期刊文献+
共找到56,435篇文章
< 1 2 250 >
每页显示 20 50 100
PREPARATION AND STUDY ON SILICONE ACRYLATE MICRO-EMULSION OF MULTIPOLYMER
1
作者 QINZonggen XIAZhengbin TUWeiping 《Chinese Journal of Reactive Polymers》 2004年第1期74-82,共9页
A silicone acrylate micro-emulsion of multipolymer was prepared by seed emulsion polymerization. The effects of polymerization process, emulsifier rate and amount, initiator rate and amount, polymerization temperature... A silicone acrylate micro-emulsion of multipolymer was prepared by seed emulsion polymerization. The effects of polymerization process, emulsifier rate and amount, initiator rate and amount, polymerization temperature, functional monomers, titration time on performances of emulsion have been discussed in detail. 展开更多
关键词 silicone silicone acrylate micro-emulsion Emulsion polymerization PREPARATION Study.
下载PDF
PREPARATION AND PROPERTIES OF SILICONE-ACRYLATE COPOLYMER LATEX
2
作者 杨慕杰 《Chinese Journal of Polymer Science》 SCIE CAS CSCD 2004年第3期215-218,共4页
Silicone-acrylate copolymer latex was prepared through three different polymerization processes, i.e., the batch process, preemulsified monomer addition and the monomer addition process. The results revealed that the ... Silicone-acrylate copolymer latex was prepared through three different polymerization processes, i.e., the batch process, preemulsified monomer addition and the monomer addition process. The results revealed that the monomer addition process is a desirable approach to produce narrow particle size distribution latex with higher polymerization conversion and less amount of coagulum. The effect of silicone content on the glossiness and water absorption of latex film was investigated and the results showed that the glossiness of latex film is improved up to a silicone content of 10% of total monomers, but becomes impaired thereafter, whereas water absorption is reduced accordingly. 展开更多
关键词 silicone-acrylate latex Polymerization conversion Latex film properties Water absorption
下载PDF
Damping properties of silicone rubber/polyacrylate sequential interpenetrating networks 被引量:3
3
作者 王雁冰 黄志雄 张联盟 《中国有色金属学会会刊:英文版》 CSCD 2006年第B02期517-520,共4页
Silicone rubber/polyacrylate sequential interpenetrating polymer networks(IPNs) were prepared by silicone rubber sheet dipped into the solution composed of different acrylate monomers and benzoyl peroxides(BPOs) for d... Silicone rubber/polyacrylate sequential interpenetrating polymer networks(IPNs) were prepared by silicone rubber sheet dipped into the solution composed of different acrylate monomers and benzoyl peroxides(BPOs) for different time at room temperature and then acrylate polymerized at 80℃for 2 h. The molecular structure and damping properties of sequential IPNs were studied by means of FT-IR and dynamic mechanical analysis(DMA), respectively. The FT-IR spectrum shows that polyacrylate distributes unevenly along the thickness direction of IPNs, i.e. the concentration of polyacrylate decreases from the midst to the surface of the IPNs. The DMA shows that cold crystallization of silicone in the temperature range from -47℃to -30℃is reduced and loss factor of IPNs is improved after interpenetrating with polyacrylate. This suggestes that IPNs can be used as damping materials. 展开更多
关键词 硅橡胶/聚丙烯酸酯 顺序互穿网络 阻尼性质 减振作用
下载PDF
Silicone oil as a corneal lubricant to reduce corneal edema and improve visualization during 被引量:1
4
作者 Dan-Yang Che Zhu-Lin Chan +1 位作者 Ji-Bo Zhou Dong-Qing Zhu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第1期92-96,共5页
