A retrospective study of flow cytometric measurements on paraffin-embedded tumor specimens from 188 patients with bladder tumor was conducted. The results were analyzed in combination with the morphological variation ...A retrospective study of flow cytometric measurements on paraffin-embedded tumor specimens from 188 patients with bladder tumor was conducted. The results were analyzed in combination with the morphological variation of bladder tumors. It was found that the DNA ploid pottern, degree of infiltration and the multiplicity of bladder tumor were closely related with tumor recurrence, among which the DNA ploid pattern was most significant. In aneuploid bladder tumors the recurrent rate and mean annual recurrence frequency were 76.7% and 1.46, and those in the diploid bladder tumors were 18.7% and 0.33 respectively. Aneuploid was the most indicative parameter of the recurrence in bladder tumors. In addition, according to the DNA ploid pattern and DNA index (DI), the aneuploid tumors in our group were divided into 4 types, namely, tetraploid tumors, npn-euploid with DI(?)1.5, non-euploid tumors with DI>1.5 and two-aneuploid tumors. The results showed that the recurrent rate of tetraploid tumors was relatively lower and it became higher and higher in the following order: non-euploid tumors with DI(?)1.5, non-euploid tumors with DI>1.5, and two-aneuploid tumors. This indicates that there are different biological behaviors in tumors with different ploid pattern. Finally, the correlation between DNA ploid pattern and tumor metastasis was also discussed.展开更多
BACKGROUND: Recent researches demonstrate that onset of cerebral infarction always accompanies with obvious changes of function of thyroid axis; while, high-homocysteic acidemia has been proved as one of risk factors ...BACKGROUND: Recent researches demonstrate that onset of cerebral infarction always accompanies with obvious changes of function of thyroid axis; while, high-homocysteic acidemia has been proved as one of risk factors of vascular dementia and Alzheimer disease. Meanwhile, it is found that level of plasma homocysteic acid is positive correlation with injured degrees of cognitive function and brain damage. OBJECTIVE: To observe the changes of function of thyroid and level of homocysteic acid among patients with vascular dementia and compare with those patients without dementia cerebral infarction. DESIGN: Randomized grouping and contrast observation. SETTING: Department of Neurology, People’s Hospital Affiliated to Yunyang Medical College, South China Hospital of Wuhan University. PARTICIPANTS: A total of 38 patients with vascular dementia were hospitalized in the Department of Neurology, People’s Hospital Affiliated to Yunyang Medical College from February 2004 to December 2005. All patients met the diagnostic criteria of the Fourth Edition of Diagnostic and Statistical Manual of Mental Disorder (DSM-IV) established by American Psychiatric Association. Based on educational degrees, Mini-mental Status Examination (MMSE) was classified into illiteracy (≤ 17 points), education of primary school (educational duration ≤ 6 years, ≤ 24 points) and education of middle school or above (educational duration > 6 years, ≤ 24 points). Forty patients with non-dementia cerebral infarction were regarded as the control group and checked with CT examination. There were no significant differences of sex and age between the two groups. All patients and relatives were provided the consent. METHODS: Within 24 hours after hospitalization, patients with vascular dementia received MMSE scores, and the degrees were classified based on the scoring results: mild (20-24 points), moderate (10-19 points) and severe (below 10 points). Levels of thyroxine were measured with radioimmunodetection and content of homocysteic acid was measured with high performance liquid chromatogram (HPLC) electrochemical detection. MAIN OUTCOME MEASURES: Levels of homocysteic acid and thyroxine among patients with vascular dementia and non-dementia cerebral infarction. RESULTS: A total of 38 patients with vascular dementia and 40 patients with non-dementia cerebral infarction were involved in the final analysis. ① Levels of triiodothyronine (T3), thyroxine (T4) and free T3 (FT3) were (0.9±0.4) μg/L, (92.9±26.4) μg/L and (3.9±1.8) pmol/L in vascular dementia group respectively, which were higher than those in control group [(1.3±0.3) μg/L, (110.2±28.7) μg/L, (7.2±2.1) pmol/L, t =2.766 6-7.433 6, P < 0.01]; while, level of homocysteic acid was (29.57±7.12) μmol/L in vascular dementia group, which was higher than that in control group [(24.53±4.98) μmol/L, t =3.637 7, P < 0.01]. There were no significant differences of free T4 (FT4) and thyrotropic-stimulating hormone (TSH) between the two groups (P > 0.05). ② Levels of FT3 of patients with mild, moderate and severe vascular dementia were (1.0±0.2), (0.9±0.1) and (0.8±0.1) μg/L, respectively; levels of homocysteic acid were (26.52±4.84), (29.59±5.56) and (32.71±6.17) μmol/L, respectively. There were significant differences among patients at the three degrees of vascular dementia (F =3.59-32.4, P < 0.01). However, there were no significant differences of T4, FT4 and TSH among the three kinds of patients (P > 0.05). CONCLUSION: Levels of thyroxine of patients with vascular dementia decrease; however, levels of homocysteic acid increase. Therefore, the results can indirectly reflect severities of vascular dementia.展开更多
