期刊文献+
共找到6,595篇文章
< 1 2 250 >
每页显示 20 50 100
“Titration”软件在分析化学教学中的应用 被引量:1
1
作者 余菁 屠婕红 《化学教育》 CAS 2000年第9期37-38,共2页
关键词 分析化学教学 titration 软件 酸碱滴定
下载PDF
Determination of aniline in environmental water samples by alternating-current oscillopolarographic titration 被引量:6
2
作者 Jun Ping Xiao Qing Xiang Zhou +2 位作者 Xiao Ke Tian Hua Hua Bai Xian Fa Su 《Chinese Chemical Letters》 SCIE CAS CSCD 2007年第6期730-733,共4页
A new method for the determination of aniline in environmental water based on oscillopolarographic titration was presented in this paper. Several factors including the kind, concentration, and volume of acid, the dosa... A new method for the determination of aniline in environmental water based on oscillopolarographic titration was presented in this paper. Several factors including the kind, concentration, and volume of acid, the dosage of potassium bromide, the temperature and concentration of concomitant substances were investigated in detail. The experimental results indicated that this method was simple, rapid, and sensitive. The linear range was 8.367 × 10(?4) to 2.789 × 10(?2) mol L(?1), the relative standard deviation (R.S.D.) was lower than 0.96%, and the spiked recoveries of aniline in environmental water samples were in the range of 99.4–106.9% under the optimal conditions. The results indicated that the present method could be used as an alternative method for aniline determination in realworld water samples. 展开更多
关键词 Alternating-current oscillopolarographic titration ANILINE Potassium bromide
下载PDF
Determination of pKa values of alendronate sodium in aqueous solution by piecewise linear regression based on acid-base potentiometric titration 被引量:2
3
作者 Jing Ke Hanfei Dou +3 位作者 Ximin Zhang Dushimabararezi Serge Uhagaze Xiali Ding Yuming Dong 《Journal of Pharmaceutical Analysis》 SCIE CAS 2016年第6期404-409,共6页
As a mono-sodium salt form of alendronic acid,alendronate sodium presents multi-level ionization for the dissociation of its four hydroxyl groups.The dissociation constants of alendronate sodium were determined in thi... As a mono-sodium salt form of alendronic acid,alendronate sodium presents multi-level ionization for the dissociation of its four hydroxyl groups.The dissociation constants of alendronate sodium were determined in this work by studying the piecewise linear relationship between volume of titrant and p H value based on acidbase potentiometric titration reaction.The distribution curves of alendronate sodium were drawn according to the determined p Ka values.There were 4 dissociation constants(pKa_1=2.43,pKa_2=7.55,pKa_3=10.80,pKa_4=11.99,respectively) of alendronate sodium,and 12 existing forms,of which 4 could be ignored,existing in different p H environments. 展开更多
关键词 Dissociation CONSTANTS ALENDRONATE SODIUM Distribution curve Piecewise linear regression ACID-BASE POTENTIOMETRIC titration
下载PDF
Study of Complexes of Lanthanum with Amino Acids by Titration Calorimeter 被引量:2
4
作者 Ye Gang, Wang Cun-xin, Qu Song-sheng College of Chemistry and Environment Science, Wuhan University, Wuhan 430072, China 《Wuhan University Journal of Natural Sciences》 EI CAS 2000年第4期479-484,共6页
The stability constants and thermodynamic functions for complexes of lanthanum with eight kind of amino acids according to 1∶1 and 1∶2 in proportion have been determined by titration calorimeter at 298.15 K. The ent... The stability constants and thermodynamic functions for complexes of lanthanum with eight kind of amino acids according to 1∶1 and 1∶2 in proportion have been determined by titration calorimeter at 298.15 K. The enthalpy change makes a predominant contribution to the stability of these complexes. The ring in amino acid associated with lanthanum ion helps to enhance the stability of complexes. Steric effects between rings in complexes leads to that the equilibrium constants of reaction of the complexes (1∶2) is much less than that of the complexes (1∶1). 展开更多
关键词 titration calorimeter rare earth amino acid COMPLEXES steric effects
下载PDF
POTENTIOMETRIC TITRATION OF CALCIUM IN SEAWATER 被引量:1
5
作者 谢式南 纪红 +1 位作者 吴爱琴 陈国华 《Chinese Journal of Oceanology and Limnology》 SCIE CAS CSCD 1997年第1期32-35,共4页