AIM:To evaluate the efficacy and safety of silicone oil(SO)as a corneal lubricant to improve visualization during vitrectomy.METHODS:Patients who underwent vitreoretinal surgery were divided into two groups.Group 1 wa... AIM:To evaluate the efficacy and safety of silicone oil(SO)as a corneal lubricant to improve visualization during vitrectomy.METHODS:Patients who underwent vitreoretinal surgery were divided into two groups.Group 1 was operated on with initial SO(Oxane 5700)as a corneal lubricant.Group 2 was operated on with initial lactated ringer’s solution(LRS)and then replaced with SO as required.Fundus clarity was scored during the surgery.Fluorescein staining was performed to determine the damage to corneal epithelium.RESULTS:Totally 114 eyes of 114 patients were included.Single SO use maintained a clear cornea and provided excellent visualization of surgical image.In group 1,the fundus clarity was grade 3 in 41/45 eyes and grade 2 in 4/45 eyes.In group 2,corneal edema frequently occurred after initial LRS use.The fundus clarity was grade 3 in 19/69 eyes,2 in 37/69 eyes and 1 in 13/69 eyes(P<0.05).SO was applied in 29 eyes of initial LRS use with subsequent corneal edema,which eliminated the corneal edema in 26 eyes.Corneal fluorescein staining score in group 1 was 0 in 28 eyes,1 in 11 eyes and 2 in 6 eyes,and 40,20 and 9,respectively,in group 2(all P>0.05).CONCLUSION:The use of SO as a corneal lubricant is effective and safe for preserving and improving corneal clarity and providing clear surgical field during vitrectomy. 展开更多
关键词 silicone oil corneal lubricant corneal edema VITRECTOMY
下载PDF
The Various Complications Associated with Use of Silicone Oil in Rhegmatogenous Retinal Detachment (RRD) Surgery via Three-Port Vitrectomy (3PV): A Retrospective Study at the Ophthalmology Center of Abass Ndao Hospital
5
作者 Soda Mbaye El Hadji Malick Sy +1 位作者 Aïssatou Aw Papa Amadou Ndiaye 《Open Journal of Ophthalmology》 2024年第3期250-256,共7页
Introduction: RRD (Rhegmatogenous Retinal Detachment) is a separation between the neuroepithelium and the pigment epithelium due to the passage of fluid through a retinal dehiscence. It constitutes a major ophthalmolo... Introduction: RRD (Rhegmatogenous Retinal Detachment) is a separation between the neuroepithelium and the pigment epithelium due to the passage of fluid through a retinal dehiscence. It constitutes a major ophthalmologic emergency. Its management is primarily surgical, either through external or internal approaches, with tamponade using gas or silicone oil. The purpose of this study was to report the various complications associated with the use of silicone oil in vitreoretinal surgery. Patients et methods: We conducted a retrospective, descriptive, and analytical study from October 1, 2020, to October 31, 2023, which included all patients who underwent surgery for RRD using three-port vitrectomy (3PV) with tamponade using 1000 centistoke silicone oil (Group 1) and 5000 centistoke silicone oil (Group 2). All patients underwent a complete ophthalmologic examination and were operated on by the same surgeon. Data analysis was performed using Excel software. Results: Overall, 31 patient files representing 33 eyes were collected, with a mean age of 48.83 years and a sex ratio of 4.16. Group 1 consisted of 16 eyes (48.48%), and Group 2 consisted of 17 eyes (51.51%). The different complications observed were cataracts in all phakic subjects, accounting for 57.57%;ocular hypertonia in 69.69% (27.27% in Group 1;42.42% in Group 2);anterior chamber silicone oil migration in 24.24% (9.09% in Group 1;15.15% in Group 2);recurrence of retinal detachment in 21.21% (6.06% in Group 1;15.15% in Group 2);and silicone oil emulsification in 24.24% (15.15% in Group 1;9.09% in Group 2). Additionally, there was one case of corneal degeneration in Group 1. Conclusion: Silicone oil is an effective tamponade agent used in the treatment of retinal detachments. Close patient follow-up is necessary due to the complications associated with its use, which can occur either early or late after surgery. 展开更多
关键词 silicone CATARACTS OHT Emulsifications
下载PDF