Nitro MAC(French acronym for continuous atmospheric measurements of nitrogenous compounds) is an instrument which has been developed for the semi-continuous measurement of atmospheric nitrous acid(HONO). This inst...Nitro MAC(French acronym for continuous atmospheric measurements of nitrogenous compounds) is an instrument which has been developed for the semi-continuous measurement of atmospheric nitrous acid(HONO). This instrument relies on wet chemical sampling and detection using high performance liquid chromatography(HPLC)-visible absorption at540 nm. Sampling proceeds by dissolution of gaseous HONO in a phosphate buffer solution followed by derivatization with sulfanilamide/N-(1-naphthyl)-ethylenediamine. The performance of this instrument was found to be as follows: a detection limit of around 3 ppt with measurement uncertainty of 10% over an analysis time of 10 min. Intercomparison was made between the instrument and a long-path absorption photometer(LOPAP) during two experiments in different environments. First, air was sampled in a smog chamber with concentrations up to 18 ppb of nitrous acid. Nitro MAC and LOPAP measurements showed very good agreement. Then, in a second experiment, ambient air with HONO concentrations below250 ppt was sampled. While Nitro MAC showed its capability of measuring HONO in moderate and highly polluted environments, the intercomparison results in ambient air highlighted that corrections must be made for minor interferences when low concentrations are measured.展开更多
In this work, nitric oxide (NO) release coatings designed for intravenous amperometric glucose sensors are optimized through the use ofa polylactic acid (PLA) layer doped with a lipophilic diazeniumdiolated specie...In this work, nitric oxide (NO) release coatings designed for intravenous amperometric glucose sensors are optimized through the use ofa polylactic acid (PLA) layer doped with a lipophilic diazeniumdiolated species that releases NO through a proton-driven mechanism. An Elast-Eon E2As polyurethane coating is used to both moderate NO release from the sensor surface and increase the sensor's linear detection range toward glucose. These sensors were evaluated for thromboresistance and in vivo glucose performance through implantation in rabbit veins. By maintaining NO flux on a similar scale to endogenous endothelial cells, implanted glucose sensors exhibited reduced surface clot formation which enables more accurate quantitative glucose measurements continuously. An in vivo time trace of implanted venous sensors demonstrated glucose values that correlated well with the discrete measurements of blood samples on a benchtop point-of-care sensor-based instrument. The raw measured currents from the implanted glucose sensors over 7 h time periods were converted to glucose concentration through use of both a one-point in vivo calibration and a calibration curve obtained in vitro within a bovine serum solution. Control sensors, assembled without NO release functionality, exhibit distinctive surface clotting over the 7 h in vivo implantation period.展开更多
文摘A retrospective study of flow cytometric measurements on paraffin-embedded tumor specimens from 188 patients with bladder tumor was conducted. The results were analyzed in combination with the morphological variation of bladder tumors. It was found that the DNA ploid pottern, degree of infiltration and the multiplicity of bladder tumor were closely related with tumor recurrence, among which the DNA ploid pattern was most significant. In aneuploid bladder tumors the recurrent rate and mean annual recurrence frequency were 76.7% and 1.46, and those in the diploid bladder tumors were 18.7% and 0.33 respectively. Aneuploid was the most indicative parameter of the recurrence in bladder tumors. In addition, according to the DNA ploid pattern and DNA index (DI), the aneuploid tumors in our group were divided into 4 types, namely, tetraploid tumors, npn-euploid with DI(?)1.5, non-euploid tumors with DI>1.5 and two-aneuploid tumors. The results showed that the recurrent rate of tetraploid tumors was relatively lower and it became higher and higher in the following order: non-euploid tumors with DI(?)1.5, non-euploid tumors with DI>1.5, and two-aneuploid tumors. This indicates that there are different biological behaviors in tumors with different ploid pattern. Finally, the correlation between DNA ploid pattern and tumor metastasis was also discussed.