By using calcium ion selective elatrode (Ca ISE) as indicating electrode, saturated calomel electrode (SCE) as reference electrode and EGTA as titrant, calcium in seawater was determined by potentiometric titration in... By using calcium ion selective elatrode (Ca ISE) as indicating electrode, saturated calomel electrode (SCE) as reference electrode and EGTA as titrant, calcium in seawater was determined by potentiometric titration in borate buffer solution. This method can reduce observation errors in the determination of the endpoint, and thus provide better analytical precision(<0.08%) than present complexometric titration. 展开更多
关键词 CALCIUM ION SELECTIVE elatrode CALCIUM seawater POTENTIOMETRIC titration
下载PDF
Conductometric Titration for the Prediction of Conductivity in Solutions with Polymeric Membranes 被引量:1
6
作者 María José Lavorante Juan Isidro Franco 《Journal of Electronic Science and Technology》 CAS CSCD 2017年第4期342-350,共9页
The analytical technique of conductometric titration is used to characterize polymeric materials.This technique allows obtaining the polymer dry weight capacity(DWC) and the extent of reaction and establishing the opt... The analytical technique of conductometric titration is used to characterize polymeric materials.This technique allows obtaining the polymer dry weight capacity(DWC) and the extent of reaction and establishing the optimal number of water molecules per sulfonic groups.In this particular case the polymer material under study was Nafion?117.Two different reactions were made: Neutralization and exchange.Both of them allow obtaining the same result.Conductometric titrations could be considered as a good method to study the neutralization and exchange reactions for polymeric materials used in fuel cells or electrolyzers.The implementation of this analytical technique allows reducing operation time of those types of materials.The waiting time between determinations permits to say that the amount of reactant consumed and products obtained were the same after each addition of titrant. 展开更多
关键词 CONDUCTIVITY conductometric titration polymeric membranes
下载PDF
Extraction Mechanism of Rare Earths with Sec-Octylphenoxy Acetic Acid by Two-Phase Titration Technique 被引量:1
7
作者 乐善堂 廖伍平 +1 位作者 李德谦 苏锵 《Journal of Rare Earths》 SCIE EI CAS CSCD 2002年第5期416-419,共4页
The compositions of the extracted complexes of La, Gd, Er and Y with sec octyl phenoxy acetic acid in heptane and the related apparent extraction equilibrium constants K M were determined using two phase titration... The compositions of the extracted complexes of La, Gd, Er and Y with sec octyl phenoxy acetic acid in heptane and the related apparent extraction equilibrium constants K M were determined using two phase titration technique. The stoichiometric compounds for La, Gd, Er and Y should be LaA 3·2.5HA, GdA 3·3HA, ErA 3·3.1HA and YA 3·4.3HA respectively. And their p K M are 3.43, 3.46, 3.08 and 2.58 respectively. 展开更多
关键词 rare earths two phase titration sec octylphenoxy acetic acid EXTRACTION
下载PDF
Rapid determination of phenolic compounds in water samples by alternating-current oscillopolarographic titration 被引量:1
8
作者 XIAO Jun-ping WANG Xue-feng +4 位作者 ZHOU Qing-xiang FAN Xiao-yuan SU Xian-fa Bai Hua-hua DUAN Hai-jing 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2007年第5期622-627,共6页
A rapid, simple and sensitive method was demonstrated for the determination of phenolic compounds in water samples by alternating-current oscillopolarographic titration. With the presence of sulfuric acid, phenol coul... A rapid, simple and sensitive method was demonstrated for the determination of phenolic compounds in water samples by alternating-current oscillopolarographic titration. With the presence of sulfuric acid, phenol could be transferred into a nitroso-compound by reacting with NaNO2. The titration end-point was obtained by the formation of a sharp cut in the oscillopolarographic with infinitesimal NaNO2 on double platinum electrodes. The results showed that phenol had an excellent linear relationship over the range of 4.82×10^-6 -9.65×10^-3 mol/L, the RSD of the proposed method was lower than 1.5%, and the spiked recoveries of three real water samples were in the range of 95.6%-106.9%. 展开更多