Non-contact wide-field viewing system-assisted scleral buckling surgery for retinal detachment in silicone oilfilled eyes
6
作者 Su-Lan Wu Yi-Qi Chen +7 位作者 Li-Jun Shen Jian-Bo Mao Li Lin Ji-Wei Tao Huan Chen Shi-An Zhang Jia-Feng Yu Chen-Xi Wang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第4期761-766,共6页
AIM:To evaluate scleral buckling(SB)surgery using a noncontact wide-field viewing system and 23-gauge intraocular illumination for the treatment of rhegmatogenous retinal detachment in silicone oil(SO)-filled eyes.MET... AIM:To evaluate scleral buckling(SB)surgery using a noncontact wide-field viewing system and 23-gauge intraocular illumination for the treatment of rhegmatogenous retinal detachment in silicone oil(SO)-filled eyes.METHODS:Totally 9 patients(9 eyes)with retinal detachment in SO-filled eyes were retrospectively analyzed.All patients underwent non-contact wide-field viewing system-assisted buckling surgery with 23-gauge intraocular illumination.SO was removed at an appropriate time based on recovery.The patients were followed up for at least 3mo after SO removal.Retinal reattachment,complications,visual acuity and intraocular pressure(IOP)before and after surgery were observed.RESULTS:Patients were followed up for a mean of 8.22mo(3-22mo)after SO removal.All patients had retinal reattachment.At the final follow-up,visual acuity showed improvement for 8 patients,and no change for 1 patient.The IOP was high in 3 patients before surgery,but it stabilized after treatment;it was not affected in the other patients.None of the patients had infections,hemorrhage,anterior ischemia,or any other complication.CONCLUSION:This new non-contact wide-field viewing system-assisted SB surgery with 23-gauge intraocular illumination is effective and safe for retinal detachment in SO-filled eyes. 展开更多
关键词 non-contact wide-field viewing system scleral buckling silicone oil-filled retinal detachment
下载PDF
Silicone oil migrating into the conjunctival space and orbit after surgery for an eye-penetrating injury:A case report
7
作者 Ben-Liang Shu Hong-Yun Wu +4 位作者 Yu-Xiang Hu Jie Rao Bin Wei Qin-Yi Huang Xiao-Rong Wu 《World Journal of Clinical Cases》 SCIE 2024年第19期3950-3955,共6页
BACKGROUND We report a case of eye-penetrating injury in which a massive silicone oil migration into the patient’s subconjunctival space and orbit occurred after vitrectomy.CASE SUMMARY A 30-year-old male patient sou... BACKGROUND We report a case of eye-penetrating injury in which a massive silicone oil migration into the patient’s subconjunctival space and orbit occurred after vitrectomy.CASE SUMMARY A 30-year-old male patient sought medical attention at Ganzhou People’s Hospital after experiencing pain and vision loss in his left eye due to a nail wound on December 9,2023.Diagnosis of penetrating injury caused by magnetic foreign body retention in the left eye and hospitalization for treatment.On December 9,2023,pars plana vitrectomy was performed on the left eye for intraocular foreign body removal,abnormal crystal extraction,retinal photocoagulation.Owing to the discovery of retinal detachment at the posterior pole during surgery,silicone oil was injected to fill the vitreous body,following which upper conjunctival bubble-like swelling was observed.Postoperative orbital computed tomography(CT)review indicated migration of silicone oil to the subconjunctival space and orbit through a self-permeable outlet.On December 18,2023,the patient sought treatment at the First Affiliated Hospital of Nanchang University,China.The patient presented with a pronounced foreign body sensation following left eye surgery.On December 20,2023,the foreign body was removed from the left eye frame and an intraocular examination was conducted.The posterior scleral tear had closed,leading to termination of the surgical procedure following supplementary laser treatment around the tear.The patient reported a significant reduction in ocular surface symptoms just one day after surgery.Furthermore,a notable decrease in the migration of silicone oil was observed in orbital CT scans.CONCLUSION The timing of silicone oil injection for an eye-penetrating injury should be carefully evaluated to avoid the possibility of silicone oil migration. 展开更多
