A new method is described to measure the dynamic shear modulus of underwater acoustic structure materials in a small anechoic water tank by using a broadband parametric source, a precise coordinate installation and te...A new method is described to measure the dynamic shear modulus of underwater acoustic structure materials in a small anechoic water tank by using a broadband parametric source, a precise coordinate installation and techniques of signal processing in the frequency range of 20 kHz - 100 kHz. The typical size of material samples is 500×500 mm2. Basic principles, experiment installation and measured results are also presented展开更多
文摘A new method is described to measure the dynamic shear modulus of underwater acoustic structure materials in a small anechoic water tank by using a broadband parametric source, a precise coordinate installation and techniques of signal processing in the frequency range of 20 kHz - 100 kHz. The typical size of material samples is 500×500 mm2. Basic principles, experiment installation and measured results are also presented