关键词 alternating-current oscillopolarographic titration phenolic compounds
下载PDF
Pitfalls and Uncertainties of Using Potentiometric Titration for Estimation of Plant Roots Surface Charge and Acid-Base Properties 被引量:1
9
作者 Grzegorz Jozefaciuk Alicja Szatanik-Kloc +1 位作者 Malgorzata Lukowska Justyna Szerement 《American Journal of Plant Sciences》 2014年第13期1862-1876,共15页
Amount and properties of roots surface charge are important for nutrient uptake and balance in plants. Roots surface charge markedly varies at different rizosphere conditions (particularly pH and ionic strength), whic... Amount and properties of roots surface charge are important for nutrient uptake and balance in plants. Roots surface charge markedly varies at different rizosphere conditions (particularly pH and ionic strength), which can markedly alter during vegetation season. Among recently available measuring methods, surface charge-pH dependence of roots (as well as other biological objects) is most easily evaluated by potentiometric titration. Use of this method is also easy at different ionic strengths. Potentiometric titration also allows for estimation of the distribution of charge generating surface groups. However, many applications of this method seem to be based either on incorrect methodical or theoretical approaches. In this paper we discuss the methodical and theoretical backgrounds of the titration method. Basing on experimental titration curves of roots of barley grown in nutrient solution, we show inconsistency of surface charge results obtained at different measuring conditions. Limitations of theoretical interpretations of the results are outlined also. 展开更多
关键词 CHARGE Density DISSOCIATION Method Plant ROOT Surface titration
下载PDF
A Multiparameter Colloidal Titrations for the Determination of Cationic Polyelectrolytes 被引量:1
10
作者 Eduardo A. López Maldonado Adrián O. Terán Mercedes T. O. Guzmán 《Journal of Environmental Protection》 2012年第11期1559-1570,共12页
In water treatment processes and conditioning drinking water, PEs are widely used;however, their environmental impact is still doubtful, since residual concentrations increase organic matter content and represents a p... In water treatment processes and conditioning drinking water, PEs are widely used;however, their environmental impact is still doubtful, since residual concentrations increase organic matter content and represents a potential health hazard. This paper demonstrates a multiparametric study of two colloidal titration methods: spectrophotometric and zeta potential end point detection. The first one was optimized to guarantee the accuracy of cationic commercial PE quantification. It includes the indicator dose optimization using analytical criteria for competing equilibria, a calibration curve for two ranges of CPE concentration (1 - 5 ppm and 5 - 100 ppm) and the interference study of flocculant and Sn in the CPE quantification. The second method provides a physicochemical validation of the electric surface phenomena occurring during the colloidal titration and the end point detection. As an additional contribution the zeta potential titration was discussed and proposed as an alternative method for quantifying CPE when the sample is metal free. 展开更多
关键词 POLYELECTROLYTE Quantification COLLOIDAL titration ZETA Potential Polydadmac O-TOLUIDINE Blue Indicator Wastewater Treatment
下载PDF
Interaction of Ca^(2+) and soil humic acid characterized by a joint experimental platform of potentiometric titration, UV–visible spectroscopy, and fluorescence spectroscopy 被引量:1
11
作者 Haiming Tang Baohua Xiao Peiwen Xiao 《Acta Geochimica》 EI CAS CSCD 2021年第3期300-311,共12页