关键词 silicone oils MIGRATION VITRECTOMY Eye injuries PENETRATING Case report
下载PDF
Endophthalmitis in silicone oil-filled eye: A case report
8
作者 Hui-Chao Yan Ze-Lu Wang +5 位作者 Wen-Zhen Yu Ming-Wei Zhao Jian-Hong Liang Hong Yin Xuan Shi Heng Miao 《World Journal of Clinical Cases》 SCIE 2024年第1期163-168,共6页
BACKGROUND Endophthalmitis occurring in silicone oil-filled eyes is a very rare occurrence,with reported incidence rates ranging between 0.07%and 0.039%.Traditional methods of management of infectious endophthalmitis ... BACKGROUND Endophthalmitis occurring in silicone oil-filled eyes is a very rare occurrence,with reported incidence rates ranging between 0.07%and 0.039%.Traditional methods of management of infectious endophthalmitis include the removal of silicone oil,washout of the vitreous cavity,administration of intravitreal antibiotics,and reinjection of silicone oil.CASE SUMMARY Herein,we report the case of a 39-year-old man with unilateral endophthalmitis after pars plana vitrectomy and silicone oil tamponade.Intravitreal injections of full-dose antibiotics and anterior chamber washout were used to treat the patient.No signs of retinal toxicity were observed during the follow-up period.CONCLUSION Intravitreal full-dose antibiotic injections and anterior chamber washout are promising alternatives to traditional therapies for endophthalmitis in silicone oilfilled eyes. 展开更多
关键词 ENDOPHTHALMITIS Intravitreal injection silicone oil-filled eye Pars plana vitrectomy WASHOUT Case report
下载PDF
Research Progress of Carbon-Silicone Composite Materials
9
作者 Beibei Liu Rongjie Kan 《Expert Review of Chinese Chemical》 2024年第2期1-7,共7页
Silicone is a kind of polymer material with high cross-linked structure,which is com-posed by Si-O-Si main chain.Due to the special molecular chain structure,silicone mate-rials are characterized by oxidation resistan... Silicone is a kind of polymer material with high cross-linked structure,which is com-posed by Si-O-Si main chain.Due to the special molecular chain structure,silicone mate-rials are characterized by oxidation resistance,aging resistance,high and low temperature resistance and chemical corrosion resistance.Moreover,silicone materials have process-able properties,simple forming process,good mechanical property,non-toxic and pollution-free.Therefore,silicone has been widely concerned by researchers at home and abroad.In this paper,the main research progress and application directions of carbon-silicone composite at home and abroad in recent years are reviewed. 展开更多
关键词 carbon materials GRAPHEME silicone composite materials
下载PDF
乳腺假体并发症的Silicone序列MRI特征 被引量:3
10
作者 陈竹碧 刘天然 +1 位作者 左稳 韩文彬 《海南医学》 CAS 2016年第8期1275-1277,共3页
目的分析乳腺假体植入术后并发症的MRI表现,探讨其诊断价值。方法回顾性分析本院2013年6月至2015年6月收治的9例乳腺假体MRI特征。结果 1假体退行性样改变:Silicone-Sup序列上表现为片状不规则混杂信号或气泡样无信号结节。2假体包膜挛... 目的分析乳腺假体植入术后并发症的MRI表现,探讨其诊断价值。方法回顾性分析本院2013年6月至2015年6月收治的9例乳腺假体MRI特征。结果 1假体退行性样改变:Silicone-Sup序列上表现为片状不规则混杂信号或气泡样无信号结节。2假体包膜挛缩、假体变形移位:表现为假体边缘呈波浪状,囊壁增厚。3假体破裂(分囊内破裂和包膜破裂):囊内破裂Silicone-only序列表现囊内曲线状、弧线状低信号;包膜破裂表现为假体包膜连续性中断、假体周围间隙内存在结节状或片状假体信号。结论 MRI是诊断乳腺假体并发症的首选方法,视野全面,无需压迫,诊断准确率高。 展开更多
关键词 乳腺假体 silicone序列 并发症 磁共振成像 诊断价值
下载PDF
Synthesis and properties of UV curable polyurethane acrylates based on two different hydroxyethyl acrylates 被引量:10
11
作者 廖峰 曾幸荣 +2 位作者 李红强 赖学军 赵富春 《Journal of Central South University》 SCIE EI CAS 2012年第4期911-917,共7页
