期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
On Limitation of Action against Acts of Continuous Infringement of Trademark Right
1
作者 Wang Ze 《China's Foreign Trade》 2005年第3期46-50,共5页
  The right to claim for damages for infringement is of the character of credit and an object of limitation of action. In case of trademark right infringement, the provision on limitation of action of the General Pr...   The right to claim for damages for infringement is of the character of credit and an object of limitation of action. In case of trademark right infringement, the provision on limitation of action of the General Principles of the Civil Law also apply to the trademark proprietor's right to claim for damages for infringement.…… 展开更多
关键词 On Limitation of action against Acts of Continuous Infringement of Trademark Right
下载PDF
A preliminary study of a new high-resolution detector matrix applied to three-dimensional dose verification in intensity-modulated radiotherapy
2
作者 Renchuan Zheng Along Chen +3 位作者 Jinhan Zhu Lixin Chen Shengxiu Jiao Detao Xiao 《Radiation Medicine and Protection》 2021年第3期121-127,共7页
Objective:To test the basic dosimetry characteristics of a new high-resolution matrix and to perform a preliminary study on the three-dimensional(3D)dose verification of intensity-modulated treatment(IMRT).Methods:The... Objective:To test the basic dosimetry characteristics of a new high-resolution matrix and to perform a preliminary study on the three-dimensional(3D)dose verification of intensity-modulated treatment(IMRT).Methods:The dosimetry characteristics of the new matrix were investigated,including repeatability,dose-rate response,and dose linearity.Twenty cases of nasopharyngeal carcinoma(NPC)and 20 cases with lung cancer were randomly selected for IMRT plans,and the novel matrix was employed for 3D dose verification.The measured results were evaluated using the gamma passing rate(GPR)and dose volume histogram(DVH).The action limit(AL)and tolerance limit(TL)of the target volume and each organ at risk(OAR)were calculated with reference to the American Association of Physicists in Medicine(AAPM)TG218 report.Results:The matrix performed well for all dosimetry characteristic tests,with a deviation of<1%.The average GPRs of the body were(99.32±0.32)%,(98.36±0.59)%,and(96.27±1.20)%for NPC,and(99.17±0.74)%,(98.09±1.33)%,and(95.83±2.22)%for lung cancer at the gamma standards of 3%/3 mm,3%/2 mm,and 2%/2 mm.The average GPRs difference between the head-neck and thorax-abdomen plans were<1%for the same gamma standard.For both the target volumes and OARs,the average GPRs were>90%under the relatively strict standard of 2%/2 mm.The DVH showed that the measurement results of D_(98) and D_(95) for the target volumes were slightly lower and D_(2) were higher than those of treatment planning system(TPS)(P<0.01).In addition,with the same standard,there may be significant differences in the values of AL and TL between different structures for target volumes and OARs,especially small-volume OARs such as the chiasma and optic nerve-L.Conclusions:The new matrix showed good dosimetry characteristics and can be effectively applied to the treatment planning dose verification of the head-neck and lung cancer.Further research is needed to establish how to analyze the GPR and DVH of the target volume and OARs,and to determine more precise dose verification standards combined with the parameters of AL and TL to better guide 3D dose verification in clinic. 展开更多
关键词 Three-dimensional dose verification Gamma passing rate Dose volume histogram action limit Tolerance limit
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部