Rocky desertification has become a major environmental issue in the karst region of southwestern China.Karst rocky desertification was more severe in regions of limestone soil than in adjacent regions of other soils,d... Rocky desertification has become a major environmental issue in the karst region of southwestern China.Karst rocky desertification was more severe in regions of limestone soil than in adjacent regions of other soils,despite the relatively higher soil organic matter(SOM)content in limestone soil.The underlying mechanism remains ambiguous.We speculated that the geochemical characteristics of limestone soils in the karst region plays an essential role,especially the high calcium content of limestone soil.To test this hypothesis,we collected limestone soil samples from a limestone soil profile in the southwestern China karst region and extracted humic acid(HA)from these limestone soil samples.We investigated the interaction of Ca^(2+)and three HA samples on a joint experimental platform,which consists of an automatic potentiometric titrator,a UV–visible spectrometer,and a Fluorescence spectrometer.HA solutions were titrated by Ca^(2+)and optical spectra of the HA solutions were monitored during the titration experiments.The results indicated that:(1)the interaction of Ca^(2+)and HA is a combined process of adsorption and complexation.Adsorption dominated the overall distribution behavior of Ca^(2+),which could be fit by Langmuir and Freundlich isotherm models.Complexation was distinguished only when the concentration of Ca2+is low;(2)the changes of UV–visible spectroscopy and excitation–emission matrix fluorescencespectroscopy spectra of HA samples when they were binding with Ca^(2+)implied the apparent molecular size and structure of HA became larger and more complex;(3)the combination of Ca^(2+)and HA plays an important role in the SOM preservation of limestone soils but the stability of the Ca–HA association was relatively weak.The present study draws attention to maintaining the relatively higher Ca^(2+)concentration in limestone soils in ecologic restoration attempts in karst regions. 展开更多
关键词 Limestone soil Humic acid Calcium INTERACTION titration UV–Vis EEM
下载PDF
Preparation and Characterization of Cathode Materials La_(0.7)Sr_(0.3-x)Ca_xCo_(0.9)Fe_(0.1)O_(3-δ) by Reverse Titration Co-Precipitation Method for ITSOFC 被引量:1
12
作者 高文元 胡志强 +5 位作者 李长敏 唐乃岭 孙福禄 唐旭 魏蔷薇 孙永平 《Journal of Rare Earths》 SCIE EI CAS CSCD 2007年第S1期358-363,共6页
The precursors of La0.7Sr0.3-xCaxCo0.9Fe0.1O3-δ(LSCCF, x=0.05, 0.10, 0.15, 0.20) as the cathode materials for intermediate temperature solid oxide fuel cell (ITSOFC) were prepared by reverse titration co-precipitatio... The precursors of La0.7Sr0.3-xCaxCo0.9Fe0.1O3-δ(LSCCF, x=0.05, 0.10, 0.15, 0.20) as the cathode materials for intermediate temperature solid oxide fuel cell (ITSOFC) were prepared by reverse titration co-precipitation method with metal-nitrates as starting materials and mixed alkali (NaOH and Na2CO3) as a precipitating agent. The formation process of LSCCF from the precursors was monitored by TG-DSC, and the crystal structure and particles morphology of the precursors which were calcined at 600, 800, 1000 ℃ for 3 h were characterized using XRD, SEM technologies. Compared with the solid state reaction of constituent oxides, when the pH value of the precipitating solution was in the range of 9.1~9.5, the LSCCF powders from the precursors caclined at 800 ℃ for 3 h had high purity, homogeneous and single perovskite phase. The electrical conductivity of the LSCCF samples sintered at 1200 ℃ for 3 h, which was measured as a function of temperatures from 100 to 800 ℃ by DC four-probe method in air, decreased with x from 0.05 to 0.20. The value of electrical conductivity was almost equal because of Ca2+, Sr2+ co-dopant resulting in the 'mix effect' while x=0.10 or 0.15. The electrical conductivity of all doped samples was higher than 100 S·cm-1 at intermediate temperatures from 500 to 800 ℃, and there was good compatibility between the LSCCF cathode and Ce0.8Sm0.2O2 electrolyte. 展开更多
关键词 intermediate temperature solid oxide fuel cell La_(0.7)Sr_(0.3-x)Ca_xCo(1-y)Fe_yO_(3-δ) reverse titration co-precipitation property rare earths
下载PDF
Ultraviolet absorbance titration for the determination of conditional stability constants of Hg(Ⅱ) and dissolved organic matter 被引量:3
13
作者 BAI Yingchen WU Fengchang +3 位作者 WAN Guojing LIU Congqiang FU Pingqing LI Wen 《Chinese Journal Of Geochemistry》 EI CAS 2008年第1期46-52,共7页