Two kinds of UV curable polyurethane acrylate oligomers (PUPA and PUCA) were synthesized via the addition reaction between isophorone diisocyanate (IPDI) and polyethylene glycol monoacrylate (PEA6) or polycaprol... Two kinds of UV curable polyurethane acrylate oligomers (PUPA and PUCA) were synthesized via the addition reaction between isophorone diisocyanate (IPDI) and polyethylene glycol monoacrylate (PEA6) or polycaprolactone modified hydroxyethyl acrylate (PCLA2). The structures of PUPA and PUCA were characterized by Fourier transform infrared spectroscopy (FT-IR), IH nuclear magnetic resonance (^H NMR), gel permeation chromatography (GPC) and differential scanning calorimeter (DSC), and the thermal stability and dynamic mechanical thermal properties of their cured films were measured by thermogravimetric analysis (TGA) and dynamic mechanical analysis (DMA), respectively. The viscosity of the oligomers and mechanical properties of the cured films were also studied. The results show that both oligomers have narrow molecular weight distribution. The viscosity of PUPA is 2.310 Pa.s at 25 ℃, while that of PUCA is: up to 3.980 Pa-s. The UV cured PUPA and PUCA films have homogeneous phase structure, and the PUCA film shows higher glass transition temperature and storage modulus. Furthermore, the PUCA film possesses better mechanical properties than PUPA, while the latter shows better alkali resistance. 展开更多
关键词 UV curable oligomer isophorone diisocyanate polyurethane acrylate hydroxyethyl acrylate
下载PDF
Comparison of Densiron 68 and 1 000 cSt silicone oil in the management of rhegmatogenous retinal detachment with inferior breaks 被引量:4
12
作者 Ibrahim Kocak Haci Koc 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2013年第1期81-84,共4页
AIM:To compare success rates and complications of Densiron 68 and 1000cSt silicone oil (SO) in the management of rhegmatogenous retinal detachment (RRD) with inferior breaks (IBs). METHODS:Totally 61 eyes of 61 consec... AIM:To compare success rates and complications of Densiron 68 and 1000cSt silicone oil (SO) in the management of rhegmatogenous retinal detachment (RRD) with inferior breaks (IBs). METHODS:Totally 61 eyes of 61 consecutive patients with RRD with IBs were assigned to pars plana vitrectomy (PPV) with Densiron (n =31) or PPV with SO (n=30) in order of presentation. SO and Densiron removal was performed 3 months after initial surgery. Follow up visits were terminated 6 months after SO removal. ·RESULTS:With a single operation, the Densiron group showed 84% and SO 74% reattachment. With further surgery, both groups showed 90% reattachment. Complications such as cataract, raised intraocular pressure (IOP), inflammatory reaction, macular epiretinal membranes, and emulsification of SO were seen in both groups. CONCLUSION:Densiron and SO are found to have similar success rates and complications. 展开更多
关键词 retinal detachment silicone oil Densiron heavy silicone oil inferior break
下载PDF
UV-curing of hyperbranched polyurethane acrylate-polyurethane diacrylate/SiO_2 dispersion and TGA/FTIR study of cured films 被引量:11
13
作者 GAO Qiong-zhi LI Hong-qiang ZENG Xing-rong 《Journal of Central South University》 SCIE EI CAS 2012年第1期63-70,共8页
UV-curable hyperbranched polyurethane acrylate-polyurethane diacrylate/SiO2 dispersion (HBPUA-PUDA/SiO2) was prepared with isophorone diisocyanate (IPDI), hyperbranched polyester Boltorn H20 (H20), hydroxy-ethyl... UV-curable hyperbranched polyurethane acrylate-polyurethane diacrylate/SiO2 dispersion (HBPUA-PUDA/SiO2) was prepared with isophorone diisocyanate (IPDI), hyperbranched polyester Boltorn H20 (H20), hydroxy-ethyl acrylate (HEA), polyethyleneglycol (PEG-200)and nano-SiO2. The UV curing kinetics of the films was investigated by FTIR. The results show that the curing speed of the films increases with the adding of nano-SiO2 and decreases with the adding of