The paper briefly intr... With the application of energy-saving, environmental and durable LED lighting products, the reliability testing has become a pivot point for the large scale industrialization and popularization. The paper briefly introduces two methods to be respectively applied in the accelerated depreciatinn lesting for the luminous flex of LED lighting products and the life of outdoor LED-driving power, which can sharply shorten the time for lifetime lest. providing references for the LED lighting products' reliability evaluation. 展开更多
关键词 LED lighting products outdoor LED driving power accelerated attenuation
下载PDF
Geometric effects resulting from the asymmetry of dipping fault:Hanging wall/ footwall effects
2
作者 王栋 谢礼立 胡进军 《Acta Seismologica Sinica(English Edition)》 CSCD 2008年第3期275-282,332,共9页
Root-mean-square distance Drms with characteristic of weighted-average is introduced in this article firstly. Drms can be used to capture the general proximity of a site to a dipping fault plane comparing with the rup... Root-mean-square distance Drms with characteristic of weighted-average is introduced in this article firstly. Drms can be used to capture the general proximity of a site to a dipping fault plane comparing with the rupture distance Drup and the seismogenic distance Dseis. Then, using Drup, Dseis and Drms, the hanging wall/footwall effects on the peak ground acceleration (PGA) during the 1999 Chi-Chi earthquake are evaluated by regression analysis. The logarithm residual shows that the PGA on hanging wall is much greater than that on footwall at the same Drup or Dseis when the Drup or Dseis is used as site-to-source distance measure. In contrast, there is no significant difference between the PGA on hanging wall and that on footwall at the same Drms when Drms is used. This result confirms that the hanging wall/footwall effect is mainly a geometric effect caused by the asymmetry of dipping fault. Therefore, the hanging wall/footwall effect on the near-fault ground motions can be ignored in the future attenuation analysis if the root-mean-square distance Drms is used as the site-to-source distance measure. 展开更多
关键词 root-mean-square distance rupture distance hanging wall/footwall effects peak acceleration attenuation relationship near-fault ground motion
下载PDF