Strong interaction between natural dissolved organic matter (DOM) and Hg(Ⅱ) may influence the trans- port, conversion, toxicity and bio-validity of mercury in the environment. In this paper ultraviolet (UV) absorbanc... Strong interaction between natural dissolved organic matter (DOM) and Hg(Ⅱ) may influence the trans- port, conversion, toxicity and bio-validity of mercury in the environment. In this paper ultraviolet (UV) absorbance titration was employed for the first time for the determination of the conditional stability constants of Hg(Ⅱ) and (DOM). With increasing Hg(Ⅱ) concentrations, the UV absorbance of fulvic acid, humic acid, and DOM in river increases progressively. By linear and non-linear model fitting, the conditional stability constants (lgK) of Hg(Ⅱ) and DOM were worked out to be 3.54?4.93 and 3.64?4.85, respectively. The results are consistent with those acquired by the typical fluorescence quenching titration method, with the maximum relative error of lgK being 2.6% and the average relative error being 0.2%. The UV absorbance titration method has the advantages of rapid determination, simple performance, and it will probably become a new approach to studying interactions between DOM and trace metallic ions. 展开更多
关键词 紫外线 稳定性 有机物
下载PDF
Modified Titration Intratympanic Gentamicin Injection for Unilateral Intractable Ménière's Disease 被引量:1
14
作者 刘波 冷杨名 +5 位作者 师洪 周任红 刘晶晶 张文娟 张甦琳 孔维佳 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2015年第5期747-751,共5页
This study looked into the efficacy of a modified titration protocol of intratympanic gentamicin injection(ITG) in the patients with unilateral intractable Ménière's disease(MD). Modified titration prot... This study looked into the efficacy of a modified titration protocol of intratympanic gentamicin injection(ITG) in the patients with unilateral intractable Ménière's disease(MD). Modified titration protocol of ITG at a low dose(20 mg/m L) was administered to 10 patients with definite unilateral intractable MD. After initial first two fixed ITGs on weekly basis,the patients might or might not be given any more injections,depending on the appearance of unilateral vestibular loss(UVL). ITG was terminated if the patients satisfied the criteria of UVL. All patients were followed-up for at least two years. The effects of ITG on the vertigo attack,functional level scores and postural balance were evaluated. Of the 10 cases,8 showed the sign of UVL after receiving initial two ITGs and were not given any more intratympanic injections,and the other 2 patients were administered three ITGs. A two-year follow-up revealed that complete and substantial vertigo control was achieved in 9 cases,and limited vertigo control in 1 patient. Hearing level was lowered in 2 patients. The posture stability and functional level scores were improved. Our study showed that the modified titration protocol of ITG at a low dose could effectively control vertigo in patients with unilateral intractable MD. 展开更多
关键词 vertigo intractable vestibular unilateral hearing ni re's Disease titration appearance auditory
下载PDF
Study and Application of a New On-Line Titration Technique
15
作者 朱建育 施利毅 《Journal of Shanghai University(English Edition)》 CAS 2002年第2期181-184,共4页
A new on line titration method and device based on a new technique continuous flow titration is described. By the means of electronically controlled switching of a solenoid valve, the main component of the system, t... A new on line titration method and device based on a new technique continuous flow titration is described. By the means of electronically controlled switching of a solenoid valve, the main component of the system, the equivalent point of the titration is easily determined. Several kinds of mixing tools were examined, whereby a self made mixing chamber with minimum volume gave best results and was therefore used in the device. The error of the titration is within 0.2% and the relative standard deviation (RSD) is below 1.2%. The results show no difference compared with a commercial device, meanwhile the new on line titration system is cheaper and fully automated and thus easy to hand and less solvent consumption. 展开更多
关键词 continuous flow titration on line system automated titration conductimetric detection.