PUDA due to the slower chain movement. The thermal stability of the HBPUA-PUDA/SiO2 films was studied by using thermogravimetric analysis coupled with Fourier transform infrared spectroscopy (TGA/FTIR). The results show that all films exhibit two degradation stages located at about 320 and 440℃ corresponding to the degradation for hard segments of urethane-acrylate and the degradation for soft segment and polyester core. In addition, the results from the analysis of TGA/FTIR also indicate that the decomposition temperature of HBPUA-PUDA/SiO2 film is 15℃ higher than that obtained for pure polymer. The degradation mechanism was proposed according to TGA/FTIR results. 展开更多
关键词 UV-CURING hyperbranched polyurethane acrylate urethane diacrylate TGA/FTIR thermal degradation
下载PDF
EVA与Silicone密封剂封装对选择性发射极太阳电池效率的影响研究
14
作者 王海林 朱君兰 马跃 《太阳能学报》 EI CAS CSCD 北大核心 2013年第10期1750-1754,共5页
:在构建选择性发射极太阳电池组件光学模型的基础上,引入分贝概念,并在此基础上给出太阳电池组件的外量子效率和内量子效率定义式,使研究太阳电池组件中各部分封装材料对其光电转换效率的影响更加方便。根据密封剂EVA和Silicone的... :在构建选择性发射极太阳电池组件光学模型的基础上,引入分贝概念,并在此基础上给出太阳电池组件的外量子效率和内量子效率定义式,使研究太阳电池组件中各部分封装材料对其光电转换效率的影响更加方便。根据密封剂EVA和Silicone的光透射率测量数据,计算两种密封剂在280~1200nm波段内的吸收损耗。使用光谱响应测试仪分别测量密封剂EVA和Silicone封装的单片电池片在封装前后的量子效率,计算两种密封剂在短波段300~500nto处为选择性发射极电池组件带来的短路电流密度衰减。经比较得出,选择性发射极太阳电池组件使用密封剂Silicone封装可提高其短波响应,提高量子效率。 展开更多
关键词 选择性发射极 封装 silicone 量子效率
下载PDF
Synthesis of Amine-type Adsorbents with Emulsion Graft Polymerization of 4-hydroxybutyl Acrylate Glycidylether 被引量:2
15
作者 Hongjuan Ma Kazuaki Morita +1 位作者 Hiroyuki Hoshina Noriaki Seko 《Materials Sciences and Applications》 2011年第7期776-784,共9页
Radiation induced graft polymerization on polymeric matrix followed by functionalization is widely accepted for the preparation of metal adsorbents. In this paper, a pre-irradiation method was used for emulsion graft ... Radiation induced graft polymerization on polymeric matrix followed by functionalization is widely accepted for the preparation of metal adsorbents. In this paper, a pre-irradiation method was used for emulsion graft polymerization of 4-hydroxybutyl acrylate glycidylether (4-HB) onto polyethylene/polypropylene (PE/PP) nonwoven fabric. The degree of grafting (Dg) which can be calculated by weight increment was determined as a function of reaction time, irradiation dose, and monomer concentration. After 30 kGy irradiation, with 4-HB concentration of 5%, surfactant Span 20 of 0.5% at 40°C for 2 h, the trunk polymer was made grafted at a Dg of 135%. 4-HB-grafted PE/PP nonwoven fabric was modified by ethylenediamine (EDA) in isopropyl alcohol (IPA) as a solvent at 60°C. With a Dg of 135%, the amine group density of the adsorbent is 2.8 mmol/g. The adsorption test was carried out by batch experiment in several metal ion solutions, and the removal ratio from the EDA modified adsorbent of the metal ions is in the order of Cu2+ > Pb2+ > Zn2+ > Ni2+ > Li+. Compared with glycidyl methacrylate (GMA) which is a typical functional monomer for graft polymerization, 4-HB-grafted adsorbent exhibited not only better mechanical property but also higher adsorption capacity of Cu2+ and Pb2+. 展开更多
关键词 Graft Polymerization PRE-IRRADIATION 4-Hydroxybutyl acrylate Glycidylether (4-HB) Glycidyl METHacrylate (GMA) Amine-Type Adsorbent
下载PDF
STUDY ON THE STARCH GRAFTED ACRYLATE MONOMERS AND ITS COMPATIBILITY FOR THE BLEND SYSTEM OF STARCH AND POLYETHYLENE
16
作者 于九皋 李新蕊 《Transactions of Tianjin University》 EI CAS 1997年第1期56-61,共6页
By means of initiation of the high temperature and shearing stress of an extruder,we synthesized the graft copolymer of starch with acrylate monomers based on the simple dry method.The eff... By means of initiation of the high temperature and shearing stress of an extruder,we synthesized the graft copolymer of starch with acrylate monomers based on the simple dry method.The effects of reaction conditions on graft copolymerization were discussed. Grafted starch used as a compatibilizer for the blend system of starch and polyethylene was further investigated. The results indicate that grafted starch as a compatibilizer can improve the mechanical properties and rheologic properties of the blend of starch and polyethylene. 展开更多