文摘BACKGROUND: Recent researches demonstrate that onset of cerebral infarction always accompanies with obvious changes of function of thyroid axis; while, high-homocysteic acidemia has been proved as one of risk factors of vascular dementia and Alzheimer disease. Meanwhile, it is found that level of plasma homocysteic acid is positive correlation with injured degrees of cognitive function and brain damage. OBJECTIVE: To observe the changes of function of thyroid and level of homocysteic acid among patients with vascular dementia and compare with those patients without dementia cerebral infarction. DESIGN: Randomized grouping and contrast observation. SETTING: Department of Neurology, People’s Hospital Affiliated to Yunyang Medical College, South China Hospital of Wuhan University. PARTICIPANTS: A total of 38 patients with vascular dementia were hospitalized in the Department of Neurology, People’s Hospital Affiliated to Yunyang Medical College from February 2004 to December 2005. All patients met the diagnostic criteria of the Fourth Edition of Diagnostic and Statistical Manual of Mental Disorder (DSM-IV) established by American Psychiatric Association. Based on educational degrees, Mini-mental Status Examination (MMSE) was classified into illiteracy (≤ 17 points), education of primary school (educational duration ≤ 6 years, ≤ 24 points) and education of middle school or above (educational duration > 6 years, ≤ 24 points). Forty patients with non-dementia cerebral infarction were regarded as the control group and checked with CT examination. There were no significant differences of sex and age between the two groups. All patients and relatives were provided the consent. METHODS: Within 24 hours after hospitalization, patients with vascular dementia received MMSE scores, and the degrees were classified based on the scoring results: mild (20-24 points), moderate (10-19 points) and severe (below 10 points). Levels of thyroxine were measured with radioimmunodetection and content of homocysteic acid was measured with high performance liquid chromatogram (HPLC) electrochemical detection. MAIN OUTCOME MEASURES: Levels of homocysteic acid and thyroxine among patients with vascular dementia and non-dementia cerebral infarction. RESULTS: A total of 38 patients with vascular dementia and 40 patients with non-dementia cerebral infarction were involved in the final analysis. ① Levels of triiodothyronine (T3), thyroxine (T4) and free T3 (FT3) were (0.9±0.4) μg/L, (92.9±26.4) μg/L and (3.9±1.8) pmol/L in vascular dementia group respectively, which were higher than those in control group [(1.3±0.3) μg/L, (110.2±28.7) μg/L, (7.2±2.1) pmol/L, t =2.766 6-7.433 6, P < 0.01]; while, level of homocysteic acid was (29.57±7.12) μmol/L in vascular dementia group, which was higher than that in control group [(24.53±4.98) μmol/L, t =3.637 7, P < 0.01]. There were no significant differences of free T4 (FT4) and thyrotropic-stimulating hormone (TSH) between the two groups (P > 0.05). ② Levels of FT3 of patients with mild, moderate and severe vascular dementia were (1.0±0.2), (0.9±0.1) and (0.8±0.1) μg/L, respectively; levels of homocysteic acid were (26.52±4.84), (29.59±5.56) and (32.71±6.17) μmol/L, respectively. There were significant differences among patients at the three degrees of vascular dementia (F =3.59-32.4, P < 0.01). However, there were no significant differences of T4, FT4 and TSH among the three kinds of patients (P > 0.05). CONCLUSION: Levels of thyroxine of patients with vascular dementia decrease; however, levels of homocysteic acid increase. Therefore, the results can indirectly reflect severities of vascular dementia.
基金supported by EU Sixth Framework Programme (FP6) Eurochamp program (grant number 505968)EU Seventh Framework Programme (FP7) Eurochamp-2 program (grant number 228335)+2 种基金the NeoRad program from the French National Agency for Research (ANR-07-2/21-8908)the PhotoBat project from the Primequal program of the French Ministry of Environment (Primequal-project number 19599)the PhotoPaq LIFE + program (LIFE 08/ENV/F/000487 PHOTOPAQ)
文摘Nitro MAC(French acronym for continuous atmospheric measurements of nitrogenous compounds) is an instrument which has been developed for the semi-continuous measurement of atmospheric nitrous acid(HONO). This instrument relies on wet chemical sampling and detection using high performance liquid chromatography(HPLC)-visible absorption at540 nm. Sampling proceeds by dissolution of gaseous HONO in a phosphate buffer solution followed by derivatization with sulfanilamide/N-(1-naphthyl)-ethylenediamine. The performance of this instrument was found to be as follows: a detection limit of around 3 ppt with measurement uncertainty of 10% over an analysis time of 10 min. Intercomparison was made between the instrument and a long-path absorption photometer(LOPAP) during two experiments in different environments. First, air was sampled in a smog chamber with concentrations up to 18 ppb of nitrous acid. Nitro MAC and LOPAP measurements showed very good agreement. Then, in a second experiment, ambient air with HONO concentrations below250 ppt was sampled. While Nitro MAC showed its capability of measuring HONO in moderate and highly polluted environments, the intercomparison results in ambient air highlighted that corrections must be made for minor interferences when low concentrations are measured.
文摘In this work, nitric oxide (NO) release coatings designed for intravenous amperometric glucose sensors are optimized through the use ofa polylactic acid (PLA) layer doped with a lipophilic diazeniumdiolated species that releases NO through a proton-driven mechanism. An Elast-Eon E2As polyurethane coating is used to both moderate NO release from the sensor surface and increase the sensor's linear detection range toward glucose. These sensors were evaluated for thromboresistance and in vivo glucose performance through implantation in rabbit veins. By maintaining NO flux on a similar scale to endogenous endothelial cells, implanted glucose sensors exhibited reduced surface clot formation which enables more accurate quantitative glucose measurements continuously. An in vivo time trace of implanted venous sensors demonstrated glucose values that correlated well with the discrete measurements of blood samples on a benchtop point-of-care sensor-based instrument. The raw measured currents from the implanted glucose sensors over 7 h time periods were converted to glucose concentration through use of both a one-point in vivo calibration and a calibration curve obtained in vitro within a bovine serum solution. Control sensors, assembled without NO release functionality, exhibit distinctive surface clotting over the 7 h in vivo implantation period.