下载PDF
Determination of Oxide in FLINAK Melt by Electrochemical Titration Technique
16
作者 王新东 段淑贞 +2 位作者 Christensen E. Von Barner J.H. Bjerrum N.J. 《Rare Metals》 SCIE EI CAS CSCD 1993年第2期97-102,共6页
The use of K2NbF7 as a probe solute for the cyclic voltammetric determination of oxide in FLINAK melts was studied and demonstrated. This method is based on a complex reaction and the peak current density of NbF72- re... The use of K2NbF7 as a probe solute for the cyclic voltammetric determination of oxide in FLINAK melts was studied and demonstrated. This method is based on a complex reaction and the peak current density of NbF72- reduction. The reaction constant was determined to be very large at 973 K. A cyclic voltammetric standard addition experiment was also employed to determine the amount of oxide in FLNAK melt. The oxide content of FLINAK melts is equal to the amount of Nb(V) added minus the amount of NbF72- which is obtained from the voltammogram. 展开更多
关键词 ELECTROCHEMISTRY Liquid metals NIOBIUM OXIDES titration
下载PDF
Determination the Hydrogen Stored in Carbon Nanotubes by NO Titration Method
17
作者 Shui Hua TANG Li Zhen GAO +4 位作者 Bao Chun LIU He LI Bo Lan ZHANG Liang Fu ZHANG Zuo Long YU 《Chinese Chemical Letters》 SCIE CAS CSCD 2001年第11期1015-1018,共4页
A novel method was established to determine the H-2-storage capacity in carbon nanotubes. According to 2NO+2H(2) (or 4H) = N-2+2H(2)O reaction, the H-2-storage capacity in carbon nanotubes could be calculated. The H-2... A novel method was established to determine the H-2-storage capacity in carbon nanotubes. According to 2NO+2H(2) (or 4H) = N-2+2H(2)O reaction, the H-2-storage capacity in carbon nanotubes could be calculated. The H-2-storage capacity in carbon nanotubes is at least 2.89 wt%. 展开更多
关键词 NO titration hydrogen storage carbon nanotubes
下载PDF
Determination of Poly(Diallyldimethylammonium Chloride)via Spectrophotometric Titration with Coomassie Brilliant Blue G Dye
18
作者 Alexander Shyichuk Dorota Ziókowska Jan Lamkiewicz 《光谱学与光谱分析》 SCIE EI CAS CSCD 北大核心 2016年第2期583-587,共5页
Poly(diallyldimethylammonium chloride)(PDDA)is used as organic coagulant in water purification and auxiliary agent in paper production.Determination of PDDA in aqueous solutions is carried out usually by means of poly... Poly(diallyldimethylammonium chloride)(PDDA)is used as organic coagulant in water purification and auxiliary agent in paper production.Determination of PDDA in aqueous solutions is carried out usually by means of polyelectrolyte titration using streaming current detector or o-Toluidine Blue dye for endpoint recognition.The proposed method of PDDA assay takes advantage of Coomassie Brilliant Blue G dye having strong affinity to cationic macromolecules.Titration of PDDA solution with the dye is carried out measuring absorbance at 585nm.Inflection points of the obtained zigzag photometric curves have good repeatability provided that titration rate is low enough to attain endpoint for 1hour or more.The method assures rectilinear calibration(R2=0.999 5)in the broad range of PDDA concentrations from 0.3to 9.6mg·dm^(-3). 展开更多
关键词 PDADMAC PolyDADMAC Cationic polyelectrolyte Colloid titration
下载PDF
Interaction between Heparin and Fibronectin: Using Quartz Crystal Microbalance with Dissipation, Immunochemistry and Isothermal Titration Calorimetry
19
作者 李贵才 WANG Caiping +2 位作者 杨苹 ZHOU Jie ZHU Pingchuan 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2015年第5期1074-1084,共11页