关键词 STARCH acrylate graft copolymerization compatibility
下载PDF
New technique for removal of perfluorocarbon liquid related sticky silicone oil and literature review 被引量:1
17
作者 Hai-Shuang Lin Yong-Ping Tang +5 位作者 Lu Zhang En-Ze Liu Ling-Ying Ye Ming-Na Xu Rong-Han Wu Zhi-Xiang Hu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2021年第12期1903-1908,共6页
AIM:To investigate the safety and efficacy of sticky silicone oil(SSO)removal using a 22-gauge vein detained needle and inner limiting membrane(ILM)wrap-and-peel technique.METHODS:This retrospective consecutive case s... AIM:To investigate the safety and efficacy of sticky silicone oil(SSO)removal using a 22-gauge vein detained needle and inner limiting membrane(ILM)wrap-and-peel technique.METHODS:This retrospective consecutive case series reviewed the records of patients with a history of retinal detachment who had received silicone oil and perfluorocarbon liquid(PFCL)as intraocular tamponades.Patients were included in the analysis if they exhibited SSO remnants during silicone oil removal.The aspiration of most of the SSO remnants was performed by a 22-gauge vein detained needle.The small amounts of droplets adhered to the macula and epi-macular membrane were subsequently removed by the ILM warp-and-peel technique.The anatomical and functional outcomes,and postoperative complications were recorded.In vitro experiments were performed to simulate the formation of SSO remnants in four groups.RESULTS:Of 711 patients who underwent silicone oil removal during the study period,9 patients exhibited SSO remnants and underwent follow-up for at least 3mo.Seven eyes(78%)underwent the ILM wrap-and-peel technique to completely remove small droplets of SSO that were glued to the macula and epi-macular membrane.No obvious complications occurred.Postoperative optical coherence tomography revealed normal retinal structure in all patients.In vitro analyses showed that balanced salt solution and prolonged vibration(for 1wk)had the strongest effects on silicone oil and PFCL compound opacities.CONCLUSION:SSO remnants could be removed in an intact manner and without complications,using a vein detained needle-assisted and ILM wrap-and-peel technique.The findings suggest that PFCL and infusion fluid should be completely removed before silicone oil injection to prevent SSO formation. 展开更多
关键词 sticky silicone oil perfluorocarbon liquid silicone oil removal inner limiting membrane peel in vitro analysis
下载PDF
EFFECT OF TEMPERATURE ON COPOLYMERIZATION PARAMETERS OF HYDROXYETHYL ACRYLATE AND METHYL METHACRYLATE
18
作者 李欣欣 印啸敏 +2 位作者 吴平平 韩哲文 朱清仁 《Chinese Journal of Polymer Science》 SCIE CAS CSCD 1998年第1期25-31,共7页
The copolymerization of 2-hydroxyethyl acrylate (HEA, M//1) and methyl methacrylate (MMA, M//2) in cyclohexanone was studied. The multiple experiments of solution copolymerization with low conversion were carried out... The copolymerization of 2-hydroxyethyl acrylate (HEA, M//1) and methyl methacrylate (MMA, M//2) in cyclohexanone was studied. The multiple experiments of solution copolymerization with low conversion were carried out at two sensitive composition feed points at 60, 80, 100, 120 and 140 degree C, respectively. The composition of the copolymers was analyzed by **1H-NMR. The reactivity ratios which were estimated by the Error-in-Variable Method (EVM) of Mayo-Lewis equation were found to be r//1 equals 0.328, r//2 equals 1.781 for 60 degree C; 0.375, 1.709 for 80 degree C; 0.406, 1.654 for 100 degree C; 0.439, 1.540 for 120 degree C and 0.455, 1.400 for 140 degree C, and the 95% joint confidence intervals of the reactivity ratios were also determined. According to r//1 and r//2, Arrhenius relations and the activity energy difference between the homo- and cross-propagation were calculated. (Author abstract) 12 Refs. 展开更多