The adsorption behavior of heparin and fibronectin was studied by quartz crystal microbalance with dissipation(QCM-D), and the interaction between heparin and fibronectin was evaluated using immunochemistry and isothe... The adsorption behavior of heparin and fibronectin was studied by quartz crystal microbalance with dissipation(QCM-D), and the interaction between heparin and fibronectin was evaluated using immunochemistry and isothermal titration calorimetry(ITC) measurement. The results showed that there was competitive adsorption between heparin and fibronectin, and the preadsorption of fibronectin could prevent subsequent heparin adsorption to some extent, and the adsorbed Hep/Fn complex on the surface was in a rigid form. The bioactivity of heparin and fibronectin could be affected by the bulk concentration of each, and both heparin and fibronectin in Hep/Fn complex formed under p H 4 condition displayed larger bioactivity than that formed under p H 7 condition. Moreover, the fibronectin showed more exposed cell-binding sites at the p H value lower than physiological condition. The results of ITC further suggested that the interaction between heparin and fibronectin under p H 4 was stronger than under p H 7, and the complex was also more stable. The study brings forth the detailed interaction between heparin and fibronectin, which will be helpful for better understanding the interaction mechanism of the two biomolecules. The results may be potentially useful for the development of new generation of cardiovascular biomaterials. 展开更多
关键词 HEPARIN FIBRONECTIN QCM-D IMMUNOCHEMISTRY isothermal titration calorimetry
下载PDF
Application of Polyaniline Incorporated Carbon Particles Coated Platinum Electrode in Coulometric Titration to Determination of Polyisoprene Alcohol
20
作者 ZHAOGe LIUMeng +3 位作者 LIUKuai-zhi QUJiang-ying CHENGGang DUZu-ling 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2003年第4期390-394,共5页
The feasibility of using electrodes modified with polyaniline incorporated carbon particles films for improving the precision of coulometric titration is demonstrated. The problem of large deviation produced during de... The feasibility of using electrodes modified with polyaniline incorporated carbon particles films for improving the precision of coulometric titration is demonstrated. The problem of large deviation produced during determining polyisoprene by coulometric titration with direct titration technique(double Pt electrodes indicating electrode) has been solved. In the titration process, polyisoprene alcohol, an electro-inactive species, is adsorbed on the surface of the bare Pt electrode, which inhibits the electrode reaction of Br - and Br 2. Therefore, when the titration reaches the end-point, the detected current will slowly change with time, which can make the repeatability of end-point poor. The atomic force microscopic images show the morphology of the electrode surface of adsorbing polyisoprene alcohol. The application of the chemically modified electrode instead of the bare Pt electrode to indicating the end-point has been investigated. The results show that the Pt electrode coated with polyaniline incorporated carbon particles films is an excellent indicator electrode. This electrode has advantages that the indicating signals are sharp and repeatable at end-point. The precision and the accuracy of the determination of polyisoprene alcohol are satisfactory. 展开更多
关键词 Surface chemisorption PAn-CP CME Coulometric titration DETERMINATION
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部