关键词 reactivity ratio 2-Hydroxyethyl acrylate methyl methacrylate COPOLYMERIZATION copolymer composition
下载PDF
PREPARATION AND MECHANICAL PROPERTIES OF POLY(METHYL METHACRYLATE)/ URETHANE ACRYLATE COPOLYMERS
19
作者 陈大俊 《Journal of China Textile University(English Edition)》 EI CAS 1997年第1期22-27,共6页
The urethane acrylate(UA) was made of poly(tetramethylenc oxide), 4,4’-diphenylmethane diisocyanate, and 2-hydroxyethyl methacrylate. A series of poly(methyl methacrylate) / urethane acrylate copolymers was prepared ... The urethane acrylate(UA) was made of poly(tetramethylenc oxide), 4,4’-diphenylmethane diisocyanate, and 2-hydroxyethyl methacrylate. A series of poly(methyl methacrylate) / urethane acrylate copolymers was prepared by using a redox initiating system. The copolymers had cross linked structures and two-phase morphologies as indicated by the results of the dynamic mechanical measurement and swelling test. 展开更多
关键词 URETHANE acrylate poly(methyl methacrylate) COPOLYMERIZATION cross link.
下载PDF
Intraocular Silicone Oil Removed after 10 Years: A Case Report
20
作者 Mengtian Bai 《Open Journal of Ophthalmology》 2023年第1期30-36,共7页
Background: Silicone oil (SO) has been demonstrated with concrete efficacy and safety in the therapy of complex vitreoretinal diseases. SO is schemed to be cleared within several weeks or months after tamponade, but i... Background: Silicone oil (SO) has been demonstrated with concrete efficacy and safety in the therapy of complex vitreoretinal diseases. SO is schemed to be cleared within several weeks or months after tamponade, but it’s inevitable for permanent or residual SO in a fraction of patients under extremely complicated clinical conditions. Here, we presented a case of silicone oil removal after 10 years, mainly to observe the disadvantages of long-term persistence. Case presentation: A 69-year-old female with pathologic myopia denied trauma history who had undergone pars plana vitrectomy (PPV), retinal reattachment, laser, and silicone oil tamponade in 2012 presented to our hospital with eye pain and headache, no light perception of her right eye for six months. The slit-lamp biomicroscopy examination for OD indicated evident conjunctival congestion, new blood vessels invasion to the limbus, foggy edema of corneal epithelium, folds of Descemet’s membrane and corneal endothelial edema. There were obvious emulsified silicone oil particles above the anterior chamber. Goldmann’s applanation tonometry test revealed the intraocular pressure was as high as 45/17mmHg. From ocular ultrasound, we saw that the vitreous cavity was filled with silicone oil in right eye;as for the left eye, it showed marked axial elongation and posterior scleral staphyloma. We were unable to obtain more information from fundus photography and macular optical coherence tomography (OCT) due to edema of the cornea. After the silicone oil was removed successfully from her vitreous cavity, although there was no improvement in the patient’s vision (no light perception), she was still satisfied with the relief from eye pain and headache benefited from the reduction of high intraocular pressure (Goldmann’s intraocular pressure decreased to 19/14mmHg). Conclusion: Patients after PPV should remove silicone oil in time to avoid corneal damage, intraocular hypertension, lens opacity and retinal damage induced by long-term silicone tamponade. 展开更多
关键词 silicone Oil Long-Term Persistence EMULSIFICATION silicone Retinopathy
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部